CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI reportSPRING STDRAW0.60 MI NE OF PECAN STConcrete Culvert (2 spans)NR possible1930--9.821.0Fair73.8222330B01350008
NBI reportGILLIS STSAN FELIPE CRK0.10 MI NW OF DELAROSA STConcrete Tee beam (5 spans)NR possible1935--29.9149.9Fair70.5222330B00805001
NBI reportUS 90CALAVERAS CREEK1.60 MI E OF US 277Concrete Culvert (6 spans)NR possible193519815.939.0Fair66.5222330002301004
NBI reportUS 90CALAVERAS CREEK1.80 MI E OF US 277Concrete Culvert (5 spans)NR possible193519815.932.2Fair73.1222330002301005
NBI reportCANTU STSAN FELIPE CREEK0.10 MI SE OF MILL STConcrete Tee beam (9 spans)NR possible1935198229.9274.9Fair89.5222330B00365006
NBI reportUS 90W FORK SAN FELIPE CREEK0.15 MI E OF US 277Concrete Tee beam (7 spans)NR possible1935199829.9210.0Fair90.4222330002301001
NBI reportUS 90E FORK SAN FELIPE CREEK0.25 MI E OF US 277Concrete Tee beam (5 spans)NR possible1935199829.9149.9Fair90.4222330002301002
NBI reportUS 90DRAW0.60 MI E OF FM 2523Concrete Culvert (4 spans)NR possible193719815.925.9Good73.1222330002301042
NBI reportUS 90DRAW0.70 MI E OF FM 2523Concrete Culvert (7 spans)NR possible193719815.944.9Good73.1222330002301043
NBI reportUS 90DRAW1.40 MI E OF FM 2523Concrete Culvert (5 spans)NR possible193719815.932.2Fair73.1222330002301044
NBI reportUS 90DRAW2.1 MI S OF US 277Concrete Culvert (9 spans)NR possible193819666.967.9Fair76.1222330002210039
NBI reportUS 90DRAW2.40 MI S OF US 277Concrete Culvert (6 spans)NR possible193819665.939.0Fair76.1222330002210040
NBI reportACADEMY STSAN FELIPE CREEK0.10 MI NE OF PECAN AVEConcrete Culvert (4 spans)NR possible1940--7.937.1Fair57.2222330B00005001
NBI reportSP 297 NBUPRR, OGDEN & CONVERSE0.10 MI S OF US 90Steel Stringer/Multi-beam or girder (3 spans)NR possible1955--89.9630.9Fair75.0222330029901049
NBI reportSP 297 SBUPRR, OGDEN & CONVERSE0.10 MI S OF US 90Steel Stringer/Multi-beam or girder (3 spans)NR possible1955--89.9630.9Fair75.0222330029901039
NBI reportUS 277SAN FELIPE CREEK0.25 MI SE OF US 90Concrete Stringer/Multi-beam or girder (11 spans)NR possible1955198529.9334.0Fair87.2222330029901041
NBI report
Bridgehunter
SPUR 239RIO GRANDE RIVER0.75 MI S OF BORDER STA.Prestressed Stringer/Multi-beam or girder (22 spans)--1988--89.92035.2Good56.0222330B00770002
NBI reportTAINI AVESAN FELIPE CREEK0.40 MI S OF GARFIELD AVEPrestressed Box beam or girders - Multiple--1990--55.158.1Good78.6222330B01405005
NBI reportSPUR 239UPRR & L MARTINEZ BLVD1.10 MI SW OF SPUR 297Prestressed Stringer/Multi-beam or girder (3 spans)--1996--105.0555.1Fair85.0222330016103005
NBI reportSPUR 239DRAIN0.85 MI W OF US 90Concrete Culvert (4 spans)--1998--4.921.0Good95.8222330016103002
NBI reportSPUR 239DRAW2.10 MI SW OF SPUR 297Concrete Culvert (4 spans)--1998--7.936.1Good97.0222330016103004
NBI reportS BEDELL AVESAN FELIPE CREEK0.25 MI SE OF US 90Prestressed Box beam or girders - Multiple--2007--80.180.1Good86.9222330B00275003