Bridges of Reno, Nevada

CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI report
Bridgehunter
SR430 S VIRGINIADRY CREEKRENOConcrete Arch - Deck--1920195035.138.1Fair91.7B 177
NBI reportARLINGTON AVTRUCKEE RVRRENO - N BRIDGEConcrete Tee beam (3 spans)--1921196743.0122.1Poor50.2B1532
NBI reportSR430 N VIRGINIADITCHRENOConcrete Culvert (2 spans)--192219609.823.0Fair73.8B 227
NBI reportLAKE STTRUCKEE RVRRENOConcrete Tee beam (3 spans)--1937--64.0152.9Fair72.9B 304
NBI reportSR 660 SIERRA STTRUCKEE RVRRENOSteel Stringer/Multi-beam or girder (3 spans)NR eligible1937--50.9136.2Poor59.9B 303
NBI reportARLINGTON AVTRUCKEE RVRRENO - S BRIDGEConcrete Slab--1938--45.947.9Poor55.5B1531
NBI reportI 80HIGHLAND DITCH (OLD)WEST OF RENOConcrete Culvert--1938196437.144.0Fair69.9B 127
NBI reportUS 395NSR673 STEAD BLSTEADConcrete Slab (3 spans)--1960--37.1123.0Good96.0I 683N
NBI reportUS 395SSR673 STEAD BLSTEADConcrete Slab (3 spans)--1960--37.1123.0Good96.0I 683S
NBI reportLONGLEY LNAIRPORT SLOUGHRENOWood Stringer/Multi-beam or girder (4 spans)--1965197824.978.1Fair81.2B1580
NBI reportI 80EMAE ANNE AVNEAR VERDIConcrete Box Beam or girders - Single or Spread (3 spans)--1966--71.9120.1Fair91.7H 767E
NBI reportI 80ESTOKER AVRENOConcrete Box beam or girders - Multiple (3 spans)--1966--67.9151.9Fair94.4H1162E
NBI reportI 80WMAE ANNE AVNEAR VERDIConcrete Box Beam or girders - Single or Spread (3 spans)--1966--71.9120.1Fair91.7H 767W
NBI reportI 80WSTOKER AVRENOConcrete Box beam or girders - Multiple (3 spans)--1966--67.9151.9Fair94.4H1162W
NBI reportKEYSTONE AVTRUCKEE RIVERRENOSteel Stringer/Multi-beam or girder (4 spans)--1966--146.0393.7Poor35.3B1530
NBI reportSR 667/KIETZKE LNTRUCKEE RIVERRENOConcrete Box Beam or girders - Single or Spread (3 spans)--1966--120.1344.2Good80.9B 578N
NBI reportSR 667/KIETZKE LNTRUCKEE RIVERRENOConcrete Girder and floorbeam system (3 spans)--1966--120.1344.2Fair79.9B 578S
NBI reportKEYSTONE AVEFOSTER DRRENOConcrete Slab--1966197425.927.9Fair78.2H1529
NBI reportCEMETERY ROADI 80WEST OF RENOConcrete Box Beam or girders - Single or Spread (4 spans)--1966197570.9236.9Fair53.2H 768
NBI reportUS 395SR663 ODDIE BLRENOConcrete Box beam or girders - Multiple (4 spans)--1967197469.9182.1Good86.6I1089
NBI reportUS 395NSR430 N VIRGINIA STRENOConcrete Box beam or girders - Multiple (4 spans)--1967197469.9183.1Fair77.2I1093N
NBI reportUS 395SSR430 N VIRGINIA STRENOConcrete Box beam or girders - Multiple (4 spans)--1967197470.2183.1Fair96.6I1093S
NBI reportUS 395WEDEKIND RDRENOConcrete Tee beam (3 spans)--1967198960.0103.0Good76.7H1090
NBI reportSIERRA STI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1968--71.9216.9Good75.1I 992
NBI reportCENTER STI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1969--71.9207.0Fair77.1I 994
NBI reportEVANS STI 80RENOConcrete Box beam or girders - Multiple (5 spans)--1969--83.0276.9Fair95.5H 995
