Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | CSX RR (340324P) | CS 813 NORTH AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1904 | -- | 49.9 | -- | -- | -- | 000000012151810 |
NBI report | NOR SOU RAILROAD | M9315 INTERNATIONAL BLVD | IN ATLANTA | Concrete Arch - Deck | -- | 1904 | -- | 38.1 | -- | -- | -- | 000000012105350 |
NBI report | US 29-CSX RR-M9124 | ABANDONED RAILROAD | IN WEST ATLANTA | Concrete Frame (3 spans) | -- | 1905 | -- | 15.1 | 45.9 | Fair | 56.8 | 000000012100470 |
NBI report | CSX RR- PRIVATE DR | M-9180 BOULEVARD | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1906 | -- | 34.1 | -- | -- | -- | 000000012105270 |
NBI report Bridgehunter | DONALD LEE HOLLOWE | CSX RR SPUR (ABANDONED) | IN W ATLANTA | Concrete Frame | -- | 1906 | -- | 35.1 | 35.1 | Fair | 69.4 | 000000012106740 |
NBI report Bridgehunter | GORDON STREET | ABANDONED RAILROAD | IN W ATLANTA | Concrete Slab (2 spans) | NR eligible | 1906 | -- | 18.0 | 35.1 | Fair | 73.0 | 000000012100820 |
NBI report | PED. BRIDGE | SR 8 PONCE DE LEON | IN ATLANTA | Steel Girder and floorbeam system | -- | 1906 | -- | 90.9 | -- | -- | -- | 000000012104910 |
NBI report | CSX RR (638657U) | CR 1903 JONES AVE. | IN CITY OF ATLANTA | Steel Girder and floorbeam system | -- | 1907 | -- | 55.1 | -- | -- | -- | 000000012151360 |
NBI report | PEDESTRIAN: ATLANT | M-9134 M.L.K. JR DRIVE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1911 | -- | 58.1 | -- | -- | -- | 000000012105200 |
NBI report | COLLIER ROAD | TANYARD CREEK | IN N ATLANTA | Concrete Tee beam (3 spans) | -- | 1911 | 1950 | 29.9 | 89.9 | Fair | 78.4 | 000000012104360 |
NBI report | CSX RR (279968D) | CR 2080 ESTORIA STREET | IN EAST ATLANTA | Concrete Slab | -- | 1912 | -- | 18.0 | -- | -- | -- | 000000012151480 |
NBI report Bridgehunter | JOHNSON ROAD | PROCTOR CREEK | IN W ATLANTA | Concrete Arch - Deck | NR eligible | 1912 | -- | 61.0 | 61.0 | Fair | 58.9 | 000000012103560 |
NBI report | CSX RAILROAD US 1 | SR 3 METROPOLTAIN AVE. | 1.4 MI S OF I-20 | Steel Stringer/Multi-beam or girder | -- | 1914 | -- | 56.1 | -- | -- | -- | 000000012105390 |
NBI report | CSX RR (50308E) | M-9182 ORMEWOOD AVE. | IN CITY OF ATLANTA | Concrete Arch - Deck | -- | 1914 | -- | 63.0 | -- | -- | -- | 000000012105280 |
NBI report | CSX RR (50309L) | M-9175 CONFEDERATE AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1914 | -- | 34.1 | -- | -- | -- | 000000012105260 |
NBI report | NOR SOU RR (718052 | CS 2429 GLENN STREET | IN CITY OF ATLANTA | Concrete Tee beam | -- | 1914 | -- | 46.9 | -- | -- | -- | 000000012151680 |
NBI report Bridgehunter | PEACHTREE STREET | CSX RAILROAD | IN N ATLANTA | Concrete Tee beam (3 spans) | NR eligible | 1914 | -- | 39.0 | 113.9 | Fair | 47.4 | 000000012100280 |
NBI report Bridgehunter | PARK DRIVE | PEDESTRIAN WALKWAY | PIEDMONT PK RR717941E | Concrete Arch - Deck | NR eligible | 1916 | -- | 73.2 | 216.9 | Fair | 60.3 | 000000012150880 |
NBI report Bridgehunter | BOHLER ROAD | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | NR eligible | 1916 | 1946 | 44.0 | 88.9 | Fair | 77.8 | 000000012103980 |
NBI report Bridgehunter | CSX RAILROAD | SR 92 E. CAMPBELLTON ST. | IN THE CITY OF FAIRBURN | Concrete Slab | -- | 1917 | -- | 18.0 | -- | -- | -- | 000000012105020 |
NBI report Bridgehunter | CSX RR (50386L) | M-9379 COLE STREET | FAIRBURN CITY LIMITS | Concrete Slab | -- | 1917 | -- | 24.0 | -- | -- | -- | 000000012105100 |
NBI report | CSX RR (50401L) | CS 2062 THORNTON AVE. | PALMETTO CITY LIMITS | Concrete Slab | -- | 1918 | -- | 21.0 | -- | -- | -- | 000000012151660 |
NBI report | CSX RR (50402T) | FAS 846 FAYETTEVILLE RD | PALMETTO CITY LIMITS | Concrete Slab | -- | 1918 | -- | 18.0 | -- | -- | -- | 000000012105110 |
NBI report | CSX RR (50403A) | CS 2020 CHURCH STREET | PALMETTO CITY LIMITS | Concrete Slab | -- | 1918 | -- | 18.0 | -- | -- | -- | 000000012151610 |
NBI report | COCHRAN ROAD | CAMP CREEK | 8 MI NW OF FAIRBURN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1920 | -- | 41.0 | 82.0 | Fair | 39.9 | 000000012151200 |
NBI report | CONVYER BELT | CR 2080 KROG STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 24.9 | -- | -- | -- | 000000012152320 |
NBI report | HARBIN ROAD | SOUTH UTOY CREEK | IN W ATLANTA CITY LIMIT | Concrete Slab (3 spans) | -- | 1920 | -- | 9.8 | 29.9 | Fair | 69.6 | 000000012151280 |
NBI report | SIMPSON STREET | PROCTOR CREEK | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1923 | 1958 | 24.0 | 24.0 | Fair | 77.7 | 000000012103320 |
NBI report Bridgehunter | TED TURNER DRIVE ( | NS-CSX RR (340316X) | DOWNTOWN ATLANTA | Steel Girder and floorbeam system (6 spans) | -- | 1923 | 2015 | 216.9 | 1537.1 | Poor | 40.0 | 000000012100100 |
NBI report Bridgehunter | MCDONOUGH BLVD. | NORFOLK-SOUTHERN RR | .3 MI E OF SR 54 | Concrete Tee beam (4 spans) | NR eligible | 1924 | -- | 45.9 | 170.0 | Poor | 47.1 | 000000012100510 |
NBI report Bridgehunter | MONTGOMERY FERRY D | CLEAR CREEK | IN ATLANTA | Masonry Arch - Deck (3 spans) | NR eligible | 1924 | -- | 15.1 | 44.9 | Fair | 75.3 | 000000012104330 |
NBI report Bridgehunter | MOORES MILL ROAD | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | NR eligible | 1924 | -- | 37.1 | 181.1 | Fair | 75.8 | 000000012103250 |
NBI report Bridgehunter | RIDGEWOOD ROAD | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | NR eligible | 1924 | -- | 40.0 | 80.1 | Fair | 75.7 | 000000012104390 |
NBI report | CSX RR (279969K) | M-9165 HILL STREET | IN ATLANTA | Concrete Slab | -- | 1925 | -- | 39.0 | -- | -- | -- | 000000012105230 |
NBI report | LOTUS AVE. | PROCTOR CREEK TRIB | IN N W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 26.9 | 26.9 | Fair | 59.7 | 000000012151540 |
NBI report | NOR SOU RR (717935 | M-9045 RALPH McGILL BLVD | IN EAST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1926 | -- | 80.1 | -- | -- | -- | 000000012105150 |
NBI report | NORTHSIDE DRIVE | PEACHTREE CREEK | IN NORTH ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1926 | -- | 43.0 | 125.0 | Fair | 41.2 | 000000012100130 |
NBI report | CENTRAL AVE. | GA RR- CSX RR- MARTA | IN ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1926 | 1978 | 65.9 | 532.2 | Fair | 54.8 | 000000012104170 |
NBI report | CSX RAILROAD | CS2103 FULTON TERRACE ST | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 29.9 | -- | -- | -- | 000000012151900 |
NBI report | CSX RR (50311M) | M-9165 HILL STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 35.1 | -- | -- | -- | 000000012105220 |
NBI report | FAIRBURN ROAD | SOUTH UTOY CREEK | 7 MI W OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 40.0 | 40.0 | Fair | 68.4 | 000000012103430 |
NBI report | FAIRBURN ROAD | NORTH UTOY CREEK | 7 MI W OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 40.0 | 40.0 | Fair | 69.2 | 000000012103440 |
NBI report | LONG ISLAND DRIVE | LONG ISLAND CREEK | .6 MI N OF MT PARAN ROAD | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 32.2 | 32.2 | Fair | 66.2 | 000000012104560 |
NBI report | NORTH IVY ROAD | NANCY CREEK TRIB | IN NORTH ATLANTA | Concrete Culvert (2 spans) | -- | 1927 | -- | 14.1 | 29.9 | Good | 92.4 | 000000012151920 |
NBI report | NORTH IVY ROAD | NANCY CREEK TRIB | IN NORTH ATLANTA | Concrete Culvert (2 spans) | -- | 1927 | -- | 14.1 | 27.9 | Fair | 83.9 | 000000012151930 |
NBI report | WEST WESLEY ROAD | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | NR eligible | 1927 | -- | 29.9 | 60.0 | Fair | 74.8 | 000000012103990 |
NBI report | WIEUCA ROAD | NANCY CREEK TRIB | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 30.8 | 30.8 | Fair | 80.4 | 000000012104490 |
NBI report | WALL STREET | LOWER WALL ST PARKING LO | IN ATLANTA | Steel Stringer/Multi-beam or girder (8 spans) | NR eligible | 1927 | 1999 | 68.9 | 665.1 | Fair | 70.4 | 000000012151630 |
NBI report | CLAIRE DRIVE | SOUTH RIVER TRIB | IN LAKEWOOD HIGHTS | Steel Stringer/Multi-beam or girder | -- | 1928 | -- | 29.9 | 29.9 | Fair | 80.2 | 000000012105820 |
NBI report | NOR SOU RR (717914 | M-9215 LINDBERGH DRIVE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1928 | -- | 35.1 | -- | -- | -- | 000000012105070 |
NBI report Bridgehunter | NORTHSIDE DRIVE | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | NR eligible | 1928 | -- | 38.1 | 99.1 | Fair | 93.5 | 000000012104420 |
NBI report | PACES FERRY ROAD | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1928 | -- | 37.1 | 91.9 | Fair | 84.5 | 000000012103290 |
NBI report | RANDALL MILL ROAD | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1928 | -- | 37.1 | 74.2 | Fair | 84.6 | 000000012151780 |
NBI report | WIEUCA ROAD | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1928 | -- | 34.1 | 67.9 | Fair | 92.0 | 000000012104500 |
NBI report | COLLIER ROAD | CSX RAILROAD (639818R) | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1928 | 1960 | 39.0 | 90.9 | Fair | 74.3 | 000000012104370 |
NBI report Bridgehunter | ROSWELL ROAD | CHATTAHOOCHEE RIVER | 1.1 MI S OF SR 120 | Concrete Arch - Deck (9 spans) | NR possible | 1928 | 1965 | 70.9 | 627.0 | Fair | 64.5 | 000000012100330 |
NBI report | BROWNS MILL ROAD | SOUTH RIVER | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1929 | -- | 32.2 | 64.0 | Fair | 77.2 | 000000012103760 |
NBI report | BROWNS MILL ROAD | SOUTH RIVER TRIB | IN SOUTHWEST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 24.0 | 24.0 | Fair | 72.2 | 000000012105760 |
NBI report | DODSON DRIVE | SOUTH UTOY CREEK | IN S.W. ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 40.0 | 40.0 | Fair | 67.8 | 000000012103190 |
NBI report | FAIRBURN ROAD | SANDY CREEK | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 28.9 | 28.9 | Fair | 77.8 | 000000012103470 |
NBI report | PRYOR STREET | CSX RR (340311N) | IN ATLANTA | Steel Girder and floorbeam system (5 spans) | NR eligible | 1929 | -- | 54.1 | 726.1 | Fair | 65.3 | 000000012151750 |
NBI report | SPALDING DRIVE | BALL MILL CREEK | 4 MI SE OF ROSWELL | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 34.1 | 34.1 | Good | 75.9 | 000000012150300 |
NBI report | WINDSOR PARKWAY | NANCY CREEK | 2.2 MI E OF JCT SR 9 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1929 | -- | 29.9 | 60.0 | Fair | 61.9 | 000000012104580 |
NBI report | LYNHURST DRIVE | NORTH UTOY CREEK | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1929 | 1956 | 34.1 | 34.1 | Fair | 77.7 | 000000012103510 |
NBI report | CONSTITUTION ROAD | SOUTH RIVER TRIB | IN SOUTH EAST ATLANTA | Concrete Culvert (2 spans) | -- | 1930 | -- | 13.1 | 26.9 | Good | 91.8 | 000000012105770 |
NBI report Bridgehunter | DONALD LEE HOLLOWA | PROCTOR CREEK | IN W ATLANTA | Concrete Arch - Deck | NR eligible | 1930 | -- | 45.9 | 45.9 | Fair | 58.7 | 000000012100200 |
NBI report | DECATUR STREET | M-9180 BOULEVARD | IN ATLANTA | Steel Stringer/Multi-beam or girder | NR eligible | 1930 | 1949 | 33.1 | 49.9 | Fair | 89.2 | 000000012104100 |
NBI report | DUNWOODY CLUB DR. | BALL CREEK | 7.2 MI S OF ALPHARETTA | Steel Stringer/Multi-beam or girder | -- | 1931 | -- | 24.0 | 24.0 | Fair | 69.9 | 000000012102930 |
NBI report | FRANCIS PLACE | PROCTOR CREEK | IN W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1931 | -- | 36.1 | 36.1 | Fair | 75.8 | 000000012150940 |
NBI report | HOLLYWOOD ROAD | PROCTOR CREEK TRIB | IN N W ATLANTA | Concrete Culvert (2 spans) | -- | 1931 | -- | 9.8 | 22.0 | Good | 76.8 | 000000012105740 |
NBI report | HOLLYWOOD ROAD | PROCTOR CREEK TRIB | IN N W ATLANTA | Concrete Culvert (2 spans) | -- | 1931 | -- | 9.8 | 22.0 | -- | -- | 000000012153860 |
NBI report | NORTHSIDE DRIVE | LONG ISLAND CREEK | 2.3 MI S OF I-285 | Steel Stringer/Multi-beam or girder | -- | 1931 | -- | 36.1 | 36.1 | Fair | 87.2 | 000000012104430 |
NBI report | PEYTON ROAD | NORTH UTOY CREEK | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1931 | -- | 24.9 | 24.9 | Fair | 81.8 | 000000012152360 |
NBI report | US 19 PEACHTREE ST | PEACHTREE CREEK | IN N ATLANTA | Concrete Tee beam (5 spans) | NR eligible | 1931 | -- | 39.0 | 181.1 | Fair | 70.7 | 000000012100290 |
NBI report | WOODLAND ROAD | INTRENCHMENT CREEK | 3 MI SE OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 42.0 | 42.0 | Fair | 49.7 | 000000012151150 |
NBI report Bridgehunter | BROOKRIDGE DRIVE | CLEAR CREEK | IN ATLANTA | Concrete Arch - Deck | NR eligible | 1934 | -- | 29.9 | 29.9 | Good | 65.8 | 000000012150870 |
NBI report | HERCHELL ROAD | CAMP CREEK | AT COLLEGE PARK | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 26.9 | 26.9 | Fair | 64.8 | 000000012103170 |
NBI report | LAKE FOREST DRIVE | LONG ISLAND CREEK | 8 MI S OF ROSWELL | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 29.9 | 29.9 | Fair | 82.9 | 000000012150360 |
NBI report | PRYOR ROAD | SOUTH RIVER TRIB | LAKEWOOD FAIR | Concrete Culvert (2 spans) | -- | 1935 | -- | 9.8 | 23.0 | Good | 76.5 | 000000012105810 |
NBI report Bridgehunter | SR 14, PETERS STRE | NS RAILROAD | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1935 | -- | 120.1 | 995.1 | Fair | 50.5 | 000000012100490 |
NBI report | CAMPBELLTON RD | SOUTH UTOY CREEK | IN EAST POINT | Steel Stringer/Multi-beam or girder | -- | 1935 | 1945 | 58.1 | 58.1 | Fair | 75.2 | 000000012103540 |
NBI report | BOLTON ROAD | WHETSTONE CREEK | IN N ATLANTA | Concrete Culvert (3 spans) | -- | 1935 | 1972 | 7.9 | 25.9 | Good | 91.9 | 000000012106830 |
NBI report | COLLIER ROAD | PEACHTREE CREEK TRIB | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1936 | -- | 41.0 | 41.0 | Fair | 53.6 | 000000012104350 |
NBI report | CSX RR (50314H) | M-9086 PRYOR ROAD | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1936 | -- | 74.2 | -- | -- | -- | 000000012105250 |
NBI report | MCDONOUGH BLVD. | NS RAILROAD (717955M) | IN CITY OF ATLANTA | Masonry Arch - Deck | -- | 1936 | -- | 26.9 | 26.9 | Fair | 66.0 | 000000012100550 |
NBI report | NORFOLK SOUTHERN R | SR 3 NORTHSIDE DRIVE | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1936 | -- | 48.9 | -- | -- | -- | 000000012104920 |
NBI report | PIEDMONT AVE. | ATLANTA BELTLINE | IN N ATLANTA | Concrete Tee beam (3 spans) | -- | 1936 | -- | 28.9 | 86.9 | Fair | 74.1 | 000000012100360 |
NBI report | SPRING STREET | PROCTOR CREEK TRIB | IN N W ATLANTA | Concrete Culvert (2 spans) | -- | 1936 | -- | 12.1 | 24.0 | Fair | 81.2 | 000000012151550 |
NBI report | MACON DRIVE | SOUTH RIVER | IN ATLANTA | Concrete Slab | -- | 1936 | 1997 | 34.1 | 34.1 | Good | 80.7 | 000000012103770 |
NBI report | CHESTER BRIDGE RD | CSX RAILROAD (639814N) | IN N ATLANTA | Steel Stringer/Multi-beam or girder | NR eligible | 1937 | -- | 61.0 | 201.1 | Fair | 70.1 | 000000012100380 |
NBI report Bridgehunter | ANDERSON AVE. | CSX RR (638640R)- MARTA | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1937 | 1977 | 59.1 | 179.1 | Fair | 69.8 | 000000012103930 |
NBI report | CHESHIRE BRIDGE RD | SOUTH FORK P'TREE CREEK | IN N ATLANTA | Concrete Tee beam (5 spans) | -- | 1938 | -- | 40.0 | 191.9 | Fair | 65.4 | 000000012100390 |
NBI report | LAKEMOORE DRIVE | NANCY CREEK TRIB. | IN NORTH ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1938 | -- | 25.9 | 25.9 | Fair | 64.4 | 000000012151250 |
NBI report | NOR SOU RAILROAD | CR 519 ARMOUR DRIVE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1938 | -- | 3.6 | -- | -- | -- | 000000012151350 |
NBI report | N'SIDE PARKWAY US | NANCY CREEK | IN N ATLANTA | Concrete Tee beam (3 spans) | -- | 1938 | 1954 | 29.9 | 86.0 | Good | 90.7 | 000000012100140 |
NBI report | US 29/ SR 14 | CSX RAILROAD | 2.6 MI NE OF UNION CITY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1938 | 1986 | 37.1 | 101.1 | Fair | 65.9 | 000000012100420 |
NBI report | NEW BULLPEN ROAD | LITTLE RIVER | FULTON-CHEROKEE COUNTY LI | Concrete Tee beam (2 spans) | -- | 1939 | -- | 30.8 | 61.0 | Fair | 60.2 | 000000012151060 |
NBI report | CHATTAHOOCHEE AVE. | CSX RR AND NS RR | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | NR eligible | 1940 | -- | 134.8 | 287.1 | Fair | 64.2 | 000000012103960 |
NBI report Bridgehunter | COCHRAN ROAD | DEEP CREEK | 8 MI NW OF FAIRBURN | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 39.0 | 39.0 | Poor | 15.4 | 000000012151190 |
NBI report Bridgehunter | MOORES MILL ROAD | CSX RAILROAD (639133L) | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | NR eligible | 1940 | -- | 38.1 | 113.9 | Fair | 56.7 | 000000012103240 |
NBI report | NOR. SOUTHERN RAIL | CS 2063 GRANT & HILLIARD | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 50.9 | -- | -- | -- | 000000012151670 |
NBI report | BRANDON MILL ROAD | MARSH CREEK | 6 MI S OF ROSWELL | Steel Stringer/Multi-beam or girder | -- | 1940 | 1966 | 29.9 | 29.9 | Fair | 75.5 | 000000012150340 |
NBI report Bridgehunter | WEST LAKE AVE. | CSX RR (638641X)- MARTA | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1940 | 1977 | 55.1 | 171.9 | Fair | 56.8 | 000000012103940 |
NBI report | CSX RAILROAD | CR 1916 JETT STREET | IN CITY OF ATLANTA | Concrete Arch - Deck | -- | 1941 | -- | 29.9 | -- | -- | -- | 000000012151390 |
NBI report | EDGEWOOD AVE. | CS 3474 AIRLINE STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1941 | -- | 44.9 | 44.9 | Fair | 71.5 | 000000012100230 |
NBI report | OLD HOLCOMB BR RD | BIG CREEK | IN EAST ROSWELL | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1941 | -- | 41.0 | 82.0 | Fair | 42.0 | 000000012151330 |
NBI report | RICKENBACKER DR | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1941 | -- | 40.0 | 80.1 | Fair | 76.4 | 000000012151260 |
NBI report | CSX RAILROAD | M-9013 BOLTON ROAD | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1942 | -- | 50.9 | -- | -- | -- | 000000012105010 |
NBI report | LAKE FOREST DRIVE | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1945 | -- | 41.0 | 82.0 | Good | 73.8 | 000000012150370 |
NBI report | BREWER BLVD. | SOUTH RIVER TRIB | IN ATLANTA | Concrete Culvert (2 spans) | -- | 1946 | -- | 9.8 | 21.0 | Good | 92.2 | 000000012152180 |
NBI report | BUTNER ROAD | CAMP CREEK | 5.8 MI W OF COLLEGE PARK | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1946 | -- | 29.9 | 89.9 | Fair | 36.2 | 000000012103550 |
NBI report | JETT ROAD | LONG ISLAND CREEK | 1 MI SE I-285 & CHATTAHOO | Steel Stringer/Multi-beam or girder | -- | 1946 | -- | 33.1 | 33.1 | Fair | 41.5 | 000000012151760 |
NBI report | POWERS FERRY RD | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1946 | -- | 44.9 | 105.0 | Fair | 66.4 | 000000012104480 |
NBI report | SPENCE ROAD | WHITE WATER CREEK | 3 MI S OF UNION CITY | Steel Stringer/Multi-beam or girder | -- | 1946 | -- | 37.1 | 37.1 | Good | 64.0 | 000000012100700 |
NBI report | CHATTAHOOCHEE AVE. | PEACHTREE CREEK TRIB | IN N W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1946 | 1960 | 26.9 | 26.9 | Good | 73.3 | 000000012103970 |
