Share:

I676,US30,PATCO over DEL RIV,I-95,RR&ROADS

Map

Coordinates:
+39.95333, -75.13500
39°57'12" N, 75°08'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I676,US30,PATCO over DEL RIV,I-95,RR&ROADS
Structure number:000000000039265
Location:CAMDEN-PHILADELPHIA,PA
Purpose:Carries highway and railroad over highway, waterway, and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Tolls:Yes [1]
Length of largest span:1750.1 ft. [533.4 m]
Total length:8170.3 ft. [2490.2 m]
Roadway width between curbs:77.8 ft. [23.7 m]
Deck width edge-to-edge:82.0 ft. [25.0 m]
Vertical clearance above deck:16.7 ft. [5.1 m]
Vertical clearance below bridge:98.4 ft. [30.0 m]
Owner:Local Toll Authority [32]
Year built:1926
Year reconstructed:1984
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Suspension [13]
Deck type:Steel plate (includes orthotropic) [5]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:112,486 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:35.8

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairGoodSatisfactoryFair11248635.8
September 2016FairGoodSatisfactoryFair8715830.0
2009Fair--Good8715830.0