Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | WEST THIRD STREET | GREAT MIAMI RIVER | 338' E of EC Moses Blvd | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1904 | 1949 | 127.0 | 721.2 | Poor | 64.7 | 5760127 |
NBI report | SALEM AVENUE | GREAT MIAMI RIVER | .12MI WEST OF JCT IR-75 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1951 | 2001 | 140.1 | 683.1 | Fair | 98.3 | 5761212 |
NBI report | PATTERSON BLVD | GREAT MIAMI RIVER | 0.4 MI N OF E THIRD ST | Steel Girder and floorbeam system (5 spans) | -- | 1954 | -- | 146.0 | 674.9 | Fair | 59.6 | 5760380 |
NBI report | SR-48 | GREAT MIAMI RIVER | .42MI.S. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1956 | -- | 138.1 | 591.9 | Poor | 61.6 | 5703697 |
NBI report | IR75 | STANLEY AVENUE | 1.57MI N OF JCT SR48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | -- | 60.0 | 206.0 | Fair | 94.0 | 5708648 |
NBI report | N PATTERSON BLVD | PEDESTRIAN & BIKE PATH | 0.3 MI N OF E THIRD ST | Concrete Slab | -- | 1959 | -- | 26.9 | 29.9 | Fair | 86.9 | 5762200 |
NBI report | NB SR444 | S4 | JCT SR4 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | -- | 94.2 | 340.9 | Good | 88.6 | 5709938 |
NBI report | VALLEY PIKE | S4 | JCT. SR-444 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | -- | 89.9 | 340.9 | Fair | 89.1 | 5701082 |
NBI report | IR75 | LEO STREET | 1.2MI N OF JCT SR49 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2009 | 65.0 | 147.0 | Good | 96.0 | 5708613 |
NBI report | USR-35 | NORFOLK SOUTHERN RR; Tr | .54MI.W. OF JCT. SR-835 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | 2013 | 85.0 | 311.4 | Good | 100.0 | 5702976 |
NBI report | SR-4 | STANLEY AVENUE | 1.63MI.NE. OF JCT. SR-202 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | -- | 56.1 | 198.2 | Fair | 90.5 | 5700787 |
NBI report | SR-4 | STANLEY AVENUE | 1.63MI.NE. OF JCT. SR-202 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | -- | 56.1 | 198.2 | Fair | 98.0 | 5700817 |
NBI report | STANLEY AVENUE | B&O RAILROAD | 0.4 MI E OF I-75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | 2004 | 68.9 | 232.0 | Fair | 66.6 | 5762316 |
NBI report | SR 4 | SR 201/VALLEY ST. | .1MI.N. OF JCT. SR-4 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 86.9 | 212.0 | Fair | 90.5 | 5700752 |
NBI report | SR 4 | WEBSTER | 0.2 MI E OF I75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 64.0 | 170.0 | Fair | 86.4 | 5760518 |
NBI report | SR 4 | WEBSTER | 0.2 MI E OF I75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1980 | 64.0 | 170.0 | Fair | 95.1 | 5760445 |
NBI report | SR 4 | 201D/KEOWEE AND RAILROAD | 0.4 MI E OF I75 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1961 | 2008 | 94.2 | 360.9 | Good | 88.6 | 5760569 |
NBI report | SR 4 | SR 202 (Troy St) | .1MI.N. OF JCT. SR-4 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 2014 | 56.1 | 149.0 | Good | 76.1 | 5700728 |
NBI report | EMBURY PARK ROAD | IDLEWILDE CREEK 1 | 0.4 MI W OF NORTH DIXIE | Concrete Culvert (2 spans) | -- | 1962 | -- | 7.9 | 21.0 | Good | 98.8 | 5762367 |
NBI report | GETTYSBURG AVENUE | WOLF CREEK | 1.6 MI S OF SR49 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 80.1 | 212.9 | Fair | 76.7 | 5760933 |
NBI report | LIVINGSTON AVE. | LIVINGSTON AVENUE | 1.64MI.W. OF JCT. SR-835 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 62.0 | 167.0 | Good | 96.0 | 5702828 |
