Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | DUNBAR Rd | BIG WALNUT Creek | 00.50 W of CR 125 W | Wood Truss - Thru (2 spans) | NR eligible | 1880 | -- | 86.0 | 174.9 | Poor | 18.0 | 6700091 |
NBI report Bridgehunter | HUFFMAN Rd | BIG WALNUT Creek | 00.10 E of CR 600 W | Wood Truss - Thru (2 spans) | NR eligible | 1880 | -- | 128.9 | 264.4 | Poor | 29.4 | 6700148 |
NBI report Bridgehunter | CR 25E | DEER CREEK | 00.50 N of US 40 | Metal Truss - Thru | NR eligible | 1890 | -- | 112.2 | 116.5 | Poor | 28.0 | 6700161 |
NBI report Bridgehunter | CR 375W | BIG WALNUT Creek | 00.50 N of CR 300 S | Wood Truss - Thru | NR eligible | 1898 | -- | 150.6 | 171.9 | Poor | 13.3 | 6700107 |
NBI report Bridgehunter | CR 650N | BIG WALNUT Creek | 00.80 W of CR 500 E | Wood Truss - Thru | NR eligible | 1901 | 2017 | 122.1 | 125.7 | Good | 46.4 | 6700039 |
NBI report Bridgehunter | CR 450S | BR MILL CREEK | 00.80 E of CR 1000 E | Steel Truss - Thru | NR eligible | 1905 | 1985 | 80.1 | 81.0 | Poor | 29.5 | 6700182 |
NBI report Bridgehunter | US 231 | CSX RR | 01.79 N SR 240 | Concrete Culvert | -- | 1906 | -- | 29.9 | -- | -- | -- | 016020 |
NBI report Bridgehunter | DEVIL BACKBONE Rd | DEER Creek | 01.00 NW of US 40 | Steel Truss - Thru | NR eligible | 1906 | 2006 | 86.3 | 93.8 | Fair | 54.5 | 6700131 |
NBI report Bridgehunter | CR 100E | CONRAIL RR | 00.10 N of ALBIN POND Rd | Concrete Stringer/Multi-beam or girder (5 spans) | NR eligible | 1907 | 2004 | 33.5 | 124.0 | Fair | 76.9 | 6700222 |
NBI report Bridgehunter | CR 400E | CONRAIL RR | 00.01 N of ALBIN POND Rd | Concrete Stringer/Multi-beam or girder (5 spans) | NR eligible | 1908 | -- | 33.1 | 116.1 | Poor | 20.5 | 6700223 |
NBI report Bridgehunter | CR 400W | CONRAIL RR | 00.60 S of CR 125 S | Concrete Stringer/Multi-beam or girder (5 spans) | NR eligible | 1908 | -- | 42.7 | 166.0 | Poor | 19.3 | 6700217 |
NBI report Bridgehunter | DNR SERVICE ROAD | DEER CREEK | 01.94 S US 40 | Steel Truss - Thru | NR eligible | 1908 | 2003 | 99.1 | 102.0 | Fair | 50.6 | 060030 |
NBI report Bridgehunter | CR 600W | CONRAIL RR | 00.20 S of CR 275 S | Concrete Stringer/Multi-beam or girder (4 spans) | Closed ~ NR eligible | 1909 | -- | 32.2 | 187.0 | -- | 24.4 | 6700219 |
NBI report Bridgehunter | CR 275S | CONRAIL RR | 00.50 E of CR 600 W | Concrete Stringer/Multi-beam or girder (5 spans) | NR eligible | 1910 | -- | 33.5 | 118.1 | Poor | 20.5 | 6700218 |
NBI report Bridgehunter | CR 125N | BIG WALNUT CREEK | 00.50 N CR 100 N | Steel Truss - Thru | Closed ~ NR eligible | 1910 | 1984 | 160.1 | 162.1 | -- | 18.2 | 6700124 |
NBI report | CR 350S | OWL Branch Creek | 00.50 E of US 231 | Prestressed Box beam or girders - Multiple | -- | 1910 | 1988 | 59.7 | 63.0 | Good | 92.5 | 6700134 |
NBI report Bridgehunter | CR 925E | COTTON BRANCH CREEK | 00.20 S of CR 400 S | Concrete Stringer/Multi-beam or girder | -- | 1911 | -- | 40.4 | 44.0 | Fair | 60.3 | 6700199 |
NBI report Bridgehunter | CR 500E | CLEAR Creek | 00.30 N of CR 300 N | Steel Truss - Thru | NR eligible | 1915 | -- | 87.9 | 89.9 | Poor | 23.1 | 6700057 |
NBI report Bridgehunter | CR 800N | BIG WALNUT CREEK | 01.40 W CR 500 E | Wood Truss - Thru | NR eligible | 1915 | -- | 99.1 | 103.4 | Fair | 24.5 | 6700204 |
NBI report Bridgehunter | CR 875S | HIGGINS BRANCH CREEK | 00.20 W of CR 600 E | Concrete Arch - Deck | -- | 1915 | -- | 42.7 | 42.7 | Poor | 48.0 | 6700190 |
NBI report Bridgehunter | CR 900E | BIG WALNUT Creek | 00.80 N of CR 1100 N | Steel Truss - Thru | NR eligible | 1915 | -- | 136.2 | 144.4 | Poor | 26.8 | 6700032 |
NBI report Bridgehunter | CR 900N | BIG WALNUT Creek | 00.70 W of CR 500 E | Wood Truss - Thru (2 spans) | NR eligible | 1915 | 1988 | 104.3 | 216.2 | Fair | 28.0 | 6700045 |
NBI report Bridgehunter | CR 1350N | CORNSTALK Creek | 00.80 W of CR 50 W | Wood Truss - Thru | NR eligible | 1917 | 1990 | 80.1 | 84.0 | Fair | 42.2 | 6700017 |
NBI report Bridgehunter | CR 175E | BLEDSOE BRANCH CREEK | 00.40 N CR 500 N | Concrete Arch - Deck | -- | 1920 | -- | 25.9 | 26.9 | Fair | 54.7 | 6700041 |
NBI report | CR 300S | SALLUST BRANCH CREEK | 00.50 E of CR 1000 E | Concrete Girder and floorbeam system | -- | 1920 | -- | 39.4 | 44.3 | Poor | 36.7 | 6700178 |
NBI report | CR 625W | MAIDEN RUN | 00.30 N of CR 670 S | Concrete Slab | -- | 1920 | -- | 24.9 | 27.9 | Poor | 32.6 | 6700135 |
NBI report | CR 875E | BR MILL CREEK | 00.40 N of CR 1050 S | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 20.0 | 21.7 | Fair | 47.0 | 6700227 |
NBI report | CR 350N | FALLS Branch Creek | 00.30 E of CR 200 W | Prestressed Box beam or girders - Multiple | -- | 1920 | 1965 | 25.9 | 27.9 | Fair | 73.7 | 6700069 |
NBI report | MORTON Rd | OWL Creek | 00.70 NW of CR 500 N | Prestressed Box beam or girders - Multiple | -- | 1920 | 1976 | 49.9 | 52.2 | Fair | 89.7 | 6700071 |
NBI report | CR 500E | Little DEER Creek | 00.30 S of CR 300 S | Prestressed Box beam or girders - Multiple | -- | 1920 | 1977 | 64.6 | 68.2 | Fair | 79.1 | 6700118 |
NBI report | CR 800S | VERMILLION Branch Creek | 00.20 W of CR 750 E | Prestressed Box beam or girders - Multiple | -- | 1920 | 1978 | 33.5 | 36.4 | Poor | 49.2 | 6700193 |
NBI report | CR 300N | MILLER Creek | 00.20 E of CR 550 E | Prestressed Box beam or girders - Multiple | -- | 1920 | 1979 | 45.9 | 48.6 | Fair | 68.4 | 6700055 |
NBI report | CR 1100N | Branch of N RAMP Creek | 00.10 E of CR 100 E | Prestressed Box beam or girders - Multiple | -- | 1920 | 1980 | 33.1 | 36.1 | Fair | 77.0 | 6700021 |
NBI report | CR 575E | CLEAR Creek | 00.20 N of CR 300 N | Prestressed Box beam or girders - Multiple | -- | 1920 | 1980 | 61.0 | 65.9 | Fair | 70.1 | 6700056 |