NBI report | CAMBELLTON ROAD | CSX RAILROAD | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1946 | 1987 | 44.9 | 149.9 | Fair | 78.4 | 000000012100930 |
NBI report | HOPEWELL ROAD | CHICKEN CREEK | 5.8 MI N OF ALPHARETTA | Steel Stringer/Multi-beam or girder | -- | 1948 | -- | 41.0 | 41.0 | Fair | 58.1 | 000000012102830 |
NBI report | HOWELL MILL ROAD | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1948 | -- | 49.9 | 220.2 | Poor | 15.8 | 000000012104030 |
NBI report | DEMOONEY ROAD | DEEP CREEK | 5 MI NW OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1949 | -- | 20.0 | 80.1 | Fair | 12.0 | 000000012150560 |
NBI report | CSX RR (639132E) | M-9206 DE FOORS FERRY RD | IN CITY OFATLANTA | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 40.0 | -- | -- | -- | 000000012105320 |
NBI report | LENOX ROAD | S. FORK PEACHTREE CRK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1950 | -- | 37.1 | 73.2 | Fair | 77.6 | 000000012104300 |
NBI report | NOR SOU RR (718077 | M-9053RALPH DAVID BLVD | IN WEST END | Concrete Slab | -- | 1950 | -- | 41.0 | -- | -- | -- | 000000012105160 |
NBI report | OAK DRIVE | SOUTH RIVER TRIB | IN SOUTHWEST ATLANTA | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 21.0 | Good | 92.4 | 000000012151700 |
NBI report | RIVERTOWN ROAD | LINE CREEK | .1 MI W OF FAIRBURN | Concrete Tee beam | -- | 1950 | 1977 | 30.8 | 30.8 | Good | 68.4 | 000000012102670 |
NBI report | RIVERTOWN ROAD | KING BRANCH | 1 MI W OF FAIRBURN | Concrete Tee beam | -- | 1950 | 1977 | 29.9 | 29.9 | Good | 71.5 | 000000012102680 |
NBI report | W PACES FERRY RD | NANCY CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1950 | 1986 | 33.1 | 92.9 | Good | 87.9 | 000000012104400 |
NBI report | BARNES ROAD | WHITE OAK CREEK | IN CITY OF CHATTAHOOCHEE | Concrete Channel beam | -- | 1951 | -- | 29.9 | 29.9 | Fair | 47.8 | 000000012151090 |
NBI report | BETHANY ROAD | COOPER SANDY CREEK | 3.0 MI N OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1951 | -- | 29.9 | 60.0 | Fair | 50.8 | 000000012102810 |
NBI report | CASCADE ROAD | BRANCH OF UTOY CREEK | 9 MI W OF ATLANTA | Steel Culvert (2 spans) | -- | 1951 | -- | 13.1 | 28.9 | Poor | 70.0 | 000000012100890 |
NBI report | FULTON IND. BLVD. | MORRIS CREEK | 9.3 MI N OF FAIRBURN | Concrete Culvert (3 spans) | -- | 1951 | -- | 5.9 | 21.0 | Good | 74.1 | 000000012100620 |
NBI report | FULTON IND. BLVD. | CHATTAHOOCHEE RIV TRIB | 10.7 MILES NORTH OF FAIRB | Concrete Culvert (2 spans) | -- | 1951 | -- | 11.2 | 23.0 | Good | 75.3 | 000000012100630 |
NBI report | MARIETTA STREET | SR 8 NORTH AVE. | IN NW ATLANTA | Concrete Slab (2 spans) | NR eligible | 1951 | -- | 40.0 | 74.2 | Fair | 71.6 | 000000012103200 |
NBI report | NORFOLK SOUTHERN R | NORTH AVENUE | IN ATLANTA | Concrete Tee beam | Closed | 1951 | -- | 38.1 | -- | Fair | 2.0 | 000000012104700 |
NBI report | NORFOLK SOUTHERN R | SR 8 NORTH AVENUE | IN ATLANTA | Concrete Slab | -- | 1951 | -- | 34.1 | -- | -- | -- | 000000012104960 |
NBI report | NORFOLK SOUTHERN R | SR 8 NORTH AVENUE | IN ATLANTA | Concrete Slab | -- | 1951 | -- | 34.1 | -- | -- | -- | 000000012104970 |
NBI report | NORFOLK SOUTHERN R | SR 8 NORTH AVENUE | IN ATLANTA | Concrete Slab | -- | 1951 | -- | 34.1 | -- | -- | -- | 000000012104980 |
NBI report | NORCROSS STREET | HOG WALLER CREEK | IN ROSWELL | Steel Stringer/Multi-beam or girder | -- | 1951 | 1964 | 29.9 | 29.9 | Fair | 52.9 | 000000012103090 |
NBI report | BUTNER ROAD | CAMP CREEK TRIB | 4 MI E OF SR 92 | Concrete Culvert (3 spans) | -- | 1952 | -- | 6.9 | 24.0 | Good | 90.0 | 000000012102720 |
NBI report | BUTNER ROAD | WOLF CREEK | 7.3 MI N OF UNION CITY | Concrete Culvert (3 spans) | -- | 1952 | -- | 9.8 | 32.2 | Good | 89.1 | 000000012102730 |
NBI report | CSX RAILROAD | SR 3 NORTHSIDE DRIVE | IN W ATLANTA | Concrete Slab | -- | 1952 | -- | 44.9 | -- | -- | -- | 000000012104940 |
NBI report | MARIETTA BLVD. | SPUR RAILROAD TRACK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1952 | -- | 25.9 | 78.1 | Fair | 79.4 | 000000012100060 |
NBI report | McGINNIS FERRY RD | BIG CREEK | 4.1 MI NE OF ALPHARETTA | Concrete Channel beam (5 spans) | -- | 1952 | -- | 29.9 | 149.9 | Fair | 41.1 | 000000012102860 |
NBI report | NORTHSIDE DRIVE US | CSX + NOR SOU RAILROAD | IN N FULTON | Concrete Slab (2 spans) | NR eligible | 1952 | -- | 123.0 | 161.1 | Fair | 73.2 | 000000012100030 |
NBI report | VIRGINIA AVE. | ATLANTA BELTLINE | IN ATLANTA | Concrete Slab | -- | 1952 | -- | 38.1 | 38.1 | Fair | 81.6 | 000000012104080 |
NBI report | SPALDING DRIVE | CROOKED CREEK | 6.6 MI SE OF ROSWELL | Steel Stringer/Multi-beam or girder | -- | 1952 | 1961 | 40.0 | 40.0 | Fair | 37.9 | 000000012102780 |
NBI report | CAMB.-FAIRBURN HWY | LINE CREEK | 5.1 MI NW OF FAIRBURN | Concrete Culvert (5 spans) | -- | 1953 | -- | 9.8 | 57.1 | Fair | 83.1 | 000000012100720 |
NBI report | HOPEWELL ROAD | COOPER SANDY CREEK | 2 MI N OF ALPHARETTA | Steel Culvert (2 spans) | -- | 1953 | -- | 16.1 | 35.1 | Good | 91.4 | 000000012151070 |
NBI report | MARIETTA BLVD. | CSX RAILROAD- SOU. RR. | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | NR eligible | 1953 | -- | 159.1 | 387.2 | Fair | 68.3 | 000000012100050 |
NBI report | PETERS STREET | SR 3(US 19) NORTHSIDE DR | IN W ATLANTA | Concrete Slab (2 spans) | NR eligible | 1953 | -- | 43.0 | 86.0 | Fair | 74.3 | 000000012100480 |
NBI report Bridgehunter | SR 13 | CS 519 ARMOUR DRIVE | IN N ATLANTA | Concrete Tee beam (3 spans) | -- | 1953 | 1985 | 54.1 | 128.9 | Fair | 84.6 | 000000012102070 |
NBI report | SR 13 | SR 237 PIEDMONT ROAD | IN N ATLNTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1953 | 1985 | 62.0 | 203.1 | Good | 94.6 | 000000012102080 |
NBI report | BEN. E. MAYS ROAD | NORTH UTOY CREEK | IN WEST ATLANTA | Concrete Tee beam (3 spans) | -- | 1954 | -- | 29.9 | 69.9 | Fair | 79.3 | 000000012103380 |
NBI report | CLARITY ROAD | LITTLE RIVER | 8 MI NW OF ALPHARETTA | Steel Stringer/Multi-beam or girder | -- | 1954 | -- | 47.9 | 47.9 | Fair | 29.1 | 000000012150020 |
NBI report | McGINNIS FERRY RD | CAMP CREEK TRIB | 3.2 MI NE OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1954 | -- | 29.9 | 60.0 | Fair | 54.4 | 000000012102840 |
NBI report | NORFOLK SOUTHERN R | SR 13 | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1954 | -- | 47.9 | -- | -- | -- | 000000012104880 |
NBI report | SR 13 | SR 236 LINDBERGH DRIVE | IN N ATLANTA | Concrete Tee beam (4 spans) | -- | 1954 | 1984 | 47.9 | 191.9 | Good | 94.6 | 000000012102110 |
NBI report | I-75 | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1954 | 1985 | 73.2 | 292.0 | Fair | 61.5 | 000000012101500 |
NBI report | SR 13 | NS RR.+ PTREE CRK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (11 spans) | -- | 1954 | 1985 | 65.0 | 612.9 | Fair | 96.7 | 000000012102090 |
NBI report | I-75 | CSX RAILROAD | IN ATLANTA | Concrete Tee beam (4 spans) | -- | 1954 | 1986 | 39.0 | 155.8 | Fair | 81.9 | 000000012101360 |
NBI report | HAMILTON ROAD | WHITE OAK CREEK | 7 MI NW OF PALMETTO | Concrete Channel beam (2 spans) | -- | 1954 | 1990 | 29.9 | 60.0 | Good | 80.4 | 000000012150470 |
NBI report | HUFF ROAD | NS RAILROAD (638487C) | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | -- | 38.1 | 89.9 | Fair | 61.8 | 000000012104040 |
NBI report | JOHNSON ROAD | SHOAL CREEK | 4 MI SW OF FAIRBURN | Concrete Slab (2 spans) | -- | 1955 | -- | 15.1 | 29.9 | Poor | 37.7 | 000000012150820 |
NBI report | METROPOLITAN AVE.U | SOUTH RIVER | 1.5 MI E OF EAST POINT | Concrete Culvert (3 spans) | -- | 1955 | -- | 9.8 | 32.2 | Fair | 78.3 | 000000012100020 |
NBI report | MOUNTAIN WAY RD | NANCY CREEK TRIB. | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1955 | -- | 24.9 | 24.9 | Fair | 62.4 | 000000012152350 |
NBI report | N. STRATFORD ROAD | NANCY CREEK TRIB | IN NORTH ATLANTA | Concrete Culvert (2 spans) | -- | 1955 | -- | 12.1 | 24.0 | Good | 88.9 | 000000012152340 |
NBI report | STATE BRIDGE ROAD | BIG CREEK TRIBUTARY | IN ALPHARETTA @ SR 400 | Concrete Culvert (2 spans) | -- | 1955 | -- | 9.8 | 21.0 | Good | 75.9 | 000000012100760 |
NBI report | THORNTON STREET | SOUTH RIVER TRIB | IN ATLANTA | Concrete Culvert (3 spans) | -- | 1955 | -- | 6.9 | 23.0 | Good | 92.4 | 000000012152300 |
NBI report | BUFFINGTON ROAD | MORNING CREEK | 2.3 MI E OF UNION CITY | Concrete Culvert (3 spans) | -- | 1956 | -- | 6.9 | 23.0 | Good | 91.6 | 000000012152430 |
NBI report | HUTCHENS ROAD | POOLE CREEK | 2 M W OF HAPEVILLE | Concrete Slab (5 spans) | -- | 1956 | -- | 16.1 | 80.1 | Good | 84.5 | 000000012103850 |
NBI report | OLD ALABAMA ROAD | JOHNS CREEK | 6.2 MI SE OF ALPHARETTA | Concrete Channel beam (4 spans) | -- | 1956 | -- | 29.9 | 120.1 | Fair | 60.9 | 000000012102920 |
NBI report | SR 70 SBL | UTOY CREEK | 2.7 MI S OF I-20 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1956 | -- | 35.1 | 105.0 | Fair | 68.0 | 000000012100650 |
NBI report | VERNON GROVE ROAD | LONGINO CREEK | 6 MI NW OF PALMETTO | Concrete Channel beam | -- | 1956 | -- | 29.9 | 29.9 | Good | 48.2 | 000000012150440 |
NBI report | WESTBROOK ROAD | CHICKEN CREEK TRIB | 7 MI N OF ALPHARETTA | Concrete Channel beam | -- | 1956 | -- | 29.9 | 29.9 | Fair | 52.2 | 000000012150070 |
NBI report | WESTBROOK ROAD | CHICKEN CREEK TRIB | 7 MI N OF ALPHARETTA | Concrete Channel beam | -- | 1956 | -- | 29.9 | 29.9 | Fair | 29.4 | 000000012150080 |
NBI report | WOOD ROAD | CHICKEN CREEK TRIB | 5 MI NW OF ALPHARETTA | Concrete Channel beam | -- | 1956 | -- | 29.9 | 29.9 | Fair | 49.0 | 000000012150140 |
NBI report | OLD ALABAMA ROAD | JOHNS CREEK TRIB | 5.5 MI SE OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1956 | 1962 | 29.9 | 60.0 | Fair | 50.2 | 000000012102910 |
NBI report | BARNWELL ROAD | HOGAN CREEK | 6.3 MI S OF ALPHARETTA | Steel Stringer/Multi-beam or girder | -- | 1956 | 1970 | 38.1 | 38.1 | Fair | 75.5 | 000000012102900 |
NBI report | M.L.K. JR. DRIVE | CHATTAHOOCHEE RIVER | @ CHARLIE BROWN AIRPORT | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1956 | 1979 | 100.1 | 451.1 | Fair | 92.8 | 000000012100840 |
NBI report | I-75 | M-9205 COLLIER ROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1956 | 1985 | 49.9 | 138.1 | Good | 77.7 | 000000012101490 |
NBI report | HARRIS ROAD | WHITE WATER CREEK TRIB | 2 MI SE OF FAIRBURN | Prestressed Channel beam | -- | 1957 | -- | 29.9 | 29.9 | Good | 45.4 | 000000012150790 |
NBI report | NOR SOU RR (718054 | M-9053RALPH DAVID BLVD | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1957 | -- | 43.0 | -- | -- | -- | 000000012105170 |
NBI report | PHILLIPS ROAD | LITTLE BEAR CREEK | 2 MI NW OF PALMETTO | Concrete Channel beam | -- | 1957 | -- | 29.9 | 29.9 | Fair | 48.7 | 000000012150400 |
NBI report | AUTHER LANGFORD RD | SOUTH RIVER TRIB | IN ATLANTA | Concrete Culvert (3 spans) | -- | 1958 | -- | 7.9 | 25.9 | Good | 92.4 | 000000012152290 |
NBI report | BELL ROAD | CHATTAHOOCHEE RIVER TRIB | 9 MI E OF ALPHARETTA | Concrete Channel beam | -- | 1958 | -- | 29.9 | 29.9 | Fair | 56.8 | 000000012150200 |
NBI report | CAMB.-FAIRBURN RD | CHATTAHOOCHEE RIVER | FULTON/DOUGLAS CO LINE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1958 | -- | 100.1 | 600.1 | Fair | 53.0 | 000000012100730 |
NBI report | CASCADE-PALMETTO | BEAR CREEK | 3 MI N OF PALMETTO | Concrete Tee beam (3 spans) | -- | 1958 | -- | 39.0 | 117.1 | Good | 60.5 | 000000012100870 |
NBI report | CASCADE-PALMETTO | PEA CREEK | 5.5 MI N OF PALMETTO | Concrete Culvert (3 spans) | -- | 1958 | -- | 9.8 | 34.1 | Fair | 91.7 | 000000012100880 |
NBI report | CSX RAILROAD | SR 3 NORTHSIDE DRIVE | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1958 | -- | 53.2 | -- | -- | -- | 000000012104930 |
NBI report | RIVERSIDE ROAD | BIG CREEK | IN SOUTH ROSWELL | Concrete Tee beam (4 spans) | -- | 1958 | -- | 40.0 | 160.1 | Fair | 29.5 | 000000012103040 |
NBI report | BUFFINGTON ROAD | SR 14 SPUR | 4 M NET OF UNION CITY | Concrete Tee beam (4 spans) | -- | 1959 | -- | 59.1 | 215.9 | Fair | 78.4 | 000000012103650 |
NBI report | CSX RAILROAD | SR 14 SPUR | 3.5 MI NE OF UNION CITY | Steel Stringer/Multi-beam or girder | -- | 1959 | -- | 69.9 | -- | -- | -- | 000000012105000 |
NBI report | WASHINGTON STREET | 2 I-75 RAMPS | IN ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1959 | -- | 134.8 | 443.9 | Fair | 75.5 | 000000012104160 |
NBI report | HERNDON ROAD | BEAR CREEK | 3 MI SW OF FAIRBURN | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1959 | 1990 | 29.9 | 60.0 | Good | 78.8 | 000000012150840 |
NBI report | ABBOTTS BRIDGE RD | CHATTAHOOCHEE RIVER | 8 MI E OF ALPHARETTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | -- | 79.1 | 304.1 | Fair | 66.0 | 000000012100790 |
NBI report | BISHOP ROAD | BEAR CREEK | 3 MI SW OF FAIRBURN | Concrete Channel beam (2 spans) | -- | 1960 | -- | 29.9 | 60.0 | Good | 67.3 | 000000012151160 |
NBI report | BOAT ROCK ROAD | CASCADE CREEK & FCRR | 12 MI W OF ATLANTA | Concrete Culvert (3 spans) | -- | 1960 | -- | 9.8 | 32.2 | Good | 92.4 | 000000012150530 |
NBI report | CHARLES PLACE | HOG WALLER CREEK | IN ROSWELL | Concrete Channel beam (3 spans) | -- | 1960 | -- | 29.9 | 89.9 | Fair | 65.5 | 000000012151300 |
NBI report | CSX RR (639131X) | M-9205 COLLIER ROAD | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1960 | -- | 56.1 | -- | -- | -- | 000000012105310 |
NBI report | FORREST PARK RD | SOUTH RIVER | IN SOUTH EAST ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | -- | 41.0 | 83.0 | Fair | 91.8 | 000000012103790 |
NBI report | FORREST PARK RD | NS RAILROAD (718380W) | IN SOUTH EAST ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | -- | 57.1 | 131.9 | Fair | 62.7 | 000000012152310 |
NBI report | FREEMANVILLE RD | COOPER SANDY CREEK | 1.75 MI N ALPHARETTA C.L. | Concrete Channel beam (3 spans) | -- | 1960 | -- | 29.9 | 89.9 | Fair | 52.8 | 000000012151530 |
NBI report | GREENTREE TRAIL | WOLF CREEK | 4 MI N OF UNION CITY | Concrete Culvert (3 spans) | -- | 1960 | -- | 9.8 | 32.2 | Good | 92.4 | 000000012151010 |
NBI report | LOGAN CIR. (NORTH) | PEACHTREE CREEK TRIB | IN N ATLANTA | Concrete Culvert (2 spans) | -- | 1960 | -- | 9.8 | 22.0 | Fair | 99.9 | 000000012152260 |
NBI report | LOGAN CIR. (SOUTH) | PEACHTREE CREEK TRIB | IN N ATLANTA | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 24.0 | Good | 99.9 | 000000012152270 |
NBI report | PIEDMONT ROAD | CSX RAILROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | -- | 33.1 | 98.1 | Fair | 70.2 | 000000012101100 |
NBI report | PIEDMONT ROAD | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | -- | 60.0 | 223.1 | Fair | 71.3 | 000000012101110 |
NBI report | RIVER IND. BVLD. | FEDERAL PRISON BRANCH | IN SOUTH EAST ATLANTA | Concrete Culvert (2 spans) | -- | 1960 | -- | 9.8 | 21.0 | Good | 91.4 | 000000012106860 |
NBI report | RIVERSIDE DRIVE | CHATTAHOOCHEE RIVER TRIB | 1 MI N OF JCT I-285 | Concrete Channel beam | -- | 1960 | -- | 29.9 | 29.9 | Fair | 73.0 | 000000012104530 |
NBI report | SEABOARD IND BLVD | PEACHTREE CREEK TRIB | IN N ATLANTA | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 24.9 | Good | 62.0 | 000000012152250 |
NBI report | VIRGINIA AVE. | I-85 SPUR | IN HAPEVILLE | Concrete Slab (4 spans) | -- | 1960 | -- | 44.0 | 154.9 | Fair | 82.3 | 000000012103810 |
NBI report | WILLEO ROAD | WILLEO CREEK | .01 MI N OF COBB CO LINE | Concrete Channel beam (4 spans) | -- | 1960 | -- | 29.9 | 120.1 | Fair | 62.8 | 000000012151580 |
NBI report | HOLCOMB BR ROAD | CHATTAHOOCHEE RIVER | FULTON-GWINNETT CO LINE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | 1982 | 104.0 | 297.9 | Fair | 52.5 | 000000012104720 |
NBI report | HOBGOOD ROAD | BEAR CREEK | 3 MI NE OF PALMETTO | Concrete Channel beam (2 spans) | -- | 1960 | 1985 | 29.9 | 60.0 | Good | 77.3 | 000000012150910 |
NBI report | OXBO ROAD | HOG WALLER CREEK | IN ROSWELL | Concrete Channel beam (2 spans) | -- | 1960 | 1988 | 29.9 | 60.0 | Fair | 67.5 | 000000012151340 |
NBI report | AZALEA DRIVE | CHATTAHOOCHEE RIV TRIB | 1.4 MI E OF COBB CO LINE | Concrete Channel beam | -- | 1960 | 2004 | 29.9 | 29.9 | Fair | 70.7 | 000000012151570 |
NBI report | GRIMES BRIDGE RD A | BIG CREEK | IN SOUTH ROSWELL | Concrete Slab (2 spans) | -- | 1960 | 2010 | 87.9 | 175.9 | Good | 98.1 | 000000012153540 |
NBI report | CEN OLYMPIC PARK D | M9161 MITCHELL-N SOU RR | IN ATLANTA | Steel Stringer/Multi-beam or girder (30 spans) | -- | 1961 | -- | 160.1 | 2241.3 | Fair | 66.1 | 000000012103590 |
NBI report | CSX RAIL ROAD | M-9064 NORMAN BERRY RD | INSIDE EAST POINT C.L. | Concrete Slab | -- | 1961 | -- | 40.0 | -- | -- | -- | 000000012105980 |
NBI report | CSX RAILROAD | SR 6 | IN COLLEGE PARK | Concrete Slab | -- | 1961 | -- | 42.0 | -- | -- | -- | 000000012105370 |
NBI report | JAMES JACKSON PWY | PROCTOR CREEK | IN N W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 40.0 | 120.1 | Fair | 67.3 | 000000012101140 |
NBI report | JAMES JACKSON PWY | SOUTHERN RAILROAD | IN N FULTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 68.9 | 168.0 | Fair | 78.7 | 000000012101150 |
NBI report | M.L.K. JR. DRIVE | NS RR-CS 3435 MANGUM | IN ATLANTA | Steel Stringer/Multi-beam or girder (20 spans) | -- | 1961 | -- | 205.1 | 2195.0 | Fair | 66.3 | 000000012103910 |
NBI report | NORFOLK SOUTHERN R | SR 237 PIEDMONT ROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1961 | -- | 43.0 | -- | -- | -- | 000000012105080 |
NBI report | OAKLEY ROAD | BROADANAX CREEK | CITY OF SOUTH FULTON | Concrete Channel beam | -- | 1961 | -- | 29.9 | 29.9 | Fair | 34.7 | 000000012150770 |
NBI report Bridgehunter | ROSWELL ROAD | I-285 | IN N FULTON | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1961 | -- | 74.2 | 242.1 | Good | 75.0 | 000000012100310 |
NBI report | ROSWELL ROAD US19 | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 44.9 | 130.9 | Fair | 72.5 | 000000012100300 |
NBI report | SHORT ROAD | PEA CREEK | 4 MI NW OF FAIRBURN | Concrete Channel beam (2 spans) | -- | 1961 | -- | 29.9 | 60.0 | Fair | 65.5 | 000000012150510 |
NBI report | TANACREST DRIVE | CHATTAHOOCHEE RIVER TRIB | 5.4 MI S OF ROSWELL | Concrete Culvert (2 spans) | -- | 1961 | -- | 9.8 | 21.0 | Good | 92.4 | 000000012150930 |
NBI report | WATERS ROAD | LONG INDIAN CREEK | 3 MI SE OF ALPHARETTA | Concrete Channel beam | -- | 1961 | -- | 29.9 | 29.9 | Fair | 61.7 | 000000012150240 |
NBI report | WOOD ROAD | CHICKEN CREEK | 4 MI NW OF ALPHARETTA | Concrete Channel beam (4 spans) | -- | 1961 | -- | 29.9 | 120.1 | Fair | 52.2 | 000000012150130 |
NBI report | US 29 | SR 14 SPUR | 3.5 MI NE OF UNION CITY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1961 | 1991 | 76.1 | 271.0 | Good | 65.2 | 000000012100430 |