NBI report | SMITHVILLE RD. | US35 | 1.03MI.W. OF JCT. SR-835 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 70.9 | 234.9 | Fair | 94.0 | 5702917 |
NBI report | USR-35 | LINDEN AVENUE | 1.85MI.W. OF JCT. SR-835 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 85.0 | 227.4 | Good | 96.0 | 5702798 |
NBI report | WB USR-35 ON RAMP | RAMP=(SMITHVL RD)-US35*W | .83MI.W. OF JCT. SR-835 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 66.9 | 233.9 | Fair | 87.0 | 5702941 |
NBI report | Chambersburg Road | TRIB GREAT MIAMI RIVER | 0.25 MI E OF RIPRAP ROAD | Prestressed Box beam or girders - Multiple | -- | 1963 | 2016 | 29.9 | 33.1 | Good | 79.0 | 5760089 |
NBI report | IR-75 | CARILLON BLVD GT MIAMI R | 1.33MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1965 | -- | 120.1 | 935.1 | Fair | 78.0 | 5707056 |
NBI report | IR-75 | EDWIN C MOSES BOULEVARD | .99MI.S OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 80.1 | 205.1 | Fair | 69.5 | 5707080 |
NBI report | NEEDMORE ROAD | BARTLEY CREEK | 0.9 MI W OF I 75 | Concrete Slab (3 spans) | -- | 1965 | -- | 35.1 | 92.9 | Fair | 77.7 | 5761387 |
NBI report | IR-75 | CINCINNATI STREET | .68MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 2011 | 64.0 | 158.8 | Good | 81.2 | 5707110 |
NBI report | SHOUP MILL ROAD | STILLWATER RIVER | 0.5 MI E OF SR48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 91.9 | 245.1 | Poor | 70.7 | 5761603 |
NBI report | IR-75 | US35 | JCT. USR-35 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1967 | 2012 | 45.9 | 94.2 | Good | 93.0 | 5707536 |
NBI report | NB IR-75 OFF RAMP | ALBANY ST RAMP=ST-I75*N | .13MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1968 | -- | 62.0 | 330.1 | Good | 80.4 | 5707404 |
NBI report | RAMP TO SB IR-75 | ALBANY ST RAMP=I75*S-ST | .13MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1968 | -- | 75.1 | 379.9 | Fair | 73.0 | 5707366 |
NBI report | RAMP TO WB USR-35 | PERRY STREET*N | .22MI.W. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 53.5 | 130.9 | Good | 87.7 | 5701945 |
NBI report | USR-35 | CINCINNATI STREET | .24MI.E. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 52.5 | 141.4 | Good | 71.4 | 5701899 |
NBI report | USR-35 | MOSE BLVD G MM R CRR&STS | .33MI.E. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (14 spans) | -- | 1968 | -- | 189.0 | 1430.2 | Fair | 90.0 | 5701929 |
NBI report | USR-35 | CRR LONGWORTH STREET | .33MI.E. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1968 | -- | 74.2 | 470.2 | Fair | 99.0 | 5701937 |
NBI report | IR-75 | I75&RAMPS US35 CRR | .03MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (11 spans) | -- | 1969 | -- | 137.1 | 1153.9 | Good | 75.5 | 5707447 |
NBI report | IR-75 RAMP * WB-35 | CSRR CRR UND(IR-USR)RAMP | .24MI.W. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (12 spans) | -- | 1969 | -- | 149.6 | 1200.2 | Good | 81.0 | 5701627 |
NBI report | NEEDMORE ROAD | B&O RAILROAD | 0.75 MI E OF I75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 71.2 | 247.1 | Fair | 94.3 | 5763029 |
NBI report | RAMP EB35 TO NB75 | RMP=US35*E-I75*N UN RMPS | .03MI.N. OF JCT USR-35 | Steel Stringer/Multi-beam or girder (10 spans) | -- | 1969 | -- | 126.0 | 1068.0 | Good | 98.0 | 5707595 |
NBI report | RAMP WB35 TO SB75 | RMP=US35*W-I75*S UN RMPS | .01MI.N. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1969 | -- | 118.1 | 430.1 | Fair | 74.0 | 5707560 |
