Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | AT&SF RR (004632W) | CH 15 | CTR-24-T11NR3E | Prestressed Box beam or girders - Multiple | -- | -- | -- | 28.9 | -- | -- | -- | 048991600000000 |
NBI report | ATSF (004646E) | E MAIN ST | E MAIN GALESBURG | Steel Stringer/Multi-beam or girder | -- | -- | -- | 27.9 | -- | -- | -- | 048991200000000 |
NBI report | BN RR (062985R) | SEMINARY ST | NW-14-T11NR1E | Steel Stringer/Multi-beam or girder | -- | -- | -- | 32.2 | -- | -- | -- | 048990800000000 |
NBI report | BN RR (065617L) | TR 11 | SE-4-T13NR1E | Concrete Slab | -- | -- | -- | 20.0 | -- | -- | -- | 048991700000000 |
NBI report | BN RR (079800H) | FREMONT STREET | NE-11-T11NR1E | Concrete Slab | -- | -- | -- | 40.0 | -- | -- | -- | 048991500000000 |
NBI report | COUNTY HIGHWAY 37 | TRIB.S.HENDERSON CRK | SE-18-T12NR1E | Concrete Culvert (3 spans) | -- | -- | -- | 6.9 | 24.0 | Fair | 78.4 | 048500300000000 |
NBI report | TR 114 | POPE CREEK | SW-4-T13NR2E | Concrete Culvert (3 spans) | -- | -- | -- | 9.8 | 33.1 | Fair | 78.5 | 048500700000000 |
NBI report | TR 151 | TRIB TO CALDWELL CRE | CTR-36-T12NR4E | Concrete Other | -- | -- | -- | 24.9 | 25.9 | Fair | 63.3 | 048310600000000 |
NBI report | TR 159 | CALDWELL CREEK | NW-3-T11NR4E | Concrete Other | -- | -- | -- | 30.8 | 33.1 | Fair | 62.5 | 048310900000000 |
NBI report | TR 172 | TRIB TO SPOON RIVER | N. CTR-36-T9NR2E | Concrete Culvert (2 spans) | -- | -- | -- | 9.8 | 23.3 | Fair | 67.3 | 048501200000000 |
NBI report | TR 192 | WALNUT CR | SW-7-T13NR3E | Concrete Culvert (2 spans) | -- | -- | -- | 9.8 | 22.0 | Good | 77.3 | 048501300000000 |
NBI report Bridgehunter | TR 254 | WALNUT CREEK | SE-23-T13NR3E | Steel Truss - Thru | -- | -- | -- | 69.9 | 74.2 | Poor | 22.0 | 048315200000000 |
NBI report | TR 263 | TRIB TO SPOON RIVER | NW-21-T10NR3E | Concrete Slab | -- | -- | -- | 24.9 | 25.9 | Fair | 64.3 | 048315800000000 |
NBI report | TR 273 | PIG CREEK | NE-28-T10NR2E | Concrete Culvert (2 spans) | -- | -- | -- | 9.8 | 23.0 | Fair | 67.3 | 048501700000000 |
NBI report | TR 323 | INDIAN CREEK | SW-10-T9NR1E | Concrete Other | -- | -- | -- | 23.0 | 24.0 | Fair | 65.0 | 048318500000000 |
NBI report | TR 57 | TRIB TO WALNUT CREEK | NW-34-T13NR4E | Steel Stringer/Multi-beam or girder | -- | -- | -- | 26.9 | 28.2 | Poor | 58.6 | 048307700000000 |
NBI report | TR 194 | LITTLERS CREEK | NE-30-T9NR3E | Prestressed Box beam or girders - Multiple | -- | -- | 1973 | 49.9 | 50.9 | Good | 89.8 | 048312500000000 |
NBI report | TR 210 | WALNUT CREEK | N1/2-17-T13NR3E | Prestressed Box beam or girders - Multiple | -- | -- | 1973 | 38.1 | 39.0 | Fair | 81.7 | 048313100000000 |
NBI report | TR 51 | FOREMAN CREEK | NW-35-T13NRS3E | Prestressed Box beam or girders - Multiple | -- | -- | 1978 | 35.1 | 36.1 | Fair | 88.5 | 048307200000000 |
NBI report Bridgehunter | TR 206 | FOREMAN CREEK | S.CTR-5-T12NR3E | Steel Stringer/Multi-beam or girder | -- | -- | 1993 | 22.3 | 24.0 | Fair | 75.0 | 048312800000000 |
NBI report | HENDERSON ST | CEDAR CR DR DIT | 1 BLK S MAIN ST | Prestressed Box beam or girders - Multiple (2 spans) | -- | -- | 2010 | 33.5 | 68.9 | Good | 79.3 | 048002400000000 |
NBI report | BN RR (062996D) | NORTH ST | ON NORTH W.- LINCOLN | Steel Stringer/Multi-beam or girder | -- | 1888 | -- | 32.2 | -- | -- | -- | 048602100000000 |
NBI report | BN(079211T) | ILL 41 | SE-20-T11NR1E | Concrete Girder and floorbeam system | -- | 1903 | -- | 47.9 | -- | -- | -- | 048990400000000 |
NBI report | AT&SF RR (004628G) | TR 284 | SW-21-T11NR4E | Steel Stringer/Multi-beam or girder | -- | 1910 | -- | 24.9 | -- | -- | -- | 048992000000000 |
NBI report | BN(097988K) | ILL 78 | SE-12-T9NR4E | Concrete Slab | -- | 1919 | -- | 24.0 | -- | -- | -- | 048990200000000 |
NBI report | US 34 | WALNUT CREEK | 1 MI SW OF ALTONA | Prestressed Box beam or girders - Multiple | -- | 1921 | 1980 | 42.0 | 43.0 | Fair | 83.8 | 048003800000000 |
NBI report | CH 29 | TRIB TO LITTLERS CRK | NW-36-T9NR2E | Prestressed Box beam or girders - Multiple | -- | 1921 | 1982 | 26.9 | 38.1 | Good | 98.0 | 048304100000000 |
NBI report | BN(079789K) | ILL 167 (WATAGA) | NE-16-T12NR2E | Concrete Slab | -- | 1924 | -- | 24.9 | -- | -- | -- | 048991300000000 |
NBI report | LOSEY ST. GALESBUR | CEDAR CREEK | 1100 BLK E. LOSEY | Concrete Culvert (2 spans) | -- | 1925 | -- | 9.8 | 28.2 | Fair | 100.0 | 048600300000000 |
NBI report | ILL 78 | KICKAPOO CREEK | 1 MI S ILL 78&8 JCT | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1925 | 1977 | 33.1 | 104.0 | Poor | 59.6 | 048001800000000 |
NBI report | ILL 8 | HICKORY CREEK | 2 MI SE OF MAQUON | Prestressed Box beam or girders - Multiple | -- | 1926 | 1972 | 51.8 | 53.2 | Poor | 59.4 | 048001700000000 |
NBI report | BN RR (072662X) | ILL 8 | CTR-10-T9NR4E | Steel Girder and floorbeam system | -- | 1927 | -- | 32.2 | -- | -- | -- | 048990100000000 |
NBI report | COUNTY HIGHWAY 30 | OVER-FLOW LAKE STORY | N1/2-32-T12NR1E | Concrete Culvert (3 spans) | -- | 1928 | -- | 11.2 | 33.1 | Fair | 64.8 | 048500600000000 |
NBI report Bridgehunter | TR 116 | COURT CREEK | 1 MI E GALESBURG | Concrete Other | NR eligible | 1928 | -- | 41.3 | 43.6 | Fair | 58.5 | 048309700000000 |
NBI report | US 150 | LAKE STOREY | 1 MI N OF US 34 | Concrete Slab | -- | 1928 | 1959 | 30.8 | 33.1 | Fair | 87.5 | 048002900000000 |
NBI report Bridgehunter | DIETERICH AVE | CEDAR CREEK | N OF AT&SF RR | Concrete Tee beam (2 spans) | Closed | 1930 | -- | 38.1 | 77.1 | Poor | 34.0 | 048600800000000 |
NBI report | US 150 | SPOON RIVER | 4 MI W OF ILL 180 | Prestressed Stringer/Multi-beam or girder (11 spans) | -- | 1930 | 1980 | 70.9 | 594.2 | Poor | 55.8 | 048003100000000 |
NBI report | BROAD STREET | CEDAR CREEK CHANNEL | N.OF WATER ST. | Prestressed Box beam or girders - Multiple | -- | 1930 | 1997 | 36.1 | 39.0 | Fair | 96.0 | 048601100000000 |
NBI report | CHAMBERS ST | CEDAR CREEK | ON CHAMBER S.-GROVE | Prestressed Box beam or girders - Multiple | -- | 1930 | 2002 | 38.1 | 39.0 | Good | 97.0 | 048601900000000 |
NBI report | PRAIRIE ST | CEDAR CREEK | 200 BLK N. PRAIRIE | Prestressed Box beam or girders - Multiple | -- | 1930 | 2002 | 38.1 | 39.0 | Good | 96.0 | 048601400000000 |
NBI report | CEDAR ST | CEDAR FORK CREEK | 200 N. CEDAR | Concrete Tee beam | -- | 1931 | -- | 39.0 | 39.0 | Poor | 54.0 | 048602800000000 |
