Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | CNRL RR | LINCOLN DR(MS 1230) | SW GREENUP | Concrete Slab | -- | -- | -- | 26.9 | -- | -- | -- | 018990100000000 |
NBI report | CNRL RR | JEFFERSON ST(MS6020B | SW GREENUP | Concrete Slab | -- | -- | -- | 22.0 | -- | -- | -- | 018990300000000 |
NBI report | TR-9 | CROOKED CREEK | 1.5 MI NE PT PLEASAN | Concrete Slab | -- | 1909 | -- | 24.9 | 25.9 | Fair | 62.4 | 040304200000000 |
NBI report | TR 36 | BUSH CREEK | 4.0 MI NE NEOGA | Steel Stringer/Multi-beam or girder | -- | 1916 | -- | 26.6 | 28.9 | Fair | 48.1 | 018304200000000 |
NBI report Bridgehunter | SBI 11 A | EMBARRAS R OVERFLOW | .5 MI W OF GREENUP | Concrete Other (2 spans) | -- | 1920 | -- | 41.0 | 86.0 | Poor | 22.3 | 018002100000000 |
NBI report Bridgehunter | TR 212 | BELL BRANCH | NE GREENUP W IL 130 | Concrete Other | -- | 1922 | -- | 31.5 | 33.1 | Fair | 78.8 | 018307300000000 |
NBI report | CH 24 | TRIB MUDDY CREEK | 2 MI SE OF TOLEDO | Concrete Culvert (4 spans) | -- | 1922 | 1958 | 5.9 | 28.9 | Fair | 65.1 | 018500300000000 |
NBI report | IL 121 (FAP 773) | LONG POINT BRANCH | 1.3MI E MONTROSE RD | Prestressed Box beam or girders - Multiple | -- | 1928 | 1981 | 51.5 | 53.2 | Fair | 84.3 | 018002800000000 |
NBI report | FAP 116 (IL 130) | BELL BRANCH | N EDGE OF GREENUP | Concrete Slab | -- | 1931 | -- | 24.9 | 25.9 | Fair | 97.2 | 018002400000000 |
NBI report | FAP 116 (IL 130) | CSXT RR | .5 MI S US 40 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1931 | 1980 | 44.9 | 128.0 | Fair | 86.0 | 018002600000000 |
NBI report | IL 121 (FAP 773) | OTTER CREEK | 3.0 MI E 7 MI CURVE | Concrete Culvert (2 spans) | -- | 1933 | 1971 | 11.2 | 24.9 | Poor | 69.7 | 018200400000000 |
NBI report | FAS 700 | RANGE CREEK | 2.8 E UNION CENTER | Steel Stringer/Multi-beam or girder | -- | 1939 | -- | 41.0 | 44.9 | Good | 81.2 | 018302000000000 |
NBI report | CH 4(FAS 702) | RANGE CREEK | 3.0 MI SE GREENUP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1941 | -- | 49.2 | 129.6 | Fair | 79.8 | 018300800000000 |
NBI report | TR 7 B | MUDDY CREEK | 1.5 MI E OF TRILLA | Concrete Culvert (2 spans) | -- | 1949 | -- | 9.8 | 22.0 | Fair | 78.5 | 018500500000000 |
NBI report | US 40(FAS 1707) | BIG MUDDY CREEK | 1.25 MI E WOODBURY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1949 | 1992 | 82.4 | 296.6 | Fair | 96.0 | 018000700000000 |
NBI report | CH 1(FAS 656) | LONG POINT CREEK | 1.5 MI E OF NEOGA | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 22.3 | Fair | 86.9 | 018500200000000 |
NBI report | US 40(FAS 1707) | EMBARRAS RIVER | .7 MI W OF GREENUP | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1950 | -- | 88.3 | 456.7 | Poor | 41.2 | 018000800000000 |
NBI report | US 40(FAS 1707) | STREAM | 3.39 MI E OF GREENUP | Concrete Culvert (3 spans) | -- | 1950 | -- | 7.2 | 25.3 | Fair | 96.4 | 018200200000000 |
NBI report | US 40(FAS 1707) | MILL ROAD(MS 5990) | GREENUP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1950 | 1990 | 74.2 | 173.6 | Fair | 82.3 | 018000900000000 |
NBI report | US 40(FAS 1707) | LINCOLN ST(MS 1230) | GREENUP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1950 | 1990 | 66.9 | 175.5 | Fair | 95.3 | 018001000000000 |
NBI report | TR 113 | MUDDY CREEK | 1.6 MI NW TOLEDO | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1951 | -- | 51.5 | 136.2 | Good | 74.1 | 018301700000000 |