NBI report | CR 875W | Branch of RACCOON Creek | 00.20 N of CR 1125 N | Prestressed Box beam or girders - Multiple | -- | 1920 | 1980 | 27.6 | 31.5 | Fair | 83.5 | 6700002 |
NBI report | CR 250N | FALLS Branch Creek | 00.01 W of CR 375 W | Prestressed Box beam or girders - Multiple | -- | 1920 | 1984 | 33.5 | 36.1 | Poor | 64.2 | 6700075 |
NBI report | CR 775E | MILLER Creek | 00.20 S of CR 350 N | Prestressed Box beam or girders - Multiple | -- | 1920 | 1984 | 38.1 | 41.0 | Poor | 51.9 | 6700053 |
NBI report | CR 950N | PETERS Creek | 00.10 E of CR 400 W | Prestressed Box beam or girders - Multiple | -- | 1920 | 1984 | 32.5 | 35.1 | Fair | 63.1 | 6700008 |
NBI report | CR 625E | HIGGINS Branch Creek | 00.10 N of CR 1000 S | Prestressed Box beam or girders - Multiple | -- | 1920 | 1986 | 62.0 | 65.3 | Good | 78.0 | 6700188 |
NBI report | CR 750E | Branch of MILL Creek | 00.50 S of SR 42 | Prestressed Box beam or girders - Multiple | -- | 1920 | 1986 | 30.2 | 33.1 | Fair | 67.9 | 6700174 |
NBI report | CR 350W | RAMP Creek | 00.10 S of CR 1000 N | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1920 | 1987 | 41.3 | 87.3 | Fair | 71.0 | 6700006 |
NBI report Bridgehunter | CR 300N | CLEAR Creek | 00.10 W of CR 500 E | Prestressed Box beam or girders - Multiple | -- | 1920 | 2000 | 76.1 | 80.4 | Fair | 80.0 | 6700061 |
NBI report | CR 800W | Branch of LONG Branch Cr | 00.50 S of CR 75 S | Steel Stringer/Multi-beam or girder | -- | 1920 | 2002 | 20.7 | 22.6 | Poor | 46.7 | 6700102 |
NBI report Bridgehunter | CR 375E | CLEAR Creek | 00.40 N of CR 200 N | Steel Truss - Thru | NR eligible | 1920 | 2004 | 100.1 | 103.4 | Fair | 49.2 | 6700059 |
NBI report Bridgehunter | US 40 | SALLUST BRANCH | 00.50 W SR 75 | Concrete Stringer/Multi-beam or girder | NR eligible | 1921 | 1938 | 29.9 | 32.2 | Poor | 69.5 | 013740 |
NBI report Bridgehunter | CR 450N | Little WALNUT Creek | 00.10 W of CR 700 W | Wood Truss - Thru | NR eligible | 1922 | -- | 77.1 | 83.0 | Fair | 35.7 | 6700086 |
NBI report Bridgehunter | MORTON Rd | Branch of OWL Creek | 00.70 SE of US 36 | Concrete Arch - Deck | -- | 1922 | -- | 50.5 | 59.1 | Fair | 62.7 | 6700072 |
NBI report Bridgehunter | CR 550S | DEER CREEK | 00.20 W of CR 25 E | Concrete Arch - Deck (4 spans) | NR eligible | 1923 | -- | 75.5 | 276.9 | Poor | 60.3 | 6700200 |
NBI report Bridgehunter | CR 750S | BIG WALNUT Creek | 00.30 W of US 40 | Concrete Arch - Deck (3 spans) | NR eligible | 1923 | -- | 71.9 | 234.9 | Poor | 22.4 | 6700229 |
NBI report Bridgehunter | CR 200E | DRY BRANCH CREEK | 00.50 S of CR 200 N | Steel Stringer/Multi-beam or girder | Closed | 1925 | -- | 29.9 | 33.8 | Poor | 23.6 | 6700123 |
NBI report | CR 250W | JONES Creek | 00.70 S of CR 250 N | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 26.2 | 28.2 | Poor | 25.6 | 6700081 |
NBI report | CR 25E | MOSQUITO CREEK | 00.30 S of CR 700 S | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 25.9 | 27.6 | Poor | 30.5 | 6700157 |
NBI report | CR 50N | BR DEER CREEK | 00.20 W of CR 675 E | Concrete Slab | -- | 1925 | -- | 20.0 | 23.0 | Fair | 51.4 | 6700128 |
NBI report | CR 675S | BR BELLE UNION CR | 00.40 W of CR 1000 E | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 29.9 | 33.8 | Poor | 28.9 | 6700163 |
NBI report | CR 800N | CLEAR CREEK | 00.80 E of CR 725 E | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 20.0 | 23.0 | Poor | 16.3 | 6700202 |
NBI report | CR 850N | S RAMP CREEK | 00.30 W of CR 25 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1925 | -- | 19.4 | 44.3 | Poor | 22.8 | 6700205 |
NBI report | POLAND Rd | SLATE RUN | 00.50 W of CR 550 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 27.9 | 30.8 | Fair | 50.7 | 6700151 |
NBI report | CR 50S | Branch of DEER Creek | 00.40 W of CR 550 E | Prestressed Box beam or girders - Multiple | -- | 1925 | 1988 | 31.5 | 35.1 | Fair | 73.6 | 6700127 |
NBI report | CR 600N | CLEAR Creek | 00.10 E of CR 725 E | Prestressed Box beam or girders - Multiple | -- | 1925 | 1993 | 28.9 | 29.9 | Fair | 75.9 | 6700048 |
NBI report | CR 675E | HIGGINS Branch Creek | 00.40 N of SR 42 | Steel Stringer/Multi-beam or girder | -- | 1925 | 2005 | 30.2 | 33.1 | Fair | 93.5 | 6700171 |
NBI report Bridgehunter | CR 500N | CLEAR Creek | 00.20 W of CR 700 E | Concrete Arch - Deck | NR eligible | 1927 | -- | 37.1 | 55.1 | Fair | 52.7 | 6700049 |
NBI report Bridgehunter | CR 600S | BR BELLE UNION CR | 00.10 W of CR 1000 E | Concrete Arch - Deck | -- | 1927 | 1970 | 30.5 | 44.3 | Fair | 71.2 | 6700167 |
NBI report | CR 750E | DEER Creek | 00.90 S of CR 100 N | Steel Stringer/Multi-beam or girder | -- | 1928 | -- | 29.2 | 31.8 | Fair | 39.5 | 6700113 |
NBI report Bridgehunter | CR 925E | BR MILL CREEK | 00.20 S of CR 900 S | Concrete Arch - Deck | NR eligible | 1929 | -- | 76.4 | 128.0 | Poor | 46.5 | 6700196 |
NBI report | CR 100E | Branch of N RAMP CREEK | 00.20 N of CR 1100 N | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 27.9 | 33.1 | Poor | 26.6 | 6700022 |
NBI report | CR 1200S | BR CROYS CREEK | 00.40 W of CR 700 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 27.9 | 30.5 | Poor | 36.2 | 6700146 |
NBI report Bridgehunter | CR 1200S | MILL Creek | 00.50 E of CR 600 E | Steel Truss - Thru (2 spans) | -- | 1930 | -- | 84.0 | 172.9 | Fair | 56.5 | 6700175 |
NBI report Bridgehunter | CR 200N | DRY Branch Creek | 00.10 E of CR 200 E | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 34.1 | 36.7 | Fair | 38.4 | 6700067 |
NBI report | CR 675W | Branch of LEATHERMAN Cr | 00.20 S of CR 125 N | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 22.6 | 25.9 | Poor | 31.6 | 6700093 |
