Share:

TH 36 over ST CROIX RIVER-TH95-UPRR

Map

Coordinates:
+45.04202, -92.78508
45°02'31" N, 92°47'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TH 36 over ST CROIX RIVER-TH95-UPRR
Structure number:82045
Location:0.09 M E OF JCT TH95
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:600.1 ft. [182.9 m]
Total length:5079.3 ft. [1548.1 m]
Roadway width between curbs:80.1 ft. [24.4 m]
Deck width edge-to-edge:98.4 ft. [30.0 m]
Vertical clearance below bridge:105.0 ft. [32.0 m]
Owner:State Highway Agency [01]
Year built:2017
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:6
Main spans material:Prestressed concrete continuous [6]
Main spans design:Segmental box girder [21]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:18,400 [as of 2012]
Truck traffic:4% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Superior to present desirable criteria [9]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Pier/abutment protection:None present but re-evaluation suggested [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:100.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017GoodVery GoodGoodGood18400100.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.10,1448,3301,735790
Steel Main Cablelinear ft.27,46727,467000
Steel Protective Coatingsq. ft.105,173105,173000
Steel Secondary Cableeach8007640
Steel Protective Coatingsq. ft.4,8174,817000
Deck
Prestressed Concrete Top Flangesq. ft.509,790508,89289440
Wearing Surfacessq. ft.482,416482,416000
Substructure
Reinforced Concrete Columneach2626000
Reinforced Concrete Abutmentlinear ft.386377900
Reinforced Concrete Pile Cap/Footinglinear ft.344344000
Reinforced Concrete Pileeach3232000
Prestressed Concrete Pier Caplinear ft.642490191330
Joints
Pourable Jointlinear ft.187187000
Assembly with Sealeach360360000
Bearings
Pot Bearingeach4646000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.10,67510,675000
Steel Protective Coatingsq. ft.22,88322,883000
Reinforced Concrete Bridge Raillinear ft.21,15821,158000