NBI reportI 580RMP I80E TO US395NRENOConcrete Box beam or girders - Multiple (3 spans)--1969--66.9144.0Fair81.7I1149
NBI reportRALSTON STI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1969--71.9242.1Fair86.3H 991
NBI reportRMP 395S TO 80EI 80RENOConcrete Box Beam or girders - Single or Spread (4 spans)--1969--82.0228.0Fair92.5I1000
NBI reportRMP 80W TO 395SI 80RENOConcrete Box Beam or girders - Single or Spread (4 spans)--1969--81.0237.9Good90.8I1001
NBI reportRMP I80E TO US395NI 80RENOConcrete Box Beam or girders - Single or Spread (4 spans)--1969--79.1228.0Good91.3I1087
NBI reportRMP I80W TO US395NNINTH STRENOConcrete Box Beam or girders - Single or Spread (3 spans)--1969--79.1152.9Good95.2I1173
NBI reportRMP US395N TO I80WI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1969--84.0230.0Fair92.7I1088
NBI reportRMP US395S-I80E&WNINTH STRENOConcrete Box beam or girders - Multiple (3 spans)--1969--82.0163.1Good92.1I1171
NBI reportUS 395I 80RENOConcrete Box beam or girders - Multiple (4 spans)--1969--78.1247.1Good81.0I1086
NBI reportUS 395RMP 80W TO 395S, 9TH STRENOConcrete Box beam or girders - Multiple (4 spans)--1969--65.0200.1Fair72.6I1172
NBI reportI 80SR 666 SUTRO STRENOSteel Box beam or girders - Multiple--1970--120.1124.0Fair69.6H 999
NBI reportI 80WELLS AVRENOSteel Box beam or girders - Multiple--1970--129.9133.9Fair70.0I 998
NBI reportVALLEY RDI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1970--71.9225.1Good79.2H 997
NBI reportVIRGINIA STI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1970--71.9200.1Fair71.8H 993
NBI reportWASHINGTON STI 80RENOConcrete Box beam or girders - Multiple (4 spans)--1970--71.9249.0Good84.6H 990
NBI reportI 580SR647 4TH ST, SPRRRENOSteel Stringer/Multi-beam or girder (6 spans)--1971--95.1461.0Fair88.6G1233
NBI reportI 580SR667 & TRUCKEE RVRRENOSteel Stringer/Multi-beam or girder (3 spans)--1971--180.1495.1Fair78.2H1234
NBI reportI 580 RAMPSR647 4TH ST, SPRRRENOSteel Stringer/Multi-beam or girder (6 spans)--1971--95.1450.2Fair92.0G1233L
NBI reportI 580 RAMPSR647 4TH ST, SPRRRENOSteel Stringer/Multi-beam or girder (6 spans)--1971--95.1460.0Fair80.5G1233R
NBI reportI 80OVERFLOW RELIEF CULVERTRENOConcrete Culvert (2 spans)--1971--9.822.0Fair70.0B1349
NBI reportPARR BLUS 395RENOPrestressed Box beam or girders - Multiple (2 spans)--1971--96.1256.9Fair85.9I1306
NBI reportSR659 McCARRAN BLCOMSTOCK DRRENOConcrete Slab (3 spans)--1973--44.0116.1Fair88.8H1130
NBI reportVINE STI 80RENOSteel Box beam or girders - Multiple (5 spans)--1973--207.0770.1Good94.7H1199
NBI reportKUENZLI STTRUCKEE RIVERRENOSteel Stringer/Multi-beam or girder (2 spans)--1974--127.6221.8Fair96.6B1327W
NBI reportSECOND STTRUCKEE RIVERRENOSteel Stringer/Multi-beam or girder--1974--155.8159.1Good96.8B1326E