NBI report | TR 104(FAS 1657) | MUDDY CREEK | .7 MI N WOODBURY | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1955 | 1995 | 63.7 | 182.8 | Good | 95.8 | 018301300000000 |
NBI report | FAS 702(CH 4) | STREAM | 1.9 MI W HAZEL DELL | Concrete Culvert (2 spans) | -- | 1956 | -- | 10.8 | 22.0 | Good | 80.1 | 018500000000000 |
NBI report | FAS 702(CH 4) | CROOKED CREEK | 0.5 MI W HAZEL DELL | Concrete Culvert (2 spans) | -- | 1956 | -- | 11.2 | 24.9 | Good | 67.1 | 018500100000000 |
NBI report | TR 14 A | BUSH CR & LK MATTOON | 2.5 MI NE OF NEOGA | Concrete Channel beam (2 spans) | -- | 1957 | -- | 28.9 | 60.0 | Fair | 90.3 | 018302700000000 |
NBI report | CH 18(FAS 674) | LAKE MATTOON | 2.5 MI N NEOGA | Concrete Channel beam (2 spans) | -- | 1958 | -- | 29.2 | 62.0 | Fair | 81.7 | 018300400000000 |
NBI report | CH 19 | LAKE MATTOON | 1.5 MI N NEOGA | Concrete Channel beam (4 spans) | -- | 1958 | -- | 29.9 | 110.9 | Poor | 35.9 | 018301100000000 |
NBI report | CH 25(FAS 700) | HURRICANE CREEK | .5 MI W MAPLE POINT | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1958 | -- | 54.5 | 166.3 | Good | 87.8 | 018300500000000 |
NBI report | TR 27 | LAKE MATTOON | 2.5 MI NE OF NEOGA | Concrete Channel beam (2 spans) | -- | 1958 | -- | 28.9 | 62.0 | Fair | 95.6 | 018303500000000 |
NBI report | TR 158 | BRUCE CREEK | 2 MI SE OF JEWETT | Concrete Culvert (2 spans) | -- | 1959 | -- | 10.5 | 23.0 | Fair | 89.5 | 018500600000000 |
NBI report | IL 121 (FAP 773) | EMBARRAS RIVER | NW CL GREENUP | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | 1995 | 82.7 | 298.6 | Fair | 86.0 | 018001900000000 |
NBI report | IL 121 (FAP 773) | COTTONWOOD CREEK | 1 MI SE OF TOLEDO | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 2000 | 45.6 | 127.6 | Fair | 87.2 | 018001800000000 |
NBI report | CH 3(FAS 1653) | I-57 | .25 MI NE SHELBY LIN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 69.9 | 230.0 | Fair | 84.4 | 018005500000000 |
NBI report | CH 5(FAS 703) | MUDDY CREEK | 1.3 MI S JEWETT | Prestressed Box beam or girders - Multiple (4 spans) | -- | 1963 | -- | 70.5 | 283.2 | Fair | 71.1 | 018301000000000 |
NBI report | FAS 656 | I-57 | .25 MI E OF NEOGA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 67.6 | 224.4 | Fair | 74.0 | 018001500000000 |
NBI report | I-57 (NB) | FAP 824(US 45) | NEOGA INTERCHANGE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 49.5 | 137.5 | Poor | 46.8 | 018000400000000 |
NBI report | I-57 (SB) | FAP 824 (US-45) | NEOGA INTERCHANGE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 49.5 | 137.5 | Poor | 64.5 | 018000300000000 |
NBI report | I-57 (NB) | BUSH CREEK | .7 MI S COLES CO LIN | Concrete Tee beam (3 spans) | -- | 1964 | -- | 45.6 | 120.4 | Fair | 85.5 | 018000600000000 |
NBI report | I-57 (SB) | BUSH CREEK | .7 MI S COLES CO LIN | Concrete Tee beam (3 spans) | -- | 1964 | -- | 45.6 | 120.4 | Fair | 85.5 | 018000500000000 |
NBI report | TR 10 | I-57 | 1 MI S OF NEOGA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 76.1 | 250.7 | Good | 94.1 | 018003200000000 |
NBI report | TR 27 | I-57 | 1 MI S COLES CO LINE | Concrete Tee beam (4 spans) | -- | 1964 | -- | 71.9 | 236.9 | Fair | 98.0 | 018003300000000 |
NBI report | TR 39 | I-57 | 2 MI S COLES CO LINE | Concrete Tee beam (4 spans) | -- | 1964 | -- | 71.5 | 237.2 | Fair | 92.5 | 018003400000000 |