NBI report | BIRMINGHAM ROAD | CHICKEN CREEK TRIB | 6 MI N OF ALPHARETTA | Concrete Channel beam | -- | 1961 | 1994 | 29.9 | 29.9 | Fair | 43.1 | 000000012150030 |
NBI report | I-285 | M-9219 P'TREE DUNWOODY R | IN N FULTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1996 | 102.0 | 210.0 | Good | 78.9 | 000000012102480 |
NBI report | ATLANTA NEWNAN RD. | CEDAR CREEK | 3 MI W OF PALMETTO | Concrete Channel beam (3 spans) | -- | 1962 | -- | 29.9 | 89.9 | Fair | 46.6 | 000000012150420 |
NBI report | BATESVILLE ROAD | CHICKEN CREEK | 5 MI NW OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1962 | -- | 29.9 | 60.0 | Fair | 63.5 | 000000012150110 |
NBI report | BRUMBELOW ROAD | CHATTAHOOCHEE RIVER TRIB | 5 MI SE OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1962 | -- | 29.9 | 60.0 | Good | 55.5 | 000000012150250 |
NBI report | DERRICK ROAD | DEEP CREEK TRIB | 3.5 MI N OF FAIRBURN | Prestressed Channel beam (2 spans) | -- | 1962 | -- | 29.9 | 60.0 | Fair | 62.6 | 000000012150640 |
NBI report | FORREST PARK RD | FEDERAL PRISON CREEK | IN SOUTH EAST ATLANTA | Concrete Slab | -- | 1962 | -- | 27.9 | 27.9 | Good | 94.0 | 000000012105780 |
NBI report | HEARDS ROAD | I-285 (SR 407) | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | -- | 73.2 | 248.0 | Fair | 63.3 | 000000012104770 |
NBI report | LEE STREET | I-20 | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | -- | 74.2 | 212.0 | Fair | 81.2 | 000000012103110 |
NBI report | McGINNIS FERRY ROA | CANEY CREEK | 5.7 MI E OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1962 | -- | 29.9 | 60.0 | Fair | 43.5 | 000000012102870 |
NBI report | MT. VERNON HWY | I-285 (SR 407) | IN N FULTON | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | -- | 94.2 | 291.0 | Fair | 71.8 | 000000012104440 |
NBI report | NEW PROVIDENCE ROA | COOPER SANDY CREEK | 5 MI NW OF ALPHARETTA | Concrete Channel beam (3 spans) | -- | 1962 | -- | 29.9 | 89.9 | Fair | 21.8 | 000000012150150 |
NBI report | OLD PHILLIPS ROAD | LONGINO CREEK | 5 MI NW OF PALMETTO | Concrete Channel beam | -- | 1962 | -- | 29.9 | 29.9 | Good | 54.8 | 000000012150500 |
NBI report | PROVIDENCE ROAD | COOPER SANDY CREEK | 3 MI NW OF ALPHARETTA | Prestressed Channel beam | -- | 1962 | -- | 29.9 | 29.9 | Fair | 51.4 | 000000012150160 |
NBI report | RIVERSIDE DRIVE | I-285 (SR 407) | IN N FULTON | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | -- | 73.2 | 257.9 | Fair | 74.7 | 000000012104520 |
NBI report | THOMPSON ROAD | CHICKEN CREEK TRIB | 4 MI N OF ALPHARETTA | Concrete Channel beam (3 spans) | -- | 1962 | -- | 29.9 | 89.9 | Fair | 54.3 | 000000012150090 |
NBI report | US 29 | SR 6 | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1962 | -- | 44.0 | 86.9 | Good | 73.1 | 000000012100440 |
NBI report | WESTSIDE ROAD | MILL BRANCH | 9 MI NW OF PALMETTO | Concrete Channel beam | -- | 1962 | -- | 29.9 | 29.9 | Fair | 74.4 | 000000012150490 |
NBI report | I-20 | JOSEPH E. LOWERY BLVD. | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | 1981 | 53.2 | 173.9 | Fair | 89.2 | 000000012101780 |
NBI report | I-20 | SR 14- M-9124- NS RR. | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 1981 | 168.0 | 362.9 | Fair | 75.0 | 000000012101790 |
NBI report | US 29, SR 14 MAIN | M-9064 NORMAN BERRY RD | IN EAST POINT | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1962 | 1985 | 43.0 | 86.0 | Good | 90.4 | 000000012100450 |
NBI report | I-20- AND 2 RAMPS | M-9160 WINDSOR STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | 1987 | 58.1 | 222.1 | Good | 67.5 | 000000012101810 |
NBI report | NORTHSIDE DR (SBL) | I-285 (SR 407) | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | 1987 | 89.9 | 288.1 | Fair | 61.6 | 000000012103270 |
NBI report | I-285 | M-9249 LONG ISLAND DRIVE | IN N FULTON COUNTY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 1995 | 55.1 | 126.0 | Fair | 72.0 | 000000012102440 |
NBI report | I-285 | CR 299 LAKE FOREST DRIVE | IN N FULTON COUNTY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 1995 | 47.9 | 120.1 | Fair | 81.1 | 000000012102450 |
NBI report | I-285 | M-9252 GLENRIDGE DRIVE | IN N FULTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 1995 | 50.9 | 124.0 | Fair | 77.1 | 000000012102460 |
NBI report | COFIELD DRIVE | I-85 | IN HAPEVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 63.0 | 223.1 | Fair | 81.0 | 000000012104710 |
NBI report | E. MAIN STREET | SR 6 CAMP CREEK PKWY. | IN SOUTH COLLEGE PARK | Concrete Slab (4 spans) | -- | 1963 | -- | 42.0 | 167.0 | Fair | 63.9 | 000000012103120 |
NBI report | FAIRBURN ROAD | I-20 | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 109.9 | 293.0 | Fair | 75.3 | 000000012103460 |
NBI report | I-85 | FLINT RIVER TRIB | IN COLLEGE PARK | Concrete Culvert (3 spans) | -- | 1963 | -- | 8.9 | 29.9 | Good | 70.0 | 000000012106710 |
NBI report | I-85 SPUR AIR. CON | I-85 | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 94.2 | 328.1 | Fair | 66.2 | 000000012102140 |
NBI report | JACKSON STREET | SR 10 | IN ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 74.2 | 221.1 | Fair | 76.1 | 000000012104290 |
NBI report | LANDRUM ROAD | TRICKHAM CREEK | 3 MI S OF FAIRBURN | Prestressed Channel beam (2 spans) | -- | 1963 | -- | 29.9 | 60.0 | Fair | 54.7 | 000000012150800 |
NBI report | MALLORY ROAD | CSX RAILROAD (638608X) | 2 MI NE OF UNION CITY | Concrete Channel beam (3 spans) | -- | 1963 | -- | 29.9 | 89.9 | Fair | 64.9 | 000000012150760 |
NBI report | NORFOLK SOUTHERN R | I-85 | IN HAPEVILLE | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 100.1 | -- | -- | -- | 000000012104860 |
NBI report | NORFOLK SOUTHERN R | SR 13 | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 43.0 | -- | -- | -- | 000000012104870 |
NBI report | NORFOLK SOUTHERN R | SR 154 LAKEWOOD F'WAY | IN NORTH EAST POINT | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 55.1 | -- | -- | -- | 000000012105050 |
NBI report | NORMAN BERRY DR | I-85 | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 87.9 | 237.9 | Fair | 86.4 | 000000012103530 |
NBI report | PED. OVERPASS | SR 166 LAKEWOOD F'WAY | IN NE EAST POINT | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 60.0 | -- | -- | -- | 000000012105060 |
NBI report | SCARBROUGH ROAD | WOLF CREEK | 3.5 MI N OF UNION CITY | Concrete Channel beam (2 spans) | -- | 1963 | -- | 29.9 | 60.0 | Fair | 57.9 | 000000012150680 |
NBI report | SYLVAN ROAD | I-85 | IN HAPEVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 84.0 | 226.1 | Fair | 92.8 | 000000012103730 |
NBI report | VIRGINIA AVE. | I-85 | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 85.0 | 256.9 | Fair | 51.6 | 000000012103800 |
NBI report | WHITEHALL STREET | M-9073 SPRING STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 63.0 | 214.9 | Fair | 76.5 | 000000012100090 |
NBI report | WILLINGHAM DRIVE | I-85 | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 109.9 | 316.9 | Fair | 68.9 | 000000012103720 |
NBI report | I-20 | CSX RAILROAD | IN W FULTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1979 | 49.9 | 149.0 | Good | 92.1 | 000000012101640 |
NBI report | I-20 | SR 70 FULTON IND. BLVD. | IN W FULTON | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | 1979 | 75.1 | 240.2 | Fair | 62.7 | 000000012101650 |
NBI report | I-20 | SR 139 M.L.K. JR. DRIVE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1979 | 71.9 | 159.1 | Fair | 80.0 | 000000012101660 |
NBI report | I-20 | CS 1575 LUCILE AVE. | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1981 | 150.9 | 287.1 | Good | 82.0 | 000000012101770 |
NBI report | SR 13 | CLEAR CREEK | IN N ATLANTA | Concrete Tee beam (3 spans) | -- | 1963 | 1983 | 86.0 | 211.0 | Good | 93.7 | 000000012102060 |
NBI report | I-85 | M-9082 CLEVELAND AVE. | IN S ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1984 | 81.0 | 151.9 | Good | 90.9 | 000000012101980 |
NBI report | I-20 | SR 3- NOR SOUTHERN RR | IN ATLANTA | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1963 | 1986 | 100.1 | 893.1 | Fair | 54.9 | 000000012101800 |
NBI report | I-85 | SR 3 METROPOLITAIN AVE. | IN S ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1986 | 78.1 | 146.0 | Fair | 93.9 | 000000012102000 |
NBI report | LAKEWOOD F'WAY | M-9081 SYLVAN ROAD | IN EAST POINT | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1963 | 1987 | 44.0 | 173.9 | Fair | 81.0 | 000000012101010 |
NBI report | I-85 RAMP NBL | SOUTH RIVER | IN SOUTH ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1988 | 53.2 | 154.9 | Fair | 95.7 | 000000012102020 |
NBI report | BATESVILLE ROAD | LITTLE RIVER | 6 MI NW OF ALPHARETTA | Concrete Channel beam (4 spans) | -- | 1964 | -- | 29.9 | 120.1 | Fair | 60.9 | 000000012150120 |
NBI report | BUFFINGTON ROAD | I-85 | 2 M E OF UNION CITY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 82.0 | 301.9 | Fair | 75.5 | 000000012103640 |
NBI report | BUICE ROAD | JOHNS CREEK | 6 MI SE OF ALPHARETTA | Concrete Channel beam (4 spans) | -- | 1964 | -- | 29.9 | 120.1 | Good | 57.7 | 000000012150260 |
NBI report | CENTRAL AVE. | I-85 | IN HAPEVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 99.1 | 315.0 | Fair | 73.9 | 000000012103700 |
NBI report | FORREST PARK RD | I-285 (SR 407) | SOUTH ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 74.2 | 255.9 | Fair | 84.0 | 000000012103780 |
NBI report | GARRETTS FERRY RD | CHATTAHOOCHEE RIV TRIB | 9 MI NW OF PALMETTO | Concrete Channel beam | Closed | 1964 | -- | 29.9 | 29.9 | Poor | 26.4 | 000000012150460 |
NBI report | HAMBY ROAD | CHICKEN CREEK | 6 MI N OF ALPHARETTA | Concrete Slab (2 spans) | -- | 1964 | -- | 29.9 | 60.0 | Fair | 61.2 | 000000012150040 |
NBI report | I-285 | POOLE CREEK TRIB | 3 MI E OF HAPEVILLE | Concrete Culvert (3 spans) | -- | 1964 | -- | 8.9 | 29.9 | Fair | 70.0 | 000000012102490 |
NBI report | I-285 | SANDY CREEK | IN W ATLANTA | Concrete Culvert (3 spans) | -- | 1964 | -- | 6.9 | 24.0 | Good | 70.0 | 000000012107270 |
NBI report | I-85 | BRANCH MORNING CREEK | 1.5 MI E OF UNION CITY | Concrete Culvert (2 spans) | -- | 1964 | -- | 9.8 | 21.0 | Good | 75.7 | 000000012101960 |
NBI report | I-85 | MORNING CREEK TRIB | 1.8 MI NE OF UNION CITY | Concrete Culvert (2 spans) | -- | 1964 | -- | 14.1 | 29.9 | Good | 70.0 | 000000012101970 |
NBI report | JONESBORO ROAD | I-285 | IN SOUTH ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 87.9 | 301.9 | Fair | 83.6 | 000000012100520 |
NBI report | LAWTON STREET | CSX RAILROAD (340346P) | IN ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | -- | 36.1 | 107.0 | Fair | 66.5 | 000000012103870 |
NBI report | LAWTON STREET | M-9131 WHITE STREET | IN ATLANTA | Concrete Slab (2 spans) | -- | 1964 | -- | 56.1 | 92.9 | Fair | 63.5 | 000000012103880 |
NBI report | LINKWOOD ROAD | I-20 | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 91.9 | 267.1 | Fair | 82.3 | 000000012103360 |
NBI report | LONGSTREET ROAD | CHICKEN CREEK TRIB | 7 MI N OF ALPHARETTA | Concrete Channel beam (3 spans) | -- | 1964 | -- | 29.9 | 89.9 | Fair | 62.8 | 000000012150060 |
NBI report | M.L.K. JR. DRIVE | I-285 | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 82.0 | 233.9 | Fair | 49.3 | 000000012100830 |
NBI report | PIEDMONT AVE. | CLEAR CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | -- | 49.9 | 149.9 | Fair | 64.5 | 000000012100370 |
NBI report | SARDIS CHURCH ROAD | DRY BRANCH | 6 MI W OF PALMETTO | Prestressed Channel beam (2 spans) | -- | 1964 | -- | 29.9 | 60.0 | Good | 77.2 | 000000012150430 |
NBI report | SR 154 | SOUTH UTOY CREEK | IN NW EAST POINT | Concrete Culvert (3 spans) | -- | 1964 | -- | 7.9 | 26.9 | Good | 73.4 | 000000012100960 |
NBI report | STACKS ROAD | CSX RAILROAD (638609E) | 2.6 MI NE OF UNION CITY | Concrete Channel beam (3 spans) | -- | 1964 | -- | 29.9 | 89.9 | Fair | 63.5 | 000000012152100 |
NBI report | STANTON ROAD | SOUTH UTOY CREEK | IN NORTH EAST POINT | Concrete Culvert (3 spans) | -- | 1964 | -- | 8.9 | 28.9 | Good | 91.5 | 000000012103580 |
NBI report | WILKERSON MILL RD. | LITTLE BEAR CREEK | 3 MI NW OF PALMETTO | Concrete Channel beam (2 spans) | -- | 1964 | -- | 29.9 | 60.0 | Good | 65.5 | 000000012150600 |
NBI report | FLAT SHOALS ROAD | I-85 | 2.5 M E OF UNION CITY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | 1980 | 77.1 | 288.1 | Fair | 85.2 | 000000012102760 |
NBI report | I-20 | CS 961 FAIRFIELD PLACE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1981 | 74.2 | 137.1 | Good | 91.2 | 000000012101720 |
NBI report | I-20 | M-9135 ANDERSON ROAD | IN W ATLNTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1981 | 69.9 | 149.9 | Fair | 88.7 | 000000012101730 |
NBI report | I-20 | MLK DR & WEST LAKE AVE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1964 | 1981 | 75.1 | 450.2 | Fair | 87.5 | 000000012101740 |
NBI report | I-20 | M-9130 LAWTON STREET | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1981 | 82.0 | 163.1 | Good | 84.0 | 000000012101760 |
NBI report | I-285 CBL | M-9045 COLLIER DRIVE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1982 | 56.1 | 134.8 | Fair | 67.6 | 000000012102380 |
NBI report | I-285 CCBL | M-9045 COLLIER DRIVE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1982 | 53.2 | 113.9 | Fair | 67.6 | 000000012102390 |
NBI report | I-75 | NANCY CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1983 | 100.1 | 259.9 | Good | 84.0 | 000000012101530 |
NBI report | I-75 | SR 3 NORTHSIDE PARKWAY | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1983 | 152.9 | 299.9 | Fair | 72.5 | 000000012101550 |
NBI report | I-75 | M-9241 MT. PARAN ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1983 | 61.0 | 141.1 | Good | 73.2 | 000000012101570 |
NBI report | I-75 | SOUTH RIVER TRIB | IN S ATLANTA | Concrete Culvert (3 spans) | -- | 1964 | 1986 | 8.9 | 41.0 | Good | 70.0 | 000000012101340 |
NBI report | I-75 | SOUTH RIVER TRIB. | IN SOUTH ATLANTA | Concrete Culvert (3 spans) | -- | 1964 | 1986 | 7.9 | 26.9 | Fair | 59.0 | 000000012101350 |
NBI report | BANKHEAD HIGHWAY U | I-285 | IN NW ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | 1987 | 69.9 | 213.9 | Fair | 78.6 | 000000012100190 |
NBI report | HIGH POINT ROAD | DEEP CREEK | IN NW CORNER UNION CITY | Prestressed Channel beam (3 spans) | -- | 1964 | 1998 | 29.9 | 89.9 | Fair | 71.5 | 000000012150710 |
NBI report | I-75 | CHATTAHOOCHEE RIVER | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (17 spans) | -- | 1964 | 1998 | 60.0 | 1020.1 | Good | 66.9 | 000000012101590 |
NBI report | ALDREDGE ROAD | WOLF CREEK | 7 MI N OF FAIRBURN | Concrete Channel beam (2 spans) | -- | 1965 | -- | 29.9 | 60.0 | Fair | 68.6 | 000000012150580 |
NBI report | BETHSAIDA ROAD | MORNING CREEK | 4 MI W OF UNION CITY | Prestressed Channel beam (4 spans) | -- | 1965 | -- | 29.9 | 120.1 | Fair | 62.7 | 000000012102950 |
NBI report | BOHANNON ROAD | I-85 | 2 MILES SW OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 75.1 | 279.9 | Good | 95.9 | 000000012102630 |
NBI report | CAMP CREEK PKWY | CAMP CREEK | IN COLLEGE PARK C.L. | Concrete Culvert (4 spans) | -- | 1965 | -- | 13.1 | 56.1 | Fair | 79.4 | 000000012104650 |
NBI report | CHILDRESS DRIVE | SR 154 | IN SW ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 76.1 | 234.9 | Good | 61.1 | 000000012103490 |
NBI report | CSX RAILROAD | I-85 | 1.9 M SE OF FAIRBURN | Steel Stringer/Multi-beam or girder | -- | 1965 | -- | 73.2 | -- | -- | -- | 000000012104850 |
NBI report | DINSMORE ROAD | CHICKEN CREEK | 6 MI N OF ALPHARETTA | Concrete Channel beam (2 spans) | -- | 1965 | -- | 29.9 | 60.0 | Fair | 82.1 | 000000012150100 |
NBI report | DODSON DRIVE | SR 154 LAKEWOOD F'WAY | IN SW ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 57.1 | 182.1 | Good | 88.1 | 000000012103180 |
NBI report | FAIR DRIVE | SOUTH RIVER TRIB | IN ATLANTA | Concrete Culvert (2 spans) | -- | 1965 | -- | 14.1 | 28.9 | Good | 84.7 | 000000012100160 |
NBI report | FAIR DRIVE | SOUTH RIVER TRIB | IN ATLANTA | Concrete Culvert (3 spans) | -- | 1965 | -- | 18.0 | 58.1 | Good | 84.1 | 000000012100180 |
NBI report | FAYETTEVILLE RD | I-85 | 1.7 M SE OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 96.1 | 345.2 | Fair | 77.7 | 000000012102690 |
NBI report | GILEAD ROAD | SR 154 | IN S W ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 56.1 | 179.1 | Fair | 77.7 | 000000012103520 |
NBI report | I-285 | NORTH FORK CAMP CREEK | IN S W ATLANTA | Concrete Culvert (3 spans) | -- | 1965 | -- | 9.8 | 32.2 | Fair | 59.0 | 000000012102260 |
NBI report | MAXWELL DRIVE | SR 154 | IN SW ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 60.0 | 205.1 | Fair | 83.5 | 000000012103130 |
NBI report | PED OVERPASS | SR 154 LAKEWOOD F'WAY | IN EAST POINT | Steel Stringer/Multi-beam or girder | -- | 1965 | -- | 80.1 | -- | -- | -- | 000000012105040 |
NBI report | ROSWELL ROAD | MARSH CREEK | 5.2 MI S OF ROSWELL | Concrete Culvert (4 spans) | -- | 1965 | -- | 9.8 | 44.0 | Good | 72.8 | 000000012100320 |
NBI report | RUSSELL DRIVE | ROCKY CREEK | 7 MI W OF ALPHARETTA | Concrete Channel beam (5 spans) | -- | 1965 | -- | 29.9 | 149.9 | Fair | 83.0 | 000000012151000 |
NBI report | SPENCE ROAD | I-85 | 1.3 S OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 70.9 | 268.1 | Fair | 63.8 | 000000012100710 |
NBI report | SR 154 / SR 166 NB | M-9071 DELOWE DRIVE | IN NORTH EAST POINT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 65.0 | 164.1 | Good | 76.8 | 000000012100970 |
NBI report | SR 154 NBL | M-9072 STANTON ROAD | IN NORTH EAST POINT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 64.0 | 178.2 | Fair | 75.8 | 000000012100990 |
NBI report | SR 154 SBL | M-9071 DELOWE DRIVE | IN NORTH EAST POINT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 65.0 | 164.1 | Fair | 76.8 | 000000012100980 |
NBI report | SR 154 SBL | M-9072 STANTON ROAD | IN NORTH EAST POINT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 64.0 | 175.9 | Fair | 76.8 | 000000012101000 |
NBI report | WESTVIEW DRIVE | I-20 | IN W ATLANTA | Steel Girder and floorbeam system (3 spans) | -- | 1965 | -- | 201.1 | 674.9 | Fair | 92.6 | 000000012103890 |
NBI report | WESTVIEW DRIVE | M-9131- WHITE STREET | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1965 | -- | 60.0 | 317.9 | Poor | 62.5 | 000000012103900 |
NBI report | I-20 | I-285- I-285 RAMP | IN W ATLANTA | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1965 | 1979 | 97.1 | 557.1 | Fair | 79.2 | 000000012101670 |
NBI report | I-20 | SR 280 H.E.HOLMES DRIVE | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1981 | 128.0 | 212.0 | Fair | 79.2 | 000000012101700 |
NBI report | I-20 | CSX RAILROAD- MARTA | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1981 | 121.1 | 303.2 | Good | 70.7 | 000000012101710 |