NBI reportMAYBERRY DRTRUCKEE RIVERWEST OF RENOSteel Stringer/Multi-beam or girder (3 spans)--1975--130.6248.0Fair73.6B1487
NBI reportI 580VASSAR STRENOPrestressed Box beam or girders - Multiple--1977--115.2117.1Good89.1H1251
NBI reportI 580MILL STRENOSteel Box beam or girders - Multiple--1977--187.0192.9Fair92.5I1252
NBI reportI 80ESR 659 W McCARRANWEST OF RENOPrestressed Box beam or girders - Multiple--1977--180.1183.1Good96.1I1301E
NBI reportI 80WSR 659 McCARRAN BLWEST OF RENOPrestressed Box beam or girders - Multiple--1977--180.1183.1Fair96.1I1301W
NBI reportSUMMIT RIDGESR659 McCARRAN BLWEST OF RENOPrestressed Box Beam or girders - Single or Spread--1977--175.9180.1Fair97.0H1553
NBI reportI 580SR648 GLENDALE AVRENOSteel Box beam or girders - Multiple--19772011160.1165.0Good93.5I1253
NBI reportWHITE FIR STTRUCKEE RIVERWEST OF RENOConcrete Box beam or girders - Multiple (3 spans)--1978199375.1164.1Fair74.5B2046
NBI reportI 580PECKHAM LNRENOPrestressed Box beam or girders - Multiple--1980--118.1120.1Good83.0H1247
NBI reportI 580MOANA LNRENOPrestressed Box beam or girders - Multiple--1980--140.1142.1Good90.5I1248
NBI reportI 580SR653 PLUMB LNRENOConcrete Box beam or girders - Multiple (12 spans)--1980--141.11543.1Fair61.3I1250
NBI reportJOY LAKE RDGALENA CRKSOUTHWEST RENOConcrete Arch - Deck--1981--100.1100.1Fair100.0B1828
NBI reportUS 395NUPRRNORTH OF RENOPrestressed Box beam or girders - Multiple--1981--131.9133.9Good99.4G1697N
NBI reportUS 395SUPRRNORTH OF RENOPrestressed Box beam or girders - Multiple--1981--128.9130.9Good99.4G1697S
NBI reportI 580SR659 McCARRAN BLSOUTH RENOSteel Stringer/Multi-beam or girder (2 spans)--1986--107.0217.9Fair74.4H1798
NBI reportI 580SR430 S VIRGINIA STRENOSteel Stringer/Multi-beam or girder (2 spans)--1986--126.0250.3Fair74.4I1799
NBI reportSR 667/DELMONTE LNEVANS CREEKRENOConcrete Culvert (2 spans)--1986--14.129.9Fair83.0B1801
NBI reportSR430 S VIRGINIAEVANS CRKRENOConcrete Culvert (2 spans)--1986--11.224.0Good78.8B1814
NBI reportBRIDLEWOOD DRIVEALUM CREEKWEST OF RENOPrestressed Tee beam (3 spans)--1988--26.981.0Good71.1B2248
NBI reportCOUNTRY ESTATES CIDRY CREEKRENOConcrete Culvert (4 spans)--1988--12.151.8Good96.9B1832
NBI reportI 580DRY CRKSOUTH RENOConcrete Culvert (4 spans)--1988--15.165.9Good76.7B1829
NBI reportI 580SR667 NEIL RDRENOSteel Stringer/Multi-beam or girder--1988--123.0128.0Good76.1I1800
NBI reportMAYBERRY DRIVEALUM CREEKWEST OF RENOConcrete Culvert--1988--24.024.9Good94.9B2249
NBI reportRMP I 580S TO RTIARMP PLUMB TO I580SRENOSteel Stringer/Multi-beam or girder (2 spans)--1988--109.9310.1Fair90.6I1773
NBI reportRMP I 580S TO RTIAI 580, TERMINAL WYRENOSteel Stringer/Multi-beam or girder (4 spans)--1988--149.9540.1Fair95.7I1774
NBI reportRMP RTIA TO I 580NTERMINAL WYRENOPrestressed Box Beam or girders - Single or Spread (9 spans)--1988--131.91110.0Fair96.3I1772