NBI report | I-57 (NB) | Eastern Illinois RR | .3 MI S NEOGA INT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1987 | 113.2 | 292.0 | Poor | 62.4 | 018000200000000 |
NBI report | I-57 (SB) | Eastern Illinois RR | .3 MI S NEOGA INT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1987 | 113.2 | 292.0 | Poor | 62.4 | 018000100000000 |
NBI report | TR 33 B | OPOSSUM CREEK | 2.0 MI SE DIONA | Steel Culvert (2 spans) | -- | 1965 | -- | 16.7 | 46.6 | Fair | 88.5 | 018309700000000 |
NBI report | TR 134 | I-70 | .5 MI NW JEWETT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 71.2 | 235.9 | Good | 95.0 | 018003600000000 |
NBI report | TR 134 | COTTONWOOD CREEK | .5 MI W JEWETT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 64.3 | 179.1 | Good | 95.5 | 018309900000000 |
NBI report | CH 24 | I-70 | 1 MI NE OF JEWETT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 73.2 | 232.0 | Good | 92.4 | 018003100000000 |
NBI report | FAS 701(CH 6) | I-70 | N EDGE OF JEWETT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 71.2 | 229.0 | Fair | 82.7 | 018001700000000 |
NBI report | TR 68 | I-70 | 1.4MI NE EFF CO LINE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 71.5 | 231.3 | Fair | 94.9 | 018003500000000 |
NBI report | I-70 (EB) | MUDDY CREEK | 4.6MI E EFF CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2002 | 64.0 | 196.5 | Fair | 96.0 | 018004300000000 |
NBI report | I-70 (EB) | COTTONWOOD CREEK | 6.5MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2002 | 65.0 | 176.8 | Fair | 98.0 | 018005400000000 |
NBI report | I-70 (WB) | MUDDY CREEK | 4.6MI E EFF CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2002 | 64.0 | 196.5 | Fair | 96.0 | 018004200000000 |
NBI report | I-70 (WB) | COTTONWOOD CREEK | 6.5MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2002 | 65.0 | 176.8 | Fair | 87.0 | 018004400000000 |
NBI report | FAS 676(CH 17) | I-70 | 4 MI E GREENUP | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 73.2 | 233.9 | Good | 95.4 | 018001600000000 |
NBI report | I-70 | CROOKED CREEK | MP 111.2 | Concrete Culvert (3 spans) | -- | 1969 | -- | 11.5 | 38.7 | Fair | 82.0 | 018200100000000 |
NBI report | I-70 (EB) | FAS 1657 | 4.4MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 38.1 | 101.1 | Good | 95.0 | 018004000000000 |
NBI report | I-70 (EB) | IL 121 (FAP 773) | I-70 OVER IL 121 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 50.9 | 138.5 | Fair | 95.0 | 018004800000000 |
NBI report | I-70 (EB) | EMBARRAS RIVER | 12 MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1969 | -- | 92.9 | 670.0 | Fair | 77.7 | 018005000000000 |
NBI report | I-70 (WB) | FAS 1657 | 4.4MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 38.1 | 101.1 | Good | 95.0 | 018004100000000 |
NBI report | I-70 (WB) | IL 121 (FAP 773) | I-70 OVER IL 121 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 50.9 | 138.5 | Fair | 96.0 | 018004700000000 |
NBI report | I-70 (WB) | EMBARRAS RIVER | 12 MI E EFF CO LINE | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1969 | -- | 92.9 | 670.0 | Fair | 77.7 | 018004900000000 |
NBI report | IL 130 (FAP 116) | I-70 | GREENUP INT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 72.5 | 237.9 | Fair | 84.2 | 018002500000000 |
NBI report | TR 240 A | I-70 | 2 MI NE OF GREENUP | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 72.8 | 237.5 | Good | 89.4 | 018003800000000 |
