Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | SH 110 / Cleburne | CREEK | 0.7 MI SE JCT 16 | Concrete Culvert (3 spans) | -- | 1929 | -- | 11.2 | 30.8 | Good | 49.5 | 0000000000M1776 |
NBI report | SH 110 / Cleburne | WATER | 0.97 MI SE JCT 16 | Concrete Culvert (2 spans) | -- | 1929 | -- | 11.2 | 20.7 | Good | 52.4 | 0000000000M1777 |
NBI report | SH 25/Cleburne Co. | CREEK | 1.8 M NE OF SH 124 | Concrete Culvert (2 spans) | -- | 1929 | -- | 9.8 | 22.0 | Good | 85.5 | 0000000000M0584 |
NBI report | SH 25/Cleburne Co. | WATER | .35 M SW OF SH 25 & 16 | Concrete Culvert (2 spans) | -- | 1929 | -- | 11.2 | 21.0 | Good | 67.0 | 0000000000M0587 |
NBI report | SH25B/Cleburne Co. | SUGAR LOAF CREEK | 2.43 MI N JCT OF SH 16 | Concrete Slab (3 spans) | -- | 1929 | -- | 23.0 | 69.9 | Fair | 52.0 | 000000000001209 |
NBI report Bridgehunter | SH 25/Cleburne Co | PINEY CREEK | 2.5 MI SW JCT 107-25 | Concrete Tee beam (4 spans) | NR eligible | 1929 | 1960 | 44.9 | 137.1 | Fair | 48.5 | 000000000000866 |
NBI report | SH 25/Cleburne Co. | CADRON CR. | 0.15 W JCT SH25-107 | Concrete Tee beam (3 spans) | -- | 1929 | 1960 | 29.9 | 89.9 | Fair | 40.8 | 000000000000865 |
NBI report Bridgehunter | SH 25/Cleburne Co | MILL CREEK | .2 MI W JCT SH12&SH25 | Concrete Slab (3 spans) | -- | 1929 | 1972 | 23.0 | 69.9 | Good | 44.7 | 000000000000867 |
NBI report | CR13/Cleburne Co. | TAYLOR CREEK | .10 M S CORD 230 & CORD13 | Concrete Culvert (3 spans) | -- | 1930 | -- | 17.1 | 52.2 | Fair | 67.4 | 000000000011437 |
NBI report | SH 5/Cleburne Co. | WATERWAY | 0.92 MI NO OF WHITE CO LI | Concrete Culvert (3 spans) | -- | 1935 | -- | 11.2 | 32.2 | Good | 83.6 | 0000000000M0147 |
NBI report | SH124/Cleburne Co. | WATER | 2.1 MI SE JCT SH 25 & 124 | Concrete Culvert (3 spans) | -- | 1936 | 1959 | 9.8 | 33.1 | Good | 81.6 | 0000000000M1891 |
NBI report | Libby Rd/Heber Spr | SULPHUR CREEK | 0.1 MI SE JCT SH 110 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1938 | -- | 29.9 | 62.0 | Fair | 76.0 | 0000000000M3767 |
NBI report | SH 337/Cleburne Co | DITCH | 0.22 MI SE JCT SH 337-25 | Concrete Culvert (2 spans) | -- | 1938 | 1994 | 11.2 | 23.0 | Good | 73.6 | 0000000000M3768 |
NBI report | SH 337/Cleburne Co | DITCH | 0.3 MI SE JCT SH 337-25 | Concrete Culvert (3 spans) | -- | 1938 | 1994 | 12.1 | 34.8 | Good | 70.7 | 0000000000M3769 |
NBI report | SH 356/Cleburne Co | CADRON CREEK | 1.7 MI N JCT SH25-356 | Concrete Tee beam (8 spans) | -- | 1950 | 1984 | 20.0 | 160.1 | Good | 87.6 | 0000000000M2957 |
NBI report | SH 25/Cleburne Co. | WATER | .6 M SW OF SH 107 | Concrete Culvert (2 spans) | -- | 1960 | -- | 11.2 | 21.0 | Good | 83.2 | 0000000000M0585 |
NBI report | SH 25/Cleburne Co. | WATER | .05 M N OF SH 107 | Concrete Culvert (2 spans) | -- | 1960 | -- | 11.2 | 21.0 | Good | 82.9 | 0000000000M0586 |
NBI report Bridgehunter | SH 16/Cleburne Co. | DEVILS FORK-GR FR LK | 1.3 MI S OF EDGEMONT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | 1986 | 350.1 | 1391.1 | Good | 82.7 | 000000000003301 |