NBI reportSR 671/HUFFAKER LNDRY CREEKRENOConcrete Culvert (3 spans)--1988--15.149.9Fair55.2B1833
NBI reportUS 395NUPRRNORTH OF RENOPrestressed Box beam or girders - Multiple (3 spans)--1988--82.0208.0Good91.1G1748N
NBI reportUS 395SUPRRNORTH OF RENOPrestressed Box beam or girders - Multiple (3 spans)--1988--73.2185.0Good98.1G1748S
NBI reportI 580SR671 HUFFAKER LNSOUTH RENOSteel Stringer/Multi-beam or girder--1989--89.9105.0Good85.4H1830
NBI reportI 580SR430 S VIRGINIA STRENOSteel Stringer/Multi-beam or girder (2 spans)--1989--190.0365.2Good79.0I1831
NBI reportKIRMAN AVTRUCKEE RIVERREN0Steel Stringer/Multi-beam or girder (2 spans)--1989--105.0212.9Fair79.9B1863
NBI reportNEIL RDDRY CREEKSOUTH EAST OF RENOConcrete Culvert--1990--24.024.9Fair97.6B2622
NBI reportSR 659/MCCARRANUPRR & TRUCKEE RIVERWEST RENOSteel Stringer/Multi-beam or girder (4 spans)--1990--165.0539.1Fair96.3G1864
NBI reportEVANS CREEK DREVANS CRKSW RENOConcrete Culvert--1991--24.324.3Poor70.0B2698
NBI reportI 80SR657 KEYSTONE AVRENOSteel Box beam or girders - Multiple--1991--209.0214.9Good98.0I 987
NBI reportMIRA LOMASTEAMBOAT CREEKSTEAMBOATConcrete Culvert (3 spans)--1991--16.150.9Fair95.6B1953
NBI reportMIRA LOMASTEAMBOAT CRKSTEAMBOATConcrete Culvert (6 spans)--1991--16.1101.1Fair95.4B1954
NBI reportWELLS AV4TH&5TH, SPRR, TRUCKEERENOPrestressed Box beam or girders - Multiple (14 spans)--1991--225.11727.1Fair98.3G1276
NBI reportCAUGHLIN PWALUM CRKCAUGHLIN RANCHPrestressed Tee beam (3 spans)--1992--26.281.0Fair65.9B2456
NBI reportSR659 W.McCARRANALUM CRKRENO, NEAR CAUGHLIN RNCHConcrete Culvert (3 spans)--1992--14.846.3Fair85.0B2457
NBI reportGATEWAY DRTHOMAS CRKSOUTHEAST RENOConcrete Culvert--1993--20.020.3Good98.0B2549
NBI reportGATEWAY DRTHOMAS CRKSOUTHEAST RENOConcrete Culvert (2 spans)--1993--11.826.6Fair98.0B2550
NBI reportROBB DRI 80WEST RENOSteel Stringer/Multi-beam or girder (2 spans)--1993--154.9285.1Fair96.9I1922
NBI reportBOOTH STREETTRUCKEE RIVERRENOPrestressed Slab (2 spans)--1994--64.0126.3Fair96.7B1621
NBI reportDANT BLVDOVERFLOW CULVERTNORTH OF MANZANITA LNConcrete Culvert (2 spans)--1994--11.824.0Good97.0B2453
NBI reportTHOMAS CREEK RDWHITE'S CRKNORTH OF MT ROSE HWConcrete Culvert--1994--24.024.0Fair97.0B2452
NBI reportUS 395&ON/OFF RAMPTHOMAS CRKRENOConcrete Culvert (2 spans)--1994--9.821.0Good85.0B1943
NBI reportDBL DIAMOND PWTHOMAS CRKSOUTHEAST RENOConcrete Culvert (11 spans)--1995--9.8114.8Good88.8B2454
NBI reportI 580WHITES CRKRENOConcrete Culvert (2 spans)--1995--15.732.2Fair82.4B2030
NBI reportI 580OLD VIRGINIA RDRENOPrestressed Box Beam or girders - Single or Spread--1995--88.990.9Fair92.4H2008
NBI reportI 580SR430 S VIRGINIA STRENOPrestressed Box beam or girders - Multiple (2 spans)--1995--140.1245.1Good95.8I1950
NBI reportI 580DAMONTE RANCH PWRENOPrestressed Box beam or girders - Multiple--1995--214.9217.9Good91.7I1951
