Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | SUSPENSION BRIDGE | OHIO RIVER | SUSPENSION BR OVR OHIO RV | Steel Suspension (3 spans) | NR listed | 1867 | 1955 | 1057.1 | 2162.2 | Fair | 28.8 | 059B00048N |
NBI report | GARRARD STREET S | CSX RR /GARRARD MP662.4 | 75'N. OF E. 16 ST N COV. | Steel Stringer/Multi-beam or girder | -- | 1901 | -- | 60.0 | -- | -- | -- | 059R00625N |
NBI report | KY-2373 | Pleasant Run Creek | .5 MI N JCT Anderson RD | Prestressed Box beam or girders - Multiple | -- | 1901 | -- | 21.0 | 30.8 | Poor | 48.9 | 059B00117N |
NBI report | 47TH ST | CSX RR OVER 47TH ST (COV | AT JCT 47 TH. ST. | Steel Stringer/Multi-beam or girder | -- | 1911 | -- | 49.9 | -- | -- | -- | 059R00623N |
NBI report | OLD KY-17 | CSX RR OVER OLD KY 17 | .5 MI N OF S-JCT NEW KY17 | Steel Stringer/Multi-beam or girder | -- | 1913 | -- | 6.9 | -- | -- | -- | 059R00607N |
NBI report | PERSHING AVE | CSX RR OVER PERSHING AVE | @ CRAIG AVE. | Concrete Slab | -- | 1919 | -- | 24.0 | -- | -- | -- | 059R00626N |
NBI report | WEST 6TH ST | CSX RAILROAD | @ W. 6TH & JOHNSONST | Concrete Slab | -- | 1919 | -- | 2.3 | -- | -- | -- | 059R00622N |
NBI report | WEST 7TH ST | CSX RR OVER CRAIG ST | BETWEEN 6 & 7 STREETS | Concrete Slab | -- | 1919 | -- | 18.0 | -- | -- | -- | 059R00627N |
NBI report Bridgehunter | ERNEST BRIDGE DR | CSX RAILROAD | .75 E KY 177 | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 54.1 | 116.1 | Poor | 24.5 | 059C00048N |
NBI report Bridgehunter | 11TH STREET | CSX RAILROAD | 11TH ST E OF RUSSELL ST | Steel Girder and floorbeam system | Closed | 1927 | -- | 86.9 | 89.9 | Poor | 19.6 | 059B00083N |
NBI report | CSX RR | GREENUP AVENUE | KY17(GREENUP ST)NEAR 17TH | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 47.9 | -- | -- | -- | 059R00606N |
NBI report | CSX RR | SCOTT BOULEVARD | SCOTT ST NEAR 17TH ST | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 39.0 | -- | -- | -- | 059R00608N |
NBI report | EAST 15TH STREET | CSX RR OVER 15TH ST | .5 MI-NE JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 51.8 | -- | -- | -- | 059R00630N |
NBI report | MARYLAND AVE | MARYLAND AVE UNDER CSX R | .5 MI-NE JCT KY17 | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 9.2 | -- | -- | -- | 059R00631N |
NBI report | PATTON ST | CSX RR OVER PATTON ST | .5 MI-NE-JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 29.9 | -- | -- | -- | 059R00629N |
NBI report | AMSTERDAM EAST RD | NS (SOUTHERN) RAILROAD | 800 FT E CR 5316 | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 58.1 | -- | -- | -- | 059R00628N |
NBI report | CAROLINE STREET | CSX RR @ CAROLINE ST (CO | CAROLINE ST NR 36TH ST | Concrete Tee beam | -- | 1930 | -- | 19.0 | -- | -- | -- | 059R00619N |
NBI report | CODY RD | CSX RR OVR-BANKLICK CK&C | 1.3 MI- W JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 66.9 | -- | -- | -- | 059R00632N |
NBI report | CSX RAILROAD | 3RD STREET | APPRCH TO CLAY BAILEY BR | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 1.0 | -- | -- | -- | 059R00602N |
NBI report | CSX RAILROAD | 4TH, 5TH, AND MAIN STS. | MAIN ST BTWN 4TH&5TH STS | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 60.0 | -- | -- | -- | 059R00610N |
NBI report | CSX RR | JAMES AVENUE (30TH ST) | .5 MI-S.JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 64.0 | -- | -- | -- | 059R00604N |