NBI report | TR 268 | I-70 | 2.5 MI W CLARK CO LI | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 73.2 | 233.9 | Good | 98.0 | 018003900000000 |
NBI report | TR 7 B | CLEAR CREEK | .25 MI E OF TRILLA | Prestressed Box beam or girders - Multiple | -- | 1969 | -- | 23.0 | 29.9 | Good | 93.9 | 018302600000000 |
NBI report | TR 288 | I-70 | 1 MI W CLARK CO LINE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1970 | -- | 69.9 | 227.7 | Good | 94.8 | 018005300000000 |
NBI report | TR 33 A | TRIB EMBARRAS RIVER | 1.5 MI SW OF DIONA | Steel Stringer/Multi-beam or girder | -- | 1970 | -- | 30.8 | 32.2 | Poor | 22.9 | 018303900000000 |
NBI report | I-70 (EB) | RANGE CREEK | I-70 OVER RANGE CK | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 2002 | 47.9 | 134.8 | Fair | 97.0 | 018005200000000 |
NBI report | I-70 (WB) | RANGE CREEK | I-70 OVER RANGE CR | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 2002 | 47.9 | 134.8 | Fair | 97.0 | 018005100000000 |
NBI report | TR 175 | RANGE CREEK | 3 MI SE GREENUP | Concrete Channel beam (3 spans) | -- | 1974 | -- | 40.0 | 82.0 | Fair | 83.5 | 018306700000000 |
NBI report | TR 34 | LONG POINT CREEK | 3.5 MI SE NEOGA | Concrete Channel beam | -- | 1974 | -- | 35.1 | 38.1 | Fair | 86.6 | 018309800000000 |
NBI report | CH 9(FAS 655) | CLEAR CREEK | 5. MI SE JANESVILLE | Concrete Channel beam (3 spans) | -- | 1975 | -- | 32.2 | 96.1 | Good | 93.8 | 018300300000000 |
NBI report | TR 7 A | OPOSSUM CREEK | 1.4 E IL 130 ON CO L | Concrete Channel beam | -- | 1975 | -- | 36.1 | 41.0 | Fair | 65.3 | 018302500000000 |
NBI report | FAS 654(CH 11) | RANGE CREEK | 2.5 MI E GREENUP | Concrete Culvert (3 spans) | -- | 1977 | -- | 18.4 | 53.8 | Good | 97.9 | 018310100000000 |
NBI report | TR 33 B | HURRICANE CREEK | 2.5 MI NW UNION CT | Prestressed Box beam or girders - Multiple | -- | 1977 | -- | 78.7 | 79.4 | Good | 97.0 | 018312600000000 |
NBI report | TR 59 | MUDDY CREEK | 3.5 MI NW TOLEDO | Prestressed Box beam or girders - Multiple | -- | 1977 | -- | 70.9 | 74.5 | Good | 97.0 | 018312700000000 |
NBI report | FAS 654(CH 11) | CHIVLER CREEK | 5.5 MI E GREENUP | Concrete Channel beam | -- | 1978 | -- | 25.9 | 29.9 | Good | 96.9 | 018310200000000 |
NBI report | TR 268 | BIRCH CREEK | 1 MI SE VEVAY PARK | Concrete Channel beam | -- | 1978 | -- | 34.1 | 36.1 | Fair | 98.0 | 018313000000000 |
NBI report | TR 52 | LONG POINT CREEK | 6 MI W TOLEDO | Concrete Channel beam | -- | 1978 | -- | 36.1 | 38.1 | Good | 97.0 | 018312900000000 |
NBI report | TR 80 | CLEAR CREEK | 0.7 MI SE TRILLA | Concrete Channel beam | -- | 1978 | -- | 35.1 | 38.1 | Good | 99.0 | 018313400000000 |
NBI report | FAS 655(CH 9) | COTTONWOOD CREEK | 2 MI S OF JANESVILLE | Prestressed Box beam or girders - Multiple | -- | 1979 | -- | 54.1 | 55.1 | Good | 95.9 | 018310400000000 |
NBI report | TR 116 | MUDDY CREEK | S EDGE JOHNSTOWN | Prestressed Box beam or girders - Multiple | -- | 1979 | -- | 74.2 | 75.1 | Good | 99.0 | 018313200000000 |
NBI report | TR 181 | SPRING POINT CREEK | 2.0 MI SW ROSYLN | Prestressed Box beam or girders - Multiple | -- | 1979 | -- | 44.0 | 45.9 | Good | 98.0 | 018312800000000 |
NBI report | TR 183 | CROOKED CREEK | 1 MI NW OF JEWETT | Concrete Channel beam | -- | 1979 | -- | 30.8 | 32.2 | Good | 98.0 | 018313100000000 |
NBI report | TR 215 | STREAM | 2.8 MI SW HAZEL DELL | Concrete Channel beam | -- | 1979 | -- | 28.9 | 32.2 | Good | 98.0 | 018314100000000 |
