Bridges of Pasadena, California

CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI report
Bridgehunter
COLORADO BLVDARROYO BLVD / ARROYO S0.5MI E/O SAN RAFAEL AVEConcrete Arch - Deck (11 spans)NR listed19131993223.11442.3Fair74.353C0107
NBI report
Bridgehunter
LA LOMA RDARROYO SECO CHAN100FT W/O ARROYO BLVDConcrete Arch - Deck (2 spans)NR possible1914--101.4379.0Poor46.753C0759
NBI report
Bridgehunter
SAN RAFAEL AVEARROYO SECO CHAN100FT W/O ARROYO BLVDConcrete Arch - Deck (8 spans)NR eligible1922--154.9258.9Good75.953C0757
NBI report
Bridgehunter
HOLLY STARROYO BLVD / ARROYO S0.2MI W/O US-101 FWYConcrete Arch - DeckNR eligible1925--240.2400.0Poor39.453C1041
NBI reportCOLORADO BLVDEATON WASH0.4MI E/O SAN GABRIEL BLConcrete Tee beam (2 spans)--1925197326.954.1Good95.153C1842
NBI report
Bridgehunter
DEL MAR BLVDEATON WASH0.5MI E/O SN GABRIEL BLVDConcrete Arch - Deck (3 spans)--1926--56.175.8Fair95.453C0580
NBI report
Bridgehunter
ARROYO BLVDARROYO SECO CHAN0.1MI N/O SR-134 FWYConcrete Arch - Deck (5 spans)--1927--30.8115.8Fair73.953C0758
NBI report
Bridgehunter
STATE ROUTE 2SLIDE CANYON07-LA-002-28.58-PASConcrete Slab--1931--100.1181.1Good84.053 0063
NBI reportSTATE ROUTE 2HILLSIDE07-LA-002-29.08-PASConcrete Slab (4 spans)--1931--20.082.0Good70.653 0088
NBI reportSECO STARROYO SECO CHAN0.1MI W/O ARROYO BLVDConcrete Slab--1939--60.066.6Fair78.753C0756
NBI reportWASHINGTON BLVDARROYO SECO CHAN0.8MI W/O FAIR OAKS AVEConcrete Slab--1939--75.183.0Good82.453C0755
NBI reportCHATEAU RDUNNAMED WASH0.2MI N/O US-101 FWYConcrete Tee beam--1940--35.136.1Good51.453C1736
NBI report
Bridgehunter
SR 134ARROYO SECO & STREETS07-LA-134-R12.57-PASConcrete Arch - Deck (3 spans)--19531971319.91346.5Good78.053 0166
NBI reportCOLORADO BLVDLINDA VISTA AVE0.2MI E/O SAN RAFAEL AVEConcrete Box beam or girders - Multiple--1954--50.997.4Fair58.753C1841
NBI reportORANGE GROVE AVEEATON WASH0.4MI W/O SRRA MADRE VLLAConcrete Slab--1954--30.540.7Good94.853C0794
NBI report
Bridgehunter
OAK GROVE DRARROYO SECO0.2MI W/O WINDSOR AVEConcrete Box beam or girders - Multiple (3 spans)--1955--141.1404.5Fair79.853C1829
NBI reportOAK GROVE DRFLINT CYN WASH0.3MI W/O WINDSOR AVEConcrete Box beam or girders - Multiple (3 spans)--1955--100.1348.8Fair88.853C1851
NBI reportPALOMA STEATON WASH0.4MI W/O SIERRA MADRE VLConcrete Slab--1958--33.838.1Good96.953C1438
NBI reportSIERRA MDR BLVD WEATON WASH0.5MI W/O SIERRA MADRE VLConcrete Slab--1958--25.327.6Fair76.953C0657L
NBI reportSIERRA MDRE BLVD EEATON WASH0.5MI W/O SIERRA MDRE VLLConcrete Slab--1958--26.228.5Fair88.753C0657R
NBI reportNEW YORK DR EBEATON WASH1.0MI NW/O SIERRA MADRESteel Stringer/Multi-beam or girder (2 spans)--1962--75.1154.5Poor78.953C0785R