NBI report | USR-35 RAMP * IR75 | CSRR CRR UND(USR-IR)RAMP | .27MI.W. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (13 spans) | -- | 1969 | -- | 99.1 | 1006.0 | Fair | 81.0 | 5701597 |
NBI report | SB IR75 TO EB US35 | IR75, SR4 & RAMP FROM 35 | .08 MI S OF JCT US-35 | Steel Stringer/Multi-beam or girder (14 spans) | -- | 1969 | 2015 | 86.9 | 959.0 | Good | 94.0 | 5707501 |
NBI report | EB USR-35 OFF RAMP | WAYNE AVENUE | .61MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 117.1 | 261.5 | Good | 95.4 | 5702461 |
NBI report | EB USR-35 ON RAMP | S48 | .04MI.S. OF JCT. USR-35 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 98.1 | 188.0 | Good | 96.5 | 5703646 |
NBI report | SR-48 RAMP TO EB35 | JEFFERSON ST*N | .1MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 84.0 | 168.6 | Good | 92.6 | 5702321 |
NBI report | Steve Whalen Blvd | XENIA AVE | 1.71MI.E.OF JCT. SR-48 | Concrete Slab (3 spans) | -- | 1970 | -- | 49.2 | 130.9 | Fair | 96.6 | 5702755 |
NBI report | US 35 | KEOWEE STREET | .75MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1970 | -- | 57.1 | 174.9 | Good | 98.0 | 5702526 |
NBI report | USR-35 | WAYNE AVENUE | .61MI.E. OF JCT.SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 85.3 | 209.3 | Good | 87.1 | 5702437 |
NBI report | USR-35 | SE EXPWY (US35*E)RAMP | 1.65MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1970 | -- | 63.3 | 335.0 | Good | 96.0 | 5702704 |
NBI report | USR-35 OFF RAMP | JEFFERSON ST*N | .1MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 86.9 | 161.4 | Good | 80.0 | 5702283 |
NBI report | WB USR-35 OFF RAMP | RAMP=(WAYNE AVE)-US35*W | .43MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 82.0 | 223.8 | Good | 98.0 | 5702402 |
NBI report | WB USR-35 OFF RAMP | SE EXPWY (US35*E)RAMP | 1.65MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1970 | -- | 86.0 | 349.8 | Good | 68.5 | 5702690 |
NBI report | WB USR-35 OFF RAMP | LUDLOW ST*S (US35*E)RAMP | JCT. SB SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 102.4 | 191.0 | Good | 85.6 | 5703654 |
NBI report | MCCLURE ST. | US35 | 1.09MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1970 | 2007 | 77.1 | 307.1 | Good | 100.0 | 5702550 |
NBI report | EB USR-35 | PERRY ST*N (US35*E)RAMP | .22MI.W. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1971 | -- | 77.1 | 305.1 | Fair | 98.0 | 5701988 |
NBI report | EB USR-35 | LUDLOW ST*S (US35*E)RAMP | .09MI.W. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 73.2 | 250.7 | Good | 99.0 | 5702100 |
NBI report | EB USR-35 | MAIN ST S48 | JCT. SR-48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 88.9 | 266.1 | Good | 97.0 | 5702224 |
NBI report | EB USR-35 | JEFFERSON ST*N | .1MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 77.1 | 175.9 | Good | 97.0 | 5702313 |
NBI report | EB USR-35 OFF RAMP | (US35*E)RAMP US35*W | .25MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 82.4 | 216.2 | Good | 67.5 | 5702348 |
NBI report | WB USR-35 | PERRY STREET*N | .22MI.W. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 62.0 | 159.5 | Good | 98.0 | 5701953 |
NBI report | WB USR-35 | LUDLOW ST*S (US35*E)RAMP | .09MI.W. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 94.5 | 199.2 | Fair | 97.0 | 5702070 |
NBI report | WB USR-35 | MAIN ST S48 JEFRSN ST*N | JCT. SR-48 | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1971 | -- | 117.5 | 724.4 | Good | 98.0 | 5702194 |