NBI report | EAST 40TH ST | CSX RAILROAD OVER 40TH S | BETWN GLEN & HUNT'NTON | Concrete Slab | -- | 1930 | -- | 27.9 | -- | -- | -- | 059R00624N |
NBI report | EAST 8TH STREET | CSX RR OVER 8TH ST (COV) | 8TH ST NR RUSSELL ST | Concrete Slab | -- | 1930 | -- | 15.1 | -- | -- | -- | 059R00621N |
NBI report | MADISON AVENUE | CSX RR @ MADISON ST (COV | MADISON ST NR 17TH ST | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 58.7 | -- | -- | -- | 059R00618N |
NBI report | NS (SOU) SYSTEM | KY 8 (RIVER ROAD) | SO.RR OVR ELM ST-LUDLOW | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 44.9 | -- | -- | -- | 059R00603N |
NBI report | NS (SOU) SYSTEM | SLEEPY HOLLOW ROAD | .5 MI. SE.-JCT KY 8 | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 1.0 | -- | -- | -- | 059R00611N |
NBI report | RIVER ROAD/PIKE ST | LUDLOW LAGOON OVERFLOW | .25 MI SW OF JCT KY 1072 | Concrete Culvert | -- | 1930 | -- | 20.0 | 23.0 | Good | 95.2 | 059B00013N |
NBI report | RUSSELL STREET | CSX RR @ RUSSELL ST (COV | RUSSELL ST NR PIKE ST | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 49.9 | -- | -- | -- | 059R00620N |
NBI report | WEST PIKE STREET | CSX RR @ PIKE ST (COV) | PIKE ST NR RUSSELL ST | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 49.9 | -- | -- | -- | 059R00617N |
NBI report | BAKEWELL STREET N | CSX RR OVR BAKEWELL ST | OVER NORTH END BAKEWELL | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 83.3 | -- | -- | -- | 059R00633N |
NBI report | KY-177 | STEEP CREEK | .9 MI S OF JCT KY 2044 | Concrete Culvert (2 spans) | -- | 1932 | -- | 12.1 | 26.9 | Fair | 78.2 | 059B00010N |
NBI report Bridgehunter | KY-177 | BOWMAN CREEK | 1.3 MI N OF JCT KY 2042 | Concrete Tee beam (3 spans) | -- | 1932 | -- | 49.9 | 162.1 | Fair | 67.8 | 059B00011N |
NBI report Bridgehunter | 4TH STREET | LICKING RIVER | 4TH ST BR OVER LICKING RV | Steel Truss - Thru | NR possible | 1936 | -- | 250.0 | 1002.0 | Fair | 42.7 | 059B00037N |
NBI report | NS (SOU) SYSTEM | DIXIE HIGHWAY | .1 MI NE OF JCT KY 236 | Steel Girder and floorbeam system | -- | 1936 | -- | 54.1 | -- | -- | -- | 059R00609N |
NBI report Bridgehunter | GARVEY AVENUE | NS (CNO&TP) SYSTEM | 3-BLOCKS SOUTH OF US. 25 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1940 | -- | 37.1 | 100.4 | Poor | 43.3 | 059C00030N |
NBI report | KY 1930 | DECORSEY CREEK | 0.2 MI. E OF JCT KY 1930 | Concrete Culvert | -- | 1943 | -- | 39.7 | 39.7 | Fair | 79.4 | 059B00114N |
NBI report | DONALDSON ROAD | VIOX CREEK | .25 MI WEST OF I-75 | Concrete Culvert (2 spans) | -- | 1943 | 1961 | 16.1 | 34.8 | Fair | 83.5 | 059B00034N |
NBI report Bridgehunter | ALEXANDER RD | CSX RAILROAD | 1.4 MI N OF JCT KY 177 | Wood Stringer/Multi-beam or girder (6 spans) | Closed | 1950 | -- | 25.9 | 95.1 | Poor | 19.7 | 059C00011N |
NBI report Bridgehunter | WEST 15TH STREET | CSX RAILROAD | EAST OF RUSSEL ST.ON 15TH | Steel Girder and floorbeam system (3 spans) | Closed | 1950 | -- | 107.0 | 179.1 | -- | 50.0 | 059C00029N |
NBI report | OLD TURKEYFOOT RD | BULLOCK PEN CREEK | .25 MI N JCT KY 1303 | Concrete Culvert (2 spans) | -- | 1952 | -- | 14.1 | 30.8 | Fair | 58.6 | 059B00020N |
NBI report | KY-1501 | WAYMANS BR. | .30 MI EAST OF JCT KY 17 | Concrete Culvert (2 spans) | -- | 1954 | -- | 12.1 | 26.9 | Fair | 70.3 | 059B00022N |
NBI report | KY-177 | CRUISES CREEK | 1.0 MI NOR. OF JCT KY 14 | Concrete Tee beam (3 spans) | -- | 1954 | -- | 44.9 | 144.0 | Fair | 51.1 | 059B00012N |