NBI report | CR 750E | DEER Creek | 00.30 S of CR 100 N | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 29.9 | 32.5 | Fair | 77.5 | 6700115 |
NBI report | CR 750W | BR MAIDEN RUN | 00.50 N of CR 600 S | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 20.3 | 23.0 | Poor | 17.7 | 6700136 |
NBI report Bridgehunter | CR 775W | BR CROYS CREEK | 00.50 S of CR 1200 S | Concrete Arch - Deck | -- | 1930 | -- | 20.0 | 34.1 | Fair | 59.7 | 6700224 |
NBI report | CR 800S | BR MILL CREEK | 00.30 E of CR 950 E | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 24.6 | 26.9 | Poor | 20.3 | 6700198 |
NBI report | CR 50E | CLINE Creek | 00.10 S of CR 1400 N | Prestressed Box beam or girders - Multiple | -- | 1930 | 1986 | 28.9 | 32.2 | Fair | 82.1 | 6700018 |
NBI report | INDIANA St | HENRY/CLINE Creek | 00.20 S of US 236 | Prestressed Box beam or girders - Multiple | -- | 1930 | 1993 | 24.3 | 26.6 | Fair | 96.8 | 6700232 |
NBI report | CR 375W | Branch of BIG RACCOON Cr | 01.00 S of SR 236 | Prestressed Box beam or girders - Multiple | -- | 1930 | 1995 | 26.6 | 27.9 | Good | 87.0 | 6700005 |
NBI report | US 231 | DOE CREEK | 00.33 N of SR 42 | Concrete Culvert | -- | 1931 | -- | 24.0 | 26.9 | Fair | 86.1 | 015980 |
NBI report | US 36 | WEST FORK PLUM CREEK | 04.99 W SR 75 | Concrete Arch - Deck | -- | 1931 | -- | 36.1 | 39.0 | Fair | 77.8 | 011590 |
NBI report Bridgehunter | US 36 | MOCCASIN BRANCH | 03.83 W US 231 | Concrete Arch - Deck | -- | 1931 | 1968 | 40.0 | 58.1 | Fair | 85.6 | 011570 |
NBI report Bridgehunter | US 36 | EAST FORK PLUM CREEK | 04.17 W SR 75 | Concrete Arch - Deck | -- | 1931 | 1968 | 40.0 | 58.1 | Poor | 66.0 | 011600 |
NBI report Bridgehunter | US 231 | BIG WALNUT CREEK | 02.54 N SR 240 | Concrete Arch - Deck (3 spans) | -- | 1931 | 1969 | 65.0 | 204.1 | Fair | 96.3 | 016030 |
NBI report Bridgehunter | US 231 | JONES CREEK | 04.07 S US 36 | Concrete Arch - Deck | -- | 1931 | 2017 | 36.1 | 43.0 | Good | 93.8 | 016040 |
NBI report Bridgehunter | US 231 | DEER CREEK | 00.36 N US 40 | Concrete Arch - Deck (2 spans) | -- | 1932 | 1997 | 60.0 | 126.0 | Fair | 93.2 | 016010 |
NBI report | CR 1000N | BRANCH OF N RAMP CREEK | 00.20 W of CR 100 E | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 24.3 | 27.2 | Poor | 22.2 | 6700025 |
NBI report | CR 250E | UPPER LIMESTONE CREEK | 00.60 S of US 40 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1935 | -- | 18.4 | 40.0 | Poor | 28.6 | 6700159 |
NBI report | CR 250W | ROCKY FORK CR | 00.70 N of CR 900 S | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 29.9 | 33.5 | Fair | 58.5 | 6700154 |
NBI report | CR 25E | BR DOE CREEK | 00.20 N of CR 1250 S | Concrete Stringer/Multi-beam or girder | -- | 1935 | -- | 28.2 | 33.8 | Fair | 52.5 | 6700187 |
NBI report Bridgehunter | CR 300S | DEER Creek | 00.70 E of CR 275 E | Steel Truss - Thru | -- | 1935 | -- | 84.0 | 87.9 | Fair | 55.8 | 6700133 |
NBI report | CR 450W | Branch LITTLE WALNUT Cr | 00.20 N of CR 100 S | Concrete Stringer/Multi-beam or girder | -- | 1935 | -- | 29.9 | 33.8 | Poor | 39.3 | 6700092 |
NBI report | CR 625W | Little WALNUT Creek | 00.20 N of CR 350 N | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 31.5 | 35.4 | Poor | 29.3 | 6700078 |
NBI report | CR 675E | DEER CREEK | 00.40 S of CR 50 N | Concrete Stringer/Multi-beam or girder | -- | 1935 | -- | 29.9 | 33.5 | Fair | 59.2 | 6700129 |
NBI report | CR 750W | Little WALNUT Creek | 00.30 N of CR 500 N | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 28.2 | 30.5 | Fair | 57.8 | 6700077 |
NBI report | US 40 | WALLACE BRANCH | 02.33 E US 231 | Concrete Culvert | -- | 1937 | -- | 24.9 | 27.9 | Good | 82.0 | 013730 |
NBI report Bridgehunter | US 40 | DEER CREEK | 00.76 E SR 243 | Concrete Arch - Deck (3 spans) | NR eligible | 1937 | 1992 | 75.1 | 162.1 | Fair | 99.4 | 013720 |
NBI report | CR 1100N | Branch of N RAMP Creek | 00.40 W of CR 100 E | Concrete Stringer/Multi-beam or girder | -- | 1940 | -- | 34.5 | 38.1 | Fair | 62.7 | 6700020 |
NBI report | CR 150W | DEWEESE Branch Creek | 00.90 S of CR 300 S | Concrete Stringer/Multi-beam or girder | -- | 1940 | -- | 29.9 | 33.1 | Poor | 35.1 | 6700108 |
NBI report | CR 175S | BR LONG BRANCH CRK | 00.50 W of CR 800 W | Concrete Slab | -- | 1940 | -- | 20.3 | 22.6 | Fair | 41.3 | 6700103 |
NBI report | CR 25W | FALLS BRANCH CREEK | 00.10 N of CR 500 N | Concrete Slab | -- | 1940 | -- | 20.3 | 23.0 | Fair | 60.4 | 6700225 |
NBI report Bridgehunter | CR 375W | LEATHERWOOD CREEK | 00.50 N of CR 950 S | Concrete Culvert | -- | 1940 | -- | 29.9 | 29.9 | Poor | 32.2 | 6700153 |
NBI report | CR 500N | FALLS Branch Creek | 00.30 E of CR 25 W | Concrete Slab | -- | 1940 | -- | 20.3 | 25.9 | Poor | 37.9 | 6700064 |
NBI report | CR 650S | JOHNSON BRANCH CREEK | 00.10 E of CR 900 W | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 25.3 | 28.2 | Fair | 60.7 | 6700137 |
NBI report | CR 925E | SALLUST BRANCH CREEK | 00.30 S of US 40 | Concrete Girder and floorbeam system | -- | 1940 | -- | 25.6 | 28.5 | Poor | 22.4 | 6700177 |
NBI report Bridgehunter | US 40 | DEWEY BRANCH | 03.35 W SR 243 | Concrete Arch - Deck | -- | 1940 | -- | 40.0 | 42.0 | Fair | 82.8 | 013690 |
NBI report Bridgehunter | SR 42 | MILL CREEK | 03.47 E US 231 | Steel Truss - Thru | -- | 1940 | 1974 | 174.9 | 180.1 | Fair | 65.7 | 015830 |
NBI report Bridgehunter | US 40 | WALNUT CREEK | 06.61 W SR 243 | Concrete Arch - Deck (3 spans) | -- | 1940 | 1986 | 120.1 | 233.9 | Fair | 98.9 | 013680 |
NBI report | US 40 | JOHNSON BRANCH | 07.04 E SR 59 | Prestressed Stringer/Multi-beam or girder | -- | 1940 | 2003 | 37.4 | 39.0 | Good | 96.6 | 013670 |