NBI report | ACADEMY ST | CEDAR CREEK | ONE BLOCK N OF MAIN | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1931 | 2001 | 23.0 | 48.6 | Good | 97.0 | 048602900000000 |
NBI report | BN (063724U) 177.6 | ILL 116 | 0.1 M WEST OF IL 41 | Steel Stringer/Multi-beam or girder | -- | 1934 | -- | 35.1 | -- | -- | -- | 048990500000000 |
NBI report | BN RR (093680D) | LOSEY ST | CTR-11-T11NR1E | Concrete Girder and floorbeam system | -- | 1934 | -- | 24.9 | -- | -- | -- | 048991000000000 |
NBI report | FAS 393-CH 4 | WALNUT CREEK | CTR-17-T13NR3E | Concrete Culvert (2 spans) | -- | 1934 | -- | 9.8 | 23.0 | Good | 89.5 | 048501100000000 |
NBI report | ATSF(004625L) | ILL 180 | @ WILLIAMSFIELD | Steel Stringer/Multi-beam or girder | -- | 1939 | -- | 34.1 | -- | -- | -- | 048991400000000 |
NBI report | AT&SF RR(004644R) | MS 6000-EE ST | NE 18-T11N,R2E | Wood Stringer/Multi-beam or girder | -- | 1950 | -- | 15.1 | -- | -- | -- | 048992200000000 |
NBI report | US 150 | POPE CR | 2 M S OF ILL 17 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1951 | -- | 50.9 | 135.5 | Poor | 66.2 | 048002600000000 |
NBI report | MCCLURE ST | CEDAR CREEK | SOUTH OF W. MAIN ST. | Concrete Tee beam | -- | 1956 | -- | 42.0 | 43.0 | Fair | 85.7 | 048600600000000 |
NBI report | COUNTY HIGHWAY 20 | SPOON RIVER | W.CTR-35-T10NR3E | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1956 | 1971 | 76.1 | 417.0 | Fair | 80.5 | 048302200000000 |
NBI report | COUNTY HIGHWAY 07 | MIDDLE CREEK | NE-4-T11NR2E | Steel Culvert (2 spans) | -- | 1956 | 1976 | 15.4 | 32.8 | Fair | 96.9 | 048500500000000 |
NBI report | FAS 394-CH 12 | LITTLE HAW CREEK | SW-8-T10NR3E | Concrete Culvert (2 spans) | -- | 1958 | -- | 12.1 | 26.9 | Good | 89.5 | 048500000000000 |
NBI report | COUNTY HIGHWAY 37 | TRIB.S.HENDERSON.CRK | SE-16-T12NR1E | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 25.9 | Fair | 85.9 | 048500400000000 |
NBI report | FAS 393 - CH 4 | WALNUT CREEK | E.CTR-17-T13NR3E | Concrete Channel beam (3 spans) | -- | 1962 | -- | 29.9 | 79.1 | Poor | 46.0 | 048300100000000 |
NBI report | FAS 395 - CH 17 | TRIB TO SPOON RIVER | SW-18-T10NR4E | Steel Culvert (2 spans) | -- | 1962 | -- | 8.9 | 26.9 | Poor | 41.3 | 048502200000000 |
NBI report | MARKET ST (MS 7350 | I-74 | IN KNOXVILLE | Concrete Tee beam (4 spans) | -- | 1962 | -- | 67.9 | 231.0 | Fair | 70.3 | 048004900000000 |
NBI report | BRICKYARD ROAD | I-74 | 1 MI NW KNOXVILLE | Concrete Tee beam (4 spans) | -- | 1963 | -- | 86.0 | 291.0 | Fair | 73.8 | 048004800000000 |
NBI report | EB I-74 | MAIN (FAU 6800) | GALESBURG INERCH | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 50.9 | 178.2 | Fair | 63.7 | 048000900000000 |
NBI report | EB I-74 | TR 205 | 1 MI W OF US 150 | Concrete Slab (3 spans) | -- | 1963 | -- | 41.0 | 111.9 | Good | 97.2 | 048001200000000 |
NBI report | WB I-74 | E. MAIN ST | GALESBURG INTERCH | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 56.1 | 187.0 | Fair | 84.1 | 048001000000000 |
NBI report | WB I-74 | TR 205 | 1 MI W JCT US 150 | Concrete Slab (3 spans) | -- | 1963 | -- | 41.0 | 111.9 | Good | 97.2 | 048001100000000 |
NBI report | EB I-74 | BNSF RR (004648T) | N.GALESBURG INTERCH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1995 | 67.9 | 172.9 | Poor | 68.9 | 048000700000000 |
NBI report | WB I-74 | BNSF RR (004648T) | N GALESBURG INTERCH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1995 | 67.9 | 178.2 | Fair | 66.8 | 048000800000000 |
NBI report | CH 7 | I-74 | 1 MI N GALESBURG INT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | 1999 | 67.6 | 231.0 | Fair | 88.1 | 048005900000000 |
NBI report | US 150 | INTERSTATE 74 | 1 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1963 | 2002 | 73.5 | 226.1 | Fair | 96.2 | 048003000000000 |
NBI report | KNOX ST | I-74 | S OF GALESBURG INTER | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 83.7 | 256.9 | Fair | 83.0 | 048005800000000 |
NBI report | BN(065601P) | US 34 BYPASS | 1.5 MI E OF US 150 | Steel Stringer/Multi-beam or girder | -- | 1965 | -- | 42.0 | -- | -- | -- | 048006600000000 |
NBI report | FAS 397 - CH 8 | HAW CREEK | NW-4-T10NR2E | Concrete Culvert (2 spans) | -- | 1965 | -- | 13.1 | 28.9 | Good | 99.7 | 048500100000000 |
NBI report | HENDERSON ROAD | I-74 | 2.5 MI W OF WATAGA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 66.9 | 223.1 | Poor | 49.7 | 048006100000000 |
NBI report | LINCOLN PARK DR | US 34 BYPASS | 0.6 MI E OF US 150 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 59.1 | 203.1 | Poor | 55.8 | 048006800000000 |
NBI report | TR 121 | I-74 | 1.5 MI N US-34 INTER | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 66.9 | 222.1 | Fair | 78.7 | 048006000000000 |
NBI report | TR 21 | I-74 | 4 MI SW OF WOODHULL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 66.9 | 223.1 | Fair | 86.1 | 048006300000000 |
NBI report | TR 304 | FRENCH CREEK | SW-34-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1965 | -- | 28.9 | 91.5 | Fair | 33.0 | 048317800000000 |
NBI report | TR 399-100N | I-74 | 1 MI SW OF WOODHULL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 66.9 | 223.1 | Fair | 82.9 | 037010500000000 |
NBI report | TR 6A,MERCER CO LI | TRIB.TO N.HENDERSON | SW-7-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 1965 | -- | 30.5 | 33.5 | Fair | 66.3 | 048305300000000 |
NBI report | TR 74 FARNHAM ST | US 34 BYPASS | W OF I-74&34 INTERCH | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 53.2 | 184.1 | Poor | 38.6 | 048006500000000 |
NBI report | TR 76 | TRIB TO HENDERSON CK | SE-26-T13NR1E | Concrete Channel beam | -- | 1965 | -- | 23.0 | 24.0 | Fair | 91.0 | 048308300000000 |
NBI report | TR 89 | I-74 | 2.5 MI S HENDERSON C | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 66.9 | 223.1 | Fair | 83.7 | 048006200000000 |
NBI report | US 34 EB | US 150 | N CL OF GALESBURG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 74.2 | 238.9 | Fair | 85.7 | 048002200000000 |
NBI report | US 34 WB | US 150 | N CL OF GALESBURG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 74.2 | 238.9 | Fair | 86.2 | 048002100000000 |
NBI report | EB US 34 | I-74 | NE OF GALESBURG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | 2010 | 86.9 | 264.1 | Fair | 90.0 | 048002000000000 |