NBI reportI 580SOUTH MEADOWS PKWYRENOPrestressed Box Beam or girders - Single or Spread (2 spans)--1995--152.9277.9Good89.6I1952
NBI reportRMP S VA TO US395NOLD VIRGINIA RDRENOPrestressed Box Beam or girders - Single or Spread--1995--102.0104.0Good98.1I2007
NBI reportRMP US 395-S VA STOLD VIRGINIA RDRENOPrestressed Box Beam or girders - Single or Spread--1995--87.989.9Good99.8I2009
NBI reportSOUTH MEADOWS PWTHOMAS CRKSOUTHEAST RENOConcrete Culvert (6 spans)--1995--11.572.2Good82.0B2455
NBI reportUS 395WHITES CRKRENOConcrete Culvert (3 spans)--1995--12.139.0Good74.2B2022
NBI reportUS 395WHITES CRKRENOConcrete Culvert (3 spans)--1995--12.139.0Fair73.1B2023
NBI reportCAUGHLIN PWALUM CRK200 Y E. OF HAWKEN ROADConcrete Culvert--1997--24.324.3Fair100.0B2450
NBI reportRMP I 580SR430 VIRGINIA STRENOSteel Stringer/Multi-beam or girder (2 spans)--1997--105.0210.3Fair98.7I1799R
NBI reportARROWCREEK PWCHANNELSOUTH WEST OF RENOConcrete Culvert (3 spans)--1998--9.832.2Good83.6B2464
NBI reportARROWCREEK PWWHITES CRKSOUTH WEST OF RENOConcrete Culvert (3 spans)--1998--26.683.7Fair98.5B2468
NBI reportARROWCREEK PWWHITES CRKSOUTH WEST OF RENOConcrete Culvert (2 spans)--1998--10.221.7Fair98.5B2469
NBI reportARROWCREEK PWWHITES CRKSOUTH WEST OF RENOConcrete Culvert--1998--19.721.3Good96.3B2470
NBI report
Bridgehunter
CENTER STTRUCKEE RIVERRENOPrestressed Box beam or girders - Multiple (3 spans)--1998--64.0165.0Fair95.6B1533
NBI reportDOUBLE R BLLUMBERJACK CHNLSOUTHEAST RENOConcrete Culvert (2 spans)--1998--12.524.6Good84.3B2528
NBI reportTERABYTE CTTHOMAS CRKSOUTHEAST RENOConcrete Culvert (3 spans)--1998--8.226.2Good86.5B2531
NBI reportWEDGE PWWHITE CRK BRANCHSOUTHWEST OF RENOConcrete Culvert (4 spans)--1998--7.932.5Fair84.7B2465
NBI reportWEDGE PWWHITE CRK BRANCHSOUTHWEST OF RENOConcrete Culvert (3 spans)--1998--9.832.5Fair99.7B2466
NBI reportWEDGE PWWHITES CRKSOUTH WEST OF RENOConcrete Culvert (3 spans)--1998--9.831.8Good98.7B2467
NBI reportDOUBLE R BLTHOMAS CRKSOUTH EAST RENOConcrete Culvert (2 spans)--1999--9.820.7Good82.0B2527
NBI reportOLD VIRGINIA RDWHITES CRKSOUTH RENOConcrete Culvert (4 spans)--1999--13.160.0Fair82.0B2580
NBI reportRANGE VIEW LNEVANS CRKSOUTHWEST RENOConcrete Culvert--1999--24.926.6Fair98.0B2636
NBI reportRMP McCARRAN-395NRMP US395N-CLEARACRENORTH OF RENOPrestressed Slab--1999--27.653.2Good99.5I1305R
NBI reportTERABYTE CTTHOMAS CRKSOUTHEAST RENOConcrete Culvert (2 spans)--1999--11.524.6Good97.0B2529
NBI reportTERABYTE CTTHOMAS CRKSOUTH EAST RENOConcrete Culvert (3 spans)--1999--9.824.9Good97.0B2530
NBI reportVENTANA PWTHOMAS CRKSOUTHWEST RENOConcrete Culvert--1999--34.536.1Good80.8B2637
NBI reportDOUBLE R BLCHANNELSE RENOConcrete Culvert (5 spans)--2000--10.554.8Fair80.0B2652
NBI reportSIERRA CENTER PWDRY CREEKSOUTHWEST RENOConcrete Arch - Deck (3 spans)--2000--36.1110.2Fair98.0B2650