NBI reportNEW YORK DR WBEATON WASH1.0MI N/O SIERRA MADRE BLSteel Stringer/Multi-beam or girder (2 spans)--1962--75.1150.9Poor78.753C0785L
NBI reportCOLORADO BLVD WBE134-COLORADO BL OFF-RMP07-LA-134-R12.90-PASConcrete Box beam or girders - Multiple (3 spans)--1971--83.0191.0Good93.253 2226
NBI reportINTERSTATE 210 EBROSEMEAD BLVD07-LA-210-R29.49-PASPrestressed Stringer/Multi-beam or girder--1971--97.1100.1Good65.553 1957R
NBI reportINTERSTATE 210 WBROSEMEAD BLVD07-LA-210-R29.49-PASPrestressed Stringer/Multi-beam or girder--1971--97.1100.1Good72.253 1957L
NBI reportORANGE GROVE BLVDSTATE ROUTE 134 & RAMPS07-LA-134-R12.96-PASPrestressed Box beam or girders - Multiple (2 spans)--1971--148.0274.0Fair77.653 0763
NBI reportORANGE GROVE-W134ST RTE 134 & STREETS07-LA-134-R12.90-PASPrestressed Box beam or girders - Multiple (2 spans)--1971--175.9829.1Good73.653 2197K
NBI reportSAN RAFAEL AVESTATE ROUTE 13407-LA-134-R12.36-PASConcrete Box beam or girders - Multiple (2 spans)--1971--94.5189.0Fair77.553 2097
NBI reportW210-FOOTHILL OFFROSEMEAD BLVD07-LA-210-R29.49-PASPrestressed Stringer/Multi-beam or girder--1971--115.2228.0Fair95.753 1957K
NBI reportFAIR OAKS AVEMTA0.3MI N/O SR-110 FWYConcrete Tee beam (3 spans)--1972--65.0169.6Fair84.653C0863
NBI reportFOOTHILL BLVDEATON WASHE/O SAN GABRIEL BLVDPrestressed Box beam or girders - Multiple--1972--44.052.5Fair80.453C0765
NBI reportMAPLE STEATON WASH0.1MI N/O FOOTHILL BLVDConcrete Culvert--1972--44.352.5Good95.953C0796
NBI reportARROYO BLVDROUTE 21007-LA-210-R22.49-PASPrestressed Box beam or girders - Multiple (2 spans)--1973--125.0250.0Fair94.353 2153
NBI reportINTERSTATE 210CASITAS AVE07-LA-210-R22.84-PASPrestressed Box beam or girders - Multiple--1973--140.1143.1Good86.553 2154
NBI reportINTERSTATE 210LINCOLN - HOWARD UC07-LA-210-R23.19-PASPrestressed Box beam or girders - Multiple (4 spans)--1973--146.0550.9Good86.553 2155
NBI reportINTERSTATE 210WASHINGTON BLVD07-LA-210-R23.55-PASPrestressed Box beam or girders - Multiple--1973--137.1140.1Good87.653 2157
NBI reportINTERSTATE 210HAMMOND STREET07-LA-210-R23.80-PASPrestressed Box beam or girders - Multiple--1973--128.9131.9Good87.653 2158
NBI reportINTERSTATE 210MOUNTAIN AVENUE07-LA-210-R24.06-PASPrestressed Box beam or girders - Multiple--1973--149.9152.9Fair86.553 2159
NBI reportINTERSTATE 210LINCOLN AVE07-LA-210-R24.17-PASPrestressed Box beam or girders - Multiple (3 spans)--1973--142.1249.0Good87.653 2160
NBI reportINTERSTATE 210 OFFHOWARD STREET07-LA-210-R23.22-PASPrestressed Box beam or girders - Multiple--1973--151.9153.9Good93.453 2156K
NBI reportINTERSTATE 210 ONRLINCOLN AVE07-LA-210-R24.17-PASPrestressed Box beam or girders - Multiple (3 spans)--1973--157.2255.9Good95.653 2160S