NBI report | WB US 34 | I-74 | NE OF GALESBURG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | 2010 | 86.9 | 264.1 | Fair | 93.4 | 048001900000000 |
NBI report | AT&SF RR (004676W) | MCCLURE ST | ON MCCLURE S OF MAIN | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 32.2 | -- | -- | -- | 048600700000000 |
NBI report | ONTARIO ROAD | I-74 | .5 MI N HENDERSON CR | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 66.9 | 222.1 | Poor | 47.7 | 048003600000000 |
NBI report | RIO ROAD | I-74 | 5 MI S WOODHULL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 66.9 | 222.1 | Poor | 51.7 | 048003700000000 |
NBI report | TR 21A | TRIB TO POPE CREEK | NE-17-T13NR2E | Concrete Channel beam | -- | 1966 | -- | 23.0 | 24.0 | Fair | 90.7 | 048306100000000 |
NBI report | TR 244 | WALNUT CREEK | NE-22-T13NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1966 | -- | 49.9 | 109.9 | Poor | 37.5 | 048314200000000 |
NBI report | TR 260 | LITTLERS CREEK | W CTR-31-T9NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1966 | -- | 24.0 | 71.9 | Fair | 92.0 | 048315600000000 |
NBI report | APPLETON ROAD | I-74 | 6 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 76.1 | 248.0 | Poor | 55.6 | 048003400000000 |
NBI report | CH 21 | I-74 | 3 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 70.9 | 230.0 | Poor | 56.2 | 048004700000000 |
NBI report | EB I-74 | IL 17 & BNSF-EXEMPT | 0.5 MI W OF WOODHULL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 67.9 | 248.0 | Poor | 59.7 | 037001900000000 |
NBI report | I-74 | STREAM | .1M N KNOX CO LINE | Steel Culvert (2 spans) | -- | 1967 | -- | 9.8 | 23.0 | Poor | 53.2 | 037201000000000 |
NBI report | TR 126 | HERMON CREEK | NW-10-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1967 | -- | 36.1 | 107.9 | Fair | 56.1 | 048310100000000 |
NBI report | TR 253 | I-74 | 6 MI E SPOON RIVER | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 69.9 | 230.0 | Fair | 88.6 | 048005300000000 |
NBI report | TR 76 | HENDERSON CREEK | E.CTR-35-T13NR1E | Concrete Channel beam | -- | 1967 | -- | 35.1 | 36.1 | Fair | 81.8 | 048308400000000 |
NBI report | WB I-74 | IL 17 & BNSF-EXEMPT | 0.5 MI W OF WOODHULL | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 67.9 | 248.0 | Poor | 64.9 | 037002000000000 |
NBI report | EB I-74 | SPOON RIVER & TR238A | 9 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 108.9 | 392.1 | Poor | 61.8 | 048005200000000 |
NBI report | EB I-74 | FRENCH CR | 5 MI E SPOON RIVER | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 42.0 | 119.1 | Poor | 45.3 | 048005500000000 |
NBI report | FAI 74 | SPOON RIV TRIBUTARY | 0.6 MI E. SPOON RIV | Concrete Culvert (2 spans) | -- | 1968 | -- | 9.8 | 22.0 | Fair | 58.0 | 048200100000000 |
NBI report | FAS 396-CH 18 | I-74 | 3 MI E OF SPOON R | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 74.2 | 246.1 | Poor | 85.0 | 048003500000000 |
NBI report | TR 235 | I-74 | 8 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 75.1 | 243.1 | Fair | 96.5 | 048005000000000 |
NBI report | TR 287 | HAW CREEK | NW-36-T10NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1968 | -- | 54.1 | 101.4 | Fair | 74.2 | 048317200000000 |
NBI report | WB I-74 | SPOON R & TR 238A | 9 MI E OF KNOXVILLE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 108.9 | 392.1 | Poor | 28.8 | 048005100000000 |
NBI report | WB I-74 | FRENCH CREEK | 5 MI E SPOON RIVER | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 42.0 | 119.1 | Poor | 57.0 | 048005400000000 |
NBI report | COUNTY HIGHWAY 08 | BRUSH CREEK | NE-8-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1969 | -- | 29.9 | 89.9 | Fair | 83.4 | 048320000000000 |
NBI report | TR 171 | CALDWELL CREEK | W1/2-11-T11NR4E | Concrete Channel beam (3 spans) | -- | 1969 | -- | 24.0 | 71.9 | Fair | 79.8 | 048311600000000 |
NBI report | TR 228 | TRIB TO SPOON RIVER | N.CTR-27-T10NR3E | Concrete Channel beam | -- | 1969 | -- | 30.8 | 32.2 | Fair | 89.9 | 048313700000000 |
NBI report | TR 284A | FRENCH CREEK | W.CTR-33-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1969 | -- | 58.1 | 120.1 | Fair | 74.1 | 048317100000000 |
NBI report | OAK RUN ROAD | TRIB TO SPOON LAKE | SE-34-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 47.9 | 48.9 | Fair | 92.5 | 048328000000000 |
NBI report | OAK RUN ROAD-TR 50 | SPOON LAKE OVERFLOW | SE-11-T11NR3E | Concrete Channel beam | -- | 1970 | -- | 34.1 | 36.1 | Fair | 91.5 | 048328100000000 |
NBI report | TR 84 | POPE CREEK | SW-6-T13NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1970 | -- | 29.9 | 89.9 | Good | 76.5 | 048320100000000 |
NBI report | FREMONT ST FAU 679 | US 34 BYPASS | 1.13 M N OF IL41/164 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1971 | -- | 86.9 | 205.1 | Fair | 89.0 | 048006900000000 |
NBI report | ILL 8 | STREAM | 4.5 MI E OF ILL 97 | Concrete Culvert (2 spans) | -- | 1971 | -- | 11.2 | 24.9 | Fair | 88.0 | 048200200000000 |
NBI report | TR 220 | FOREMAN CREEK | W.CTR-4-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1971 | -- | 31.5 | 34.1 | Fair | 90.6 | 048320400000000 |
NBI report | TR 249 | HAW CREEK | S.CTR-15-T10NR2E | Concrete Channel beam (3 spans) | -- | 1971 | -- | 24.0 | 67.9 | Fair | 82.5 | 048320300000000 |
NBI report | TR 291 | SWAB RUN CREEK | SW-25-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 1971 | -- | 33.1 | 35.4 | Fair | 66.3 | 048320500000000 |
NBI report | TR 36 | S HENDERSON CREEK | SW-21-T12NR1E | Concrete Channel beam (3 spans) | -- | 1971 | -- | 25.9 | 64.0 | Fair | 88.9 | 048320200000000 |
NBI report | COUNTY HIGHWAY 08 | HERMON CREEK | S.CTR-18-T9NR2E | Steel Culvert (3 spans) | -- | 1972 | -- | 8.9 | 33.1 | Good | 99.9 | 048500800000000 |
NBI report | SEMINARY ST | US 34 BYPASS | 1 MI E OF US 150 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1972 | -- | 74.2 | 201.1 | Poor | 62.6 | 048006700000000 |
NBI report | FAS 398 - CH 20 | TRIB TO HAW CREEK | NW-1-T9NR2E | Steel Culvert (2 spans) | -- | 1973 | -- | 8.9 | 24.0 | Fair | 96.9 | 048501800000000 |
NBI report | TR 336 | WALNUT CREEK | N.CTR-1-T12NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1973 | -- | 47.9 | 102.0 | Poor | 49.5 | 048321000000000 |
NBI report | TR 52 | BRUSH CREEK | NW-13-T10NR1E | Steel Culvert (2 spans) | -- | 1973 | -- | 8.9 | 23.0 | Poor | 58.4 | 048500900000000 |