NBI report | SH 16/Cleburne Co | CADRON CREEK | 1.30 MI NW JCT SH16-25 | Concrete Channel beam (7 spans) | -- | 1961 | -- | 19.0 | 132.9 | Good | 61.8 | 000000000003331 |
NBI report Bridgehunter | SH 16/Cleburne Co. | LITTLE RED RIVER GFL | 2.4 MI E JCT OF SH 92 | Steel Truss - Thru (3 spans) | NR listed | 1961 | -- | 350.1 | 1102.1 | Fair | 48.0 | 000000000003300 |
NBI report | SH 16/Cleburne Co. | NF CADRON CR | .4 MI N JCT SH 225 & 16 | Concrete Channel beam (4 spans) | -- | 1961 | -- | 19.0 | 76.1 | Fair | 63.0 | 000000000003330 |
NBI report | Arkansas Hwy 25 | Dam Spillway | 3 mi. NE of Heber Springs | Steel Girder and floorbeam system (6 spans) | -- | 1964 | -- | 47.6 | 288.1 | Fair | 65.9 | AHTD000000M3512 |
NBI report | CR 56/Cleburne Co. | HILL CREEK | 1.3 M W CR 382 & CR 56 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1964 | -- | 60.0 | 104.0 | Fair | 73.7 | 000000000011442 |
NBI report | CR27/Cleburne Co. | BIG CREEK | 1.25 N W JCT CO 35 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | -- | 16.1 | 32.2 | Fair | 51.4 | 000000000020058 |
NBI report | SH107/Cleburne Co. | CREEK | 0.8 MI N JCT SH 25 & 107 | Concrete Culvert (3 spans) | -- | 1968 | -- | 8.9 | 25.9 | Good | 99.1 | 0000000000X0090 |
NBI report | SH 110/Cleburne Co | LITTLE RED RIVER | 3.45 MI E JCT SH 25 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1971 | -- | 103.0 | 600.1 | Fair | 86.5 | 000000000005293 |
NBI report | SH 225/Cleburne Co | CREEK | 2.2 MI N SH 356 | Concrete Culvert (3 spans) | -- | 1972 | -- | 13.1 | 38.1 | Fair | 91.0 | 0000000000X0187 |
NBI report | SH 225/Cleburne Co | DITCH | 2.9 MI N SH 356 | Concrete Culvert (2 spans) | -- | 1972 | -- | 9.8 | 22.0 | Good | 86.5 | 0000000000X0188 |
NBI report | SH 225/Cleburne Co | DITCH | 1.1 MI S SH 16 | Concrete Culvert (2 spans) | -- | 1972 | -- | 11.2 | 21.0 | Fair | 94.1 | 0000000000X0189 |
NBI report | W SCOTT ST/HEBER | SULPHUR CREEK | .18 W SH 25 | Concrete Channel beam | -- | 1972 | -- | 30.8 | 30.8 | Good | 81.2 | 000000000019667 |
NBI report | CR 373/Cleburne Co | Budd Creek | 1MI E JCT CO RD 39 & 373 | Concrete Slab (3 spans) | -- | 1977 | -- | 35.1 | 105.0 | Good | 79.7 | 000000000004338 |
NBI report | CR61/Cleburne Co. | ROCKY BRANCH CREEK | 3.22MI SO SH 92 Zone D | Concrete Slab (3 spans) | -- | 1977 | -- | 24.9 | 75.1 | Good | 100.0 | 000000000004337 |
NBI report | CR10/Cleburne Co. | BEAVER CREEK | .55 NO JCT SH 25 | Concrete Channel beam (2 spans) | -- | 1981 | 1997 | 19.0 | 38.1 | Fair | 56.8 | 000000000020059 |
NBI report | CR29/Cleburne Co. | LOST BRANCH | 1 MI SO CORD 29 & SH 16 | Concrete Slab (3 spans) | -- | 1984 | -- | 35.1 | 105.0 | Good | 94.8 | 000000000004440 |
NBI report | SH 356/Cleburne Co | MILL CREEK | 1.3 MI N JCT SH25 | Concrete Slab (4 spans) | -- | 1984 | -- | 35.1 | 140.1 | Good | 94.1 | 000000000005973 |
NBI report | Center St. Heber | SULPHUR CREEK | .12 MI SO JCT SH 110 | Concrete Channel beam (3 spans) | -- | 1989 | -- | 20.7 | 59.7 | Good | 95.0 | 000000000020746 |