NBI reportORANGE GROVE BLVDI 210 & CONNECTORS07-LA-210-R24.64-PASPrestressed Box beam or girders - Multiple (2 spans)--1973--194.9449.2Fair95.253 2195
NBI reportE134-FAIR OAKS AVEN710-E210 CONNECTOR07-LA-210-R25.12-PASPrestressed Box beam or girders - Multiple (3 spans)--1974--173.9362.9Good87.953 2323S
NBI reportE134-W210 CONNECTR210,710,134 & CONN07-LA-134-R13.25-PASPrestressed Box beam or girders - Multiple (4 spans)--1974--174.91684.1Good92.853 2318G
NBI reportINTERSTATE 210FLINT CANYON WASH07-LA-210-R21.84-PASConcrete Box beam or girders - Multiple (4 spans)--1974--169.0452.1Good87.453 0579
NBI reportINTERSTATE 210ARROYO SECO07-LA-210-R22.14-PASPrestressed Box beam or girders - Multiple (3 spans)--1974--230.0579.1Good84.353 2173
NBI reportMAPLE ST-W210W210-S710 & W210 CONN07-LA-210-R25.21-PASPrestressed Box beam or girders - Multiple (2 spans)--1974--165.0295.9Fair70.353 2259K
NBI reportORANGE GROVE-E134SR 134 & CONNECTORS07-LA-134-R13.07-PASPrestressed Box beam or girders - Multiple (2 spans)--1974--155.2736.9Good95.553 2269S
NBI reportW134-ORANGE GROVEE210-W134 & N710-W13407-LA-134-R13.08-PASPrestressed Box beam or girders - Multiple (3 spans)--1974--174.9436.0Good80.553 2253K
NBI reportW210-S710 CONNROUTE 210 EB07-LA-210-R25.10-PASPrestressed Box beam or girders - Multiple--1974--151.9153.9Good91.553 2255F
NBI reportWALNUT STE210-W134 CONNECTOR RAMP07-LA-210-R24.94-PASPrestressed Box beam or girders - Multiple--1974--142.1145.0Good97.453 2260
NBI report134 210/710,210 SE210, 710, STREET & CONN07-LA-134-R13.24-PASPrestressed Box beam or girders - Multiple (3 spans)--1975--220.2752.7Fair71.053 2317
NBI reportCOLORADO BLVDINTERSTATE 71007-LA-710-R32.45-PASPrestressed Box beam or girders - Multiple (2 spans)--1975--207.0415.0Good96.953 2264
NBI reportDEL MAR BLVDINTERSTATE 71007-LA-710-T32.11-PASPrestressed Box beam or girders - Multiple (2 spans)--1975--180.1357.0Good98.953 2262
NBI reportDYNA-METRIC DRWYEB 134-SB 710 CONNECTOR07-LA-134-R13.22-PASConcrete Box beam or girders - Multiple--1975--59.759.7Good93.953 2431Y
NBI reportE210 CONN UCROUTE 210 EBND07-LA-210-R25.13-PASConcrete Box beam or girders - Multiple--1975--48.958.4Good84.053 2256
NBI reportFAIR OAKS AVEROUTE 21007-LA-210-R25.29-PASPrestressed Box beam or girders - Multiple (4 spans)--1975--141.1464.9Fair88.453 2272
NBI reportGREEN STINTERSTATE 71007-LA-710-R32.37-PASPrestressed Box beam or girders - Multiple (2 spans)--1975--174.9354.0Fair80.153 2263
NBI reportMAPLE STI-210 & I-710 CONN07-LA-210-R24.86-PASPrestressed Box beam or girders - Multiple (3 spans)--1975--161.1954.1Fair96.953 2254
NBI reportN710-W134 CONNECTRI 710, CONNS, ST JOHN AV07-LA-710-R32.63-PASPrestressed Box beam or girders - Multiple (2 spans)--1975--180.1847.2Fair95.953 2266G