NBI report | I-20 | M-9131 LANGHORN STREET | IN W ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1965 | 1981 | 68.9 | 296.9 | Fair | 73.2 | 000000012101750 |
NBI report | RMP I-20W-I-285CCB | I-285 CBL | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1982 | 126.0 | 258.9 | Fair | 68.0 | 000000012101880 |
NBI report | RMP I-285 CBL-I-20 | I-285 CCBL (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1982 | 84.0 | 186.0 | Fair | 77.3 | 000000012102550 |
NBI report | LAKEWOOD F'WAY | SR 3 METROPOLITAIN BLVD | .25 MI W OF I-75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1986 | 82.0 | 158.1 | Fair | 83.9 | 000000012101030 |
NBI report | SR 74 WBL | I-85 | 1.5 M S OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | 1987 | 76.1 | 277.9 | Fair | 76.2 | 000000012100690 |
NBI report | ALISON STREET | SOUTH UTOY CREEK TRIB | IN SOUTHWEST ATLANTA | Concrete Culvert (3 spans) | -- | 1966 | -- | 9.8 | 32.2 | Good | 92.1 | 000000012151560 |
NBI report | BAKER ROAD | PROCTOR CREEK TRIB | IN ATLANTA | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 21.0 | Good | 92.1 | 000000012151800 |
NBI report | BENJAMIN MAYS DR. | I-285 (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 69.9 | 235.9 | Good | 74.6 | 000000012103390 |
NBI report | BURDETTE ROAD | MORNING CREEK TRIB | 4 MI E OF UNION CITY | Concrete Channel beam | -- | 1966 | -- | 32.2 | 32.2 | Good | 76.7 | 000000012150730 |
NBI report | CS 7001 | CAMP CREEK | INSIDE COLLEGE PARK C L. | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 59.1 | 59.1 | Fair | 54.9 | 000000012151980 |
NBI report | CUMMING STREET | BIG CREEK TRIBUTARY | IN ALPHARETTA CITY LIMITS | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 21.0 | Good | 92.2 | 000000012105910 |
NBI report | GREAT SOUTHWEST PY | NORTH UTOY CREEK | 10.5 MI W OF ATLANTA | Concrete Channel beam (5 spans) | -- | 1966 | -- | 29.9 | 149.9 | Fair | 82.7 | 000000012151030 |
NBI report | GULLATT ROAD | I-85 | 3.5 MI SW OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 79.1 | 294.0 | Fair | 85.9 | 000000012102660 |
NBI report | HAMBY ROAD | CHICKEN CREEK TRIB | 6 MI N OF ALPHARETTA | Concrete Channel beam | -- | 1966 | -- | 29.9 | 29.9 | Fair | 50.9 | 000000012150050 |
NBI report | I-285 | BRANCH OF S UTOY CREEK | IN WEST ATLANTA | Concrete Culvert (3 spans) | -- | 1966 | -- | 9.8 | 33.1 | Good | 70.0 | 000000012102310 |
NBI report | JOHNSON ROAD | I-85 | 4 MI SW OF FAIRBURN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 108.9 | 390.1 | Fair | 85.9 | 000000012102650 |
NBI report | KINGSPORT DRIVE | LONG ISLAND CREEK | JUST W OF I-285-SR 9 INT. | Concrete Channel beam (3 spans) | -- | 1966 | -- | 29.9 | 89.9 | Fair | 75.6 | 000000012151870 |
NBI report | MARTA | SR 154 LAKEWOOD F'WAY | 3.3 MI S OF JCT I-20 | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 55.1 | -- | -- | -- | 000000012105410 |
NBI report | NOR SOU RR (718035 | M-9189 NORTH AVE. | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 40.0 | -- | -- | -- | 000000012105290 |
NBI report | NOR SOU RR SPUR | M-9189 NORTH AVE. | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 38.1 | -- | -- | -- | 000000012105300 |
NBI report | PRYOR ROAD | SR 166 | IN SOUTH ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 58.1 | 183.1 | Fair | 66.5 | 000000012104220 |
NBI report | REDWINE ROAD | I-285 (SR 407) | IN EAST POINT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 88.9 | 318.9 | Fair | 81.1 | 000000012103150 |
NBI report | SR 154 EBL | I-285 | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 82.0 | 230.0 | Fair | 70.1 | 000000012100940 |
NBI report | SR 154 SB RAMP TO | SR 154 RAMP | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 60.0 | 191.9 | Fair | 87.5 | 000000012101050 |
NBI report | SR 154 SB RAMP TO | I-285 (SR 407) | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 82.0 | 235.9 | Fair | 83.5 | 000000012101060 |
NBI report | SR 154 WBL | I-285 | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 82.0 | 230.0 | Fair | 71.1 | 000000012100950 |
NBI report | STANFORD DRIVE | PROCTOR CREEK | IN N W ATLANTA | Concrete Culvert (3 spans) | -- | 1966 | -- | 12.1 | 38.1 | Good | 92.4 | 000000012151790 |
NBI report | STONE HOGAN CONN | NORTH FORK CAMP CREEK | IN ATLANTA | Concrete Culvert (3 spans) | -- | 1966 | -- | 13.1 | 41.0 | Good | 76.0 | 000000012105750 |
NBI report | UTILITY BRIDGE | I-285 | IN SOUTHWEST ATLANTA | Steel Girder and floorbeam system | -- | 1966 | -- | 8.2 | -- | -- | -- | 000000012104890 |
NBI report | I-285 | NORTH UTOY CREEK | IN W ATLANTA | Concrete Tee beam (5 spans) | -- | 1966 | 1978 | 34.1 | 167.0 | Fair | 85.9 | 000000012102360 |
NBI report | JONESBORO ROAD | I-85 | 1.5 M SE OF UNION CITY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | 1978 | 82.0 | 308.1 | Fair | 62.7 | 000000012100800 |
NBI report | I-20 EBL | RMP I-20W TO I-285 CCBL | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1979 | 77.1 | 191.9 | Fair | 87.1 | 000000012101680 |
NBI report | I-285 | SOUTH FORK CAMP CREEK | IN EAST POINT | Concrete Tee beam (5 spans) | -- | 1966 | 1981 | 27.9 | 140.1 | Fair | 66.4 | 000000012102230 |
NBI report | I-285 | M-9056 N CAMP CREEK PKY | IN S W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1981 | 66.9 | 130.9 | Good | 74.0 | 000000012102240 |
NBI report | I-285 | SOUTH UTOY CREEK | IN WEST ATLANTA | Concrete Tee beam (5 spans) | -- | 1966 | 1982 | 32.2 | 160.1 | Poor | 56.9 | 000000012102320 |
NBI report | RMP I-285 CCBL-I-2 | I-285 CBL (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1982 | 88.9 | 209.0 | Good | 90.6 | 000000012102530 |
NBI report | RMP I-285 CCBL-I-2 | RMP I-20W TO I-285 CCBL | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1982 | 59.1 | 170.0 | Fair | 77.8 | 000000012102540 |
NBI report | I-285 | SR 14 (US 29)- CSX RR | 2 M S W OF COLLEGE PARK | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1966 | 1984 | 74.2 | 301.9 | Fair | 67.2 | 000000012102220 |
NBI report | CAMP CREEK P'WAY | I-285 (SR 407) | IN EAST POINT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | 1988 | 69.9 | 236.9 | Fair | 92.1 | 000000012104660 |
NBI report | BOULDER PARK RD | I-285 (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 88.9 | 253.0 | Fair | 70.3 | 000000012103370 |
NBI report | CSX RAILROAD | I-285 (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1967 | -- | 92.9 | -- | -- | -- | 000000012104900 |
NBI report | KOWETA ROAD | DEEP CREEK | 3 MI N OF FAIRBURN | Prestressed Channel beam (3 spans) | -- | 1967 | -- | 29.9 | 89.9 | Fair | 47.0 | 000000012150630 |
NBI report | MARIETTA BLVD. NW | CSX RAILROAD SPUR | IN WEST ATLANTA | Concrete Slab (3 spans) | -- | 1967 | -- | 29.9 | 78.1 | Good | 77.7 | 000000012152280 |
NBI report | OLD NATIONAL HWY. | SR 14- CSX RAILROAD | IN SOUTH COLLEGE PARK | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1967 | -- | 57.1 | 373.0 | Fair | 59.8 | 000000012101130 |
NBI report | PETER ROAD | BROADANAX CREEK | CITY OF UNION CITY | Concrete Channel beam (2 spans) | -- | 1967 | -- | 29.9 | 60.0 | Fair | 46.2 | 000000012150780 |
NBI report | WASHINGTON ROAD | I-285 (SR 407) | IN EAST POINT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 112.9 | 303.2 | Fair | 50.8 | 000000012103660 |
NBI report | I-285 | CS 2766 DELMAR LANE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1978 | 47.9 | 116.1 | Fair | 63.5 | 000000012102370 |
NBI report | I-285 | M-9059 GREENBRIAR ROAD | IN S W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1982 | 66.9 | 133.9 | Fair | 72.7 | 000000012102270 |
NBI report | I-285 | M-9058 MT GILEAD ROAD | IN SOUTHWEST ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1982 | 68.9 | 159.1 | Fair | 87.2 | 000000012102290 |
NBI report | I-285 | M-9053 CASCADE ROAD | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1982 | 66.9 | 138.1 | Fair | 73.8 | 000000012102340 |
NBI report | BIRMINGHAM ROAD | LITTLE RIVER | FULTON-CHEROKEE CO LINE | Concrete Channel beam (3 spans) | -- | 1968 | -- | 29.9 | 89.9 | Fair | 43.5 | 000000012151510 |
NBI report | BOLTON ROAD | I-285- PROCTOR CREEK | IN W ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1968 | -- | 134.8 | 513.1 | Fair | 61.1 | 000000012100670 |
NBI report | GLENRIDGE ROAD | MARSH CREEK | 6 MI S OF ROSWELL | Concrete Channel beam (2 spans) | -- | 1968 | -- | 29.9 | 60.0 | Fair | 80.2 | 000000012150350 |
NBI report | HOWELL MILL ROAD | NS RAILROAD (717955M) | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1968 | -- | 63.0 | 119.1 | Fair | 76.9 | 000000012104000 |
NBI report | I-285 CB OFF RAMP | PROCTOR CREEK | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 86.0 | 232.0 | Fair | 86.5 | 000000012102560 |
NBI report | JONES ROAD | WILLEO CREEK | @ WEST ROSWELL CTY LIMIT | Concrete Channel beam (3 spans) | -- | 1968 | -- | 29.9 | 89.9 | Fair | 58.0 | 000000012152630 |
NBI report | MOUNT VERNON HWY | SR 400 (US 19) | 1.4 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 96.1 | 289.1 | Fair | 92.7 | 000000012104450 |
NBI report | NORTHWEST ROAD | PROCTOR CREEK | IN N W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 45.9 | 137.1 | Fair | 88.1 | 000000012103350 |
NBI report | PHIPPS ROAD | CSX RAILROAD (50399M) | AT PALMETTO CITY LIMITS | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 71.9 | 185.0 | Fair | 97.9 | 000000012151880 |
NBI report | PITTS ROAD | SR 400 (US 19) | 4.3 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 69.9 | 235.9 | Fair | 65.3 | 000000012104760 |
NBI report | RIVERSIDE ROAD | CHATTAHOOCHEE RIVER TRIB | 3 MI SE OF ROSWELL | Concrete Channel beam (3 spans) | -- | 1968 | -- | 29.9 | 89.9 | Good | 82.5 | 000000012150280 |
NBI report | RIVERSIDE ROAD | CHATTAHOOCHEE RIVER TRIB | 4 MI SE OF ROSWELL | Concrete Channel beam | -- | 1968 | -- | 29.9 | 29.9 | Good | 81.7 | 000000012150290 |
NBI report | SPALDING DRIVE | SR 400 (US 19) | 3.2 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 104.0 | 356.0 | Fair | 52.2 | 000000012104550 |
NBI report | US 19 SBL, SR 400 | RMP I285 CBL TO SR400 N | JCT I-285 & SR 400 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 82.0 | 231.0 | Fair | 79.1 | 000000012101190 |
NBI report | I-285 | PROCTOR CREEK | IN W ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1968 | 1982 | 64.0 | 319.9 | Fair | 78.0 | 000000012102400 |
NBI report | I-285 | CR 1971- CHATT RIV.- RR | IN W ATLANTA | Steel Stringer/Multi-beam or girder (12 spans) | -- | 1968 | 1982 | 109.9 | 847.2 | Fair | 74.2 | 000000012102420 |
NBI report | US 19 | M-9250 ABERNATHY ROAD | 5.9 MI S OF ROSWELL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 1985 | 88.9 | 157.2 | Fair | 68.2 | 000000012101210 |
NBI report | I-285R CCB TO SR40 | SR 400 NBL (US 19) | IN N FULTON | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 83.0 | 317.9 | Fair | 92.6 | 000000012102570 |
NBI report | KIMBALL BRIDGE RD. | SR 400 (US 19) | IN EAST ALPHARETTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 99.1 | 324.2 | Fair | 69.3 | 000000012104750 |
NBI report | PLEASANT HILL ROAD | CATER CREEK | 5 MI E OF FAIRBURN | Prestressed Channel beam (2 spans) | -- | 1969 | -- | 29.9 | 60.0 | Good | 82.7 | 000000012150720 |
NBI report | ROBERTS DRIVE | SR 400 (US 19) | 2.1 MI SW OF ROSWELL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 95.1 | 293.0 | Fair | 82.7 | 000000012103160 |
NBI report | SR 70 NBL | UTOY CREEK | 2.7 MI S OF I-20 | Concrete Tee beam (3 spans) | -- | 1969 | -- | 35.1 | 104.0 | Fair | 90.8 | 000000012100640 |
NBI report | US 19 / SR. 400 | BIG CREEK TRIBUTARY | IN EAST ALPHARETTA | Concrete Culvert (2 spans) | -- | 1969 | -- | 11.2 | 23.0 | Fair | 70.0 | 000000012102350 |
NBI report | US 19 SBL, SR 400 | I-285 (SR 407) | JCT I-285 & SR 400 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 98.1 | 305.1 | Good | 85.0 | 000000012101200 |
NBI report | WEBB BRIDGE ROAD | SR 400 (US 19) | .85 MI N OF SR 120 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 95.1 | 297.9 | Fair | 62.8 | 000000012102990 |
NBI report | JOHNSON FERRY RD | CHATTAHOOCHEE RIVER | 2 MI W OF JCT US 19 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1969 | 1981 | 56.1 | 392.1 | Fair | 65.2 | 000000012104570 |
NBI report | US 19 | CR 139 ROBERTS DRIVE | 3.6 MI S OF ROSWELL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | 1985 | 54.1 | 134.8 | Fair | 61.2 | 000000012101230 |
NBI report | HOLCOMB BR ROAD | SR 400 (US 19) | 8.1 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | 1987 | 90.9 | 301.9 | Fair | 90.1 | 000000012100860 |
NBI report | US 19 / SR 400 | BIG CREEK | 9.1 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | 1990 | 45.9 | 183.1 | Fair | 88.4 | 000000012101270 |
NBI report | HAYNES BRIDGE RD | SR 400 (US 19) | 11.3 MI N OF I-285 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | 1994 | 87.9 | 295.9 | Fair | 66.2 | 000000012103030 |
NBI report | I-285 | SR 400 NBL (US 19) | IN N FULTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | 1995 | 101.1 | 223.1 | Good | 72.9 | 000000012102470 |
NBI report | OLD MILTON PARKWAY | SR 400 (US 19) | IN NE ALPHARETTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | 1995 | 97.1 | 304.1 | Fair | 67.6 | 000000012100750 |
NBI report | COCHRAN MILL ROAD | LITTLE BEAR CREEK | 5 MI NW OF PALMETTO | Concrete Channel beam (3 spans) | -- | 1970 | -- | 29.9 | 89.9 | Fair | 81.4 | 000000012151120 |
NBI report | COCHRAN MILL ROAD | BEAR CREEK | 5 MI NW OF PALMETTO | Concrete Channel beam (3 spans) | -- | 1970 | -- | 29.9 | 89.9 | Fair | 78.4 | 000000012151130 |
NBI report | DELOWE DRIVE | SOUTH UTOY CREEK TRIB | IN EAST POINT | Concrete Culvert (3 spans) | -- | 1970 | -- | 9.8 | 33.1 | Good | 74.8 | 000000012103570 |
NBI report | CAMP CREEK PKWY. | NORTH FORK CAMP CREEK | 4.1 MI W OF COLLEGE PARK | Concrete Culvert (4 spans) | -- | 1970 | 1985 | 14.1 | 61.0 | Good | 73.0 | 000000012104680 |
NBI report | US 19, SR 400 | M9408 RIV'SIDE DR- CHATT | 1.8 MI E OF ROSWELL | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1970 | 1987 | 141.1 | 679.2 | Fair | 73.2 | 000000012101250 |
NBI report | CAPPS FERRY ROAD | CHATTAHOOCHEE RIVER | FULTON-DOUGLAS CO LINE | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1971 | -- | 82.0 | 410.1 | Fair | 71.7 | 000000012152380 |
NBI report | CASCADE ROAD | CSX RAILROAD | 7.4 MI W OF ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 69.9 | 191.9 | Fair | 73.5 | 000000012100900 |
NBI report | KIMBERLY MILL ROAD | KIMBERLY CREEK | 3 MI E OF UNION CITY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 38.1 | 109.9 | Fair | 88.9 | 000000012151020 |
NBI report | MARIETTA ROAD | CSX RR YARD (TILFORD) | IN N W ATLANTA | Prestressed Box beam or girders - Multiple (5 spans) | -- | 1971 | -- | 95.1 | 422.9 | Poor | 17.1 | 000000012151490 |
NBI report | OAKLEY IND BLVD. | BROADANAX CREEK | 3 MI SE OF FAIRBURN | Concrete Culvert (2 spans) | -- | 1971 | -- | 12.1 | 24.9 | Good | 91.7 | 000000012151170 |
NBI report | BEECHER STREET | UTOY CREEK | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1972 | -- | 56.1 | 56.1 | Fair | 79.8 | 000000012103860 |
NBI report | MARIETTA BLVD. | SEWAGE CHNL & SERVICE RD | IN N ATLANTA | Concrete Culvert (2 spans) | -- | 1972 | -- | 16.1 | 32.2 | Fair | 74.4 | 000000012106810 |
NBI report | PACES FERRY ROAD | CHATTAHOOCHEE RIVER | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1972 | -- | 64.0 | 383.9 | Fair | 64.6 | 000000012103280 |
NBI report | RICO ROAD | LONGINO CREEK | 5 MI NW OF PALMETTO | Concrete Channel beam (2 spans) | -- | 1972 | -- | 29.9 | 60.0 | Fair | 70.3 | 000000012151110 |
NBI report | FLAT SHOALS ROAD | MORNING CREEK TRIB | 1.7 MI E OF UNION CITY | Concrete Channel beam (2 spans) | -- | 1972 | 1979 | 29.9 | 60.0 | Good | 56.0 | 000000012102750 |
NBI report | SR 9 | FOE KILLER CREEK | IN THE CITY OF ROSWELL | Concrete Culvert (4 spans) | -- | 1973 | 1988 | 12.1 | 49.9 | Good | 79.9 | 000000012100350 |
NBI report | MARIETTA STREET | CSX RAILROAD- SOU. RR. | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1974 | -- | 190.0 | 190.0 | Fair | 72.8 | 000000012100040 |
NBI report | McGINNIS FERRY RD | SR 400 (US 19) | APP .5 MI W JCT FAS 2349 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 94.2 | 304.1 | Fair | 79.6 | 000000012102850 |
NBI report | NOR SOU RAILROAD | M9315 INTERNATIONAL BLVD | IN ATLANTA | Concrete Arch - Deck | -- | 1974 | -- | 3.6 | -- | -- | -- | 000000012105360 |
NBI report | NORTHSIDE DR (NBL) | M-9150 THIRD STREET | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 73.2 | 222.1 | Fair | 95.7 | 000000012100110 |
NBI report | SERVICE RD PARKING | M-9315 INTERNATIONAL BLD | IN ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 56.1 | 191.9 | Fair | 83.1 | 000000012104730 |
NBI report | WEATHER TUNNEL | PARKING DECK ACCESS ROAD | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1974 | -- | 78.1 | -- | -- | -- | 000000012153780 |
NBI report | WELCOME ALL ROAD | CSX RAILROAD | 3.8 MI N OF UNION CITY | Concrete Tee beam (3 spans) | -- | 1974 | -- | 49.9 | 144.0 | Fair | 88.0 | 000000012103610 |
NBI report | DRIVE ACCESS OMNI | M-9315 INT.BLVD & RR | IN ATLANTA | Steel Stringer/Multi-beam or girder (40 spans) | -- | 1974 | 1993 | 133.9 | 3715.1 | Fair | 92.7 | 000000012104740 |
NBI report | ALPINE DRIVE | HOG WALLER CREEK | IN ROSWELL CITY LIMITS | Concrete Culvert (2 spans) | -- | 1975 | -- | 12.1 | 24.9 | Good | 99.6 | 000000012152490 |
NBI report | PED. BRIDGE | M-9007 JUNIPER STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1975 | -- | 77.1 | -- | -- | -- | 000000012106820 |
NBI report | ROXBURGH DRIVE | BIG CREEKTRIBUTARY | 3 MI S OF ALPHARETTA | Concrete Culvert (2 spans) | -- | 1975 | -- | 12.1 | 24.9 | Fair | 99.3 | 000000012150990 |
NBI report | US 19 / SR 400 | CAMP CREEK | IN NORTH ALPHARETTA | Concrete Culvert (2 spans) | -- | 1975 | -- | 11.2 | 22.0 | Fair | 70.0 | 000000012101310 |
NBI report | CAMP CRK PKWY NBL | I-85- 2 I-85 RAMPS | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1976 | -- | 154.9 | 282.2 | Good | 78.6 | 000000012104630 |
NBI report | CAMP CRK PKWY SBL | I-85- 2 I-85 RAMPS | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1976 | -- | 150.9 | 276.9 | Good | 71.0 | 000000012104640 |
NBI report | HAMMOND DRIVE | NANCY CREEK TRIB | .4 MI W OF DEKALB CO LINE | Concrete Culvert (2 spans) | -- | 1976 | -- | 9.8 | 21.0 | Good | 80.8 | 000000012105930 |
NBI report | INTERNATIONAL DRIV | FLINT RIVER | IN ATLANTA | Concrete Culvert (3 spans) | -- | 1976 | -- | 8.9 | 28.9 | Good | 78.4 | 000000012103820 |
NBI report | P'TREE-DUNWOODY RD | NANCY CREEK TRIB | .3 MI W OF DEKALB CO LINE | Concrete Culvert (3 spans) | -- | 1976 | -- | 9.8 | 32.2 | Good | 80.4 | 000000012105920 |