NBI report | TR 341 | KICKAPOO CREEK | SE-14-T9NR4E | Prestressed Box beam or girders - Multiple | -- | 1974 | -- | 33.1 | 36.1 | Poor | 60.6 | 048321100000000 |
NBI report | ILL 116 | CEDAR CREEK | APPR 2M W IL 41 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1975 | -- | 87.9 | 233.9 | Poor | 63.2 | 048007000000000 |
NBI report | TR 325 | HERMON CREEK | NE-17-T9NR2E | Steel Culvert (2 spans) | -- | 1975 | -- | 8.9 | 21.0 | Good | 97.0 | 048501000000000 |
NBI report | FARNHAM ST | AT&SF (004649A) | 2 BLKS N. OF MAIN ST | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1976 | -- | 45.9 | 141.1 | Poor | 30.0 | 048602700000000 |
NBI report | I74WB REST AREA RA | TRIB SPOON RIVER | SPOON RIVER RESTAREA | Concrete Culvert (2 spans) | -- | 1976 | -- | 11.5 | 26.6 | Fair | 89.0 | 048200400000000 |
NBI report | TR 171 | TRIB TO SNAKEDEN CR | NW-9-T11NR4E | Concrete Channel beam | -- | 1976 | -- | 22.0 | 24.0 | Fair | 79.0 | 048321800000000 |
NBI report | TR 31 | FITCH CREEK | W CTR-23-T13NR4E | Prestressed Box beam or girders - Multiple | -- | 1976 | -- | 39.0 | 43.0 | Fair | 85.0 | 048321500000000 |
NBI report | CO. HWY 27 | HAW CREEK | CTR-19-T10NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1976 | 1996 | 38.1 | 115.5 | Fair | 94.0 | 048321400000000 |
NBI report | US 34 EB | W MAIN ST | 0.3 MI W IL 41 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1976 | 2018 | 88.9 | 182.1 | Fair | 93.3 | 048007400000000 |
NBI report | US 34 WB | W. MAIN ST | 0.3 MI W IL 41 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1976 | 2018 | 88.9 | 182.1 | Fair | 93.3 | 048007300000000 |
NBI report | TR 238A | TRIB TO SPOON RIVER | NW-7-T10NR4E | Concrete Channel beam (3 spans) | -- | 1977 | -- | 22.0 | 67.9 | Fair | 96.0 | 048321700000000 |
NBI report | TR 260 | HICKORY CR | SW-7-T9NR4E | Concrete Channel beam (3 spans) | -- | 1977 | -- | 22.0 | 66.9 | Good | 91.0 | 048321900000000 |
NBI report | CO. HWY. 3 | TRIB TO WALNUT CREEK | SW-25-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1978 | -- | 41.0 | 42.0 | Good | 96.9 | 048322600000000 |
NBI report | TR 261 | HAW CREEK | CTR-13-T10NR2E | Prestressed Box beam or girders - Multiple | -- | 1978 | -- | 59.1 | 60.0 | Good | 98.0 | 048322900000000 |
NBI report | TR 30 | TRIB S HENDERSON CR. | SW-17-T12NR1E | Prestressed Box beam or girders - Multiple | -- | 1978 | -- | 55.1 | 56.1 | Fair | 91.5 | 048322300000000 |
NBI report | TR 79 | FOREMAN CREEK | W.CTR-3-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1978 | -- | 63.0 | 64.0 | Good | 93.0 | 048322700000000 |
NBI report | TR 80 | BRUNK CREEK | NE-25-T10NR1E | Prestressed Box beam or girders - Multiple | -- | 1978 | -- | 48.9 | 50.9 | Fair | 92.0 | 048322100000000 |
NBI report | EB US 34 | CEDAR CREEK | SW EDGE OF GALESBURG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 74.2 | 202.1 | Fair | 86.9 | 048007700000000 |
NBI report | MS #0101 | US 34 | SW GALESBURG AIRPORT | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1979 | -- | 119.1 | 294.0 | Fair | 87.0 | 048007800000000 |
NBI report | TR 32 | HENDERSON CREEK | SE-32-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 1979 | -- | 54.1 | 56.1 | Good | 98.0 | 048322200000000 |
NBI report | WB US 34 | CEDAR CREEK | SW EDGE OF GALESBURG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 86.9 | 241.2 | Fair | 86.9 | 048007600000000 |
NBI report | TR 1 CO LINE ROAD | TRIB TO POPE CREEK | NE-5-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 41.0 | 43.0 | Fair | 98.0 | 048323400000000 |
NBI report | TR 195B | MIDDLE CREEK | SE-13-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 51.8 | 53.2 | Good | 97.0 | 048322400000000 |
NBI report | TR 2 CO LINE ROAD | TRIB TO INDIAN CREEK | SW-7-T9NR1E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 43.0 | 44.9 | Good | 98.0 | 048323600000000 |
NBI report | TR 278 | TRIB TO WALNUT CREEK | NE-30-T13NR4E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 48.6 | 50.9 | Fair | 98.0 | 048323500000000 |
NBI report | TR 289 | TRIB TO FRENCH CREEK | SE-28-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 48.9 | 49.9 | Good | 97.0 | 048322500000000 |
NBI report | TR 56 | POPE CREEK | SW-2-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 69.9 | 70.9 | Good | 98.0 | 048323200000000 |
NBI report | TR 79 | TRIB TO FOREMAN CR | E1/2-3-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 49.9 | 51.8 | Good | 98.0 | 048322800000000 |
NBI report | FAS 394-CH 12 | COURT CREEK | NE 21 - T11N,R3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1982 | -- | 80.1 | 201.1 | Fair | 99.9 | 048327800000000 |
NBI report | TR 260 | FRENCH CREEK | SE-36-T10NR3E | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 74.2 | 77.1 | Good | 98.0 | 048327100000000 |
NBI report | TR 279 | PIG CREEK | S.CTR-28-T10NR2E | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 61.0 | 61.0 | Good | 98.0 | 048326900000000 |
NBI report | TR 39 | WALNUT CREEK | NW-21-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 74.2 | 76.1 | Good | 98.0 | 048323700000000 |
NBI report | TR 98 | HAW CREEK | NW-31-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 46.9 | 49.9 | Good | 87.9 | 048327000000000 |
NBI report | FAS-393(CH-4) | Trib to Walnut Creek | W.CTR-17-T13N,R4E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 52.8 | 55.4 | Good | 99.9 | 048327700000000 |
NBI report | ILL 41 | BNSF RR (063729D) | 0.5 M N.ST.AUGUSTINE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 109.9 | 292.0 | Poor | 61.4 | 048007900000000 |
NBI report | TR 154 | STREAM | W.CTR.-23-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 42.0 | 44.0 | Good | 87.9 | 048329500000000 |
NBI report | TR 187 | SUGAR CR | NE-14-T11N,R3E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 60.0 | 61.0 | Good | 98.0 | 048328400000000 |
NBI report | TR 254 | MUD RUN CREEK | NE-14-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 65.9 | 67.9 | Good | 98.0 | 048327400000000 |
NBI report | TR 259 | BRUSH CREEK | SW-24-T10NR1E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 79.1 | 81.0 | Good | 98.0 | 048327200000000 |
NBI report | TR 263 | TRIB TO SPOON RIVER | NW-24-T10NR3E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 48.9 | 51.8 | Poor | 60.2 | 048328800000000 |