NBI reportRTE 210-710W210-S710 CONNECTOR RAMP07-LA-210-R24.92-PASConcrete Frame--1975--57.164.0Good92.453 2268
NBI reportRTE 210-710DIRECT EBND 21007-LA-210-R24.77-PASConcrete Frame--1975--59.166.9Good84.253 2341
NBI reportS. PASADENA AVEN710-E210 CONNECTOR RAMP07-LA-710-R32.68-PASPrestressed Box beam or girders - Multiple--1975--187.0189.0Good86.453 2257
NBI reportST JOHN AVENUEE134-S710 CONNECTOR RAMP07-LA-134-R13.23-PASPrestressed Box beam or girders - Multiple--1975--103.7103.7Good93.853 2265
NBI reportUNION STREETINTERSTATE 71007-LA-710-R32.51-PASPrestressed Box beam or girders - Multiple (4 spans)--1975--138.1462.6Fair96.353 2537
NBI reportWALNUT STN710-E210 CONNECTOR RAMP07-LA-710-R32.69-PASPrestressed Box beam or girders - Multiple--1975--149.9152.2Fair84.253 2258
NBI reportWALNUT STREETW210&E210-S710,N710-W21007-LA-210-R24.95-PASPrestressed Box beam or girders - Multiple (2 spans)--1975--137.1256.9Good95.453 2267
NBI reportE210-ROSEMEAD OFFSIERRA MADRE & E210 ONRP07-LA-210-R29.35-PASPrestressed Box beam or girders - Multiple (4 spans)--1976--122.1434.4Good97.553 2398S
NBI reportEL MOLINO AVEROUTE 21007-LA-210-R26.07-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--204.1338.9Fair93.653 2275
NBI reportINTERSTATE 210 EBCRAIG AVE07-LA-210-R27.81-PASPrestressed Box beam or girders - Multiple--1976--154.2154.2Fair82.053 2041R
NBI reportINTERSTATE 210ALLEN AVE07-LA-210-R27.41-PASConcrete Box beam or girders - Multiple (2 spans)--1976--94.2189.0Good65.053 2040L
NBI reportINTERSTATE 210ALLEN AVE07-LA-210-R27.41-PASConcrete Box beam or girders - Multiple (2 spans)--1976--94.2189.0Good82.053 2040R
NBI reportINTERSTATE 210SIERRA BONITA AVE07-LA-210-R27.18-PASPrestressed Box beam or girders - Multiple--1976--157.2159.1Good66.053 2093L
NBI reportINTERSTATE 210SIERRA BONITA AVE07-LA-210-R27.18-PASPrestressed Box beam or girders - Multiple--1976--157.2159.1Good83.053 2093R
NBI reportINTERSTATE 210FOOTHILL BLVD07-LA-210-R28.87-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--127.0253.9Fair81.053 2099L
NBI reportINTERSTATE 210FOOTHILL BLVD07-LA-210-R28.87-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--127.0253.9Fair81.053 2099R
NBI reportINTERSTATE 210ALTADENA DR07-LA-210-R28.25-PASConcrete Box beam or girders - Multiple (2 spans)--1976--95.1190.0Good82.053 2278L
NBI reportINTERSTATE 210ALTADENA DR07-LA-210-R28.25-PASConcrete Box beam or girders - Multiple (2 spans)--1976--95.1190.0Good83.053 2278R
NBI reportINTERSTATE 210SIERRA MADRE BLVD07-LA-210-R28.46-PASPrestressed Box beam or girders - Multiple (3 spans)--1976--107.9326.1Good81.053 2279L