NBI report | Loop D Road | Collins Creek | John F Kennedy Park | Wood Girder and floorbeam system | -- | 1989 | -- | 44.0 | 44.0 | Good | 100.0 | CEPSWLARGRJFKVB |
NBI report Bridgehunter | CR 2/Cleburne Co. | CADRON CREEK | 1.01 MILES N W SH 356 | Steel Truss - Thru | -- | 1990 | -- | 91.9 | 91.9 | Fair | 54.5 | 000000000022212 |
NBI report | SH 25/Cleburne Co. | SULPHUR CREEK | 0.3 Mi South Jct SH110&25 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 49.9 | 151.9 | Good | 98.1 | 000000000006297 |
NBI report | HOLLOWELL DRIVE | SULPHUR CREEK | .09 MI SOUTH SH 110 | Concrete Channel beam (3 spans) | -- | 1991 | -- | 19.0 | 57.1 | Good | 96.0 | 000000000021033 |
NBI report | E.8TH ST. Heber Sp | SULPHUR CREEK | .39 MILE SO. JCT SH 110 | Concrete Channel beam (3 spans) | -- | 1994 | -- | 19.0 | 57.1 | Fair | 73.8 | 000000000021444 |
NBI report | S.4th St./Heber Sp | SULPHUR CREEK | .25 M SOUTH JCT SH 25B | Concrete Channel beam (2 spans) | -- | 1994 | -- | 30.8 | 62.0 | Good | 96.3 | 000000000021551 |
NBI report | Cleburne CR 79 | WILBURN CREEK | 0.4 MI N. SH 110 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1995 | -- | 40.0 | 202.1 | Good | 89.4 | 000000000004732 |
NBI report | CR87/Cleburne Co. | POSSUM WALK CREEK | 1.9 MILE NCO RD 87&SH25 | Concrete Channel beam (4 spans) | -- | 1996 | -- | 30.8 | 124.0 | Good | 98.9 | 000000000004760 |
NBI report | Cleburne CR 75 | BIG CREEK | JCT CO RD 78 & 75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1997 | -- | 81.0 | 214.9 | Good | 89.4 | 000000000004792 |
NBI report | SH 263/Cleburne Co | DEVIL'S FORK- LITTLE RED | 1.8 MI NW SH 92 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1998 | -- | 144.0 | 526.9 | Good | 93.4 | 000000000006674 |
NBI report | Cleburne CR 13 | CADRON CREEK | .6 M N JCT SH 16 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 76.1 | 202.1 | Good | 98.9 | 000000000004806 |
NBI report | CR147/Cleburne Co. | BRANCH LITTLE RED RIVER | AT JCT CR 145 & 147 | Steel Orthotropic | -- | 1999 | -- | 83.0 | 88.9 | Fair | 58.2 | 000000000022209 |
NBI report | E. Main St. Zone B | SULPHUR CREEK | .12 Mi. E JCT. SH. 110 | Concrete Channel beam (3 spans) | -- | 2001 | -- | 26.9 | 78.1 | Good | 85.9 | 000000000022413 |
NBI report | CR715/Cleburne Co. | Bettis Creek | .1 mi w. of SH 25 | Concrete Channel beam (2 spans) | -- | 2003 | -- | 19.0 | 38.1 | Fair | 73.3 | 000000000022836 |
NBI report | Cleburne CR 95 | BIG CREEK | 2.85 mi. SW SH 87 | Concrete Culvert (5 spans) | -- | 2004 | -- | 9.8 | 52.2 | Good | 91.0 | 000000000022837 |
NBI report | SH 225/Cleburne Co | Midway Branch | 1.35 MI N JCT SH 92 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 2014 | -- | 230.0 | 900.0 | Fair | 94.0 | 000000000007235 |
NBI report | Warren Mtn. Rd. | Big Creek | 1.84 Mi. N. Tylar Rd. Jct | Concrete Culvert (6 spans) | -- | 2017 | -- | 12.1 | 81.0 | Good | 96.0 | 000000000023942 |