NBI report | CR 1050S | CHURCH CREEK | 00.60 E of CR 900 W | Concrete Slab | -- | 1945 | -- | 20.0 | 23.3 | Fair | 55.3 | 6700141 |
NBI report | CR 1275S | DITCH | 00.20 W of CR 700 W | Concrete Slab | -- | 1945 | -- | 20.3 | 23.3 | Fair | 75.8 | 6700228 |
NBI report | SR 75 | MCHAFFIE BRANCH | 00.08 N US 40 | Concrete Slab (3 spans) | -- | 1947 | 1997 | 32.2 | 81.0 | Fair | 96.5 | 024760 |
NBI report Bridgehunter | CR 650N | PLUM Creek | 00.40 W of CR 600 E | Concrete Stringer/Multi-beam or girder (2 spans) | -- | 1950 | -- | 25.9 | 52.2 | Fair | 59.7 | 6700037 |
NBI report | CR 500N | PLUM Creek | 00.10 W of CR 475 E | Prestressed Box beam or girders - Multiple | -- | 1950 | 1992 | 69.6 | 73.2 | Fair | 87.2 | 6700043 |
NBI report | CR 1000E | BR BELLE UNION CR | 00.10 N of CR 600 S | Concrete Channel beam | -- | 1955 | -- | 34.1 | 36.1 | Poor | 28.5 | 6700184 |
NBI report Bridgehunter | CR 650N | PLUM Creek | 00.20 E of CR 600 E | Concrete Stringer/Multi-beam or girder | NR eligible | 1955 | -- | 27.2 | 30.8 | Fair | 63.2 | 6700036 |
NBI report | CR 650N | Branch of PLUM Creek | 00.30 E of CR 500 E | Concrete Stringer/Multi-beam or girder | -- | 1955 | -- | 24.0 | 25.9 | Fair | 47.9 | 6700038 |
NBI report | SR 236 | BIG RACCOON CREEK | 01.37 W US 231 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1955 | 2018 | 75.1 | 289.7 | Fair | 83.7 | 029820 |
NBI report | CR 800E | BIG WALNUT Creek | 00.80 N of CR 1100 N | Concrete Stringer/Multi-beam or girder (4 spans) | -- | 1957 | -- | 59.4 | 207.7 | Fair | 84.0 | 6700033 |
NBI report | CR 500N | BIG WALNUT Creek | 00.30 E of CR 400 E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1958 | -- | 92.9 | 221.5 | Fair | 81.4 | 6700042 |
NBI report | MORTON Rd | BIG RACCOON Creek | 00.40 S of CR 900 N | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2018 | 89.9 | 339.9 | Fair | 85.9 | 6700014 |
NBI report | CR 1000E | COTTON BRANCH CREEK | 00.20 N of CR 450 S | Concrete Channel beam | -- | 1960 | -- | 38.1 | 40.0 | Fair | 73.0 | 6700180 |
NBI report | CR 1000S | HIGGINS BRANCH CREEK | 00.50 W of CR 700 E | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 44.9 | 49.9 | Poor | 47.7 | 6700165 |
NBI report | CR 50N | SNYDER Branch Creek | 00.70 W of CR 25 E | Concrete Channel beam | -- | 1960 | -- | 36.1 | 40.0 | Fair | 65.5 | 6700125 |
NBI report | CR 850N | South RAMP Creek | 00.60 W of CR 25 W | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 41.0 | 44.9 | Fair | 69.1 | 6700207 |
NBI report | CR 850N | South RAMP Creek | 00.80 W of CR 25 W | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 41.0 | 44.9 | Fair | 86.0 | 6700208 |
NBI report | MORTON Rd | Branch of BIG RACCOON Cr | 00.00 N of CR 900 N | Concrete Culvert | -- | 1960 | -- | 23.3 | 26.9 | Fair | 95.9 | 6700012 |
NBI report | WALNUT Rd | BIG WALNUT Creek | 00.70 E of CR 300 E | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1960 | -- | 63.0 | 316.0 | Fair | 77.1 | 6700098 |
NBI report | CR 250E | LICK Creek | 00.20 S of CR 1400 N | Concrete Slab (3 spans) | -- | 1962 | -- | 30.8 | 86.0 | Fair | 80.7 | 6700019 |
NBI report | CR 400W | JONES Creek | 01.00 W of CR 325 W | Concrete Slab (3 spans) | -- | 1962 | -- | 34.5 | 92.5 | Fair | 73.9 | 6700099 |
NBI report | CR 525W | MILL Creek | 00.30 S of CR 1100 S | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1963 | -- | 67.9 | 202.1 | Poor | 82.8 | 6700150 |
NBI report | SR 240 | LITTLE DEER CREEK | 03.22 W SR 75 | Concrete Slab | -- | 1964 | 2017 | 48.9 | 49.9 | Good | 97.0 | 029980 |
NBI report | CR 525E | BIG WALNUT Creek | 00.30 N of CR 1050 N | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 60.0 | 182.1 | Fair | 87.4 | 6700044 |
NBI report | CR 675E | MILLER Creek | 00.20 S of CR 300 N | Concrete Channel beam | -- | 1965 | -- | 38.1 | 40.0 | Fair | 74.0 | 6700054 |
NBI report | JOHN GREY ROAD | I-70 EB | 01.75 W SR 243 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 56.1 | 138.1 | Fair | 82.9 | 041580 |
NBI report | JOHN GREY ROAD | I-70 WB | 01.75 W SR 243 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 56.1 | 139.1 | Fair | 82.9 | 041590 |
NBI report | POPLAR GROVE ROAD | I-70 EB/WB | 01.43 E SR 243 | Concrete Stringer/Multi-beam or girder (4 spans) | -- | 1965 | -- | 71.2 | 225.1 | Fair | 72.9 | 041600 |
NBI report | I-70 EB | CSX RR | 00.59 W US 231 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1995 | 64.3 | 173.9 | Fair | 96.3 | 041610 |
NBI report | I-70 EB | US 231 SB/NB | 04.02 E SR 243 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 1995 | 67.9 | 140.1 | Fair | 96.0 | 041620 |
NBI report | I-70 EB | VERMILLION CREEK | 04.57 E US 231 | Concrete Slab (3 spans) | -- | 1965 | 1995 | 40.0 | 100.1 | Fair | 96.3 | 041660 |
NBI report | I-70 WB | CSX RR | 00.59 W US 231 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1995 | 64.3 | 173.9 | Fair | 96.3 | 041615 |
NBI report | I-70 WB | US 231 SB/NB | 04.02 E SR 243 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 1995 | 67.9 | 140.1 | Fair | 86.0 | 041630 |
NBI report | I-70 WB | VERMILLION CREEK | 04.57 E US 231 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1995 | 56.1 | 138.1 | Fair | 95.7 | 041670 |
NBI report | CR 1000E | I-70 EB/WB | 07.43 E US 231 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 2016 | 71.9 | 230.0 | Fair | 93.9 | 041690 |
NBI report | CR 475E | I-70 EB/WB | 01.93 E US 231 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 2016 | 68.2 | 219.8 | Fair | 82.9 | 041640 |
NBI report | CR 650 E/HIGGINS R | I-70 EB/WB | 03.74 E US 231 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 2016 | 77.1 | 236.6 | Fair | 96.0 | 041650 |
