LOWER DEEP CR ROAD over DEEP CREEK
Map
Coordinates:
+46.29720, -111.4620746°17'50" N, 111°27'43" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | LOWER DEEP CR ROAD over DEEP CREEK |
Structure number: | 000000000007076 |
Location: | 2M SE TOWNSEND |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 24.0 ft. [7.3 m] |
Total length: | 25.9 ft. [7.9 m] |
Roadway width between curbs: | 21.0 ft. [6.4 m] |
Deck width edge-to-edge: | 22.3 ft. [6.8 m] |
Owner: | County Highway Agency [02] |
Year built: | 1978 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Channel beam [22] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 100 [as of 2004] |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Scour calculation/evaluation has not been made. [6] |
Sufficiency rating: | 97.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Good | Satisfactory | Satisfactory | 100 | 97.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 182 | 182 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 582 | 572 | 10 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 93 | 78 | 12 | 3 | 0 |