NBI report | PED. OVERPASS | M-9003 DECATUR STREET | IN CITY OF ATLANTA | Concrete Slab | -- | 1976 | -- | 49.9 | -- | -- | -- | 000000012105700 |
NBI report | PED. OVERPASS | M-9003 DECATUR STREET | IN CITY OF ATLANTA | Concrete Slab | -- | 1976 | -- | 49.9 | -- | -- | -- | 000000012105710 |
NBI report | PED. OVERPASS | M-9003 DECATUR STREET | IN CITY OF ATLANTA | Concrete Slab | -- | 1976 | -- | 49.9 | -- | -- | -- | 000000012105720 |
NBI report | WELCOME ALL ROAD | CAMP CREEK | IN SOUTH WEST ATLANTA | Concrete Tee beam (4 spans) | -- | 1976 | -- | 34.1 | 136.2 | Good | 72.4 | 000000012103620 |
NBI report | ABBOTTS BRIDGE RD. | JOHNS CREEK | 6.2 MI E OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 1977 | -- | 8.9 | 29.9 | Fair | 98.2 | 000000012100780 |
NBI report | CHAPPELL ROAD | MARTA | IN WEST ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1977 | -- | 48.9 | 87.9 | Good | 95.5 | 000000012103950 |
NBI report | CRABAPPLE ROAD | HOGWALLER CREEK | IN NW ROSWELL-OLD SR 140 | Concrete Culvert (3 spans) | -- | 1977 | -- | 6.9 | 23.0 | Good | 96.7 | 000000012103100 |
NBI report | CSX RAILROAD | M-9007 PIEDMONT AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 80.1 | -- | -- | -- | 000000012105130 |
NBI report | CSX RAILROAD | SR 6 CAMP CREEK PKWY. | 4.2 MI W OF COLLEGE PARK | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 65.0 | -- | -- | -- | 000000012105380 |
NBI report | CSX RAILROAD | CS 2051 JESSE HILL JR DR | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 65.9 | -- | -- | -- | 000000012151640 |
NBI report | JONES FERRY ROAD | WHITE OAK CREEK | 7 MI NW OF PALMETTO | Concrete Culvert (4 spans) | -- | 1977 | -- | 8.9 | 40.0 | Good | 100.0 | 000000012150480 |
NBI report | MARTA | CS 2051 JESSE HILL JR DR | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 76.1 | -- | -- | -- | 000000012151650 |
NBI report | PED OVERPASS | M9315 INTERNATIONAL BLVD | IN CITY OF ATLANTA | Steel Girder and floorbeam system | -- | 1977 | -- | 99.1 | -- | -- | -- | 000000012105840 |
NBI report | SR 13 | PEACHTREE CREEK | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 68.9 | 205.1 | Good | 95.8 | 000000012105430 |
NBI report | WELCOME ALL ROAD | SR 6 CAMP CREEK PKWY. | 4.2 MI W OF COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1977 | -- | 54.1 | 107.9 | Good | 96.4 | 000000012103630 |
NBI report | LENOX ROAD | NORTH FORK P'TREE CREEK | IN N W ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1977 | 1981 | 76.1 | 151.9 | Fair | 87.4 | 000000012100400 |
NBI report | CAMP CREEK PKWY. | CAMP CREEK TRIB | 5.6 MILES WEST OF COLLEGE | Concrete Culvert (3 spans) | -- | 1977 | 1984 | 12.1 | 38.1 | Fair | 83.0 | 000000012104690 |
NBI report | BOLTON ROAD | NS RR (718026P) | IN N W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 99.1 | 221.1 | Fair | 91.9 | 000000012100680 |
NBI report | CENTRAL AVE. | M-9064 NORMAN BERRY DR | IN EAST POINT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 67.9 | 128.0 | Fair | 79.1 | 000000012103710 |
NBI report | DE FOORS FERRY RD. | PEACHTREE CREEK TRIB | IN N ATLANTA | Concrete Culvert (3 spans) | -- | 1978 | -- | 9.8 | 32.2 | Good | 98.0 | 000000012104380 |
NBI report | HOLCOMB BRIDGE ROA | BIG CREEK | IN ROSWELL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 84.0 | 232.0 | Fair | 66.5 | 000000012100850 |
NBI report | I-285 CCB RMP-SR13 | CS 2766 DELMAR LANE | IN W ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 47.9 | 118.1 | Good | 83.3 | 000000012102520 |
NBI report | I-85 | AIRPORT LIGHTS | IN EAST POINT | Steel Truss - Deck | -- | 1978 | -- | 115.2 | -- | -- | -- | 000000012152760 |
NBI report | MARIETTA ROAD | NS RR YARD (INMAN) | IN N W ATLANTA | Steel Box beam or girders - Multiple (4 spans) | -- | 1978 | -- | 192.9 | 618.1 | Fair | 97.7 | 000000012151500 |
NBI report | MARTA | M-9007 PIEDMONT AVE. | IN CITY OF ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1978 | -- | 89.9 | -- | -- | -- | 000000012105120 |
NBI report | MARTA | FORSYTH STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1978 | -- | 160.1 | -- | -- | -- | 000000012105940 |
NBI report | MARTA | M-9124-WHITEHALL-FULTON | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1978 | -- | 245.1 | -- | -- | -- | 000000012105950 |
NBI report | MARTA | CS 961 FAIRFIELD PLACE | IN W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1978 | -- | 96.1 | -- | -- | -- | 000000012151820 |
NBI report | MARTA | CS 1923 SUNSET AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1978 | -- | 6.9 | -- | -- | -- | 000000012151890 |
NBI report | MARTA | CS 2798 WESTLAND BLVD. | IN ATLANTA | Steel Box Beam or girders - Single or Spread | -- | 1978 | -- | 9.5 | -- | -- | -- | 000000012151940 |
NBI report | I-85 | FLINT RIVER TRIB | IN COLLEGE PARK | Concrete Culvert (3 spans) | -- | 1979 | -- | 8.9 | 29.9 | Good | 70.0 | 000000012105960 |
NBI report | LOOP RD(AIRPORT) | I-85- I-85 RAMP NB | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1979 | -- | 120.1 | 414.1 | Good | 91.6 | 000000012103830 |
NBI report | LOOP RD(AIRPORT) | I-85- I-85 RAMP | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1979 | -- | 191.0 | 328.1 | Good | 77.0 | 000000012103840 |
NBI report | NOR SOU RR (718012 | M-9064 NORMAN BERRY RD | IN EAST POINT | Steel Stringer/Multi-beam or girder | -- | 1979 | -- | 66.9 | -- | -- | -- | 000000012105180 |
NBI report | RMP I-20 TO SR 139 | I-285 (SR 407) | IN W ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1979 | -- | 179.1 | 550.9 | Fair | 91.8 | 000000012101890 |
NBI report | SR 120 WBL | BIG CREEK | IN ALPHARETTA | Prestressed Box beam or girders - Multiple (5 spans) | -- | 1979 | -- | 38.1 | 190.0 | Fair | 86.1 | 000000012100770 |
NBI report | W. P'TREE- MARTA | I-75 | CIVIC CENTER STATION | Steel Girder and floorbeam system (2 spans) | -- | 1979 | -- | 129.9 | 259.9 | Fair | 73.9 | 000000012104140 |
NBI report | FORSYTH STREET | CSX RR & PARKING LOT | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1979 | 1996 | 87.9 | 469.2 | Good | 78.2 | 000000012152700 |
NBI report | PED OVERPASS | CS 1790 DEKALB AVE. | IN ATLANTA | Steel Girder and floorbeam system | -- | 1980 | -- | 137.1 | -- | -- | -- | 000000012151860 |
NBI report | SPRING STREET | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1980 | -- | 219.2 | 219.2 | Good | 80.6 | 000000012103600 |
NBI report | SR 9 | HOG WALLOW CREEK | IN THE CITY OF ROSWELL | Concrete Culvert (4 spans) | -- | 1980 | -- | 8.9 | 40.0 | Fair | 83.2 | 000000012100340 |
NBI report | BOHANNON ROAD | SR 74 | IN FAIRBURN | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1981 | -- | 75.1 | 153.9 | Good | 89.4 | 000000012102640 |
NBI report | CSX RAILROAD | SR 74 SENOIA ROAD | IN CITY OF FAIRBURN | Steel Stringer/Multi-beam or girder | -- | 1981 | -- | 75.1 | -- | -- | -- | 000000012105400 |
NBI report | US 29 / SR. 14 | SR 74 | IN THE CITY OF FAIRBURN | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1981 | -- | 75.1 | 146.0 | Good | 79.2 | 000000012100410 |
NBI report | MARTA BRIDGE | I-20 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1982 | -- | 166.0 | -- | -- | -- | 000000012105420 |
NBI report | RICHARD RUSSELL | PARKING LOT NS RR | IN ATLANTA | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1982 | -- | 83.0 | 418.0 | Fair | 96.9 | 000000012151720 |
NBI report | WOODRUFF ROAD | LITTLE PEA CREEK TRIB | 6 MI NW OF PALMETTO | Concrete Channel beam | -- | 1982 | -- | 29.9 | 29.9 | Good | 77.4 | 000000012150380 |
NBI report | ALEXANDER STREET | M-9073 TECHWOOD-SPRG C | IN NW ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 83.0 | 83.0 | Good | 92.0 | 000000012105630 |
NBI report | BOATROCK ROAD | SR- 6 CAMP CREEK PKWY. | 9.9 MI N OF UNION CITY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1983 | -- | 76.1 | 253.9 | Fair | 99.5 | 000000012105730 |
NBI report | CAMP CREEK PKWY | CAMP CREEK TRIB | 6.1 MI W OF COLLEGE PARK | Concrete Culvert (3 spans) | -- | 1983 | -- | 12.1 | 38.1 | Good | 78.3 | 000000012105850 |
NBI report | CAMP CREEK PKWY | CAMP CREEK TRIB | 6.2 MI W OF COLLEGE PARK | Concrete Culvert (2 spans) | -- | 1983 | -- | 9.8 | 21.0 | Good | 80.0 | 000000012105860 |
NBI report | CAMP CREEK PKWY | CAMP CREEK TRIB | 9.3 MI N OF UNION CITY | Concrete Culvert (3 spans) | -- | 1983 | -- | 9.8 | 33.1 | Good | 79.5 | 000000012105870 |
NBI report | CSX RAILROAD | SR 280 HIGHTOWER ROAD | IN W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 94.2 | -- | -- | -- | 000000012105090 |
NBI report | CSX RAILROAD | CS 1170 DILL AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 78.1 | -- | -- | -- | 000000012152040 |
NBI report | CSX RAILROAD | CS 1191 ASTOR AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 78.1 | -- | -- | -- | 000000012152050 |
NBI report | HIGHLAND AVE. | ATLANTA BELTLINE | IN ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 81.0 | 180.1 | Good | 97.2 | 000000012104280 |
NBI report | HOWELL MILL ROAD | CSX RAILROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 120.1 | 120.1 | Fair | 77.8 | 000000012104010 |
NBI report | I-75 HOV RAMPS | I-75 SBL | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1983 | -- | 205.1 | 455.1 | Good | 97.0 | 000000012105440 |
NBI report | I-75 RAMP | M-9073 SPRING STREET | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 84.0 | 84.0 | Good | 97.3 | 000000012105480 |
NBI report | I-85R N TO I-285CB | SR 14 (US 29)- CSX RR. | I-285 & I-85 INTERCHANGE | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1983 | -- | 71.9 | 242.1 | Good | 85.1 | 000000012106110 |
NBI report | IN ATLANTA | I-75 | RM FR WILLIAMS ST TO I75 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1983 | -- | 244.1 | 628.0 | Good | 96.8 | 000000012104310 |
NBI report | LENOX ROAD | NS RR- MARTA | IN BUCKHEAD | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1983 | -- | 60.0 | 258.9 | Good | 80.9 | 000000012104460 |
NBI report | MARTA | I-85 | IN N ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1983 | -- | 87.9 | -- | -- | -- | 000000012106090 |
NBI report | MARTA | CS 2353 SYLVAN ROAD | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1983 | -- | 97.1 | -- | -- | -- | 000000012152070 |
NBI report | MARTA BRIDGE | SR 14 LEE STREET | IN WEST ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1983 | -- | 74.2 | -- | -- | -- | 000000012105670 |
NBI report | MARTA BRIDGE | M-9219 ROXBORO ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 73.2 | -- | -- | -- | 000000012105830 |
NBI report | MURPHY AVE. | CS 1191 ASTOR AVE. | IN EAST POINT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 78.1 | 144.0 | Fair | 97.7 | 000000012152060 |
NBI report | NORTH AVENUE | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 147.0 | 253.0 | Fair | 84.3 | 000000012100220 |
NBI report | SPRING STREET | I-75 | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1983 | -- | 216.9 | 417.0 | Good | 93.6 | 000000012100250 |
NBI report | TENTH STREET | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 107.0 | 212.9 | Good | 92.9 | 000000012104070 |
NBI report | US 29 / SR. 14 | SR 166 | IN NORTH EAST POINT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 113.9 | 274.0 | Fair | 92.3 | 000000012100460 |
NBI report | WILLIAMS STREET | M-9073 TECHWOOD-SPRG C | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 107.9 | 107.9 | Good | 94.7 | 000000012105660 |
NBI report | CAMP CRK PKWY EBL | CHATT. RIVER - RAILROAD | DOUGLS CO. LINE | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1984 | -- | 107.9 | 855.0 | Fair | 97.8 | 000000012105890 |
NBI report | CAMP CRK PKWY WBL | CHATT. RIVER - RAILROAD | DOUGLAS CO. LINE | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1984 | -- | 107.9 | 855.0 | Good | 97.8 | 000000012105880 |
NBI report | CENTRAL AVE. US 19 | I-75- 2 I-75 RAMPS | .4 MI N CLAYTON CO LINE | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1984 | -- | 83.0 | 387.2 | Fair | 92.2 | 000000012100010 |
NBI report | CLEVELAND AVE. | I-75- I-75 RAMP | 1 MI NE OF HAPEVILLE | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1984 | -- | 101.1 | 335.0 | Good | 81.7 | 000000012103740 |
NBI report | COLES WAY | CHATTAHOOCHEE RIVER TRIB | 6 MI S OF ALPHARETTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 40.0 | 120.1 | Good | 69.5 | 000000012152170 |
NBI report | CSX RAILROAD | SR 139 M.L.K. JR. DRIVE | IN W ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 78.1 | -- | -- | -- | 000000012105030 |
NBI report | CSX RAILROAD | SR 138 | 1 MI NE OF FAIRBURN | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 92.9 | -- | -- | -- | 000000012105450 |
NBI report | DEERING ROAD | I-75 + I-85 RAMP | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 131.9 | 291.0 | Fair | 77.9 | 000000012104050 |
NBI report | GARSON DRIVE | MARTA | IN BUCKHEAD | Prestressed Stringer/Multi-beam or girder | -- | 1984 | -- | 86.0 | 86.0 | Good | 78.8 | 000000012152030 |
NBI report | HORTENSE WAY | PROCTOR CREEK | IN WEST ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 124.0 | 124.0 | Good | 89.4 | 000000012150950 |
NBI report | I-285 R TO I-85 | SR 14- CSX RAILROAD | 2 MI SW OF COLLEGE PARK | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1984 | -- | 71.9 | 312.0 | Good | 92.9 | 000000012105650 |
NBI report | I-285 RAMP | I-85 RMP TO AIRPORT OR C | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1984 | -- | 187.0 | 187.0 | Good | 96.4 | 000000012105640 |
NBI report | I-285 RMP TO I-85 | SR 14 SPUR | 4.5 MI NE OF UNION CITY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 120.1 | 200.1 | Good | 98.7 | 000000012105600 |
NBI report | I-75 | SOUTH RIVER | 1.5 M NE OF HAPEVILLE | Concrete Culvert (4 spans) | -- | 1984 | -- | 9.8 | 43.0 | Good | 70.0 | 000000012101330 |
NBI report | I-75 | TANYARD BRANCH | IN ATLANTA | Concrete Culvert (4 spans) | -- | 1984 | -- | 9.8 | 45.9 | Good | 71.4 | 000000012101470 |
NBI report | I-75 | M-9094 MT ZION ROAD | IN HAPEVILLE | Prestressed Stringer/Multi-beam or girder | -- | 1984 | -- | 79.1 | 79.1 | Good | 85.0 | 000000012105490 |
NBI report | I-85 | CLEAR CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 92.9 | 256.9 | Good | 85.0 | 000000012105500 |
NBI report | I-85 | SR 13 | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 51.8 | 104.0 | Good | 85.2 | 000000012105560 |
NBI report | I-85 | RAMP SR13 SBL TO 403 SBL | IN N ATLANTA | Prestressed Slab | -- | 1984 | -- | 45.9 | 45.9 | Good | 84.8 | 000000012105620 |
NBI report | I-85 | NS RAILROAD | IN N ATLANTA | Concrete Frame | -- | 1984 | -- | 34.1 | 34.1 | Good | 85.0 | 000000012105900 |
NBI report | I-85 | NS RAILROAD | IN N ATLANTA | Concrete Frame | -- | 1984 | -- | 34.1 | 34.1 | Good | 85.0 | 000000012106700 |
NBI report | I-85 NBL | I-75 N&S H.O.V. | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1984 | -- | 88.9 | 306.1 | Good | 75.2 | 000000012105470 |
NBI report | I-85 NBL | PEACHTREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 110.9 | 272.0 | Good | 79.1 | 000000012105530 |
NBI report | I-85 NBL | SR 236 LINDBERGH DRIVE | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 118.1 | 198.2 | Good | 81.3 | 000000012105550 |
NBI report | I-85 RAMP | SR 13 | IN N ATLANTA | Steel Box beam or girders - Multiple (4 spans) | -- | 1984 | -- | 128.9 | 350.1 | Fair | 96.0 | 000000012105570 |
NBI report | I-85 RAMP NBL | I-85 SB RAMP TO I-285 NB | 2 MI S W OF COLLAGE PARK | Prestressed Stringer/Multi-beam or girder | -- | 1984 | -- | 115.2 | 115.2 | Good | 96.4 | 000000012106190 |
NBI report | I-85 RMP FROM SR13 | PEACHTREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1984 | -- | 78.1 | 360.9 | Good | 70.6 | 000000012105590 |
NBI report | I-85 RMP SB TO SR1 | I-85&RMP- SR13- SR236&RM | IN N ATLANTA | Prestressed Box Beam or girders - Single or Spread (7 spans) | -- | 1984 | -- | 272.0 | 1629.0 | Good | 96.3 | 000000012105580 |
NBI report | I-85 SBL | SR 236 LINDBERGH DRIVE | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 113.9 | 191.0 | Good | 84.9 | 000000012105540 |
NBI report | JONES BRIDGE ROAD | LINE CREEK | 4 MI NW OF FAIRBURN | Prestressed Channel beam | -- | 1984 | -- | 29.9 | 29.9 | Fair | 75.2 | 000000012150610 |
NBI report | LINDBERGH ROAD | MARTA | IN BUCKHEAD | Prestressed Stringer/Multi-beam or girder | -- | 1984 | -- | 59.1 | 86.0 | Good | 96.5 | 000000012106060 |
NBI report | LOOP ROAD | FLINT RIVER | ATLANTA AIRPORT | Concrete Culvert (3 spans) | -- | 1984 | -- | 7.9 | 26.9 | Good | 82.2 | 000000012105790 |
NBI report | MARTA | SR 237 PIEDMONT ROAD | IN NORTH ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 5.9 | -- | -- | -- | 000000012105680 |
NBI report | MARTA | SR 280 HIGHTOWER ROAD | IN W ATLANTA | Steel Box beam or girders - Multiple | -- | 1984 | -- | 9.5 | -- | -- | -- | 000000012105690 |
NBI report | MARTA | SR 13 | IN N ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1984 | -- | 43.0 | -- | -- | -- | 000000012106040 |
NBI report | MOORES MILL ROAD | I-75 | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 149.9 | 285.1 | Fair | 61.2 | 000000012103260 |
NBI report | NORFOLK SOUTHERN R | I-75 | IN HAPEVILLE | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 83.0 | -- | -- | -- | 000000012104790 |
NBI report | PED. OVERPASS | M-9180 BOULEVARD | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1984 | -- | 9.2 | -- | -- | -- | 000000012106280 |
NBI report | PORSHE AVENUE | I-75, NBCD, SBCD | 1 M E OF HAPEVILLE | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1984 | -- | 83.0 | 387.2 | Fair | 96.7 | 000000012105610 |
NBI report | RMP I-85 N TO I-28 | I-85- I-85 RAMP | 2 MI SW OF COLLEGE PARK | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1984 | -- | 129.9 | 502.0 | Fair | 94.7 | 000000012102150 |
NBI report | RMP I-85 N TO I-28 | SR 14 SPUR | I-285 & I-85 ON SW SIDE | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1984 | -- | 110.9 | 359.9 | Fair | 89.3 | 000000012102170 |
NBI report | SR 13 | PEACHTREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 109.9 | 256.9 | Good | 89.9 | 000000012102100 |
NBI report | SR 138 | CSX RR& CR 611 GOODSON R | IN SOUTH UNION CITY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1984 | -- | 74.2 | 245.1 | Good | 81.4 | 000000012105460 |
NBI report | SR13 R TO P'TREE S | SR 13 | IN N ATLANTA | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1984 | -- | 121.1 | 441.0 | Good | 98.7 | 000000012106030 |
NBI report Bridgehunter | I-85 | SR237-RMP-2SR13RMPS-2 CS | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (40 spans) | -- | 1984 | 1993 | 119.1 | 4151.1 | Fair | 78.0 | 000000012105510 |
NBI report | I-85 SBL | PEACHTREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | 1993 | 109.9 | 272.0 | Fair | 74.5 | 000000012105520 |