NBI report | TR 263 | TRIB TO SPOON RIVER | NE-24-T10NR3E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 39.0 | 42.0 | Fair | 87.0 | 048329100000000 |
NBI report | TR 341 | SPOON RIVER | NE-26-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1983 | -- | 79.1 | 234.9 | Good | 98.0 | 048328500000000 |
NBI report | TR 6 | STREAM | NW-18-T11N,R1E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 42.0 | 43.0 | Good | 98.0 | 048328300000000 |
NBI report | TR 7 | POPE CREEK | NE-6-T13NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1983 | -- | 40.0 | 107.0 | Fair | 92.4 | 048327300000000 |
NBI report | FAS 399 - CH 26 | TRIB TO CEDAR FORK | E.CTR-7-T10NR1E | Prestressed Box beam or girders - Multiple | -- | 1984 | -- | 48.9 | 51.5 | Good | 98.8 | 048327600000000 |
NBI report | TR 112 | MIDDLE CREEK | NE-5-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 1984 | -- | 44.0 | 46.9 | Good | 98.0 | 048328700000000 |
NBI report | TR 15 | MUD RUN CREEK | NE-12-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1984 | -- | 59.1 | 62.0 | Good | 98.0 | 048329700000000 |
NBI report | TR 278 | STREAM | NW-5-T13NR4E | Prestressed Box beam or girders - Multiple | -- | 1984 | -- | 39.0 | 39.0 | Fair | 92.0 | 048329800000000 |
NBI report | CH 39 | SPOON RIVER | SW-34-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1985 | -- | 65.0 | 194.9 | Fair | 95.0 | 048327500000000 |
NBI report | CO HWY 2 | POPE CREEK TRIB. | NE-20-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1985 | -- | 39.0 | 40.0 | Good | 98.0 | 048329900000000 |
NBI report | FAU 6838-CH 10 | BNSF RR & GRAVEL RD | NW-27-T11NR1E | Steel Stringer/Multi-beam or girder (18 spans) | -- | 1985 | -- | 165.0 | 2028.6 | Poor | 62.2 | 048328600000000 |
NBI report | TR 130 | HAW CREEK | S.CTR-15-T10NR2E | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1985 | -- | 60.0 | 122.1 | Good | 97.0 | 048329200000000 |
NBI report | TR 329 | HAW CREEK | NE-13-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1985 | -- | 78.1 | 125.0 | Good | 98.0 | 048329400000000 |
NBI report | TR 56A | HENDERSON CREEK | SW-34-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 1985 | -- | 77.1 | 79.1 | Good | 98.0 | 048329600000000 |
NBI report | TR 84 | STREAM | NW-6-T12NR2E | Steel Culvert (2 spans) | -- | 1985 | -- | 8.9 | 22.0 | Good | 97.0 | 048502300000000 |
NBI report | ADMIRAL WALKWAY | LINWOOD RD-ILL. 41 | 0.84 S. OF MAIN ST | Steel Other | -- | 1986 | -- | 319.9 | -- | -- | -- | 048604900000000 |
NBI report | ILL 41 | CEDAR CREEK | 0.75 MI E OF US 34 | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 77.1 | 80.1 | Fair | 87.5 | 048331000000000 |
NBI report | TR 114 | TRIB TO POPE CREEK | NW-9-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 48.9 | 51.8 | Good | 98.0 | 048330000000000 |
NBI report | TR 215 | SPOON RIVER | CTR-24-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1986 | -- | 79.1 | 220.2 | Fair | 92.5 | 048329300000000 |
NBI report | TR 250 | HICKORY CREEK | SW-11-T9NR3E | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 48.9 | 51.8 | Good | 98.0 | 048330400000000 |
NBI report | TR 263 | SPOON RIVER | NE-23-TIONR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1986 | -- | 60.0 | 182.1 | Fair | 82.1 | 048331100000000 |
NBI report | TR 320 | WALNUT CREEK | E1/2-2-T12NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1986 | -- | 40.0 | 122.1 | Good | 98.0 | 048330100000000 |
NBI report | TR 320 | TRIB TO FITCH CR | SW-24-T13NR4E | Steel Culvert (2 spans) | -- | 1986 | -- | 8.9 | 22.0 | Fair | 97.0 | 048502600000000 |
NBI report | TR 76 | POPE CREEK | SW-1-T13NR1E RIO TWP | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 77.1 | 79.1 | Good | 98.0 | 048330300000000 |
NBI report | US 34 | CEDAR CREEK | 0.7M E OF COUNTY LN | Steel Culvert (2 spans) | -- | 1986 | -- | 14.1 | 32.2 | Fair | 70.0 | 048200300000000 |
NBI report | CH 28 | SPOON RIV | NW-15-T11NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1987 | -- | 70.9 | 212.0 | Fair | 85.0 | 048330200000000 |
NBI report | TR 359 | TRIB TO SPOON RIVER | NE-33-T9NR2E | Prestressed Box beam or girders - Multiple | -- | 1987 | -- | 48.9 | 51.5 | Good | 98.0 | 048331300000000 |
NBI report | CH 15 | WALNUT CREEK | NW-31-T13NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 60.0 | 141.4 | Good | 97.9 | 048330500000000 |
NBI report | CH 19 | FRENCH CREEK | W.CTR-32-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 49.9 | 131.6 | Good | 98.0 | 048331500000000 |
NBI report | FAS 398 - CH 20 | HAW CREEK | E.CTR-2-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 60.0 | 181.4 | Good | 99.9 | 048330600000000 |
NBI report | TR 130 | PIG CREEK | SW-34-T10NR2E | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 48.9 | 51.5 | Fair | 93.0 | 048332000000000 |
NBI report | TR 172 | LITTLERS CREEK | S1/2-25-T9NR2E | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 76.8 | 79.4 | Good | 98.0 | 048328200000000 |
NBI report | TR 305 | TRIB TO FRENCH CREEK | NW-5-T9NR4E | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 39.0 | 41.3 | Good | 92.5 | 048331700000000 |
NBI report | ILL 17 | FITCH CREEK | 2 MI W OF LAFAYETTE | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 61.4 | 66.3 | Fair | 99.0 | 048008100000000 |
NBI report | TR 240 | COURT CREEK | NE-22-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1989 | -- | 49.9 | 121.4 | Good | 98.0 | 048332500000000 |
NBI report | TR 56A | TRIB. S HENDERSON CR | NE-15-T12NR1E | Prestressed Box beam or girders - Multiple | -- | 1989 | -- | 48.9 | 51.5 | Good | 100.0 | 048332200000000 |
NBI report | FAS 1394-CH 7 | NORTH CREEK | SE-36-T12NR2E | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1990 | -- | 59.4 | 121.4 | Good | 99.7 | 048330900000000 |
NBI report | FAS 394-CH 12 | WALNUT CREEK | NE-21-T13NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1990 | -- | 49.9 | 120.4 | Fair | 100.0 | 048330700000000 |
NBI report | FAS 396-CH 18 | FRENCH CREEK | NW-27-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1990 | -- | 49.9 | 111.6 | Fair | 100.0 | 048333300000000 |
NBI report | ILL 180 | SPOON RIVER | 1 MI N WILLIAMSFIELD | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 170.9 | 433.1 | Fair | 86.8 | 048008000000000 |