NBI report | RICHARDSON ROAD | CSX RR OVR RICHRDSN RD N | .5 MI.-W.-JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1956 | -- | 1.0 | -- | -- | -- | 059R00613N |
NBI report | BROMLEY-CRESCENT S | Pleasant Run Creek | .8 miles S of KY 8 | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 55.1 | 58.4 | Fair | 69.9 | 059B00119N |
NBI report | I-75 | NINTH ST IN COVINGTON | NBL .4M S OF 5TH ST NTRCH | Concrete Tee beam (3 spans) | -- | 1960 | -- | 49.9 | 159.1 | Fair | 97.0 | 059B00038R |
NBI report | I-75 | US25,KY1120,(11TH,12TH,L | NBL-.3M N-JEFFERSON ST OP | Concrete Tee beam (3 spans) | -- | 1960 | -- | 80.1 | 684.1 | Fair | 82.0 | 059B00044R |
NBI report | I-75 NC | NINTH ST IN COVINGTON | SBL .4M S OF 5TH ST NTRCH | Concrete Tee beam (3 spans) | -- | 1960 | -- | 49.9 | 159.1 | Fair | 98.0 | 059B00038L |
NBI report | I-75 NC | 11TH-12TH-LEWIS IN CVNGT | SBL-.3M N-JEFFERSON ST OP | Concrete Tee beam (3 spans) | -- | 1960 | -- | 80.1 | 684.1 | Fair | 82.0 | 059B00044L |
NBI report | KY-2373 | PLEASANT RUN CREEK | S @JCT CR 5317 | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 28.9 | 33.5 | Fair | 46.4 | 059B00118N |
NBI report | PARKWAY AVE | PARKWAY ST OVER KY8 | PARKWAY AVE OVR HIGH ST | Prestressed Box beam or girders - Multiple | -- | 1960 | -- | 94.2 | 97.1 | Fair | 18.9 | 059C00037N |
NBI report | I-75 NC | RIVARD DR IN FT WRIGHT | SBL .75 MI NE OF US 25 OP | Concrete Tee beam (3 spans) | -- | 1960 | 1992 | 49.9 | 159.1 | Fair | 93.0 | 059B00043L |
NBI report | KYLES LANE | I-75 | .2 MI S OF JCT US 25-42 | Concrete Tee beam (4 spans) | -- | 1960 | 1992 | 75.1 | 253.9 | Fair | 86.0 | 059B00047N |
NBI report | I-75 | RIVARD DR IN FT WRIGHT | NBL .75 MI NE OF US 25 OP | Concrete Tee beam (3 spans) | -- | 1960 | 1998 | 49.9 | 159.1 | Fair | 93.0 | 059B00043R |
NBI report | HARTMAN RD | VIOX CREEK | 764 FT NE OF KY236 | Concrete Culvert (2 spans) | -- | 1961 | -- | 12.1 | 27.9 | Poor | 72.6 | 059C00071N |
NBI report | 5TH ST/SB I75 RMP | 4TH ST RAMP TO SB I-75 | SB EXT RMP @5TH ST NTRCH | Concrete Tee beam | -- | 1963 | -- | 30.8 | 62.0 | Fair | 98.2 | 059B00039N |
NBI report | I-75 | OHIO RIVER | BRENT SPENCE BR OVER OHIO | Steel Truss - Thru (3 spans) | -- | 1963 | -- | 830.4 | 1736.6 | Fair | 47.0 | 059B00046N |
NBI report | I-75 NC | 3RD-4TH-5TH STS COVINGTO | APPROACH TO BRENT SPENCE | Steel Stringer/Multi-beam or girder | -- | 1963 | 2007 | 75.1 | 3133.0 | Fair | 49.0 | 059B00040N |
NBI report | BUTTERMILK PIKE | NS (CNO&TP) SYSTEM | .25 MI N.W. OF I-75 OP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 75.1 | 183.1 | Fair | 96.7 | 059B00029N |
NBI report | KLETTE RD/OLD DECO | DECOURSEY CREEK | .85 MI SOU. OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1965 | -- | 30.8 | 42.0 | Fair | 65.1 | 059B00033N |
NBI report | KY-2043 | CRUISES CREEK | 2.0 MI SOU. OF JCT KY 16 | Prestressed Box beam or girders - Multiple | -- | 1965 | -- | 66.9 | 69.9 | Fair | 68.8 | 059B00023N |
NBI report | KY-2045 | BRUSHY CREEK | .3 MI N OF JCT KY 1303 | Prestressed Box beam or girders - Multiple | -- | 1965 | -- | 28.9 | 34.1 | Fair | 40.7 | 059B00025N |
NBI report | NS (CNO&TP) SY | INDUSTRIAL ROAD KY-1829 | 1 MI W-KY1303 NR BOONE CL | Steel Stringer/Multi-beam or girder | -- | 1965 | -- | 69.9 | -- | -- | -- | 059B00001N |
