Share:

SR 4008 over Back Creek

Map

Coordinates:
+39.96483, -77.73000
39°57'53" N, 77°43'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 4008 over Back Creek
Structure number:000000000053507
Location:3 MI E OF EDENVILLE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:88.9 ft. [27.1 m]
Total length:92.9 ft. [28.3 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:31.8 ft. [9.7 m]
Owner:State Highway Agency [01]
Year built:2016
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Prestressed concrete [5]
Main span design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:700 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Excellent [9 out of 9]
Superstructure condition:Excellent [9 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.7
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2016GoodExcellentExcellentVery Good70099.7