NBI report | TR 152 | HAW CREEK | W1/2-14-T10NR2E | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1990 | -- | 39.4 | 81.4 | Good | 97.0 | 048332300000000 |
NBI report | TR 8 | INDIAN CREEK | CTR-18-T9NR1E | Prestressed Box beam or girders - Multiple | -- | 1990 | -- | 48.9 | 51.5 | Good | 97.0 | 048332100000000 |
NBI report | TR 94 | STREAM | SW-29-T9NR2E | Prestressed Box beam or girders - Multiple | -- | 1990 | -- | 48.9 | 51.5 | Good | 98.0 | 048332900000000 |
NBI report | BN RR (079801P) | LOSEY STREET | NE-11-T11NR1E | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 40.7 | -- | -- | -- | 048992600000000 |
NBI report | TR 161 | NORTH CREEK | SW-6-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1991 | -- | 40.0 | 101.4 | Good | 92.5 | 048332800000000 |
NBI report | CH 15 | COURT CREEK | SW-24-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1992 | -- | 60.0 | 181.4 | Good | 98.9 | 048332600000000 |
NBI report | CH 19 | TRIB. FRENCH CREEK | SW-32-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 1992 | -- | 48.9 | 51.5 | Good | 100.0 | 048333400000000 |
NBI report | FAS 1395-CH 6 | POPE CREEK | SW-5-T13NR2E | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1992 | -- | 49.5 | 90.6 | Good | 100.0 | 048333500000000 |
NBI report | STATE ST | COURT CREEK | STATE&ATSFRR | Steel Culvert (2 spans) | -- | 1992 | -- | 9.8 | 24.0 | Good | 97.0 | 048605800000000 |
NBI report | TR 253 | FRENCH CREEK | NE-14-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1992 | -- | 40.0 | 101.4 | Fair | 94.5 | 048333100000000 |
NBI report | TR 324 | SWAB RUN CREEK | SW-36-T10NR4E | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1992 | -- | 39.4 | 71.5 | Good | 92.5 | 048333600000000 |
NBI report | TR 619A | COURT CREEK | NW-24-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1992 | -- | 40.0 | 101.4 | Fair | 100.0 | 048332700000000 |
NBI report | FAS 394 - CH 12 | FOREMAN CREEK | SE-4-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 76.8 | 79.4 | Good | 99.9 | 048332400000000 |
NBI report | FAS 394 - CH 12 | TRIB. COURT CREEK | SE-16-T11NR3E | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 59.1 | 62.0 | Good | 96.1 | 048333200000000 |
NBI report | ILL 180 | WALNUT CREEK | 2.5M S OF ILL 17 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 70.5 | 193.9 | Good | 99.6 | 048008200000000 |
NBI report | TR 267 | FRENCH CREEK | SE-22-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 59.1 | 61.4 | Good | 98.0 | 048333900000000 |
NBI report | TR 318 | FRENCH CREEK | SE-35-T11NR4E | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 48.9 | 51.5 | Good | 92.5 | 048331600000000 |
NBI report | CH 16 | TRIB TO WALNUT CREEK | E.CTR-29-T13NR4E | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 78.1 | 79.7 | Good | 97.0 | 048333800000000 |
NBI report | F-F STREET | COURT CREEK | 0.02 S. OF E-E ST. | Steel Culvert (2 spans) | -- | 1994 | -- | 9.2 | 22.6 | Good | 97.0 | 048605600000000 |
NBI report | FAS 401 - CH 25 | TRIB TO BRUSH CREEK | E.CTR-3-T10NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1994 | -- | 24.9 | 76.4 | Good | 91.3 | 048334200000000 |
NBI report | FAS 403-CH 35 | TRIB TO HENDERSON CR | NW-35-T13NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1994 | -- | 29.9 | 91.5 | Fair | 100.0 | 048331400000000 |
NBI report | TR 192A | FOREMAN CREEK | S1/2-6-T12NR3E | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 77.1 | 79.4 | Good | 92.5 | 048333000000000 |
NBI report | TR 83 | HENDERSON CREEK | NE-7-T12NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1994 | -- | 49.9 | 111.6 | Good | 98.0 | 048333700000000 |
NBI report | CO. LINE RD. | CEDAR CREEK | NW-19-T11NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1995 | -- | 29.9 | 88.9 | Fair | 89.0 | 048600400000000 |
NBI report | TR 1 | STREAM | NE-1-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 49.9 | 54.1 | Good | 98.0 | 048334800000000 |
NBI report | TR 166 | COURT CREEK | SW-24-T11NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1995 | -- | 49.9 | 111.6 | Good | 98.0 | 048334900000000 |
NBI report | TR 175 | MIDDLE CREEK | E1/2-11-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 77.8 | 79.4 | Good | 92.5 | 048331900000000 |
NBI report | TR 192 | STREAM | S1/2-19-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 48.9 | 51.5 | Good | 98.0 | 048335000000000 |
NBI report | TR 6CO LINE RD | SOUTHHENDERSON CREEK | NW-19-T12NR1E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 59.1 | 61.4 | Good | 100.0 | 048335400000000 |
NBI report | 1ST ST | BN RR (072645G) | CTR-33-T10NR1E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 61.4 | 155.2 | Good | 98.0 | 048605900000000 |
NBI report | EAST MARTIN ST | BN RR (072643T) | N. CTR-4-T9NR1E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 61.7 | 153.6 | Good | 94.0 | 048606100000000 |
NBI report | FAS 396 | SWAB RUN CREEK | SW-35-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1996 | -- | 29.9 | 108.9 | Fair | 100.0 | 048334600000000 |
NBI report | TR 136 | MIDDLE CREEK | R2E-4THPM-SEC 3 | Prestressed Box beam or girders - Multiple | -- | 1996 | -- | 56.4 | 61.7 | Good | 98.0 | 048335900000000 |
NBI report | TR 171 | TRIB TO SPOON RIVER | NE-12-T11NR3E | Steel Culvert (2 spans) | -- | 1996 | -- | 8.9 | 20.3 | Good | 100.0 | 048502900000000 |
NBI report | TR 21A | STREAM | NW1/4SEC15R2ET13N | Steel Culvert | -- | 1996 | -- | 25.3 | 25.3 | Good | 97.0 | 048502700000000 |
NBI report | TR 338 | FRENCH CREEK | SE-1-T10NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1996 | -- | 35.1 | 96.5 | Good | 98.0 | 048335500000000 |
NBI report | CH 19 | TRIB TO FRENCH CREEK | NW-5-T9NR4E | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 49.9 | 51.5 | Good | 100.0 | 048335300000000 |
NBI report | COUNTY HIGHWAY 05 | BRUSH CREEK | NE-36-T10NR1E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1997 | -- | 29.9 | 91.9 | Good | 88.8 | 048334500000000 |
NBI report | COUNTY HIGHWAY 19 | TRIB TO FRENCH CREEK | SW-32-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 49.9 | 51.5 | Good | 100.0 | 048335200000000 |
NBI report | FAS 237 (CH 3) | TRIB. TO WALNUT CRK | SW1/4 SEC 24 T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 39.0 | 41.3 | Good | 96.9 | 048336300000000 |