NBI report | CR 825E | I-70 EB/WB | 05.58 E US 231 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1965 | 2016 | 66.6 | 212.0 | Good | 84.9 | 041680 |
NBI report | SR 243 | I-70 EBL | 05.46 N SR 42 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 2017 | 56.1 | 137.1 | Fair | 94.6 | 030050 |
NBI report | SR 243 | I-70 WB | 05.52 N SR 42 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 2017 | 56.1 | 137.1 | Good | 94.6 | 030060 |
NBI report | US 231 | UPPER LIMESTONE CREEK | 00.53 S US 40 | Steel Culvert (2 spans) | -- | 1966 | -- | 14.4 | 36.1 | Fair | 92.4 | 029384 |
NBI report | I-70 EB | CROYS CREEK | 07.10 W SR 243 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1984 | 53.5 | 134.8 | Fair | 95.9 | 041480 |
NBI report | I-70 EB | KNIGHT ROAD | 04.69 W SR 243 | Concrete Slab (3 spans) | -- | 1966 | 1984 | 45.9 | 113.9 | Fair | 96.6 | 041510 |
NBI report | I-70 WB | CROYS CREEK | 07.10 W SR 243 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1984 | 53.5 | 134.8 | Good | 95.9 | 041490 |
NBI report | I-70 WB | KNIGHT ROAD | 04.69 W SR 243 | Concrete Slab (3 spans) | -- | 1966 | 1984 | 45.9 | 113.9 | Fair | 96.6 | 041520 |
NBI report | I-70 EB | BIG WALNUT CREEK | 04.51 W SR 243 | Concrete Stringer/Multi-beam or girder (6 spans) | -- | 1966 | 1993 | 85.0 | 458.0 | Fair | 89.2 | 041530 |
NBI report | I-70 WB | BIG WALNUT CREEK | 04.51 W SR 243 | Concrete Stringer/Multi-beam or girder (6 spans) | -- | 1966 | 1993 | 85.0 | 458.0 | Fair | 89.2 | 041540 |
NBI report | I-70 EB | MILL CREEK | 08.19 E US 231 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1995 | 79.1 | 272.0 | Fair | 94.2 | 041700 |
NBI report | I-70 WB | MILL CREEK | 08.19 E US 231 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1995 | 79.1 | 272.0 | Fair | 93.3 | 041710 |
NBI report | SR 240 | BUIS CREEK | 01.10 W SR 75 | Concrete Slab (3 spans) | -- | 1966 | 1996 | 22.0 | 56.8 | Fair | 86.8 | 029990 |
NBI report | SR 243 | DEER CREEK | 00.46 S US 40 | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1997 | 69.9 | 171.9 | Fair | 97.1 | 030090 |
NBI report | US 231 | BR LOWER LIMESTONE CREEK | 01.09 N I-70 | Concrete Slab (3 spans) | -- | 1966 | 2001 | 42.0 | 104.0 | Good | 88.7 | 015990 |
NBI report | US 231 | LOWER LIMESTONE CREEK | 01.49 N I-70 | Concrete Slab (3 spans) | -- | 1966 | 2001 | 34.1 | 86.0 | Fair | 70.1 | 016000 |
NBI report | I-70 EB | DEER CREEK | 02.78 W SR 243 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1966 | 2006 | 76.8 | 309.1 | Good | 96.6 | 041560 |
NBI report | I-70 WB | DEER CREEK | 02.78 W SR 243 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1966 | 2006 | 76.1 | 364.8 | Fair | 94.5 | 041570 |
NBI report | SR 240 | DEER CREEK | 04.25 E US 231 | Concrete Slab (3 spans) | -- | 1966 | 2015 | 45.6 | 112.2 | Good | 97.5 | 029970 |
NBI report | MANHATTAN ROAD | I-70 EB/WB | 03.92 W SR 243 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1966 | 2016 | 64.6 | 211.3 | Fair | 82.0 | 041550 |
NBI report | RAAB ROAD | I-70 EB/WB | 06.66 W SR 243 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1966 | 2016 | 77.4 | 248.7 | Fair | 89.1 | 041500 |
NBI report | WALNUT Rd (125S) | Little WALNUT Creek | 00.10 W of CR 450 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 51.8 | 154.2 | Fair | 77.0 | 6700095 |
NBI report | CR 600W | Little WALNUT Creek | 00.20 S of CR 350 N | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1968 | -- | 49.9 | 149.9 | Fair | 86.8 | 6700083 |
NBI report | CR 100E | North RAMP CREEK | 00.50 N of CR 1100 N | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 21.0 | 24.0 | Good | 85.0 | 6700023 |
NBI report | CR 1350N | Branch of RACCOON Creek | 00.50 W of CR 800 W | Concrete Channel beam | -- | 1970 | -- | 30.8 | 34.1 | Fair | 67.1 | 6700001 |
NBI report | CR 150W | CLINE CREEK | 01.50 S CR 300 S | Steel Culvert (3 spans) | -- | 1970 | -- | 8.9 | 29.9 | Poor | 47.9 | 6700237 |
NBI report | CR 225W | FALLS Branch Creek | 00.20 S of CR 350 N | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 49.9 | 55.1 | Fair | 73.0 | 6700089 |
NBI report | CR 625W | LONG Branch Creek | 00.10 S of CR 100 S | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 54.5 | 59.1 | Good | 87.0 | 6700104 |
NBI report | CR 850N | South RAMP Creek | 00.50 W of CR 25 W | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 44.6 | 47.6 | Good | 86.0 | 6700206 |
NBI report | EAST QUARRY Rd | DEER Creek | 00.50 SE of US 40 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1970 | -- | 49.9 | 149.9 | Fair | 78.4 | 6700147 |
NBI report | MORTON Rd | BYRD Branch CREEK | 00.10 E of CR 725 W | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 22.0 | 24.9 | Fair | 75.6 | 6700013 |
NBI report | CR 275E | DEER Creek | 00.40 S of CR 350 S | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1971 | -- | 29.9 | 89.9 | Fair | 75.6 | 6700160 |
NBI report | CR 775E | MILL Creek | 00.80 N of SR 42 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1971 | -- | 52.2 | 262.2 | Fair | 98.9 | 6700194 |
NBI report | SR 243 | FALL CREEK | 01.81 S I-70 | Concrete Slab (3 spans) | -- | 1972 | 2016 | 32.2 | 82.0 | Fair | 98.4 | 030040 |
NBI report | CR 700S | VERMILLION Branch Creek | 00.50 W of CR 750 E | Concrete Culvert | -- | 1975 | -- | 23.0 | 26.6 | Good | 98.9 | 6700162 |
NBI report | CR 175N | Little WALNUT Creek | 00.10 E of CR 550 W | Steel Culvert (3 spans) | -- | 1976 | -- | 16.1 | 55.4 | Fair | 79.0 | 6700088 |
NBI report | CR 1100E | MILL Creek | 00.50 S of CR 300 S | Prestressed Box beam or girders - Multiple | -- | 1977 | -- | 44.9 | 47.9 | Fair | 74.0 | 6700179 |
NBI report | CR 150W | DEWEESE Branch Creek | 01.20 S of CR 300 S | Steel Culvert (3 spans) | -- | 1977 | -- | 8.5 | 30.8 | Poor | 39.6 | 6700110 |