NBI reportSR341 GEIGER GRADESTEAMBOAT CRKSOUTH EAST OF RENOPrestressed Box beam or girders - Multiple--2000--132.2134.5Fair85.0B 624
NBI reportSR430 VIRGINIA STDRY CREEKSOUTH WESTConcrete Culvert (3 spans)--2000--11.840.7Fair82.0B2621
NBI reportDAMONTE RANCH PKWYCHANNELSE RENOConcrete Culvert (5 spans)--2001--12.565.9Good96.9B2734
NBI reportSTEAMBOAT PKWY NCHANNELSE RENOConcrete Culvert (5 spans)--2001--12.162.7Good81.8B2732
NBI reportSTEAMBOAT PS-SCHANNELSE RENOConcrete Culvert (2 spans)--2002--9.820.3Good96.7B2764
NBI reportSTEAMBOAT PW-NSTEAMBOAT CRKSE RENOConcrete Arch - Deck--2002--74.874.8Good82.2B2733
NBI reportARROWSPRINGS DRDRAINAGES RENOConcrete Culvert (3 spans)--2006--12.138.4Fair81.1B2892
NBI reportEVANS AVUPRRRENOPrestressed Slab--2006--53.856.8Good96.9G2777
NBI reportKEYSTONE AVUPRRRENOPrestressed Slab--2006--53.857.1Fair95.0G2766
NBI reportLAKE STUPRRRENOPrestressed Slab--2006--53.856.8Good80.6G2776
NBI reportLOGAN RIDGE TRCHANNELSOMERSETTConcrete Culvert (2 spans)--2006--10.220.7Good93.9B2839
NBI reportN ARLINGTON AVUPRRRENOPrestressed Slab--2006--53.856.8Good96.4G2771
NBI reportN CENTER STUPRRRENOPrestressed Slab--2006--53.856.8Good96.5G2775
NBI reportN VIRGINIA STUPRRRENOPrestressed Slab--2006--53.856.8Good79.1G2774
NBI reportRALSTON STUPRRRENOPrestressed Slab--2006--53.856.8Good96.9G2769
NBI reportRIO WRANGLER PWYDRAINAGESE RENOConcrete Culvert (3 spans)--2006--9.831.2Good82.9B2889
NBI reportRIO WRANGLER PWYDRAINAGESE RENOConcrete Culvert (3 spans)--2006--9.832.2Good81.6B2890
NBI reportRIO WRANGLER PWYDRAINAGES RENOConcrete Culvert (4 spans)--2006--12.149.9Good98.0B2891
NBI reportSIERRA STUPRRRENOPrestressed Slab--2006--53.856.8Good98.4G2773
NBI reportSOUTH MEADOWS PWSTEAMBOAT CRKRENOConcrete Culvert (4 spans)--2006--16.771.5Good81.5B2831
NBI reportSR659 McCARRAN BLVUS 395NE RENOPrestressed Box Beam or girders - Single or Spread (2 spans)--2006--129.6261.8Good90.2I1305
NBI reportUS 395NSR443 CLEARACRE LNNORTH RENOPrestressed Box beam or girders - Multiple (2 spans)--2006--79.1150.3Good100.0I1091N
NBI reportUS 395SSR443 CLEARACRE LNNORTH RENOPrestressed Box beam or girders - Multiple (2 spans)--2006--79.1150.3Good99.0I1091S
NBI reportVETERANS PWSTEAMBOAT CREEKSE RENOConcrete Culvert (7 spans)--2006--14.1103.7Fair98.0B2887
NBI reportVETERANS PWDRAINAGESE RENOConcrete Culvert (7 spans)--2006--14.1101.7Fair82.9B2888
NBI reportVINE STUPRRRENOPrestressed Slab--2006--53.856.8Good96.8G2767
NBI reportWASHINGTON STUPRRRENOPrestressed Slab--2006--53.856.8Fair96.9G2768
NBI reportWEST STUPRRRENOPrestressed Slab--2006--53.856.8Fair96.9G2772
NBI reportCARAT AVESTEAMBOAT CREEKSE RENOConcrete Culvert (9 spans)--2007--12.1113.5Good98.0B2899
NBI reportAIRWAY DRDRY CREEK CHANNELSE RENOConcrete Culvert (3 spans)--2008--27.988.9Good84.9B2930
NBI reportVETERANS PW NBSTEAMBOAT CREEKSE RENOConcrete Culvert (10 spans)--2008--15.1176.5Good99.8B2900