NBI report | LATIMER ST | BN RR (072641E) | S1/2-33-T10NR1E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1997 | -- | 61.4 | 155.5 | Good | 97.9 | 048606000000000 |
NBI report | TR 268 | LITTLERS CREEK | NE-31-T9NR4E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1997 | -- | 40.0 | 101.4 | Good | 98.0 | 048336000000000 |
NBI report | TR 44 | INDIAN CREEK | SE-9-T9NR1E | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 78.1 | 79.7 | Good | 98.0 | 048335700000000 |
NBI report | TR 76 | TRIB TO POPE CREEK | SE1/4 SEC11 R1E T13N | Steel Culvert (2 spans) | -- | 1997 | -- | 8.9 | 23.3 | Good | 97.0 | 048502800000000 |
NBI report | COUNTY HIGHWAY 12 | TRIB TO SUGAR CREEK | S.CTR-9-T11NR3E | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 58.7 | 61.7 | Good | 91.1 | 048335100000000 |
NBI report | E. THIRD ST | BN RR (062986X) | E. OF BROAD ST | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1998 | -- | 214.9 | 799.6 | Good | 82.6 | 048601700000000 |
NBI report | FAS 393-CH 4 | MUD RUN CREEK | E.CTR-14-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 59.1 | 60.7 | Good | 99.0 | 048334700000000 |
NBI report | OAK RUN ROAD | TRIB TO SPOON LAKE | NE-4-T11NR3E | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 34.1 | 35.8 | Good | 100.0 | 048336600000000 |
NBI report | PARK ROAD | TRIB S HENDERSON CRK | NE-34-T12NR1E | Concrete Frame | -- | 1998 | -- | 24.9 | 25.9 | Good | 90.0 | 048600500000000 |
NBI report | TR 134 | STREAM | SW-3-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 48.6 | 51.5 | Good | 98.0 | 048336100000000 |
NBI report | TR 236 | FLEA CREEK | SW-23-T9NR3E | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 48.9 | 50.9 | Good | 100.0 | 048336500000000 |
NBI report | TR 15 | WALNUT CREEK | CTR-9-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 48.9 | 51.5 | Good | 98.0 | 048337100000000 |
NBI report | TR 206 | NORTH CREEK | SW-17-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1999 | -- | 40.0 | 101.4 | Good | 98.0 | 048336700000000 |
NBI report | TR 324B | KICKAPOO CREEK | SW-13-T9NR4E | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 59.1 | 61.4 | Good | 86.9 | 048336900000000 |
NBI report Bridgehunter | FAS 395-CH 17 | SPOON RIVER | 5 MI SE OF GILSON | Wood Truss - Thru | -- | 2000 | -- | 102.7 | 247.1 | Fair | 61.9 | 048336200000000 |
NBI report | IL 180 | CADWELL CR | 2 MI N WILLIAMSFIELD | Prestressed Stringer/Multi-beam or girder | -- | 2000 | -- | 78.7 | 81.0 | Good | 99.3 | 048008500000000 |
NBI report | IL 180 | CADWELL CR | 1.5 MI N WILLIAMSFLD | Prestressed Stringer/Multi-beam or girder | -- | 2000 | -- | 122.4 | 125.0 | Fair | 99.3 | 048008600000000 |
NBI report | TR 114 | TRIB TO POPE CREEK | W CTR-9-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 2000 | -- | 48.9 | 51.5 | Good | 98.0 | 048337500000000 |
NBI report | TR 289 | TRIB TO FRENCH CREEK | S.CTR-29-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 2000 | -- | 48.9 | 50.9 | Good | 98.0 | 048336800000000 |
NBI report | TR 301 | BRUSH CREEK | NE-6-T9NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2000 | -- | 88.9 | 91.5 | Good | 98.0 | 048337200000000 |
NBI report | TR 84 | TRIB HENDERSON CR | SW-30-T13NR2E | Prestressed Box beam or girders - Multiple | -- | 2000 | -- | 48.9 | 51.5 | Good | 98.0 | 048337300000000 |
NBI report | TR 236 | LITTLERS CREEK | NW-35-T9NR3E | Prestressed Box beam or girders - Multiple | -- | 2001 | -- | 39.0 | 41.3 | Good | 100.0 | 048337000000000 |
NBI report | TR 272 | STREAM | NW-29-T11NR4E | Metal Culvert | -- | 2001 | -- | 22.0 | 22.0 | Good | 98.0 | 048503000000000 |
NBI report | IL 97 | LITTLERS CREEK | 2 MI N OF RAPATEE | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 102.0 | 115.2 | Good | 98.9 | 048008300000000 |
NBI report | ILL 41 | CEDAR CREEK TRIB | 0.4 MI S JCT IL 116 | Concrete Culvert (2 spans) | -- | 2002 | -- | 11.2 | 24.3 | Fair | 94.1 | 048200600000000 |
NBI report | TR 324 B | KICKAPOO CREEK | SW-24-T9NR4E | Prestressed Box beam or girders - Multiple | -- | 2002 | -- | 72.8 | 76.8 | Good | 86.9 | 048337600000000 |
NBI report | TR 76A | S HENDERSON CREEK | E CTR-23-T12NR1E | Prestressed Box beam or girders - Multiple | -- | 2002 | -- | 39.0 | 41.3 | Good | 94.5 | 048337700000000 |
NBI report | TR 172 | TRIB TO SPOON RIVER | S1/2-36-T9NR2E | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 39.0 | 41.3 | Good | 98.0 | 048337900000000 |
NBI report | TR 217 | HAW CREEK | SW-25-T11NR1E | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 60.0 | 61.4 | Good | 98.0 | 048338200000000 |
NBI report | TR 231 | HAW CREEK | S.CTR-32-T11NR2E | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 69.2 | 71.9 | Good | 88.0 | 048338000000000 |
NBI report | US 150 | SPOON RIVER TRIB. | 3.8 MI W JCT 180/150 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 92.5 | 95.1 | Good | 97.3 | 048008400000000 |
NBI report | US 150 | S. HENDERSON CR TRIB | 3 MI N OF US 34 | Concrete Frame | -- | 2003 | -- | 21.3 | 23.0 | Good | 95.8 | 048200500000000 |
NBI report | CO.LINE RD.STARK T | FITCH CREEK | NE-13-T13NR4E | Metal Frame | -- | 2004 | -- | 25.3 | 25.3 | Good | 94.4 | 048338500000000 |
NBI report | COUNTY HIGHWAY 29 | TRIB TO LITTLERS CRK | E.CTR-31-T9NR3E | Concrete Culvert (2 spans) | -- | 2004 | -- | 14.1 | 31.2 | Good | 100.0 | 048337800000000 |
NBI report | FAP 574 (IL 41) | BNSF RR | S OF GALESBURG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 68.6 | 158.1 | Good | 97.1 | 048008700000000 |
NBI report | TR 136 | COURT CREEK | NE-22-T11NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2004 | -- | 40.0 | 91.5 | Good | 92.5 | 048338400000000 |
NBI report | TR 154 | COURT CREEK | NW-23-T11NR2E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2004 | -- | 49.9 | 111.6 | Good | 92.5 | 048338300000000 |
NBI report | CO HWY 1 | HENDERSON CREEK | SW-23.T12NR1E | Concrete Frame | -- | 2005 | -- | 32.2 | 34.1 | Good | 99.8 | 048338100000000 |
NBI report | CH 39 | TRIB TO SPOON RIVER | NE-21-T9NR2E | Concrete Culvert (2 spans) | -- | 2006 | -- | 12.1 | 26.2 | Good | 100.0 | 048334300000000 |
NBI report | TR 22 | NORTH HENDERSON CRK | NW COR-17-T13NR1E | Concrete Culvert (2 spans) | -- | 2006 | -- | 10.5 | 22.0 | Good | 100.0 | 048503400000000 |
NBI report | TR 245 | TRIB TO HAW CREEK | NW-12-T10NR2E | Prestressed Box beam or girders - Multiple | -- | 2006 | -- | 58.7 | 61.4 | Good | 100.0 | 048338600000000 |