NBI report | CR 775W | CROYS Creek | 00.20 S of CR 1200 S | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1978 | -- | 40.7 | 120.1 | Fair | 94.5 | 6700143 |
NBI report | CR 1390N | S Fork LITTLE RACCOON | 00.30 W of CR 750 W | Prestressed Box beam or girders - Multiple | -- | 1980 | -- | 20.7 | 24.0 | Fair | 88.0 | 6700235 |
NBI report | US 231 | BIG RACCOON CREEK | 00.07 N N Jct SR 236 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1981 | 2002 | 85.0 | 398.0 | Fair | 98.5 | 016070 |
NBI report | US 231 | ABANDONED RR | 00.35 N N Jct SR 236 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1981 | 2016 | 65.0 | 177.2 | Good | 98.3 | 016080 |
NBI report | CR 1000N | NORTH RAMP CREEK | 01.00 E of US 231 | Prestressed Box beam or girders - Multiple (3 spans) | NR eligible | 1982 | -- | 27.9 | 84.0 | Fair | 92.5 | 6700024 |
NBI report | CR 150W | JONES Creek | 00.30 N of CR 200 N | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 40.0 | 43.0 | Fair | 81.0 | 6700068 |
NBI report | CR 700S | MILL Creek | 00.40 E of CR 1000 E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1982 | -- | 89.9 | 238.9 | Fair | 86.4 | 6700164 |
NBI report | CR 125S | CONRAIL RR | 00.40 E of CR 300 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 85.0 | 211.6 | Good | 96.6 | 6700215 |
NBI report | CR 450S | COTTON Branch Creek | 00.40 E of CR 1000 E | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 38.7 | 42.0 | Fair | 80.5 | 6700181 |
NBI report | CR 1075S | DEER CREEK | 01.00 W of CR 300 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 60.0 | 181.8 | Fair | 83.0 | 6700152 |
NBI report | CR 840N | South RAMP Creek | 00.20 E of CR 25 W | Prestressed Box beam or girders - Multiple | -- | 1985 | -- | 48.9 | 53.5 | Good | 91.5 | 6700209 |
NBI report | US 40 | SERVICE RD - STATE FARM | 00.99 W SR 243 | Steel Culvert | -- | 1985 | -- | 32.5 | 34.1 | Fair | 63.6 | 013700 |
NBI report | US 40 | CSX RR | 00.25 E SR 243 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 79.1 | 213.9 | Fair | 91.2 | 013710 |
NBI report | CR 50N | DEER Creek | 00.30 E of CR 550 E | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 35.1 | 37.1 | Good | 93.5 | 6700238 |
NBI report | CR 550W | SNAKE Creek | 00.01 N of CR 375 S | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1986 | -- | 33.5 | 68.6 | Good | 78.8 | 6700106 |
NBI report | CR 750E | DEER Creek | 00.70 S of CR 100 N | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 36.1 | 40.0 | Good | 82.5 | 6700114 |
NBI report | SR 243 | ROCKY FORK CREEK | 00.41 N I-70 | Concrete Slab (3 spans) | -- | 1986 | -- | 33.1 | 87.9 | Fair | 79.7 | 030070 |
NBI report | SR 243 | MOSQUITO CREEK | 01.45 S US 40 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 46.6 | 142.1 | Fair | 89.6 | 030080 |
NBI report | CR 800W | JOHNSON Branch Creek | 00.20 S of US 40 | Prestressed Box beam or girders - Multiple | -- | 1987 | -- | 45.9 | 49.9 | Good | 90.0 | 6700140 |
NBI report | CR 900N | South RAMP Creek | 00.80 E of US 231 | Prestressed Box beam or girders - Multiple | -- | 1987 | -- | 59.1 | 62.0 | Fair | 94.5 | 6700026 |
NBI report | CR 975S | VERMILLION Branch Creek | 00.10 E of CR 775 E | Prestressed Box beam or girders - Multiple | -- | 1987 | -- | 49.9 | 53.2 | Fair | 89.9 | 6700166 |
NBI report | CR 800W | Br S Fork LITTLE RACCOON | 00.40 S of SR 236 | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 34.8 | 38.7 | Good | 90.0 | 6700221 |
NBI report | CR 550S | COTTON Branch Creek | 00.50 E of CR 1000 E | Prestressed Box beam or girders - Multiple | -- | 1989 | -- | 58.1 | 62.0 | Fair | 79.0 | 6700183 |
NBI report | MERIDIAN LINE Rd | North RAMP Creek | 00.30 S of CR 1100 N | Prestressed Box beam or girders - Multiple | -- | 1990 | -- | 52.5 | 55.1 | Good | 90.0 | 6700027 |
NBI report Bridgehunter | CR 375N | OWL Creek | 00.30 E of CR 600 W | Steel Culvert (2 spans) | -- | 1991 | -- | 14.4 | 31.2 | Good | 99.8 | 6700070 |
NBI report | CR 375N | Little WALNUT Creek | 00.20 E of CR 600 W | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 37.7 | 41.3 | Good | 83.3 | 6700084 |
NBI report | CR 600W | Little WALNUT Creek | 00.10 N of CR 350 N | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 52.8 | 56.1 | Good | 85.3 | 6700079 |
NBI report | CR 600W | Branch of RACCOON Creek | 00.50 N of CR 600 N | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 48.9 | 52.2 | Good | 85.4 | 6700080 |
NBI report | CR 600W | Little WALNUT Creek | 00.60 N of CR 350 N | Prestressed Box beam or girders - Multiple | -- | 1991 | -- | 27.9 | 31.5 | Good | 79.5 | 6700085 |
NBI report Bridgehunter | CR 850S | BIG WALNUT Creek | 00.10 E of CR 650 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 70.9 | 212.9 | Good | 99.0 | 6700139 |
NBI report | CR 275E | Branch of BIG WALNUT Cr | 00.20 N of CR 100 N | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 38.4 | 42.0 | Good | 90.0 | 6700058 |
NBI report Bridgehunter | CR 550W | Little WALNUT Creek | 00.60 S of CR 350 N | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1993 | -- | 24.9 | 75.1 | Good | 93.5 | 6700082 |
NBI report | SR 240 | BRANCH DEER CREEK | 03.92 E US 231 | Metal Culvert | -- | 1993 | -- | 20.3 | 21.0 | Good | 97.0 | 029950 |
NBI report | SR 42 | BRANCH DOE CREEK | 01.10 W US 231 | Concrete Culvert (2 spans) | -- | 1993 | -- | 11.2 | 24.0 | Good | 99.4 | 015825 |
NBI report | US 231 | RAMP CREEK | 02.75 N US 36 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 54.8 | 168.0 | Fair | 98.1 | 016060 |
NBI report | US 36 | CLEAR CREEK | 02.03 W SR 75 | Prestressed Stringer/Multi-beam or girder | -- | 1993 | -- | 91.9 | 94.2 | Good | 96.9 | 011620 |