NBI report | TR 41 A | LOST CREEK | 2.6 MI NE UNION CTR | Concrete Channel beam | -- | 1979 | -- | 23.6 | 26.9 | Good | 98.0 | 018313300000000 |
NBI report | TR 82 | SPRING POINT CREEK | 4.5 MI W JEWETT | Prestressed Box beam or girders - Multiple | -- | 1979 | -- | 62.0 | 64.0 | Good | 97.0 | 018313600000000 |
NBI report | FAS 662 | COTTONWOOD CREEK | 1.0 MI E BRADBURY | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 60.0 | 62.0 | Good | 94.0 | 018314400000000 |
NBI report | TR 187 | RANGE CREEK | 3.0 MI SE GREENUP | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 69.6 | 71.9 | Good | 98.0 | 018313900000000 |
NBI report | TR 248 A | TRIB HURRICANE CREEK | 1.0 MI W UNION CENTE | Concrete Channel beam | -- | 1980 | -- | 34.1 | 36.1 | Good | 97.0 | 018314200000000 |
NBI report | TR 27 | BUSH CREEK | 3.5 MI NE NEOGA | Concrete Channel beam | -- | 1980 | -- | 38.1 | 40.0 | Good | 98.0 | 018313500000000 |
NBI report | TR 64 | MULE CREEK | 2.5 MI NE ROSLYN | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 60.0 | 63.0 | Good | 96.0 | 018314500000000 |
NBI report | FAP 828 | BRUSH CREEK | 1.5 MI S IL 121 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1981 | -- | 24.9 | 74.2 | Poor | 65.7 | 018005600000000 |
NBI report | FAP 828 | SPRING POINT CREEK | .5 MI N EFFHAM LINE | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1981 | -- | 37.1 | 108.9 | Fair | 86.1 | 018005700000000 |
NBI report | FAS 701(CH 6) | COTTONWOOD CREEK | 1.0 MI N OF JEWETT | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1981 | -- | 55.1 | 127.0 | Good | 96.0 | 018310300000000 |
NBI report | TR 215 | CROOKED CREEK | 1.3 MI SW HAZEL DELL | Concrete Channel beam | -- | 1981 | -- | 36.1 | 38.1 | Good | 98.0 | 018314000000000 |
NBI report | FAP 116(IL 130) | HURRICANE CREEK | 4.8 MI S OF COLES CO | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1982 | -- | 86.0 | 339.9 | Fair | 78.7 | 018005800000000 |
NBI report | TR 100 A | WEBSTER BRANCH | 3.0 MI SW JEWETT | Concrete Channel beam | -- | 1982 | -- | 35.1 | 36.1 | Good | 97.0 | 018313700000000 |
NBI report | TR 268 | LOST CREEK | 1.4 SE UNION CENTER | Concrete Channel beam | -- | 1982 | -- | 35.1 | 37.4 | Good | 98.0 | 018314300000000 |
NBI report | TR 31 | DICKS CREEK | SE CORNER JOHNSTOWN | Concrete Channel beam | -- | 1982 | -- | 29.9 | 32.2 | Good | 97.0 | 018313800000000 |
NBI report | FAS 676(CH 17) | LOST CREEK | 1.3 MI S UNION CENTE | Concrete Channel beam | -- | 1983 | -- | 34.1 | 35.8 | Good | 99.0 | 018315100000000 |
NBI report | TR 110(FAS 2655) | BEAR CREEK | 3.0 MI NW TOLEDO | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 5.2 | 57.1 | Good | 98.0 | 018315000000000 |
NBI report | TR 203 | SPRING POINT CREEK | 2.8 MI NW MONTROSE | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 44.0 | 44.9 | Good | 97.0 | 018314900000000 |
NBI report | TR 258 | RANGE CREEK | 4 MI E OF GREENUP | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 69.9 | 69.9 | Good | 99.0 | 018315300000000 |
NBI report | TR 54 | BUCK BRANCH | 5 MI SE OF NEOGA | Concrete Channel beam | -- | 1983 | -- | 24.0 | 24.0 | Fair | 97.0 | 018315400000000 |
NBI report | TR 77 | BEAR CREEK | 4.0 MI NW TOLEDO | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 54.1 | 57.1 | Good | 97.0 | 018314600000000 |
NBI report | TR 177 (FAS 1657) | MUDDY CREEK | 2 MI EAST OF ROSLYN | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1985 | -- | 80.1 | 167.0 | Good | 96.9 | 018315800000000 |
