Share:

US-54/70 NBL over La Luz Canyon

Map

Coordinates:
+32.98575, -105.98471
32°59'09" N, 105°59'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-54/70 NBL over La Luz Canyon
Structure number:000000000009666
Location:3.11 M N of US-82
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:89.9 ft. [27.4 m]
Total length:183.1 ft. [55.8 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:41.0 ft. [12.5 m]
Owner:State Highway Agency [01]
Year built:2016
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:12,680 [as of 2018]
Truck traffic:11% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018GoodGoodGoodGood1268098.0
October 2016GoodGoodGoodGood1207098.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.903903000
Deck
Reinforced Concrete Decksq. ft.7,5037,503000
Wearing Surfacessq. ft.7,5037,503000
Substructure
Reinforced Concrete Columneach33000
Reinforced Concrete Abutmentlinear ft.104104000
Reinforced Concrete Pier Caplinear ft.4242000
Joints
Strip Seal Jointlinear ft.9090000
Pourable Jointlinear ft.8484000
Bearings
Elastomeric Bearingeach2020000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.430430000
Concrete Protective Coatingsq. ft.3,0103,010000