Share:

NM-209 over FRIO DRAW

Map

Coordinates:
+34.67530, -103.21470
34°40'31" N, 103°12'53" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NM-209 over FRIO DRAW
Structure number:000000000009669
Location:19.4M N JCT US-60/CLOVIS
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Total length:176.8 ft. [53.9 m]
Roadway width between curbs:28.5 ft. [8.7 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Owner:State Highway Agency [01]
Year built:2015
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,566 [as of 2017]
Truck traffic:14% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:82.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018GoodGoodGoodGood156682.7
January 2016GoodGoodGoodGood147983.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.850085000
Deck
Reinforced Concrete Decksq. ft.7,06707,06700
Substructure
Reinforced Concrete Columneach30300
Reinforced Concrete Abutmentlinear ft.9393000
Reinforced Concrete Pier Caplinear ft.4343000
Joints
Strip Seal Jointlinear ft.8808800
Pourable Jointlinear ft.8885300
Bearings
Elastomeric Bearingeach1010000
Steel Protective Coatingsq. ft.77000
Fixed Bearingeach1010000
Steel Protective Coatingsq. ft.77000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.397397000
Concrete Protective Coatingsq. ft.3,1263,126000