NBI report | TR 20 | SPRING POINT CREEK | 2.5 MI NW ROSLYN | Prestressed Box beam or girders - Multiple | -- | 1985 | -- | 66.9 | 68.9 | Good | 97.0 | 018315700000000 |
NBI report | TR 268 | HURRICANE CREEK | 3.6 MI NE UNION CTR | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 59.1 | 60.0 | Good | 98.0 | 018315600000000 |
NBI report | TR 53 | RANGE CREEK | 3.4 MI E UNION CTR | Concrete Channel beam | -- | 1986 | -- | 37.1 | 42.0 | Fair | 98.0 | 018315500000000 |
NBI report | TR 205 | SPRING POINT CREEK | 3.1 MI W OF WOODBURY | Concrete Channel beam | -- | 1987 | -- | 34.1 | 38.1 | Good | 98.0 | 018315900000000 |
NBI report | TR 266 | BIRCH CREEK | 1 MI S VEVAY PARK | Concrete Channel beam | -- | 1987 | -- | 38.1 | 41.0 | Good | 98.0 | 018315200000000 |
NBI report | FAS 1676(TR 31) | COTTONWOOD CREEK | 1.5 MI S LIN LOG PK | Concrete Culvert (2 spans) | -- | 1988 | -- | 12.1 | 25.9 | Good | 77.9 | 018500800000000 |
NBI report | FAS 662 | BR COTTONWOOD CREEK | 3 MI N OF TOLEDO | Concrete Culvert (2 spans) | -- | 1988 | -- | 15.7 | 34.1 | Good | 82.9 | 018500700000000 |
NBI report | FAS 676(CH 17) | HURRICANE CREEK TRIB | .4 MI N UNION CENTER | Concrete Culvert (2 spans) | -- | 1988 | -- | 9.8 | 22.0 | Good | 97.0 | 018501000000000 |
NBI report | TR 234 | HURRICANE CREEK TRIB | 2 MI W UNION CENTER | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 60.0 | 63.0 | Good | 98.0 | 018316700000000 |
NBI report | TR 294 | BIRCH CREEK | 2 MI SW OF CASEY | Concrete Culvert (2 spans) | -- | 1988 | -- | 12.8 | 26.9 | Good | 85.5 | 018500900000000 |
NBI report | TR 15 | CLEAR CREEK | 1.5 MI SE OF TRILLA | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1989 | -- | 42.0 | 93.8 | Good | 98.0 | 018316400000000 |
NBI report | TR 226 A | STREAM | 2 MI NE OF GREENUP | Concrete Culvert (2 spans) | -- | 1989 | -- | 12.1 | 26.2 | Good | 97.0 | 018501100000000 |
NBI report | TR 256 | LOST CREEK | 2.5 MI SW UNION CTR | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1989 | -- | 23.6 | 76.4 | Good | 98.0 | 018316600000000 |
NBI report | TR 268 | CHIVLER CREEK | 6 MI E OF GREENUP | Concrete Culvert (2 spans) | -- | 1989 | -- | 12.1 | 26.6 | Good | 85.5 | 018501200000000 |
NBI report | TR 129 | COTTONWOOD CREEK | .5 MI NE TOLEDO | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1990 | -- | 35.1 | 86.6 | Good | 98.0 | 018316300000000 |
NBI report | TR 219 | SPRING POINT CREEK | 4 MI WNW MONTROSE | Concrete Slab (3 spans) | -- | 1990 | -- | 28.9 | 77.8 | Good | 97.0 | 018316500000000 |
NBI report | TR 19 | DARKIES CREEK | .5 MI W JOHNSTOWN | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 59.1 | 61.4 | Good | 98.0 | 018316200000000 |
NBI report | TR 31 | COTTONWOOD CREEK | 2.5 MI SE JANESVILLE | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 59.1 | 61.4 | Good | 98.0 | 018316100000000 |
NBI report | TR 215 | PANTHER CREEK | 3 MI SE HAZEL DELL | Concrete Slab | -- | 1992 | -- | 34.1 | 36.1 | Good | 98.0 | 018317000000000 |
NBI report | FAP 116(IL 130) | HURRICANE CREEK | 3.5 MI N OF I-70 | Concrete Culvert (3 spans) | -- | 1993 | -- | 14.1 | 45.3 | Good | 96.4 | 018200500000000 |
NBI report | TR 65 | LOST CREEK | 1.5 MI SE UNION CTR | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 58.1 | 61.4 | Good | 98.0 | 018316800000000 |