NBI reportINTERSTATE 210SIERRA MADRE BLVD07-LA-210-R28.46-PASPrestressed Box beam or girders - Multiple (4 spans)--1976--113.9373.0Fair80.053 2279R
NBI reportINTERSTATE 210SUNNYSLOPE AVE07-LA-210-R28.73-PASPrestressed Box beam or girders - Multiple--1976--205.1205.1Good83.053 2280L
NBI reportINTERSTATE 210SUNNYSLOPE AVE07-LA-210-R28.73-PASPrestressed Box beam or girders - Multiple--1976--203.1203.1Fair72.053 2280R
NBI reportINTERSTATE 210EATON WASH07-LA-210-R28.86-PASConcrete Culvert--1976--29.934.1Good83.053 2397
NBI reportINTERSTATE 210KINNELOA AVE07-LA-210-R29.02-PASConcrete Frame--1976--64.064.0Good85.053 2508
NBI reportINTERSTATE 210 EBSIERRA MADRE VILLA AVE07-LA-210-R29.29-PASConcrete Box beam or girders - Multiple (2 spans)--1976--89.9180.1Good82.053 1966R
NBI reportINTERSTATE 210 EBABANDONED RR ROW07-LA-210-R29.09-PASConcrete Slab--1976--25.926.6Good82.953 2045R
NBI reportINTERSTATE 210 EBHILL AVE07-LA-210-R26.94-PASConcrete Box beam or girders - Multiple (2 spans)--1976--81.0165.0Good84.053 2084R
NBI reportINTERSTATE 210 EBMETROLINK07-LA-210-R25.59-PASConcrete Frame--1976--40.044.0Good85.053 2281R
NBI reportINTERSTATE 210 WBSIERRA MADRE VILLA AVE07-LA-210-R29.29-PASConcrete Box beam or girders - Multiple (2 spans)--1976--85.0170.9Good81.053 1966L
NBI reportINTERSTATE 210 WBCRAIG AVE07-LA-210-R27.81-PASPrestressed Box beam or girders - Multiple--1976--152.9154.2Good83.053 2041L
NBI reportINTERSTATE 210 WBHILL AVE07-LA-210-R26.94-PASConcrete Box beam or girders - Multiple (2 spans)--1976--82.0165.0Good82.053 2084L
NBI reportLOS ROBLES AVEROUTE 21007-LA-210-R25.81-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--173.9326.1Good91.953 2274
NBI reportMARENGO AVEROUTE 21007-LA-210-R25.54-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--174.9352.1Fair91.653 2273
NBI reportMARENGO AVEMTAINTX MARENGO CORSON I-210Concrete Frame--1976--40.074.2Fair77.453C1898
NBI reportWALNUT STMTA0.1MI E/O FAIR OAKS AVEConcrete Slab--1976--29.940.4Fair78.753C0367
NBI reportWILSON AVEROUTE 21007-LA-210-R26.57-PASPrestressed Box beam or girders - Multiple (2 spans)--1976--159.1316.9Fair93.053 2277
NBI reportLAKE AVEROUTE 21007-LA-210-R26.33-PASPrestressed Box beam or girders - Multiple (2 spans)--19761996151.9277.9Good86.053 2276
NBI reportPROSPECT BLVDSECO ST0.4MI S/O LINCOLN BLVDPrestressed Box beam or girders - Multiple (4 spans)--1989--115.2401.9Fair93.953C0264
NBI reportSR 2 EBHILLSIDE07-LA-002-28.43-PASConcrete Slab (11 spans)--1995--7.980.1Good96.653 2798
NBI reportSR 2 EBHILLSIDE07-LA-002-28.46-PASConcrete Slab (13 spans)--1995--7.998.4Good96.653 2799
NBI reportFAIR OAKS-E210 HOVI 210 MEDIAN07-LA-210-R25.30-PASConcrete Box beam or girders - Multiple (4 spans)--1996--71.9302.5Fair96.953 2782