NBI report | I-85 | M-9213- PEACHTREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (14 spans) | -- | 1984 | 2014 | 118.1 | 1176.9 | Fair | 73.6 | 000000012102130 |
NBI report | CASCADE ROAD | SOUTH UTOY CREEK | 6.8 MI W OF ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 40.0 | 80.1 | Good | 90.8 | 000000012100910 |
NBI report | CREEL ROAD | LITTLE PEA CREEK | 7 MI NW OF PALMETTO | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1985 | -- | 29.9 | 60.0 | Fair | 81.3 | 000000012150520 |
NBI report | HAROLD SHEAT PKY. | SR 14-M-9116-MARTA-CSX R | IN EAST POINT CITY LIMITS | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1985 | -- | 92.9 | 368.1 | Good | 85.0 | 000000012106210 |
NBI report | I-285 CCBL | I-85 RAMP NBL | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 188.0 | 188.0 | Good | 93.1 | 000000012102510 |
NBI report | I-285 RAMP TO I-85 | I-85 | I-285 & I-85 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1985 | -- | 158.1 | 275.9 | Good | 97.5 | 000000012106160 |
NBI report | I-285 RAMP TO I-85 | SR 14P- I-85R- SR 14R | I-285 & I-85 INTERSECTION | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1985 | -- | 141.1 | 548.9 | Good | 97.4 | 000000012106170 |
NBI report | I-285R CB TO I-85 | I-85- 2 I-85 RAMPS | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (5 spans) | -- | 1985 | -- | 128.9 | 530.9 | Fair | 94.5 | 000000012106200 |
NBI report | I-285R TO I-85 SBL | SR 14 SPUR- SR 14 RAMP | 4.6 MI NE OF UNION CITY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1985 | -- | 118.1 | 362.9 | Good | 76.2 | 000000012106180 |
NBI report | I-75 | CSX RAILROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1985 | -- | 55.1 | 189.0 | Good | 74.2 | 000000012101480 |
NBI report | I-75 | M-9209 WEST WESLEY ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 48.9 | 128.9 | Good | 73.9 | 000000012101510 |
NBI report | I-75 | M-9208 W.PACES FERRY RD. | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 94.2 | 94.2 | Good | 84.0 | 000000012101520 |
NBI report | I-85 | I-75 NBL- RAMP TO I85 NB | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 98.1 | 169.0 | Good | 81.0 | 000000012106080 |
NBI report | I-85 R TO I-285 EB | I-85-I-285-3 I-85R-I285R | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (9 spans) | -- | 1985 | -- | 206.0 | 1556.2 | Fair | 97.4 | 000000012106120 |
NBI report | I-85R SB TO 14 ST. | I-75 SBL | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 224.1 | 224.1 | Good | 98.0 | 000000012106130 |
NBI report | JONES ROAD | DEEP CREEK | 5 MI NORTH OF FAIRBURN | Concrete Tee beam (3 spans) | -- | 1985 | -- | 29.9 | 89.9 | Good | 97.7 | 000000012150620 |
NBI report | NOR SOU RR SPAN 4 | I-85 RMP SB TO I-75 NB | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 81.0 | -- | -- | -- | 000000012106140 |
NBI report | NOR SOUTHERN RR | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 145.0 | -- | -- | -- | 000000012104830 |
NBI report | NORFOLK SOUTHERN R | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 129.9 | -- | -- | -- | 000000012104820 |
NBI report | NORFOLK SOUTHERN R | I-85 RMP SB TO I-75 NB | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 100.1 | -- | -- | -- | 000000012106150 |
NBI report | OLD NATIONAL HWY. | I-85- I-285- 2 I-85 RMPS | IN COLLEGE PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 192.9 | 384.9 | Good | 91.6 | 000000012101120 |
NBI report | P'TREE BATTLE AVE | SR 401 (I-75) | IN N FULTON | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 94.2 | 188.0 | Good | 75.5 | 000000012104410 |
NBI report | PEACHTREE STREET U | I-85- SR 13 + RAILROAD | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 187.0 | 373.0 | Fair | 86.5 | 000000012100260 |
NBI report | PED. BRIDGE | SR 14 (US 29) | JUST E OF FORT McPHERSON | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 100.1 | -- | -- | -- | 000000012106730 |
NBI report | PED. BRIDGE | M-9073 SPRING STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1985 | -- | 73.2 | -- | -- | -- | 000000012106850 |
NBI report | SR 13 | CS 551 EQUIFAX DRIVE | IN N ATLANTA | Concrete Frame (2 spans) | -- | 1985 | -- | 16.1 | 32.2 | Good | 89.0 | 000000012106010 |
NBI report | SR 13 (NBL) | SR 9 (SBL) SPRING STREET | IN N ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 175.9 | 442.9 | Good | 95.7 | 000000012106020 |
NBI report | WEBB BRIDGE ROAD | BIG CREEK | 2.5 MI E OF ALPHARETTA | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1985 | -- | 29.9 | 89.9 | Fair | 59.5 | 000000012103000 |
NBI report | COGBURN ROAD | CHICKEN CREEK TRIB | 4 MI N OF ALPHARETTA | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 29.9 | 29.9 | Good | 60.9 | 000000012152020 |
NBI report | CSX RR-MARTA | M-9095 VIRGINIA AVE. | INSIDE COLLEGE PARK C.L. | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 76.1 | -- | -- | -- | 000000012105990 |
NBI report | E. MAIN STREET | M-9095 VIRGINIA AVE. | INSIDE COLLEGE PARK C.L. | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 76.1 | 76.1 | Fair | 83.6 | 000000012106000 |
NBI report | FAIR DRIVE | I-75 | IN SOUTH ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 138.1 | 274.9 | Good | 67.1 | 000000012100170 |
NBI report | FINLEY ROAD | JOHNS CREEK | 6 MI E OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 1986 | -- | 9.8 | 32.2 | Good | 99.4 | 000000012152090 |
NBI report | FLAT SHOALS ROAD | MORNING CREEK | 3.5 MI E OF UNION CITY | Concrete Culvert (3 spans) | -- | 1986 | -- | 9.8 | 32.2 | Good | 80.4 | 000000012102770 |
NBI report | FLAT SHOALS ROAD | MORNING CREEK TRIB | 4 MI E OF UNION CITY | Concrete Culvert (3 spans) | -- | 1986 | -- | 9.8 | 32.2 | Good | 80.1 | 000000012103690 |
NBI report | HOWELL MILL ROAD | I-75 + I-75 RAMP | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 96.1 | 225.1 | Good | 93.0 | 000000012104020 |
NBI report | I-75 | SR 54 UNIVERSITY AVENUE | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 120.1 | 223.1 | Good | 85.5 | 000000012101370 |
NBI report | I-85 | SOUTH RIVER | IN S ATLANTA | Concrete Culvert (4 spans) | -- | 1986 | -- | 9.8 | 48.9 | Good | 93.7 | 000000012106330 |
NBI report | I-85 RAMP TO I-285 | I-85 RAMP NBL TO SR 279 | I-285 & I-85 ON S SIDE | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 128.0 | 128.0 | Good | 85.5 | 000000012106100 |
NBI report | I-85 SBL | RAMP FR. RD. TO I-75 SBL | IN S ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 126.0 | 126.0 | Good | 92.6 | 000000012102050 |
NBI report | IRENE KIDD PARKWAY | MARTA | EAST POINT CITY LIMITS | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 60.0 | 60.0 | Good | 95.8 | 000000012151830 |
NBI report | IRENE KIDD PARKWAY | CSX RAILROAD | IN EAST POINT CITY LIMITS | Concrete Frame | -- | 1986 | -- | 32.2 | 32.2 | Good | 97.8 | 000000012151840 |
NBI report | IRENE KIDD PARKWAY | CEN OF GA RAILROAD | IN EAST POINT CITY LIMITS | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 95.1 | 95.1 | Good | 95.8 | 000000012151850 |
NBI report | MARTA | CR 519 ARMOUR DRIVE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 60.0 | -- | -- | -- | 000000012152110 |
NBI report | MARTA | CS 1170 DILL AVE. | IN CITY OF ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 78.1 | -- | -- | -- | 000000012152120 |
NBI report | MARTA | CS 1170 DILL AVE. | IN CITY OF ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 78.1 | -- | -- | -- | 000000012152130 |
NBI report | MARTA | CS 1191 ASTOR AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 78.1 | -- | -- | -- | 000000012152140 |
NBI report | MARTA | CS 1191 ASTOR AVE. | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 78.1 | -- | -- | -- | 000000012152150 |
NBI report | MARTA | CR 519 ARMOUR DRIVE | IN ATLANTA | Steel Box Beam or girders - Single or Spread | -- | 1986 | -- | 60.0 | -- | -- | -- | 000000012153690 |
NBI report | NEW N'SIDE DR (NBL | I-285 (SR 407) | IN N FULTON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 132.9 | 300.9 | Good | 72.2 | 000000012106250 |
NBI report | NORTHSIDE DRIVE | I-75 (SBL) + I-75 RAMP | IN NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 94.2 | 185.0 | Good | 95.8 | 000000012100120 |
NBI report | NORTHSIDE DRIVE | I-75 (NBL) | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 131.9 | 131.9 | Good | 94.8 | 000000012106050 |
NBI report | PRYOR STREET | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 233.0 | 431.1 | Good | 94.1 | 000000012100560 |
NBI report | SR 166 (5 X-REF.) | I-75- 3 SR166 RMP- I-85R | SR 166 & I-75 | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1986 | -- | 107.9 | 569.9 | Fair | 74.3 | 000000012101040 |
NBI report | US 29/ SR 14 | M-9095 VIRGINIA AVE. | INSIDE COLLEGE PARK C.L. | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 75.1 | 75.1 | Good | 74.8 | 000000012105970 |
NBI report | UTILITY BRIDGE | I-75- I-75 RAMP | IN NORTH ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 195.9 | -- | -- | -- | 000000012106070 |
NBI report | WINDWARD PKY (EBL) | BIG CREEK | IN ALPHARETTA CTY LIMITS | Prestressed Box beam or girders - Multiple (4 spans) | -- | 1986 | -- | 37.1 | 148.0 | Fair | 95.4 | 000000012106290 |
NBI report | WINDWARD PKY (WBL) | BIG CREEK | IN ALPHARETTA CTY LIMITS | Prestressed Box beam or girders - Multiple (4 spans) | -- | 1986 | -- | 37.1 | 148.0 | Good | 93.9 | 000000012106300 |
NBI report | WINDWARD PKY EBL | CAMP CREEK | 3 MI E OF ALPHARETTA | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1986 | -- | 32.2 | 64.0 | Good | 94.6 | 000000012106240 |
NBI report | WINDWARD PKY WBL | CAMP CREEK | 3 MI E OF ALPHARETTA | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1986 | -- | 33.1 | 65.9 | Good | 93.6 | 000000012102980 |
NBI report | BAKER STREET | I-75 + I-75 RAMP | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 187.0 | 391.1 | Good | 73.3 | 000000012106670 |
NBI report | COURTLAND STREET | I-75 | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1987 | -- | 169.0 | 337.9 | Good | 96.4 | 000000012106640 |
NBI report | CSX RAILROAD | CS 7134 LEE STREET | .5 MI NW OF ATL. AIRPORT | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 96.1 | -- | -- | -- | 000000012152160 |
NBI report | CSX RR (50347V) | M-9080 WILLINGHAM DRIVE | IN CITY OF ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1987 | -- | 75.1 | -- | -- | -- | 000000012105190 |
NBI report | I-20 RMP E TO I-75 | M-9163- M-9164- M-9166 | I-20 & I-75-85 INTER. | Prestressed Box Beam or girders - Single or Spread (6 spans) | -- | 1987 | -- | 146.0 | 708.0 | Good | 92.9 | 000000012106570 |
NBI report | I-285 CBL | SR 14 SPUR WBL | I-285 & I-85 SOUTH SIDE | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1987 | -- | 225.1 | 525.0 | Fair | 93.7 | 000000012106350 |
NBI report | I-285 CBL | I-85 SB RAMP TO I-285 NB | I-285 & I-85 SOUTH SIDE | Prestressed Stringer/Multi-beam or girder | -- | 1987 | -- | 103.0 | 103.0 | Good | 92.7 | 000000012106360 |
NBI report | I-285 CBL | I-85- 2 I-85 RAMPS | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1987 | -- | 185.0 | 616.2 | Fair | 85.0 | 000000012106370 |
NBI report | I-75 | M-9053 GEORGIA AVE. | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 120.1 | 191.9 | Good | 97.0 | 000000012106320 |
NBI report | I-85 NBL | I-75- 2 I-75 RAMPS | IN S ATLANTA | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1987 | -- | 240.2 | 726.1 | Fair | 98.0 | 000000012106340 |
NBI report | I-85R N TO SR14P W | I-85- I-85 RMP- I-285 R | 2 MI SW OF COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (6 spans) | -- | 1987 | -- | 180.1 | 731.0 | Good | 97.7 | 000000012106430 |
NBI report | I-85R N TO SR14P W | SR 14P & 2- I-285 RAMPS | 4.5 M NE OF UNION CITY | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1987 | -- | 107.9 | 796.0 | Fair | 85.8 | 000000012106500 |
NBI report | MARTA | M-9080 WILLINGHAM DRIVE | IN CITY OF ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1987 | -- | 73.2 | -- | -- | -- | 000000012106220 |
NBI report | NOR SOU RR (718059 | M-9086 PRYOR STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 106.0 | -- | -- | -- | 000000012105240 |
NBI report | NORFOLK SOUTHERN R | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 155.8 | -- | -- | -- | 000000012104800 |
NBI report | PEACHTREE STREET | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1987 | -- | 150.9 | 288.1 | Fair | 75.6 | 000000012106440 |
NBI report | PED. OVERPASS | M-9007 JUNIPER STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 87.9 | -- | -- | -- | 000000012106270 |
NBI report | RALPH MCGILL BLVD | I-75 RAMP TO COURTLAND | IN ATALNTA | Prestressed Stringer/Multi-beam or girder | -- | 1987 | -- | 86.9 | 86.9 | Good | 78.8 | 000000012106650 |
NBI report | RMP I-75N TO SR166 | I-75- SR 166 RAMP | IN S ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1987 | -- | 159.1 | 314.0 | Fair | 99.4 | 000000012106310 |
NBI report | SR 14 SPUR E Y-BR | I-85- I-85 RMP- I285 RMP | SW JCT I-85 & I-285 | Prestressed Box Beam or girders - Single or Spread (7 spans) | -- | 1987 | -- | 157.2 | 891.1 | Good | 94.0 | 000000012106480 |
NBI report | SR 166R EB TO I75N | I-75- SR 166 RAMP | IN S ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1987 | -- | 163.1 | 318.9 | Fair | 97.4 | 000000012106490 |
NBI report | SR 74 EBL | I-85 | 1.5 M S OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 78.1 | 280.9 | Good | 94.0 | 000000012106450 |
NBI report | US 41/ SR 3 RAMP T | M-9241 MT PARAN ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 80.1 | 148.0 | Good | 96.5 | 000000012106260 |
NBI report | WASHINGTON ROAD | FUR CREEK | IN EAST POINT | Concrete Culvert (3 spans) | -- | 1987 | -- | 9.8 | 32.2 | Fair | 81.5 | 000000012103670 |
NBI report | WASHINGTON ROAD | CAMP CREEK | IN EAST POINT | Concrete Tee beam (3 spans) | -- | 1987 | -- | 35.1 | 105.0 | Fair | 78.9 | 000000012103680 |
NBI report | PETERSBURG ROAD | BEAR CREEK | 3 MI N OF PALMETTO | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1987 | 1998 | 32.2 | 64.0 | Fair | 85.0 | 000000012150920 |
NBI report | BUICE ROAD | LONG INDIAN CREEK | 4.3 MI E OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 1988 | -- | 9.8 | 32.2 | Good | 99.9 | 000000012152570 |
NBI report | CAPITOL AVE. | I-20- I-75 RMP- I-20 RMP | I-20 & I-75 INTERCHANGE | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 195.9 | 542.0 | Good | 74.4 | 000000012106530 |
NBI report | CS02003 | PEACHTREE CENTER AVE | IN ATLANTA | Steel Truss - Thru | -- | 1988 | -- | 61.0 | -- | -- | -- | 000000012153770 |
NBI report | DECATUR STREET | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 186.0 | 355.0 | Fair | 93.0 | 000000012106660 |
NBI report | FULTON RM TO I-75 | I-75 NB RMP TO I-20 E&WB | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 85.0 | 85.0 | Good | 99.4 | 000000012107000 |
NBI report | FULTON STREET | I-75-3 I-75R-1 MRT-1 CS | IN ATLANTA | Prestressed Box beam or girders - Multiple (5 spans) | -- | 1988 | -- | 164.1 | 622.1 | Good | 94.9 | 000000012106540 |
NBI report | FULTON STREET | M-9164 CENTRAL AVE. | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 77.1 | 77.1 | Good | 92.1 | 000000012106600 |
NBI report | I-20 EBL | 3I75RMP-2I20RMP-3MRT-2MR | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (9 spans) | -- | 1988 | -- | 270.0 | 1785.2 | Good | 89.9 | 000000012106510 |
NBI report | I-20 RMP EB TO I-7 | I-75-3I-75R-I-20R-3MRT-2 | I-20 & I-75-85 INTERCHANG | Prestressed Box Beam or girders - Single or Spread (8 spans) | -- | 1988 | -- | 206.0 | 1388.2 | Good | 97.4 | 000000012106560 |
NBI report | I-20 WB TO I-75 SB | I-75-3 I75 RMPS- I20 RMP | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (5 spans) | -- | 1988 | -- | 194.9 | 831.1 | Good | 96.3 | 000000012106590 |
NBI report | I-20 WBL | 3I75RMP-2I20RMP-3MRT-2MR | I-20 AND I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (10 spans) | -- | 1988 | -- | 225.1 | 1794.1 | Good | 89.9 | 000000012106520 |
NBI report | I-20R WB TO WINDSO | I-75-3I-75RMP-3I-20RMP-3 | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (11 spans) | -- | 1988 | -- | 240.2 | 2100.2 | Fair | 94.0 | 000000012106580 |
NBI report | I-285 CBL | I-285 RMP TO I-85 SB | IN COLLEGE PARK | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 172.9 | 172.9 | Good | 84.0 | 000000012106400 |
NBI report | I-285 CCBL | I-85-SR 14P-I-85R-I-285R | I-285 & I-85 INTER ON S'S | Prestressed Box Beam or girders - Single or Spread (10 spans) | -- | 1988 | -- | 190.0 | 1661.2 | Good | 85.1 | 000000012106420 |
NBI report | I-285R CB TO SR 27 | I-85- 2 I-85 RMPS-I-285R | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (6 spans) | -- | 1988 | -- | 170.0 | 751.0 | Fair | 94.2 | 000000012106410 |
NBI report | I-75 | CS 3541 BELL STREET | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 115.2 | 115.2 | Good | 80.9 | 000000012106610 |
NBI report | I-75 | M9184 ED'WD- M9150 AUBU' | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1988 | -- | 121.1 | 535.1 | Fair | 74.9 | 000000012106620 |
NBI report | I-75 | M-9157 IRWIN STREET | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 117.1 | 117.1 | Fair | 85.0 | 000000012106630 |
NBI report | I-75 (SBL) TO SR 1 | I-75 + 2 I-75 RAMPS | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1988 | -- | 190.0 | 660.1 | Good | 90.5 | 000000012107200 |
NBI report | I-75 N R TO I-20 W | I-75- 2 I-75 RMPS- I-20R | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 232.0 | 564.0 | Good | 96.3 | 000000012107040 |
NBI report | I-75 N RM TO FULTO | I-75 NB RMP TO I-20 E&WB | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1988 | -- | 102.0 | 199.2 | Fair | 82.7 | 000000012106990 |
NBI report | I-75 R TO I-75 SB | I-75 SB RMP TO JESSIE HI | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 110.9 | 110.9 | Good | 96.9 | 000000012107180 |
NBI report | I-75 RMP N TO M916 | I-75- I-75R- I-20R-M9163 | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (5 spans) | -- | 1988 | -- | 181.1 | 766.1 | Good | 98.0 | 000000012107020 |
NBI report | I-75 RMP TO FULTON | I-75 RMP SB FROM I-20N&S | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1988 | -- | 103.0 | 205.1 | Fair | 82.2 | 000000012107010 |
NBI report | I-75 SB RMP TO I-2 | I-75- 2 I-75 RMPS- I-20R | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 216.9 | 584.0 | Good | 92.6 | 000000012107050 |
NBI report | I-75R N TO SR 410 | M-9157 IRWIN ST- I-75R | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1988 | -- | 115.2 | 370.1 | Fair | 84.5 | 000000012107160 |
NBI report | I-75R NB TO CENTRA | I-75- I-75 RMP- 2 M-RTS | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1988 | -- | 198.2 | 723.1 | Fair | 96.7 | 000000012106680 |
NBI report | I-75R NB TO FULTON | M-9053 GEORGIA AVE. | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 120.1 | 210.0 | Fair | 98.2 | 000000012106690 |