NBI report | TR 15 | MUDDY CREEK | 1.5 MI W JOHNSTOWN | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 63.3 | 65.9 | Good | 98.0 | 018317400000000 |
NBI report | TR 15 | CLEAR CREEK | 1.5 MI W JOHNSTOWN | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 66.9 | 69.6 | Good | 98.0 | 018317500000000 |
NBI report | TR 280 A | BIRCH CREEK | 1.6 MI SE VEVAY PARK | Concrete Slab | -- | 1994 | -- | 26.9 | 29.9 | Good | 96.9 | 018317100000000 |
NBI report | FAS 1656(CH 7) | SPRING POINT CREEK | 2 MI W OF ROSLYN | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1995 | -- | 24.9 | 76.4 | Good | 96.9 | 018317800000000 |
NBI report | FAS 655 | EMBARRAS RIVER | 4 MI SE JANESVILLE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1995 | -- | 149.9 | 355.3 | Good | 99.7 | 018317200000000 |
NBI report | TR 135 | COTTONWOOD CREEK | .2 MI E OF TOLEDO | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1995 | -- | 40.0 | 111.6 | Good | 99.9 | 018318000000000 |
NBI report | FAS 655 | EMBARRAS R OVERFLOW | 10 MI S CHARLESTON | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 60.0 | 61.4 | Good | 99.7 | 018318200000000 |
NBI report | FAS 700 | LOST CREEK | 1.5 MI E UNION CENTE | Concrete Culvert (2 spans) | -- | 1997 | -- | 12.5 | 27.6 | Good | 97.0 | 018501500000000 |
NBI report | TR 149 | BUSH CREEK | 6.5 MI SE OF NEOGA | Concrete Culvert (2 spans) | -- | 1997 | -- | 13.8 | 29.9 | Good | 100.0 | 018501400000000 |
NBI report | TR 173 | COTTONWOOD CREEK | 2.3 MI SW OF TOLEDO | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 60.0 | 61.4 | Good | 98.0 | 018318500000000 |
NBI report | TR 290 | RANGE CREEK | 3.5 MI NW OF CASEY | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1998 | -- | 24.9 | 76.4 | Good | 98.0 | 018316900000000 |
NBI report | TR 270 | CROOKED CREEK TRIB | .5 MI W HAZEL DELL | Concrete Culvert (2 spans) | -- | 1999 | -- | 12.5 | 27.6 | Good | 97.0 | 018501600000000 |
NBI report | FAP 828(IL 121) | STREAM | 3 MI S OF US-45 | Steel Stringer/Multi-beam or girder | -- | 2000 | -- | 44.3 | 46.9 | Good | 96.0 | 018006000000000 |
NBI report Bridgehunter | FAS 657 | EMBARRAS RIVER | .8 MI W OF GREENUP | Wood Truss - Thru | -- | 2000 | -- | 193.9 | 206.0 | Good | 74.0 | 018318300000000 |
NBI report | FAS 702 | BR OF CROOKED CREEK | .3 MI N HAZEL DELL | Prestressed Box beam or girders - Multiple | -- | 2000 | -- | 67.3 | 70.9 | Good | 98.9 | 018318100000000 |
NBI report | FAS 700 | STREAM | .5 MI W OF UNION CTR | Concrete Culvert (2 spans) | -- | 2001 | -- | 12.1 | 26.6 | Good | 96.9 | 018501800000000 |
NBI report | TR 272 | STREAM | 1.5 MI S HAZEL DELL | Concrete Culvert (2 spans) | -- | 2001 | -- | 11.2 | 22.6 | Good | 85.5 | 018501700000000 |
NBI report | TR 66 | SPRING POINT CREEK | 3.5 MI NE MONTROSE | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2001 | -- | 49.9 | 153.6 | Good | 98.0 | 018318700000000 |
NBI report | TR 189 | Spring Point Creek | T9N R7E Sec 22 | Prestressed Box beam or girders - Multiple | -- | 2002 | -- | 47.9 | 49.9 | Good | 98.0 | 018318800000000 |
NBI report | TR 268 | RANGE CREEK | 3.6 MI SE UNION CENT | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2002 | -- | 24.9 | 76.4 | Good | 98.0 | 018319000000000 |
NBI report | TR 91 | LOST CREEK | 3.0 SW UNION CENTER | Prestressed Box beam or girders - Multiple | -- | 2004 | -- | 76.1 | 77.4 | Fair | 99.0 | 018318900000000 |