NBI report | WB USR-35 OFF RAMP | RAMP=(SE EXPWY*S)-US35*W | 1.54MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 57.1 | 142.1 | Good | 98.0 | 5702615 |
NBI report | BOLTIN ST. | US35 | 1.29MI.E. OF JCT. SR-48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 2007 | 104.7 | 319.9 | Fair | 98.0 | 5702585 |
NBI report | FREDERICK PIKE | BARTLEY CREEK | 0.1 MI S OF NEEDMORE ROAD | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 37.1 | 41.0 | Fair | 92.1 | 5760143 |
NBI report | SMITHVILLE ROAD | LILLY CREEK 2 | S OF SPRINGFIELD STREET | Prestressed Box beam or girders - Multiple | -- | 1984 | -- | 57.1 | 58.1 | Fair | 98.3 | 5760402 |
NBI report | MCGEE BLVD. | U.S.R.-35 | 1.63MI.W. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1991 | -- | 82.0 | 149.9 | Good | 94.0 | 5712998 |
NBI report | USR-35 | PAUL LAWRENCE DUNBAR BLV | 1.28MI.W.OF JCT. IR-75 | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 53.2 | 57.1 | Fair | 99.0 | 5713021 |
NBI report | USR-35 | GERMANTOWN STREET | 1.2MI.W.OF JCT. IR-75 | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 110.9 | 116.1 | Fair | 98.0 | 5713064 |
NBI report | USR-35 | BROADWAY STREET | 1.1MI.W.OF JCT. IR-75 | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 51.8 | 57.1 | Good | 95.0 | 5713099 |
NBI report | LITTLE RICHMOND RD | THIMBLE CREEK | 0.5 MI E OF OLIVE ROAD | Steel Stringer/Multi-beam or girder | -- | 1992 | -- | 52.5 | 58.4 | Good | 80.1 | 5760410 |
NBI report | OLIVE ROAD | TRIB WOLF CREEK N OF LR | 0.5MI N OF LITTLE RICHMND | Concrete Frame | -- | 1993 | -- | 23.0 | 24.9 | Good | 94.4 | 5760429 |
NBI report | Olive Road | trib. to Wolf Creek | .1M S. of Little Richmond | Concrete Frame | -- | 1993 | -- | 21.3 | 24.0 | Good | 98.2 | 5760488 |
NBI report Bridgehunter | WAGNER FORD ROAD | GREAT MIAMI RIVER | 1 MI N OF NEEDMORE ROAD | Steel Truss - Thru (2 spans) | Closed | 1994 | -- | 152.9 | 305.1 | Fair | 7.0 | 5760453 |
NBI report | MCCALL STREET | USR-35 | 1.96MI.W. OF JCT. IR-75 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1996 | -- | 121.4 | 238.5 | Good | 96.6 | 5701589 |
NBI report | USR-35 | GETTYSBURG AVE. & LAKE | 3.02MI. W. JCT. IR-75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1996 | -- | 147.0 | 595.5 | Good | 94.3 | 5701562 |
NBI report | USR-35 | GETTYSBURG AVE. & LAKE | 3.02 MI. W. JCT. IR-75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1996 | -- | 147.0 | 595.5 | Good | 94.3 | 5701570 |
NBI report | USR-35 | HOME AVE.,R.R. | 2.08 MI. W. JCT. IR-75 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1996 | -- | 123.7 | 586.6 | Good | 94.3 | 5701600 |
NBI report | USR-35 | HOME AVE, FRONTAGE RD &R | 2.08 MI. W. JCT. IR-75 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1996 | -- | 123.4 | 550.2 | Good | 94.3 | 5701619 |
NBI report | MOO99 KE0WEE ST. | MAD RIVER | .18 MI. S. OF JCT. SR-202 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1997 | -- | 99.1 | 280.9 | Good | 76.5 | 5700515 |
NBI report | GUENTHER ROAD | GUENTHER DITCH | 950 FT N OF HOOVER | Concrete Culvert | -- | 1998 | -- | 21.7 | 24.0 | Fair | 92.6 | 5760593 |
NBI report | SPRINGFIELD ST. | LILLY CREEK | 0.1 MILE W SMITHVILLE RD. | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 57.1 | 63.0 | Good | 73.2 | 5762804 |
NBI report | SR-49 | SOUTH BRANCH THIMBLE CR. | 2.5MI N OF USR35 JUNCTION | Concrete Culvert (2 spans) | -- | 1998 | -- | 16.7 | 33.5 | Good | 83.4 | 5704057 |