NBI report | I-85R NB TO SR 166 | I-75- 2 I-75 RAMPS | IN SOUTH ATLANTA | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 232.0 | 549.9 | Fair | 96.7 | 000000012106390 |
NBI report | I-85R TO I-285 CB | I-285R-I-85R TO OLD NAT' | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread (7 spans) | -- | 1988 | -- | 243.1 | 1283.2 | Good | 96.6 | 000000012106380 |
NBI report | LINDBERGH DRIVE | NORTH FORK P'TREE CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 55.1 | 140.1 | Good | 89.4 | 000000012106460 |
NBI report | MARTA | I-85 | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 70.9 | -- | -- | -- | 000000012106750 |
NBI report | MARTA | I-85 | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 78.1 | -- | -- | -- | 000000012106760 |
NBI report | MARTA | I-85 RMP SB FROM LEE ST. | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 70.9 | -- | -- | -- | 000000012106770 |
NBI report | MARTA | I-85 RAMP NB | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 100.1 | -- | -- | -- | 000000012106780 |
NBI report | MARTA | I-85 RMP TO AIRPORT NB | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 85.0 | -- | -- | -- | 000000012106790 |
NBI report | MARTA | I-85 RAMP FROM LEE ST. | IN COLLEGE PARK | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 86.0 | -- | -- | -- | 000000012106800 |
NBI report | MARTA | SR 6 CAMP CREEK PKWY. | IN COLLEGE PARK | Concrete Girder and floorbeam system | -- | 1988 | -- | 80.1 | -- | -- | -- | 000000012106960 |
NBI report | MARTA | CS 2046 BROTHERTON ST. | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1988 | -- | 69.9 | -- | -- | -- | 000000012152210 |
NBI report | MARTA | CS 7134 LEE STREET | INSIDE COLLEGE PARK C.L. | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 79.1 | -- | -- | -- | 000000012152230 |
NBI report | MARTA | CS 7134 LEE STREET | INSIDE COLLEGE PARK C.L. | Prestressed Box Beam or girders - Single or Spread | -- | 1988 | -- | 78.1 | -- | -- | -- | 000000012152240 |
NBI report | MCDANIEL STREET | NS RAILROAD (718067U) | IN ATLANTA | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 45.9 | 81.0 | Fair | 71.2 | 000000012104210 |
NBI report | MCDANIEL STREET | I-20 | IN W ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 94.2 | 187.0 | Good | 96.0 | 000000012106470 |
NBI report | MEMORIAL DRIVE | I-75 + I-75 RMP + I-20 R | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1988 | -- | 145.0 | 483.9 | Good | 92.5 | 000000012107080 |
NBI report | PED. BRIDGE | M-9013 E PACES FERRY RD. | IN BUCKHEAD | Concrete Slab | -- | 1988 | -- | 94.2 | -- | -- | -- | 000000012106720 |
NBI report | PED. BRIDGE | M-9073 SPRING STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 69.9 | -- | -- | -- | 000000012106840 |
NBI report | PED. BRIDGE | M-9154 HARRIS STREET | IN CITY OF ATLANTA | Concrete Slab | -- | 1988 | -- | 60.0 | -- | -- | -- | 000000012106890 |
NBI report | PED. BRIDGE | M-9164 P'TREE CENTER | IN CITY OF ATLANTA | Steel Truss - Thru | -- | 1988 | -- | 60.0 | -- | -- | -- | 000000012106920 |
NBI report | PED. BRIDGE | M-9164 P'TREE CENTER | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 53.2 | -- | -- | -- | 000000012106930 |
NBI report | PED. OVERPASS | M-9134 M.L.K. JR DRIVE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 8.2 | -- | -- | -- | 000000012105210 |
NBI report | PED. OVERPASS | CS 1853 LINDEN STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 41.0 | -- | -- | -- | 000000012152190 |
NBI report | PED. OVERPASS | CS 2059 EQUITABLE PLACE | IN CITY OF ATLANTA | Steel Box Beam or girders - Single or Spread | -- | 1988 | -- | 44.9 | -- | -- | -- | 000000012152330 |
NBI report | PEDESTRIAN BRIDGE | SPRING STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 69.9 | -- | -- | -- | 000000012153710 |
NBI report | PEDESTRIAN BRIDGE | SPRING STREET | IN ATLANTA | Concrete Slab | -- | 1988 | -- | 69.9 | -- | -- | -- | 000000012153720 |
NBI report | PEDESTRIAN BRIDGE | SPRING STREET | IN ATLANTA | Concrete Slab | -- | 1988 | -- | 69.9 | -- | -- | -- | 000000012153730 |
NBI report | PEDESTRIAN BRIDGE | HARRIS STREET | IN ATLANTA | Concrete Slab | -- | 1988 | -- | 60.0 | -- | -- | -- | 000000012153740 |
NBI report | PEDESTRIAN BRIDGE | HARRIS STREET | IN ATLANTA | Concrete Slab | -- | 1988 | -- | 60.0 | -- | -- | -- | 000000012153750 |
NBI report | PEDESTRIAN BRIDGE | HARRIS STREET | IN ATLANTA | Concrete Slab | -- | 1988 | -- | 60.0 | -- | -- | -- | 000000012153760 |
NBI report | PEDESTRIAN BRIDGE | N. OUTER LOOP ROAD | IN CITY OF ATLANTA | Steel Box Beam or girders - Single or Spread | -- | 1988 | -- | 44.9 | -- | -- | -- | 000000012153850 |
NBI report | PRYOR ST TO I-75 S | I-75-I-75R-I-20R-M9163-9 | I-20 & I-75 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (6 spans) | -- | 1988 | -- | 225.1 | 998.1 | Good | 94.0 | 000000012107030 |
NBI report | SR 10 (EBL) BR 7E | I-75- HOV & RAMP | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 226.1 | 606.0 | Good | 97.7 | 000000012107190 |
NBI report | SR 139 | SR 14- CS 7026- CSX RR. | IN SOUTH COLLEGE PARK | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1988 | -- | 111.9 | 394.0 | Fair | 79.1 | 000000012106550 |
NBI report | SR10R WBL TO I75 S | I-75 + 3 I-75 RMP -SR 10 | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (6 spans) | -- | 1988 | -- | 220.2 | 1275.0 | Good | 94.3 | 000000012107170 |
NBI report | SR10R WBL TO M9155 | I-75 + 3 I-75 RAMPS | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 190.0 | 562.0 | Good | 96.1 | 000000012107210 |
NBI report | UTILITY BRIDGE | I-75 RAMP | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 29.9 | -- | -- | -- | 000000012107100 |
NBI report | UTILITY BRIDGE | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 16.4 | -- | -- | -- | 000000012107110 |
NBI report | UTILITY BRIDGE | I-75 RAMP | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 29.9 | -- | -- | -- | 000000012107120 |
NBI report | UTILITY BRIDGE | I-75 RAMP | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 184.1 | -- | -- | -- | 000000012107230 |
NBI report | UTILITY BRIDGE | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 126.0 | -- | -- | -- | 000000012107240 |
NBI report | BERNE STREET | ATLANTA BELTLINE | IN EAST ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 80.1 | 80.1 | Good | 98.0 | 000000012104270 |
NBI report | BIRMINGHAM HWY | COOPER SANDY CREEK | 3.6 MI NW OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 1989 | -- | 8.9 | 28.9 | Good | 98.7 | 000000012106970 |
NBI report | BIRMINGHAM HWY | CHICKEN CREEK | 4.7 MI NW OF ALPHARETTA | Concrete Tee beam (3 spans) | -- | 1989 | -- | 40.0 | 120.1 | Good | 75.5 | 000000012106980 |
NBI report | I-20 RMP TO I-75 | I-20R(WINDSOR ST)TO I20E | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 45.9 | 45.9 | Good | 94.5 | 000000012107070 |
NBI report | I-75 RMP TO I-20WB | M9164 & RMP- M9166 & RMP | I-75 & I-20 INTERCHANGE | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1989 | -- | 190.0 | 520.0 | Good | 91.4 | 000000012107060 |
NBI report | I-75R TO PIED/HARR | I-75 SBL- I-75 RAMP | IN ATLANTA | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1989 | -- | 208.0 | 408.2 | Good | 98.8 | 000000012107220 |
NBI report | M.L.K. JR. DRIVE | I-75 | IN ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1989 | -- | 185.0 | 369.1 | Fair | 89.3 | 000000012107090 |
NBI report | MARTA | CS 7134 LEE STREET | INSIDE COLLEGE PARK C.L. | Concrete Girder and floorbeam system | -- | 1989 | -- | 80.1 | -- | -- | -- | 000000012152220 |
NBI report | NORFOLK SOUTHERN R | I-75 RAMP | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 29.9 | -- | -- | -- | 000000012107130 |
NBI report | NORFOLK SOUTHERN R | I-75 | IN N ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 148.0 | -- | -- | -- | 000000012107140 |
NBI report | NORFOLK SOUTHERN R | I-75 RAMP | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 29.9 | -- | -- | -- | 000000012107150 |
NBI report | PED. BRIDGE | M-9154 HARRIS & SPRING | IN CITY OF ATLANTA | Concrete Slab | -- | 1989 | -- | 89.9 | -- | -- | -- | 000000012106880 |
NBI report | PED. BRIDGE | M-9154 HARRIS/P'TREE CNT | IN CITY OF ATLANTA | Concrete Slab | -- | 1989 | -- | 117.1 | -- | -- | -- | 000000012106900 |
NBI report | PED. BRIDGE | M-9155 INTERNATION BLVD. | IN CITY OF ATLANTA | Concrete Slab | -- | 1989 | -- | 60.0 | -- | -- | -- | 000000012106910 |
NBI report | PED. BRIDGE | M-9200 WILLIAMS STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 69.9 | -- | -- | -- | 000000012106940 |
NBI report | PED. BRIDGE | M-9200 WILLIAMS STREET | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 69.9 | -- | -- | -- | 000000012106950 |
NBI report | PED. WALKWAY | JESSIE HILL JR. DRIVE | IN ATLANTA | Concrete Slab | -- | 1989 | -- | 87.9 | -- | -- | -- | 000000012152500 |
NBI report | RUCKER ROAD | FOE KILLER CREEK TRIB | 2.1 MI W OF ALPHARETTA | Prestressed Box beam or girders - Multiple | -- | 1989 | -- | 29.9 | 29.9 | Good | 65.4 | 000000012153070 |
NBI report | WOODRUFF ROAD | BEAR CREEK | 7 MI NW OF PALMETTO | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1989 | -- | 29.9 | 89.9 | Fair | 83.0 | 000000012150450 |
NBI report | CHEROKEE AVE. | I-20 | IN E ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1990 | -- | 103.0 | 205.1 | Good | 94.7 | 000000012107290 |
NBI report | GLENLAKE PKWY. | MARSH CREEK | 6 MI S OF ROSWELL | Concrete Culvert (2 spans) | -- | 1990 | -- | 9.8 | 21.0 | Fair | 83.3 | 000000012152890 |
NBI report | HILL STREET | I-20 | IN E ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1990 | -- | 98.1 | 190.0 | Good | 78.4 | 000000012107280 |
NBI report | MARTA | DONALD LEE HOLLOWELL PKW | IN W ATLANTA | Concrete Tee beam | -- | 1990 | -- | 101.1 | -- | -- | -- | 000000012107250 |
NBI report | PED OVERPASS | SR 8 NORTH AVENUE | IN ATLANTA | Prestressed Slab | -- | 1990 | -- | 66.9 | -- | -- | -- | 000000012107260 |
NBI report | WELCOME ALL ROAD | SOUTH FULTON PKWY | 2.1 MILES NORTH OF UNION | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1990 | -- | 82.0 | 248.0 | Good | 88.5 | 000000012152420 |
NBI report | WHITEHALL STREET | NS RAILROAD (718069H) | IN ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 69.9 | 97.1 | Good | 77.6 | 000000012100080 |
NBI report | BOBBY BROWN PKWY | I-85 | IN COLLEGE PARK | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1991 | -- | 121.1 | 304.1 | Good | 94.4 | 000000012152640 |
NBI report | MANSELL ROAD (EBL) | FOE KILLER CREEK | IN SOUTH ALPHARETTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 65.0 | 165.0 | Good | 67.5 | 000000012152580 |
NBI report | MANSELL ROAD (EBL) | BIG CREEK | IN SOUTH ALPHARETTA | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1991 | -- | 89.9 | 339.9 | Good | 81.8 | 000000012152600 |
NBI report | MANSELL ROAD (WBL) | FOE KILLER CREEK | IN SOUTH ALPHARETTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 65.0 | 165.0 | Good | 64.3 | 000000012152590 |
NBI report | MANSELL ROAD (WBL) | BIG CREEK | IN SOUTH ALPHARETTA | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1991 | -- | 89.9 | 339.9 | Good | 81.8 | 000000012152610 |
NBI report | MARIETTA HIGHWAY | CHATTAHOOCHEE RIVER TRIB | IN SW ROSWELL | Concrete Culvert (3 spans) | -- | 1991 | -- | 8.9 | 29.9 | Good | 80.9 | 000000012107300 |
NBI report | MARTA | CS 813 NORTH AVE. | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1991 | -- | 120.1 | -- | -- | -- | 000000012152450 |
NBI report | MOBILE STREET | MARTA | IN CITY OF ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1991 | -- | 112.9 | 112.9 | Good | 95.2 | 000000012152460 |
NBI report | PED. WALKWAY | M-9166 PRYOR STREET | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 96.1 | -- | -- | -- | 000000012152480 |
NBI report | SIMPSON STREET | MARTA | IN CITY OF ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1991 | -- | 36.1 | 36.1 | Good | 80.7 | 000000012152410 |
NBI report | US 19 | M-9486 MANSELL ROAD | IN SOUTH ALPHARETTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1991 | -- | 107.0 | 200.1 | Good | 93.7 | 000000012107320 |
NBI report | US 29/SR 14 EBL | DEEP CREEK | 3.8 MI N OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1991 | -- | 78.1 | 310.1 | Good | 99.5 | 000000012152520 |
NBI report | US 29/SR 14 WBL | DEEP CREEK | 3.8 MI N OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1991 | -- | 77.1 | 308.1 | Good | 99.4 | 000000012152530 |
NBI report | US 29/SR 14 ALT | WOLF CREEK TRIB. | 2.8 MI N OF UNION CITY | Concrete Culvert (3 spans) | -- | 1991 | -- | 12.1 | 38.1 | Good | 84.1 | 000000012152540 |
NBI report | US 29/SR14 ALT EB | CSX RAILROAD | 3 MILES NORTHWEST OF UNIO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 87.9 | 184.1 | Good | 99.0 | 000000012152550 |
NBI report | US29/SR14ALT WBL | CSX RAILROAD | 3 MILES NW OF UNION CITY | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 87.9 | 184.1 | Good | 99.0 | 000000012152560 |
NBI report | CSX RAILROAD | SR 400 | NORTH ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1992 | -- | 112.9 | -- | -- | -- | 000000012107390 |
NBI report | JONESBORO ROAD | POOLE CREEK | 4.5 MI SE OF EASTPOINT | Concrete Culvert (5 spans) | -- | 1992 | -- | 11.2 | 57.1 | Good | 83.6 | 000000012107310 |
NBI report | LORIDANS DRIVE | SR 400 | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1992 | -- | 96.1 | 350.1 | Good | 84.8 | 000000012107510 |
NBI report | MARTA | SR 400 (SBL) | NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 121.1 | -- | -- | -- | 000000012107380 |
NBI report | MARTA | M-9245 OLD IVY ROAD | IN NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 64.0 | -- | -- | -- | 000000012152620 |
NBI report | PEACHTREE ROAD | SR 400 | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 85.0 | 221.1 | Good | 90.9 | 000000012107330 |
NBI report | PED. BRIDGE | SR 400 | NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 73.2 | -- | -- | -- | 000000012107410 |
NBI report | R. HUMPHREY BLDG. | SR 400 | IN N ATLANTA | Prestressed Box Beam or girders - Single or Spread | -- | 1992 | -- | 55.1 | -- | -- | -- | 000000012107420 |
NBI report | SR 141 (LOOP-CONN) | SR 400 | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 75.1 | 199.2 | Good | 98.7 | 000000012107340 |
NBI report | SR 154 SPUR | I-20 | IN E ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1992 | -- | 118.1 | 223.1 | Good | 85.0 | 000000012107570 |
NBI report | SR 400 (NBL) | M-9323 SIDNEY MARCUS BLD | NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1992 | -- | 67.9 | 243.1 | Good | 95.2 | 000000012107360 |
NBI report | SR 400 (NBL) | M-9245 OLD IVY ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 65.0 | 180.1 | Good | 94.7 | 000000012107430 |
NBI report | SR 400 (NBL) | CR 2499 + NANCY CRK TRIB | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1992 | -- | 109.9 | 660.1 | Good | 77.0 | 000000012107450 |
NBI report | SR 400 (NBL) | NANCY CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1992 | -- | 104.0 | 421.9 | Good | 94.7 | 000000012107470 |
NBI report | SR 400 (SBL) | M-9323 SIDNEY MARCUS BLD | NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1992 | -- | 67.9 | 243.1 | Good | 89.8 | 000000012107370 |
NBI report | SR 400 (SBL) | M-9245 OLD IVY ROAD | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 64.0 | 179.1 | Good | 94.7 | 000000012107440 |
NBI report | SR 400 (SBL) | CR 2499 + NANCY CRK TRIB | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1992 | -- | 109.9 | 692.0 | Good | 82.7 | 000000012107460 |
NBI report | SR 400 (SBL) | NANCY CREEK | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1992 | -- | 104.0 | 421.9 | Good | 94.7 | 000000012107480 |
NBI report | UTILITY BRIDGE | SR 400 | NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 9.2 | -- | -- | -- | 000000012107400 |
NBI report | WIEUCA ROAD | SR 400 | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1992 | -- | 122.1 | 288.1 | Good | 66.0 | 000000012107500 |
NBI report | BOULEVARD | I-20 | IN E ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 107.0 | 200.1 | Good | 87.8 | 000000012104240 |
NBI report | GLENRIDGE PWY | SR 400 + 2 SR 400 RAMPS | IN N FULTON | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1993 | -- | 107.9 | 465.9 | Good | 84.0 | 000000012107490 |
NBI report | HUTCHENSON FERRY R | DRY BRANCH | 6.5 MI W OF PALMETTO | Concrete Culvert (3 spans) | -- | 1993 | -- | 8.9 | 28.9 | Good | 99.7 | 000000012102800 |
NBI report | JOHNSON FERRY RD | SR 400 + 2 SR 400 RAMPS | IN N FULTON | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1993 | -- | 128.0 | 494.1 | Good | 74.3 | 000000012107540 |
NBI report | MERK ROAD | CAMP CREEK | 7 MI N OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1993 | -- | 40.0 | 200.1 | Good | 82.6 | 000000012150590 |
NBI report | NORTHLAND DRIVE | SR 400 | IN N FULTON | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1993 | -- | 106.0 | 306.1 | Good | 68.6 | 000000012107530 |
NBI report | SR 400 (NBL) | I-85 | IN N ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 279.9 | 1825.2 | Fair | 64.9 | 000000012107350 |
NBI report | WINDSOR PARKWAY | SR 400 | IN N FULTON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 122.1 | 278.9 | Good | 73.1 | 000000012107520 |
NBI report | POWERS FERRY RD | LONG ISLAND CREEK | 1.3 MI N OF MT PARON ROAD | Steel Stringer/Multi-beam or girder | -- | 1993 | 2004 | 46.9 | 46.9 | Fair | 47.2 | 000000012104510 |
NBI report | CAMBELLTON-REDWINE | WHITE OAK CREEK | 1 MI N OF COWETA CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 65.0 | 194.9 | Good | 92.0 | 000000012107550 |
NBI report | CAMP-REDWINE ROAD | BEAR CREEK | 8 MI N OF COWETA CO LINE | Concrete Tee beam (7 spans) | -- | 1994 | -- | 40.0 | 279.9 | Good | 98.4 | 000000012107560 |
NBI report | CANOPY BRIDGE | SR 10 FREEDOM PARKWAY | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 40.0 | -- | -- | -- | 000000012107590 |
NBI report | HIGHLAND AVE. | SR 10 | IN NE ATLANTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1994 | -- | 199.2 | 384.9 | Fair | 96.0 | 000000012107620 |
NBI report | PED. BRIDGE | SR 10 FREEDOM PARKWAY | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 89.9 | -- | -- | -- | 000000012107640 |
NBI report | RANDOLPH STREET | SR 10 | IN ATLANTA | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1994 | -- | 112.9 | 208.0 | Fair | 93.3 | 000000012107630 |
NBI report | SR 10 | NS RAILROAD | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 86.0 | 248.0 | Fair | 75.6 | 000000012107600 |
NBI report | SR 10 | SR 10 RAMP | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 86.9 | 150.9 | Good | 94.5 | 000000012107610 |