NBI report | CR 1200S | CROYS Creek | 00.50 W of CR 775 W | Concrete Slab (3 spans) | -- | 1995 | -- | 45.9 | 103.0 | Good | 94.5 | 6700145 |
NBI report | CR 300S | Little DEER Creek | 00.30 W of CR 650 E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 45.9 | 48.9 | Good | 90.0 | 6700119 |
NBI report | CR 400S | COTTON Branch Creek | 00.20 E of CR 825 E | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 47.2 | 50.9 | Good | 90.0 | 6700168 |
NBI report | LAFAYETTE St | DOE Creek | 00.20 N of US 231 | Prestressed Stringer/Multi-beam or girder | -- | 1995 | -- | 76.4 | 80.4 | Good | 88.9 | 6700192 |
NBI report | US 40 EB | MCHAFFIE BRANCH | 00.07 E SR 75 | Concrete Slab (3 spans) | -- | 1995 | -- | 25.9 | 70.9 | Fair | 99.7 | 013750 |
NBI report | US 40 WB | MCHAFFIE BRANCH | 00.07 E SR 75 | Concrete Slab (3 spans) | -- | 1995 | -- | 25.9 | 70.9 | Fair | 88.7 | 013751 |
NBI report | CR 1000E | SALLUST BRANCH CREEK | 00.40 S of US 40 | Concrete Slab (3 spans) | -- | 1996 | -- | 29.5 | 77.4 | Good | 98.9 | 6700176 |
NBI report Bridgehunter | CR 300N | BIG WALNUT Creek | 00.10 E of CR 325 E | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1996 | -- | 98.1 | 200.1 | Good | 93.5 | 6700060 |
NBI report | DOE CREEK Rd | DOE Creek | 00.20 N of CR 1100 S | Prestressed Box beam or girders - Multiple | -- | 1996 | -- | 47.6 | 52.5 | Fair | 88.9 | 6700191 |
NBI report Bridgehunter | CR 1025E | MILL CREEK | 00.40 S of CR 800 S | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1997 | -- | 59.1 | 161.1 | Good | 92.0 | 6700197 |
NBI report | CR 25E | DOE Creek | 00.20 S of CR 1250 S | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 52.2 | 56.1 | Fair | 80.0 | 6700186 |
NBI report | CR 350N | FALLS Branch Creek | 00.50 W of 200 W | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 36.7 | 39.7 | Good | 82.7 | 6700234 |
NBI report | CR 525E | DEER Creek | 00.30 S of CR 50 S | Prestressed Box beam or girders - Multiple | -- | 1997 | -- | 49.2 | 54.5 | Fair | 89.9 | 6700117 |
NBI report | US 36 | MONOCAH CREEK | 03.19 W SR 75 | Concrete Slab (3 spans) | -- | 1998 | -- | 32.8 | 84.0 | Good | 95.8 | 011610 |
NBI report Bridgehunter | CR 250W | DEER Creek | 00.90 N of CR 900 S | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1999 | -- | 49.2 | 144.0 | Good | 92.0 | 6700158 |
NBI report Bridgehunter | CR 50N | Little WALNUT Creek | 00.10 W of CR 500 W | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1999 | -- | 69.9 | 119.1 | Good | 87.9 | 6700097 |
NBI report | CR 50N | LEATHERMAN Creek | 00.00 Int of CR 500 W | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 44.9 | 48.9 | Good | 97.9 | 6700241 |
NBI report | CR 50S | DEER Creek | 00.60 E of CR 550 E | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 49.5 | 54.5 | Good | 83.3 | 6700116 |
NBI report | US 231 | OWL CREEK | 00.73 S US 36 | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 78.7 | 81.0 | Good | 97.4 | 016050 |
NBI report | CR 725W | BYRD Branch CREEK | 00.40 N of CR 900 N | Concrete Frame (2 spans) | -- | 2000 | -- | 14.4 | 32.5 | Good | 99.0 | 6700011 |
NBI report | CR 1000N | BRANCH OF RAMP CREEK | 00.20 W CR 400 W | Metal Culvert | -- | 2001 | -- | 23.0 | 28.9 | Good | 90.5 | 6700252 |
NBI report | CR 1200S | Branch of MILL Creek | 00.10 W of CR 600 E | Metal Culvert | -- | 2002 | -- | 22.0 | 37.1 | Good | 100.0 | 6700172 |
NBI report | CR 200S | CSX RR | 00.10 W of JACKSON | Concrete Slab | -- | 2002 | -- | 38.7 | 42.0 | Good | 97.0 | 6700220 |
NBI report | CR 900N | BYRD Branch CREEK | 00.50 W of CR 775 W | Steel Stringer/Multi-beam or girder | -- | 2002 | -- | 35.1 | 38.1 | Good | 92.5 | 6700015 |
NBI report | CR 250S | Branch of SNAKE Creek | 00.80 W of CR 600 W | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 53.2 | 57.1 | Good | 91.0 | 6700101 |
NBI report | CR 325N | DRY Branch Creek | 00.20 E of CR 100 E | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 40.0 | 45.3 | Good | 89.0 | 6700066 |
NBI report | CR 500N | Branch LITTLE WALNUT Cr | 00.10 W of CR 725 W | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 21.0 | 24.0 | Good | 86.5 | 6700242 |
NBI report | CR 75S | LONG BRANCH CREEK | 00.01 W of CR 725 W | Metal Culvert (2 spans) | -- | 2003 | -- | 24.0 | 52.2 | Good | 97.9 | 6700094 |
NBI report | CR 775E | Branch of BELLE UNION Cr | 00.20 S of CR 550 S | Metal Culvert | -- | 2003 | -- | 20.3 | 20.3 | Good | 100.0 | 6700170 |
NBI report | CR 800E | Branch of BELLE UNION Cr | 00.10 N of CR 600 S | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 26.9 | 30.8 | Good | 90.0 | 6700243 |
NBI report | CR 900E | CLEAR Creek | 00.20 N of US 36 | Prestressed Box beam or girders - Multiple | -- | 2003 | -- | 49.9 | 56.1 | Fair | 92.0 | 6700031 |
NBI report Bridgehunter | DEVIL BACKBONE Rd | Little DEER Creek | 00.60 NW of US 40 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 54.1 | 57.7 | Good | 92.5 | 6700132 |
NBI report Bridgehunter | US 36 | BIG WALNUT CREEK | 05.64 E US 231 | Prestressed Tee beam (3 spans) | -- | 2003 | -- | 120.1 | 316.9 | Fair | 92.8 | 011580 |
NBI report | CR 100N | DEER CREEK | 00.20 E of CR 750 E | Prestressed Box beam or girders - Multiple | -- | 2004 | -- | 38.7 | 43.3 | Fair | 87.9 | 6700112 |
NBI report Bridgehunter | CR 200N | SNYDER Branch Creek | 00.60 W of CR 100 E | Metal Culvert | -- | 2004 | -- | 21.7 | 22.0 | Good | 100.0 | 6700035 |
NBI report | CR 400N | BLEDSOE Branch Creek | 00.20 W of CR 300 E | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 49.9 | 53.2 | Good | 93.5 | 6700063 |
NBI report | CR 550E | Branch of DEER Creek | 00.40 N of CR 50 S | Prestressed Box beam or girders - Multiple | -- | 2004 | -- | 48.9 | 50.5 | Fair | 79.7 | 6700052 |