NBI report | TR 253 | TRIB TO SPOON RIVER | SW-8-T10NR4E | Concrete Culvert (2 spans) | -- | 2006 | -- | 11.8 | 25.6 | Good | 100.0 | 048503300000000 |
NBI report | TR 320 | FITCH CREEK | NW-36-T13NR4E | Prestressed Box beam or girders - Multiple | -- | 2006 | -- | 58.7 | 61.4 | Good | 100.0 | 048339100000000 |
NBI report | CH 18 | TRIB TO SPOON RIV | N.CTR-25-T11NR4E | Concrete Culvert (2 spans) | -- | 2007 | -- | 9.8 | 22.6 | Good | 99.9 | 048503200000000 |
NBI report | TR 320 | TRIB TO WALNUT CREEK | N1/2-11-T12NR4E | Concrete Culvert (2 spans) | -- | 2007 | -- | 12.1 | 27.9 | Good | 100.0 | 048338800000000 |
NBI report | TR 171 | SNAKEDEN HOLLOWCREEK | NW-8-T11NR4E | Prestressed Box beam or girders - Multiple | -- | 2008 | -- | 68.9 | 71.5 | Good | 100.0 | 048339500000000 |
NBI report | CH 16 | FITCH CREEK | CNTR SEC 26 T13N,R4E | Prestressed Box beam or girders - Multiple | -- | 2009 | -- | 79.1 | 81.7 | Good | 100.0 | 048338900000000 |
NBI report | FAS 1195 IL 180 | BR BRANDYWINE CR | 0.5 MI N OF US 150 | Steel Stringer/Multi-beam or girder | -- | 2009 | -- | 88.9 | 93.8 | Good | 99.3 | 048008900000000 |
NBI report | TR 23 | TRIB N HENDERSON CRK | NE-18-T13NR1E | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 44.9 | 46.9 | Good | 100.0 | 048339800000000 |
NBI report | TR 251 | SWAB RUN CREEK | NE-24-T10NR4E | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 65.0 | 66.9 | Good | 100.0 | 048339600000000 |
NBI report | TR 183 | NORTH CREEK | SW-7-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2011 | -- | 51.8 | 101.7 | Good | 100.0 | 048339700000000 |
NBI report | TR 119 | South Henderson Crk | NE-19-T12N-R1E | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 78.1 | 80.1 | Good | 100.0 | 048339900000000 |
NBI report | TR 29 | Mud Run Creek | NE-23-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 65.0 | 66.9 | Good | 100.0 | 048340300000000 |
NBI report | TR 81 | TRIB TO FORMAN CREEK | 2308N 1788E | Steel Culvert (2 spans) | -- | 2012 | -- | 8.9 | 20.7 | Good | 100.0 | 048503500000000 |
NBI report | US 150 | HENDERSON CREEK | 6.3 MI N OF US 34 | Prestressed Stringer/Multi-beam or girder | -- | 2012 | -- | 106.0 | 111.9 | Fair | 98.3 | 048008800000000 |
NBI report | US 150 (MAIN ST) | CEDAR CREEK, BNSF RR | 500 BLK W. MAIN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2012 | -- | 133.2 | 269.4 | Fair | 97.0 | 048602200000000 |
NBI report | N. SOANGETAHA RD | AT&SF RR (004647L) | SE-12-T11NR1E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2013 | -- | 67.9 | 160.8 | Good | 92.2 | 048606300000000 |
NBI report | TR 176/Barefoot Rd | COURT CREEK | W1/2-19-T11NR3E | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 108.9 | 109.9 | Good | 99.0 | 048338700000000 |
NBI report | TR 176/Barefoot Rd | BNSF RR | SW-19-T11NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2013 | -- | 60.0 | 169.3 | Good | 95.0 | 048992700000000 |
NBI report | TR 244 | FOREMAN CREEK | SE-34-T13NR3E | Prestressed Box beam or girders - Multiple | -- | 2013 | -- | 77.8 | 80.1 | Good | 100.0 | 048340000000000 |
NBI report | FAU 6779- CO LINE | CEDAR CREEK TRIB | Galesburg | Prestressed Box beam or girders - Multiple | -- | 2014 | -- | 65.6 | 68.2 | Good | 100.0 | 048605200000000 |
NBI report | FAI 74EB | HENDERSON CREEK | 5.4 MI S HENRY CO LI | Prestressed Stringer/Multi-beam or girder | -- | 2015 | -- | 103.7 | 107.6 | Good | 97.3 | 048009000000000 |
NBI report | FAI 74WB | HENDERSON CREEK | 5.4 MI S HENRY CO LI | Prestressed Stringer/Multi-beam or girder | -- | 2015 | -- | 99.7 | 103.7 | Fair | 97.3 | 048009100000000 |
NBI report | IL 97 | Spoon River | 1 MI SE of Maquon | Steel Stringer/Multi-beam or girder (7 spans) | -- | 2015 | -- | 160.1 | 856.7 | Good | 98.1 | 048010000000000 |
NBI report | Main St / FAS 393 | Walnut Creek Trib | E.CTR-16-T13NR3E | Concrete Culvert | -- | 2015 | -- | 11.2 | 36.4 | Good | 99.9 | 048503700000000 |
NBI report | Seminary Street | BNSF Railroad | Galesburg | Steel Girder and floorbeam system | -- | 2015 | -- | 149.6 | 152.9 | Good | 80.3 | 048603000000000 |
NBI report | SEMINARY STREET | CEDAR CREEK | SE-10-T11NR1E | Concrete Culvert (2 spans) | -- | 2015 | -- | 20.3 | 42.3 | Good | 98.2 | 048606200000000 |
NBI report | TR 278 | WALNUT CREEK TRIB | 2 Mi W. of Il. 180 | Prestressed Box beam or girders - Multiple | -- | 2015 | -- | 67.3 | 69.9 | Good | 100.0 | 048340400000000 |
NBI report | TR 304 | SWAB RUB CREEK | 1.3 Mi N. of Ill. 8 | Prestressed Box beam or girders - Multiple | -- | 2015 | -- | 74.2 | 77.1 | Good | 100.0 | 048340100000000 |
NBI report | CH 11 | SPOON RIVER | NE-1-T10NR3E | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2016 | -- | 86.9 | 217.9 | Good | 100.0 | 048340200000000 |
NBI report | CH 7 | SUGAR CREEK | 3 Mi. S. of Ill. 167 | Prestressed Box beam or girders - Multiple | -- | 2016 | -- | 66.9 | 69.9 | Good | 84.5 | 048339000000000 |
NBI report | FAS 1400-CH 9 | EB and WB I 74 | Knoxville Interchang | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2016 | -- | 126.6 | 401.3 | Good | 98.7 | 048009900000000 |
NBI report | ILL 97 | LITTLE HAW CR | 4 MI NW OF MAQUON | Steel Stringer/Multi-beam or girder | -- | 2016 | -- | 74.2 | 77.4 | Good | 95.4 | 048009700000000 |
NBI report | ILL 97 | HAW CREEK TRIB. | 6.5 MI NW OF MAQUON | Prestressed Stringer/Multi-beam or girder | -- | 2016 | -- | 75.1 | 78.7 | Good | 93.7 | 048009800000000 |
NBI report | BNSF RR | FAU 6800 US 150/Main | 1.43mi west of I-74 | Steel Stringer/Multi-beam or girder | -- | 2017 | -- | 94.5 | -- | -- | -- | 048992800000000 |
NBI report | TR-65 | Fitch Creek | 3.5 Mi W of IL 78 | Prestressed Box beam or girders - Multiple | -- | 2017 | -- | 66.9 | 69.9 | Good | 100.0 | 048340500000000 |
NBI report | WB I 74 | BN(079799R)& Lincoln | 0.73MI S of US 34 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2017 | -- | 117.1 | 324.2 | Good | 97.2 | 048010100000000 |
NBI report | EB I 74 | BN(079799R) &Lincoln | 0.73MI S of US 34 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2018 | -- | 117.1 | 324.2 | Good | 97.2 | 048010200000000 |
NBI report | US 150 | BN RR(063001F) | 3 M SE GALESBURG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2018 | -- | 75.1 | 190.0 | Good | 98.6 | 048009600000000 |