NBI report | US 29, SR 14 ALT | PEA CREEK | 4.1 MI NW OF FAIRBURN | Concrete Culvert (2 spans) | -- | 1994 | -- | 9.8 | 21.0 | Good | 84.8 | 000000012152650 |
NBI report | US 29, SR 14 ALT ( | LINE CREEK | 4.3 MI W OF UNION CITY | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1994 | -- | 40.0 | 180.1 | Good | 98.6 | 000000012152660 |
NBI report | US 29, SR 14 ALT ( | LINE CREEK | 4.3 MI W OF UNION CITY | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1994 | -- | 40.0 | 200.1 | Good | 98.6 | 000000012152670 |
NBI report | CEDAR GROVE ROAD ( | LITTLE PEA CREEK | 8 MI N OF PALMETTO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1995 | -- | 60.0 | 149.9 | Good | 99.7 | 000000012107580 |
NBI report | CROSSVILLE ROAD | HOG WALLER CREEK TRIB | 4.5 MI W OF ALPHARETTA | Concrete Culvert (4 spans) | -- | 1995 | -- | 6.9 | 29.9 | Good | 77.2 | 000000012107650 |
NBI report | HAYNES BRIDGE RD | BIG CREEK | 2.4 MI S OF ALPHARETTA | Concrete Slab (3 spans) | -- | 1995 | -- | 44.9 | 134.8 | Fair | 87.0 | 000000012152730 |
NBI report | HOPEWELL ROAD | CHICKEN CREEK TRIB | 3.6 MI N OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 1995 | -- | 7.9 | 26.9 | Good | 98.1 | 000000012102820 |
NBI report | ONO ROAD | BEAR CREEK | 3 MI NE OF PALMETTO | Prestressed Channel beam (2 spans) | -- | 1995 | -- | 29.9 | 60.0 | Fair | 61.0 | 000000012152740 |
NBI report | PED OVERPASS | SR 8 NORTH AVENUE | IN ATLANTA | Steel Girder and floorbeam system | -- | 1995 | -- | 107.0 | -- | -- | -- | 000000012107660 |
NBI report | SR 120 EBL | BIG CREEK | IN ALPHARETTA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1995 | -- | 38.1 | 190.0 | Fair | 86.1 | 000000012152720 |
NBI report | CREEKWOOD ROAD | BORUM SPRINGS C | 2 MI SW OF FAIRBURN | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1996 | -- | 29.9 | 60.0 | Fair | 62.8 | 000000012152750 |
NBI report | DESERT DRIVE | CAMP CREEK | IN WEST COLLEGE PARK | Concrete Slab (2 spans) | -- | 1996 | -- | 29.9 | 60.0 | Good | 85.4 | 000000012152680 |
NBI report | ENON ROAD | CAMP CREEK TRIB | 7 MI N OF FAIRBURN | Concrete Culvert (3 spans) | -- | 1996 | -- | 16.1 | 50.9 | Good | 99.0 | 000000012152690 |
NBI report | PEDESTRIAN TO DOME | M-9315 INTERNAT | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 65.0 | -- | -- | -- | 000000012152800 |
NBI report Bridgehunter | M.L.K. JR. DRIVE | PARKING LOT & RICH'S | AT RICH'S DOWNTOWN | Concrete Stringer/Multi-beam or girder (4 spans) | -- | 1996 | 2018 | 84.0 | 337.9 | Good | 72.5 | 000000012152390 |
NBI report | BUTNER ROAD | DEEP CREEK | 6.4 MI NW UNION CITY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1997 | -- | 69.9 | 259.9 | Good | 98.2 | 000000012152710 |
NBI report | MONTGOMERY FERRY D | ATLANTA BELT LINE | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 69.9 | 69.9 | Good | 48.4 | 000000012152780 |
NBI report | TELL ROAD | CAMP CREEK TRIB | IN SOUTH WEST ATLANTA | Concrete Slab (3 spans) | -- | 1997 | -- | 35.1 | 103.0 | Good | 87.9 | 000000012152790 |
NBI report | JONESBORO ROAD | MORNING CREEK | 4.6 MI SW OF UNION CITY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1998 | -- | 113.9 | 428.2 | Good | 96.5 | 000000012152820 |
NBI report | STATE BRIDGE ROAD | JOHNS CREEK | 6.2 MI SE OF ALPHARETT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 69.9 | 140.1 | Good | 98.2 | 000000012152850 |
NBI report | STONE ROAD | NORTH FORK CAMP CREEK | IN SOUTHWEST ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 81.0 | 81.0 | Good | 88.4 | 000000012152770 |
NBI report | WINWARD PKWY. | BIG CREEK TRIBUTARY | IN ALPHARETTA C. L. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 32.2 | 96.1 | Good | 77.9 | 000000012152860 |
NBI report | BROWNLEE ROAD | UTOY CREEK | IN WEST ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 86.9 | 86.9 | Good | 87.9 | 000000012152870 |
NBI report | HALL ROAD | LINE CREEK TRIBUTARY | 5 MI NW OF FAIRBURN | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 29.9 | 29.9 | Fair | 81.8 | 000000012152830 |
NBI report | HALL ROAD | LINE CREEK | 5 MI NW OF FAIRBURN | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 29.9 | 29.9 | Good | 83.8 | 000000012152840 |
NBI report | OAKLEY INT. BLVD. | TRICKUM CREEK | 4 MI S OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 74.2 | 182.1 | Good | 93.4 | 000000012152810 |
NBI report | O. B. COOK ROAD | MORNING CREEK TRIB | 4 MI NE OF UNION CITY | Concrete Culvert (3 spans) | -- | 2000 | -- | 7.9 | 25.9 | Good | 99.2 | 000000012152910 |
NBI report | OLD FAIRBURN ROAD | WOLF CREEK | 4.2 MI N OF UNION CITY | Concrete Culvert (4 spans) | -- | 2000 | -- | 12.1 | 51.8 | Good | 99.3 | 000000012152900 |
NBI report | SOUTH FULTON PKWY. | CEDAR BRANCH | 4 MI W OF PALMETTO | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2000 | -- | 129.9 | 600.1 | Good | 93.1 | 000000012153000 |
NBI report | HARRIS ROAD | FOE KILLER CREEK TRIB | 2 MI SW OF ALPHARETTA | Concrete Culvert (3 spans) | -- | 2001 | -- | 9.8 | 33.1 | Good | 84.9 | 000000012152920 |
NBI report | HOLLYWOOD ROAD | PROCTOR CREEK | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2001 | -- | 107.0 | 264.1 | Good | 89.3 | 000000012152940 |
NBI report | JONESBORO ROAD | SOUTH RIVER | IN SOUTH ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 83.0 | 132.9 | Good | 85.3 | 000000012152970 |
NBI report | LAKEWOOD AVE. | NS RAILROAD | .1 MI N OF JCT SR 42 SPUR | Steel Stringer/Multi-beam or girder | -- | 2001 | -- | 129.9 | 129.9 | Good | 91.4 | 000000012152980 |
NBI report | RICO ROAD | MOSS CREEK | 6 MI NW OF PALMETTO | Prestressed Box beam or girders - Multiple | -- | 2001 | -- | 29.9 | 29.9 | Good | 79.3 | 000000012152930 |
NBI report | 400 RAMP TO MARTA | SR 400 (US 19)-MARTA | 5.15 MI S OF ROSWELL | Steel Stringer/Multi-beam or girder (7 spans) | -- | 2002 | -- | 200.1 | 1112.9 | Good | 83.0 | 000000012153090 |
NBI report | FAYETTEVILLE ROAD | CSX RAILROAD | 2 MILES FROM FAIRBURN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2002 | -- | 59.1 | 170.0 | Good | 90.4 | 000000012153420 |
NBI report | PINE GROVE ROAD | WILLEO CREEK | AT W ROSWELL CITY LIMITS | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2002 | -- | 66.9 | 200.1 | Good | 83.3 | 000000012152960 |
NBI report | US 19 | M-9412 WINDWARD PKWY. | N ALPHARETTA CITY LIMITS | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2002 | -- | 130.9 | 341.9 | Fair | 82.6 | 000000012152950 |
NBI report | WATERWORKS ROAD | CEDAR CREEK | 1 MI W OF PALMETTO | Prestressed Box beam or girders - Multiple | -- | 2002 | -- | 29.9 | 29.9 | Fair | 67.1 | 000000012152990 |
NBI report | OLD FAIRBURN ROAD | CAMP CREEK | 4.7 MI W OF COLLEGE PARK | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 65.9 | 184.1 | Good | 77.6 | 000000012153010 |
NBI report | 17TH STREET | 18TH STREET,NS RR | IN N ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2004 | -- | 130.9 | 204.1 | Good | 89.8 | 000000012153350 |
NBI report | FAIRBURN ROAD | CSX RAILROAD (638628J) | 7 MI WEST OF ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 77.1 | 210.0 | Good | 82.0 | 000000012153180 |
NBI report | FAIRBURN ROAD | CSX RAILROAD | IN SOUTHWEST ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 87.9 | 255.9 | Good | 94.8 | 000000012153470 |
NBI report | FREEMANVILLE ROAD | CHICKEN CREEK | 2.5 MI N OF ALPHARETTA C | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 69.9 | 170.0 | Good | 98.7 | 000000012153030 |
NBI report | NORTH COMMERCE DRI | CAMP CREEK | IN EASTPOINT CITY LIMITS | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 200.1 | 450.2 | Good | 73.0 | 000000012153230 |
NBI report | NORTHCUTT ROAD | PEA CREEK | 4 MI NW OF FAIRBURN | Prestressed Box beam or girders - Multiple | -- | 2004 | -- | 29.9 | 29.9 | Fair | 65.4 | 000000012153020 |
NBI report | SOUTH FULTON PARKW | BEAR CREEK | 4.8 MILES WEST OF FAIRBUR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 53.2 | 149.0 | Good | 79.7 | 000000012153160 |
NBI report | STATE BRIDGE ROAD | JOHNS CREEK | 6 MILES SOUTH EAST OF ALP | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 69.9 | 140.1 | Good | 81.2 | 000000012153190 |
NBI report Bridgehunter | 17TH. STREET | I-75 & I-85 & RAMPS | IN ATLANTA | Steel Box beam or girders - Multiple (3 spans) | -- | 2005 | -- | 337.9 | 960.0 | Good | 91.1 | 000000012153050 |
NBI report | ENON ROAD | CAMP CREEK | 12 MI W OF ATLANTA | Concrete Tee beam (4 spans) | -- | 2005 | -- | 40.0 | 160.1 | Good | 96.2 | 000000012153040 |
NBI report | I-85 RMP TO 17 ST | SR 401 SOUTH RAMP TO 14T | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 105.0 | 198.2 | Good | 95.9 | 000000012153060 |
NBI report | REDWINE ROAD | CAMP CREEK | IN ATLANTA CITY LIMITS | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2005 | -- | 50.9 | 141.1 | Good | 84.4 | 000000012153430 |
NBI report | BEN HILL ROAD | TEMPLE GROVE CREEK | 6 MI NE OF FAIRBURN | Concrete Culvert (3 spans) | -- | 2006 | -- | 11.2 | 36.1 | Good | 84.3 | 000000012153100 |
NBI report | COCHRAN MILL ROAD | LITTLE PEA CREEK | 6.5 MILES NORTH WEST OF P | Concrete Culvert (2 spans) | -- | 2006 | -- | 11.2 | 24.0 | Good | 99.9 | 000000012153110 |
NBI report | FIFTH STREET | I-75/I-85 NORTH & SOUTH | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2006 | -- | 137.1 | 256.9 | Good | 93.9 | 000000012153210 |
NBI report | JOHNSON ROAD | PEEKS CREEK | I MILE EAST OF PALMETTO | Concrete Culvert (3 spans) | -- | 2006 | -- | 6.9 | 23.0 | Good | 99.9 | 000000012153080 |
NBI report | MCCLURE ROAD | LINE CREEK | 3 MILES NORTH WEST OF FAI | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2006 | -- | 40.0 | 80.1 | Good | 92.2 | 000000012153170 |
NBI report | NOR SOU RAILROAD | M-9219 ROXBORO R | IN ATLANTA | Steel Stringer/Multi-beam or girder | -- | 2006 | -- | 69.9 | -- | -- | -- | 000000012153140 |
NBI report | OAKLEY INDUSTRIAL | CSX RAILROAD | 2 MI OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2006 | -- | 139.1 | 295.0 | Fair | 77.7 | 000000012153450 |
NBI report | RICO-TATUM ROAD | CEDAR BRANCH | 4 MILES WEST OF PALMETO | Concrete Culvert | -- | 2006 | -- | 32.2 | 32.2 | Good | 81.2 | 000000012153150 |
NBI report | UPPER HEMBREE ROAD | FOE KILLER CREEK | 2 MI. SW OF ALPHARETTA | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 2006 | -- | 29.9 | 89.9 | Good | 77.4 | 000000012153130 |
NBI report | PEACHTREE STREET | CSX RAILROAD | IN CITY OF ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 2007 | -- | 71.9 | 276.9 | Good | 80.2 | 000000012153200 |
NBI report | STONEWALL TELL ROA | CAMP CREEK | 6.9 MI. NORTH OF UNION CI | Concrete Tee beam (5 spans) | -- | 2007 | -- | 40.0 | 171.9 | Fair | 97.6 | 000000012153120 |
NBI report | CASCADE-PALMETTO R | DEEP CREEK | 7.5 MILES NORTH OF FAIRBU | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2008 | -- | 100.1 | 259.9 | Good | 96.1 | 000000012153240 |
NBI report | FULTON INDUSTRIAL | SANDY CREEK | IN W ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2008 | -- | 60.0 | 160.1 | Good | 98.0 | 000000012153280 |
NBI report | MARIETTA BLVD NW | CHATTAHOOCHEE RIVER | FULTON-COBB COUNTY LINE | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2008 | -- | 140.1 | 560.1 | Good | 70.1 | 000000012153220 |
NBI report | MARTA (MONORAIL) | I-85 (SR 403) | 0.5 MI NW OF ATL AIRPORT | Steel Box beam or girders - Multiple | -- | 2008 | -- | 20.0 | -- | -- | -- | 000000012153250 |
NBI report | MARTA (MONORAIL) | ROOSEVELT HWY | 1 MI NW OF ATL AIRPORT | Prestressed Box beam or girders - Multiple | -- | 2008 | -- | 140.1 | -- | -- | -- | 000000012153260 |
NBI report | MARTA (MONORAIL) | W POINT AVE. AND CSX RR | 0.5 MI NW OF ATL AIRPORT | Prestressed Box beam or girders - Multiple | -- | 2008 | -- | 14.1 | -- | -- | -- | 000000012153270 |
NBI report | 14TH STREET | I-75 | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 167.0 | 396.0 | Good | 74.2 | 000000012153370 |
NBI report | HEMBREE ROAD | FOE KILLER CREEK | 2 MILES SW OF ALPHARETTA | Prestressed Stringer/Multi-beam or girder | -- | 2009 | -- | 95.1 | 95.1 | Good | 80.7 | 000000012153320 |
NBI report | OLD ROSWELL ROAD | FOE KILLER CREEK | 2.7 MILES SOUTH OF ALPHAR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 71.9 | 148.0 | Good | 90.6 | 000000012153310 |
NBI report | SR 70 FULTON INDUS | CAMP CREEK | 7.9 MILES N. OF FAIRBURN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 125.0 | 351.1 | Good | 98.5 | 000000012153330 |
NBI report | HOLLYWOOD ROAD | NS RAILROAD | NW ATLANTA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 80.1 | 200.1 | Good | 97.5 | 000000012153360 |
NBI report | IVAN ALLEN JR BLVD | NS RR / PARKING ACCESS | IN NW ATLANTA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2010 | -- | 169.0 | 259.9 | Good | 99.6 | 000000012153390 |
NBI report | MCGINNIS FERRY RD | JOHNS CREEK | 6.7 MI E OF ALPHARETTA | Concrete Culvert (4 spans) | -- | 2010 | -- | 8.9 | 40.0 | Good | 84.9 | 000000012153340 |
NBI report | P'TREE-DUNWOODY RD | NANCY CREEK | 4 MI N JCT OF P'TREE ST. | Concrete Tee beam (3 spans) | -- | 2010 | -- | 60.0 | 120.1 | Good | 65.1 | 000000012153290 |
NBI report | RAMP I-75 TO 17TH | WILLIAMS & 16TH ST | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 2010 | -- | 123.0 | 830.1 | Good | 90.1 | 000000012153380 |
NBI report | RIVERSIDE DRIVE | MARSH CREEK | 0.4 MI N OF JCT M-9252 | Concrete Tee beam | -- | 2010 | -- | 43.0 | 43.0 | Good | 79.1 | 000000012153300 |
NBI report | SR 280 JAMES JACKS | CHATT. RIVER - NS RR. | COBB-FULTON CO LINE | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2010 | -- | 151.9 | 762.2 | Good | 90.1 | 000000012153400 |
NBI report | DOUGLAS ROAD | CANEY CREEK | IN CITY LIMITS OF ALPHARE | Prestressed Box beam or girders - Multiple | -- | 2011 | -- | 47.9 | 47.9 | Good | 88.9 | 000000012153410 |
NBI report | HAMMOND DRIVE | SR 400 (US 19) | 0.7 MILES NORTH OF I-285 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 2011 | -- | 152.9 | 370.1 | Good | 92.2 | 000000012153480 |
NBI report | KIMBALL BRIDGE RD | BIG CREEK | 2 MI SE OF ALPHARETTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2011 | -- | 95.1 | 210.0 | Good | 96.0 | 000000012153520 |
NBI report | McGINNIS FERRY RD | CHATTAHOOCHEE RIVER | GWINNETT-FULTON COUNTY LI | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2011 | -- | 145.0 | 303.2 | Good | 92.4 | 000000012153530 |
NBI report | BETHSAIDA ROAD | MORNING CREEK TRIB. | 3.4 MILES EAST OF UNION C | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2012 | -- | 29.9 | 89.9 | Good | 80.0 | 000000012153440 |
NBI report | COCHRAN MILL ROAD | PEA CREEK | 7 MI NW OF PALMETTO | Concrete Culvert | -- | 2012 | -- | 60.0 | 60.0 | Good | 88.6 | 000000012153510 |
NBI report | DONALD LEE HOWELL | CSX RAILROAD(ABANDONED) | IN WEST ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 2012 | -- | 73.2 | 73.2 | Good | 92.8 | 000000012153490 |
NBI report | FAIRBURN ROAD | CSX RAILROAD | IN SOUTH WEST ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 2012 | -- | 109.9 | 109.9 | Good | 90.6 | 000000012153460 |
NBI report | MITCHELL STREET | NS RAILROAD | IN SW ATLANTA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 2012 | -- | 162.1 | 551.9 | Good | 90.4 | 000000012153500 |
NBI report | ADAMS DRIVE | SOUTH UTOY CREEK | IN SOUTHWEST ATLANTA | Concrete Box Beam or girders - Single or Spread (3 spans) | -- | 2013 | -- | 35.1 | 105.0 | Good | 79.8 | 000000012153590 |
NBI report | COBB PARKWAY/US 41 | CHATTAHOOCHEE RIVER | IN N FULTON | Concrete Stringer/Multi-beam or girder (10 spans) | -- | 2013 | -- | 140.1 | 529.9 | Good | 86.5 | 000000012153620 |
NBI report | CSX RAILROAD | DONALD LEE HOLLOWELL PKW | IN WEST ATLANTA | Steel Girder and floorbeam system | -- | 2013 | -- | 89.9 | -- | -- | -- | 000000012153600 |
NBI report | EDGEWOOD AVENUE | ATLANTA BELT-LINE PATH | IN ATLANTA | Concrete Tee beam (2 spans) | NR eligible | 2013 | -- | 132.9 | 183.1 | Good | 75.4 | 000000012153580 |
NBI report | I-85 | BUFORD HIGHWAY | IN NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2014 | -- | 137.1 | 232.0 | Good | 76.1 | 000000012153550 |
NBI report | SR 400 RAMP | SR 13, I-85, SR 400, AND | IN NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (20 spans) | -- | 2014 | -- | 161.1 | 2748.2 | Good | 57.2 | 000000012153570 |
NBI report | SR 403/ I-85 RAMP | SIDNEY MARCUS BLVD | IN NORTH ATLANTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2014 | -- | 149.9 | 404.9 | Good | 71.8 | 000000012153560 |
NBI report | BELL ROAD | CAULEY CREEK | 9 MI E OF ALPHARETTA | Prestressed Stringer/Multi-beam or girder | -- | 2015 | -- | 80.1 | 80.1 | Good | 77.7 | 000000012153670 |
NBI report | ENCORE PARKWAY | SR 400 (US 19) | IN ALPHARETTA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2015 | -- | 150.9 | 301.9 | Good | 67.4 | 000000012153640 |
NBI report | NORTH RIDGE ROAD | SR 400 (US 19) | 5.2 MI N OF I-285 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2015 | -- | 110.9 | 315.0 | Good | 88.3 | 000000012153630 |
NBI report | PARSONS ROAD | JOHNS CREEK | 6 MI SE OF ALPHARETTA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2015 | -- | 40.0 | 120.1 | Good | 96.3 | 000000012153680 |
NBI report | PORTER TERRY ROAD | LITTLE PEA CREEK | 6 MI N OF PALMETTO | Concrete Culvert (3 spans) | -- | 2015 | -- | 12.1 | 38.1 | Good | 70.2 | 000000012153650 |
NBI report | BUFFINGTON ROAD | SHANNON CREEK | 1 MI E OF UNION CITY | Prestressed Box beam or girders - Multiple (5 spans) | -- | 2016 | -- | 40.0 | 200.1 | Good | 79.0 | 000000012153610 |
NBI report | JOHNSON ROAD | LINE CREEK | FULTON-FAYETTE CO LINE | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2016 | -- | 29.9 | 89.9 | Good | 99.9 | 000000012153660 |
NBI report | COURTLAND STREET | DECATUR ST-CSX RR | IN ATLANTA | Prestressed Stringer/Multi-beam or girder (12 spans) | -- | 2018 | -- | 141.1 | 1130.6 | Good | 76.0 | 000000012153700 |
NBI report | P'TREE DUNWOODY RD | PEACHTREE DUNWOODY | SANDY SPRINGS | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 9.5 | -- | -- | -- | 000000012153830 |
NBI report | PEDESTRIAN BRIDGE | PEACHTREE DUNWOODY ROAD | IN SANDY SPRINGS | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 165.0 | -- | -- | -- | 000000012153810 |
NBI report | PEDESTRIAN TO DOME | M-9315 INTERNAT | IN CITY OF ATLANTA | Other | -- | 2018 | -- | 1509.3 | -- | -- | -- | 000000012153790 |
NBI report | RUCKER ROAD | FOE KILLER CREEK | 1.9 MI W OF ALPHARETTA | Concrete Culvert | -- | 2018 | -- | 44.0 | 44.9 | Good | 80.0 | 000000012153800 |
NBI report | SR00003 | PEDESTRIAN BRIDGE | IN ATLANTA | Prestressed Stringer/Multi-beam or girder | -- | 2018 | -- | 123.0 | -- | -- | -- | 000000012153820 |
NBI report | PEDESTRIAN BRIDGE | DELTA BLVD | IN CITY OF ATLANTA | Concrete Box Beam or girders - Single or Spread | -- | 2019 | -- | 9.5 | -- | -- | -- | 000000012153840 |