NBI report | PED. OP AT 5TH ST | NB I75 EXT RMP TO 5TH ST | PED. OP 5TH ST INTERCHANG | Prestressed Box beam or girders - Multiple | -- | 1968 | -- | 86.0 | -- | -- | -- | 059B00041N |
NBI report | ALEXANDER RD | UNNAMED STREAM | .6 MI N OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 61.0 | 63.0 | Fair | 49.3 | 059C00010N |
NBI report | BRISTOW ROAD/SHAW | BRUSHY CREEK | .1 MI S OF JCT KY 2045 | Concrete Culvert | -- | 1970 | -- | 23.0 | 24.9 | Good | 80.4 | 059B00032N |
NBI report | BUFFINGTON ROAD | NS (CNO&TP) SYSTEM | 0.75 MI NE OF JCT US 25 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 58.1 | 62.0 | Fair | 78.1 | 059C00025N |
NBI report | CASE RD | STEEP CREEK | .1 MI W OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 51.8 | 54.1 | Fair | 69.0 | 059C00005N |
NBI report | CR-1061 | CRUISES CREEK | 300' N OF JCT KY 14 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1970 | -- | 47.9 | 94.2 | Fair | 77.3 | 059C00073N |
NBI report | CR-1061 | TRACE RUN | 1.8 MI NW OF JCT KY 14 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 77.1 | 79.1 | Fair | 55.5 | 059C00074N |
NBI report | ERLANGER ROAD N | UNNAMED STREAM | .1 MI N OF JCT KY 2978 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 60.0 | 64.0 | Fair | 68.1 | 059C00027N |
NBI report | GRAND AVENUE | TRIB. BANKLICK CK | .1 MI W OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 25.9 | 30.8 | Fair | 77.1 | 059C00032N |
NBI report | I-275 | DRY CREEK | .75 MI WEST OF I-75 | Concrete Culvert | -- | 1970 | -- | 27.9 | 30.8 | Good | 70.0 | 059B00065N |
NBI report | I-275 EB | ERLANGER SERVICE ROAD | EBL @ BOONE CO. LN. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 57.1 | 150.9 | Good | 96.0 | 059B00064R |
NBI report | I-275 WB | ERLANGER SERVICE ROAD | WBL @ BOONE CO. LN. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 60.0 | 175.9 | Good | 96.0 | 059B00064L |
NBI report | INDEPENDENCE STATI | BANKLICK CREEK | 1.6 MI NW OF JCT KY 17 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1970 | -- | 48.9 | 102.0 | Fair | 57.2 | 059C00055N |
NBI report | INDEPENDENCE STATI | BRUSHY FK OF BANKLICK CR | .76 MI NW OF JCT KY 17 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 51.8 | 54.1 | Fair | 75.7 | 059C00056N |
NBI report | KENTON STATION RD | BOWMAN CREEK | .5 MI NW OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 48.6 | 50.5 | Fair | 81.3 | 059C00013N |
NBI report | KENTON STATION RD | VANCE BRANCH | .65 MI NW OF JCT CR 5112 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 32.2 | 37.4 | Fair | 66.2 | 059C00014N |
NBI report | KY-14 | LITTLE CRUISES CREEK | 1.6 MI N.W. OF JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 45.9 | 49.9 | Fair | 66.2 | 059B00031N |
NBI report | MAHER RD | BR OF BANKLICK CREEK | .65 MI W OF JCT KY 2043 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 28.9 | 32.2 | Fair | 76.8 | 059C00017N |
NBI report | MANN RD | STEEP CREEK | 100' E OF JCT CR 5104 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 51.8 | 54.1 | Fair | 85.9 | 059C00006N |
NBI report | MARTIN RD | BOWMAN CREEK | .2 MI W OF JCT CR 5132 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 47.9 | 49.9 | Fair | 76.5 | 059C00015N |
NBI report | MENEFEE RD | NO.FK. GRASSY CREEK | .1 MI S-KY2046&N-GRANT CL | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 58.1 | 60.0 | Fair | 64.0 | 059C00033N |