NBI report | CR 625W | BIG WALNUT Creek | 00.30 N of US 40 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 87.9 | 264.1 | Good | 97.4 | 6700244 |
NBI report | CR 825E | Branch of BELLE UNION Cr | 00.30 S of CR 600 S | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 33.8 | 38.1 | Good | 88.9 | 6700213 |
NBI report | CR 1100S | CHURCH Creek | 00.60 E of CR 900 W | Steel Stringer/Multi-beam or girder | -- | 2005 | -- | 33.8 | 35.1 | Good | 92.5 | 6700142 |
NBI report Bridgehunter | CR 550W | RAMP Creek | 00.50 S of CR 1000 N | Steel Stringer/Multi-beam or girder | -- | 2006 | -- | 82.4 | 87.9 | Good | 93.4 | 6700010 |
NBI report | CR 600E | PLUM Creek | 00.30 S of US 36 | Prestressed Box beam or girders - Multiple | -- | 2006 | -- | 55.1 | 61.0 | Good | 86.4 | 6700047 |
NBI report | US 231 | FALLS BRANCH | 02.61 S US 36 | Concrete Culvert | -- | 2006 | -- | 26.6 | 27.9 | Good | 84.9 | 016045 |
NBI report | CR 150N | LEATHERMAN Creek | 00.01 W of CR 625 W | Steel Stringer/Multi-beam or girder | -- | 2007 | -- | 33.8 | 37.4 | Good | 92.5 | 6700247 |
NBI report | CR 500W | LONG Branch Creek | 00.60 S of CR 100 S | Steel Stringer/Multi-beam or girder | -- | 2007 | -- | 48.2 | 51.8 | Good | 87.9 | 6700248 |
NBI report | CR 575S | DESEESE Creek | 00.40 S of CR 550 S | Prestressed Box beam or girders - Multiple | -- | 2007 | -- | 67.9 | 70.5 | Good | 88.9 | 6700240 |
NBI report | CR 725E | CLEAR Creek | 00.20 S of CR 600 N | Prestressed Box beam or girders - Multiple | -- | 2007 | -- | 60.4 | 64.6 | Fair | 97.8 | 6700245 |
NBI report | US 231 | TRIB BIG RACCOON CREEK | 00.60 S of S JCT SR 236 | Concrete Culvert | -- | 2007 | -- | 22.3 | 24.0 | Good | 98.5 | 016065 |
NBI report | CR 1300S/LOUISVILL | MILL CREEK | 00.60 W of CR 700 E | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2008 | -- | 100.1 | 299.9 | Good | 99.9 | 6700249 |
NBI report | CR 250N | Little WALNUT Creek | 00.02 E of CR 550 W | Steel Stringer/Multi-beam or girder | -- | 2008 | -- | 74.2 | 77.1 | Good | 92.5 | 6700246 |
NBI report | CR 775W | BYRD BRANCH CREEK | 00.40 N of CR 900 N | Prestressed Box beam or girders - Multiple | -- | 2009 | -- | 28.5 | 31.8 | Fair | 90.0 | 6700253 |
NBI report | I-70 | BRANCH OF CROYS CREEK | 06.55 W SR 243 | Concrete Culvert | -- | 2009 | -- | 29.9 | 32.5 | Good | 85.0 | 041504 |
NBI report | CR 425E | LICK CREEK | 00.50 N of SR 236 | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 21.7 | 26.2 | Fair | 91.0 | 6700251 |
NBI report | DNR SERVICE ROAD | DEWEESE BRANCH | 00.95 N US 40 | Concrete Culvert | -- | 2011 | -- | 28.2 | 30.2 | Good | 88.4 | 079642 |
NBI report | CR 1050N | BIG RACCOON CREEK | 00.01 E of CR 600 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2012 | -- | 86.0 | 219.5 | Good | 99.9 | 6700255 |
NBI report | CR 25E | BIG WALNUT CREEK | 00.40 S CR 125 N | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2012 | -- | 100.1 | 261.8 | Good | 99.9 | 6700256 |
NBI report | CR 550S | BIG WALNUT CREEK | 00.10 E CR 500 W | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2014 | -- | 128.6 | 128.6 | Good | 99.8 | 6700257 |
NBI report | CR 850N | SOUTH RAMP CREEK | 00.50 W of CR 100 E | Steel Stringer/Multi-beam or girder | -- | 2015 | -- | 26.9 | 32.2 | Good | 89.0 | 6700259 |
NBI report | DUNBAR RD | BRANCH BIG WALNUT CR | 01.00 E CR 300 W | Prestressed Box Beam or girders - Single or Spread | -- | 2015 | -- | 62.0 | 64.6 | Good | 97.3 | 6700258 |
NBI report | CR 100E | BIG WALNUT CREEK | 01.20 N of ALBION POND RD | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 2016 | -- | 95.1 | 215.6 | Good | 99.9 | 6700263 |
NBI report | CR 25W | South RAMP Creek | 00.30 S of CR 900 N | Steel Stringer/Multi-beam or girder | -- | 2016 | -- | 41.0 | 44.9 | Good | 92.5 | 6700261 |
NBI report | CR 650E | BIG WALNUT CREEK | 00.70 S of CR 1200 N | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 2016 | -- | 74.8 | 224.4 | Good | 100.0 | 6700264 |
NBI report | CR 850N | PETERS Creek | 00.20 E of CR 400 W | Steel Stringer/Multi-beam or girder | -- | 2016 | -- | 28.5 | 31.8 | Good | 92.5 | 6700260 |
NBI report | CR 1200S | BR CROYS CREEK | 00.30 E of CR 900 W | Steel Stringer/Multi-beam or girder | -- | 2017 | -- | 21.7 | 26.6 | Good | 85.5 | 6700268 |
NBI report | CR 525W | LEATHERMAN Creek | 00.30 N of CR 50 N | Steel Stringer/Multi-beam or girder | -- | 2017 | -- | 36.1 | 40.0 | Good | 87.4 | 6700265 |
NBI report | CR 650E | LITTLE DEER CREEK | 00.20 S of SR 240 | Steel Stringer/Multi-beam or girder | -- | 2017 | -- | 26.6 | 29.9 | Good | 87.0 | 6700266 |
NBI report | CR 1050 N | BRANCH OF BIG WALNUT CRE | 00.90 W of CR 675 E | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 25.9 | 28.9 | -- | -- | 6700274 |
NBI report | CR 1125S | FERGUSON Branch | 00.70 E of MERIDIAN RD | Steel Culvert | -- | 2018 | -- | 28.2 | 28.2 | Good | 99.8 | 6700271 |
NBI report | CR 1350N | Branch of BIG RACCOON Cr | 00.20 W of CR 350 W | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 24.0 | 26.9 | -- | -- | 6700371 |
NBI report | CR 300S | BR LITTLE DEER CREEK | 00.10 E of CR 500 E | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 28.9 | 31.8 | Good | 92.5 | 6700270 |
NBI report | CR 400N | MILLER Creek | 00.10 E of CR 875 E | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 34.1 | 36.7 | Good | 93.5 | 6700269 |
NBI report | CR 425W | Branch of BIG RACCOON Cr | 00.30 N of SR 236 | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 28.9 | 31.8 | Good | 92.5 | 6700272 |
NBI report | CR 50W | CLINE CREEK | 00.20 S of CR 1400 N | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 24.0 | 26.6 | -- | -- | 6700273 |