NBI report | SR-49 | NORTH BRANCH THIMBLE CR. | 2.66M N OF USR35 JUNCTION | Concrete Culvert (2 spans) | -- | 1998 | -- | 10.5 | 24.0 | Good | 83.4 | 5704065 |
NBI report | SR-49 | CITY RAILROAD | 2.75M N OF USR35 JUNCTION | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 58.1 | 147.3 | Good | 81.3 | 5704073 |
NBI report | Rip Rap | Great Miami River | .5 MILES N OF NEEDMORE RD | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 2001 | -- | 120.1 | 856.0 | Fair | 98.1 | 5760585 |
NBI report | E HELENA STREET | ISLAND PARK LAGOON GMR | 1000FT E INT HELNA AND RS | Concrete Culvert | -- | 2003 | -- | 24.0 | 25.9 | Fair | 97.1 | 5760720 |
NBI report | W. 5TH ST SR4 | GREAT MIAMI RIVER | .13MI.E. OF JCT. IR75 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2003 | -- | 123.4 | 623.4 | Fair | 98.6 | 5700485 |
NBI report Bridgehunter | SIEBENTHALER AVE | STILLWATER RIVER | 0.6 MILE EAST OF SR 48 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 105.0 | 263.1 | Good | 76.1 | 5761875 |
NBI report | FINDLAY STREET | MAD RIVER AND BIKE PATH | .2 MI S JCT SR 4 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2006 | -- | 130.9 | 395.0 | Good | 80.5 | 5761115 |
NBI report | WASHINGTON STREET | GREAT MIAMI RIVER | 200 FT E OF EC MOSES BLVD | Prestressed Box beam or girders - Multiple (7 spans) | -- | 2007 | -- | 89.9 | 631.9 | Fair | 80.1 | 5760070 |
NBI report | I-75 RAMP D4 | RAMP D4 OVER RAMP E5 | I 75 & SR 48 RAMP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2008 | -- | 158.1 | 382.6 | Good | 94.0 | 5708532 |
NBI report | P.L. DUNBAR STREET | WOLF CREEK | 1800 FT N OF W THIRD ST | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2008 | -- | 69.9 | 213.9 | Good | 75.5 | 5760771 |
NBI report | RAMPS E2 & D4 | RAMPS E4&D4 OVER GR.MIAM | .25MI. N. OF JCT. SR48 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 2008 | -- | 137.1 | 957.4 | Good | 94.0 | 5708397 |
NBI report | SR 4 | SR 48 | JCT. SR-48 | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 135.8 | 137.8 | Good | 98.0 | 5708311 |
NBI report | GOODLOW AVENUE | GUENTHER DITCH | SOUTH OF HOOVER | Concrete Arch - Deck | -- | 2009 | -- | 23.0 | 25.9 | Good | 72.2 | 5762685 |
NBI report | IR 75 | KEOWEE STREET | .9MI. N. OF JCT. SR48 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 107.0 | 238.2 | Good | 94.0 | 5708575 |
NBI report | IR-75 | GREAT MIAMI RIVER | 1.77MI N. OF JCT. SR48 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2009 | -- | 136.2 | 577.8 | Good | 87.5 | 5708710 |
NBI report | IR75 | GR MIAMI R RIVERSIDE DR | .25 MI N JCT SR 48 | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 2009 | -- | 129.9 | 1048.9 | Good | 83.0 | 5708389 |
NBI report | IR75 | RAMPS E4 & E5 | .46 MI N OF JCT SR48 | Steel Stringer/Multi-beam or girder | -- | 2009 | -- | 141.4 | 150.6 | Good | 87.5 | 5708451 |
NBI report | SB/NB IR 75 | SR48 | JCT SR48/I75 | Prestressed Stringer/Multi-beam or girder | -- | 2009 | -- | 123.0 | 129.9 | Good | 98.0 | 5708338 |
NBI report | SR 4 | IR 75 & RAMP | .46MI N OF JCT SR48 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2009 | -- | 153.6 | 491.2 | Good | 98.0 | 5708443 |
NBI report | STEWART STREET | GREAT MIAMI RIVER | .6 MI E I-75 | Prestressed Box beam or girders - Multiple (7 spans) | -- | 2009 | -- | 109.9 | 660.1 | Fair | 95.6 | 5760038 |
NBI report | SR 4 | RAMP D5 | .05MI. N. OF JCT. SR48 | Prestressed Stringer/Multi-beam or girder | -- | 2010 | -- | 134.5 | 153.2 | Good | 100.0 | 5708354 |