NBI report | FAS 655 | MUDDY CREEK | 2 MI S OF JANESVILLE | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2005 | -- | 60.0 | 124.0 | Good | 99.9 | 018318600000000 |
NBI report | TR 89 | MULE CREEK | 5 MI SE NEOGA | Prestressed Box beam or girders - Multiple | -- | 2006 | -- | 71.5 | 76.4 | Good | 98.0 | 018319200000000 |
NBI report | TR 266 | CROOKED CREEK TRIB | 1.4 MI NW HAZEL DELL | Prestressed Box beam or girders - Multiple | -- | 2007 | -- | 42.3 | 47.2 | Good | 100.0 | 018319500000000 |
NBI report | TR 89 B | COTTONWOOD CREEK | 3 MI NE OF TOLEDO | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2007 | -- | 39.4 | 116.5 | Good | 100.0 | 018319300000000 |
NBI report | TR 280 | RANGE CREEK | 2.5 MI SE UNION CENT | Prestressed Box beam or girders - Multiple | -- | 2008 | -- | 59.4 | 61.4 | Good | 98.0 | 018319600000000 |
NBI report | FAS 662 | EMBARRAS RIVER | 4.5 MI N GREENUP | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2009 | -- | 60.7 | 185.0 | Good | 99.8 | 018319400000000 |
NBI report | FAS 662 | EMBARRAS RIVER | 5 MI NE GREENUP | Concrete Slab (3 spans) | -- | 2009 | -- | 180.1 | 449.5 | Good | 99.9 | 018319100000000 |
NBI report | FAP 116 (IL 130) | LOST CREEK | 7 MI S COLES CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 65.0 | 187.0 | Good | 97.9 | 018006400000000 |
NBI report | IL 121 (FAP 773) | MULE CREEK | 1.7 MI E MONTROSE RD | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2010 | -- | 79.1 | 137.1 | Good | 98.6 | 018006200000000 |
NBI report | IL 121 (FAP 773) | BIG MUDDY CREEK | 2 MI W OF TOLEDO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 78.1 | 191.9 | Good | 98.7 | 018006300000000 |
NBI report | TR 15 | CLEAR CREEK | 2 MI SE TRILLA | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 63.0 | 63.0 | Fair | 100.0 | 018319700000000 |
NBI report | FAS 1676 | COTTONWOOD CR TRIB | 1.6 MI E TOLEDO | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | -- | 59.4 | Good | 89.9 | 018320100000000 |
NBI report | TR 135 | COTTONWOOD CR TRIB | 1.6 MI E TOLEDO | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 48.6 | 51.5 | Good | 94.5 | 018320000000000 |
NBI report | TR 258 | Chivler Creek | 4.0 Mi. E Greenup | Concrete Box beam or girders - Multiple | -- | 2014 | -- | 58.7 | 61.4 | Good | 94.5 | 018320200000000 |
NBI report | US 40 (FAS 1707) | RANGER CREEK | .5 MI W VEVEY PARK | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2015 | -- | 103.7 | 143.4 | Good | 83.0 | 018006100000000 |
NBI report | FAP 116 (IL 130) | RANGE CREEK | .8 MI N JASPER CO LI | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2016 | -- | 104.7 | 369.1 | Good | 98.5 | 018006700000000 |
NBI report | FAP 828 (IL 121) | LONG POINT CREEK | 4.4 MI S 45 JCT | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2016 | -- | 80.7 | 150.9 | Good | 98.7 | 018006600000000 |
NBI report | TR-157 | Spring Point Creek | 2.5 W Montrose Blktp | Prestressed Box beam or girders - Multiple | -- | 2017 | -- | 46.9 | 49.5 | Good | 98.0 | 018320500000000 |
NBI report | TR-173 | Crooked Creek | 2.0 M. NW of Jewett | Metal Culvert | -- | 2017 | -- | 25.3 | 35.8 | Good | 96.0 | 018502100000000 |
NBI report | TR 120 | BEAR CREEK | 2 MI NW OF TOLEDO | Prestressed Truss - Thru | -- | 2018 | -- | 80.7 | 83.3 | -- | -- | 018320700000000 |
NBI report | TR-5 | Cottonwood Creek | 1 Mi. E Janesville | Metal Culvert | -- | 2018 | -- | 30.8 | 30.8 | Good | 97.0 | 018502000000000 |