NBI report | OLD NARROWS RD | BULLOCK PEN CREEK | .2 MI E OF JCT KY 1303 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 58.1 | 61.0 | Fair | 44.6 | 059C00034N |
NBI report | PORTER RD | DECOURSEY CREEK | 50 FT SE OF N-JCT KY 177 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 86.9 | 90.9 | Fair | 86.0 | 059C00002N |
NBI report | RECTOR RD | BOWMAN CREEK | 100' W OF JCT CR 5132 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 86.0 | 88.9 | Fair | 65.4 | 059C00007N |
NBI report | WEST 26TH ST | CSX RAILROAD | 100FT W OF KY 17 | Prestressed Box beam or girders - Multiple | -- | 1970 | -- | 107.0 | 110.2 | Good | 51.1 | 059C00043N |
NBI report | CRUISE CREEK RD | LITTLE CRUISES CREEK | 1.3 MI SW OF JCT KY 14 | Prestressed Box beam or girders - Multiple | -- | 1970 | 2013 | 30.8 | 33.5 | Fair | 65.9 | 059C00012N |
NBI report | I-275 EB | I-75 N&S-RAMPS G-D | EB-275 MAINLINE@I75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 118.1 | 415.0 | Fair | 77.0 | 059B00054R |
NBI report | I-275 WB | I-75 N&S-RAMPS G-D | WBI275@I75 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 118.1 | 413.1 | Fair | 73.9 | 059B00054L |
NBI report | I-75 RAMP | I275-I75-G&D RAMPS | EB I275 TO NB I75 RMP-LVL | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1971 | -- | 158.1 | 894.4 | Fair | 70.0 | 059B00055N |
NBI report | I-75 RAMP | I275-I75-G&D RAMPS | WB I275 TO SB I75 RMP-LVL | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1971 | -- | 158.1 | 806.8 | Fair | 65.0 | 059B00056N |
NBI report | I-75 | I275 E&W-RAMPS D-G | NB MAINLINE I75 @I275 NTR | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1994 | 71.9 | 255.9 | Fair | 96.8 | 059B00053R |
NBI report | I-75 NC | I275 E&W-RAMPS D-G | SB MAINLINE I75 @I275 NTR | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1994 | 71.9 | 255.9 | Fair | 96.5 | 059B00053L |
NBI report | I-275 EB | CSX RR-KY 177-LICKNG RVR | EBL @CAMPBELL CO.LN. | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1972 | -- | 220.2 | 1527.0 | Good | 92.0 | 059B00052R |
NBI report | ERLANGER-CRESCENT | I-275 & RAMPS C,E,F | 1 MI NE OF JCT KY 236 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1973 | -- | 127.0 | 358.0 | Fair | 78.7 | 059B00057N |
NBI report | I-275 EB | US 25 & US 42 | EBL OVER US 25 INTERCHANG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 86.9 | 242.1 | Fair | 98.0 | 059B00059R |
NBI report | I-275 RAMP | US 25 & US 42 | RMPS A&C OVR US 25 NTRCH | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 89.9 | 246.1 | Fair | 88.2 | 059B00060N |
NBI report | I-275 RAMP | RAMP F (EB ENTR.RAMP) | .1 MI E OF US 25-42 NTRCH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1973 | -- | 115.2 | 285.1 | Fair | 88.1 | 059B00061N |
NBI report | I-275 WB | CSX RR-KY 177-LICKNG RVR | WBL @CAMPBELL CO LN. | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1973 | -- | 220.2 | 1527.0 | Fair | 92.0 | 059B00052L |
NBI report | I-275 WB | US 25 & US 42 | WBL OVER US 25 INTERCHANG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 86.9 | 248.0 | Fair | 96.0 | 059B00059L |
NBI report | NS (CNO&TP) SYSTEM | I-275 | .4 MI W-US 25&42 NTRCH | Steel Stringer/Multi-beam or girder | -- | 1973 | -- | 10.5 | -- | -- | -- | 059B00058N |
NBI report | TAYLOR MILL ROAD | I 275 | 1.6 MI S OF JCT KY 177 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 116.1 | 232.0 | Fair | 91.4 | 059B00050N |
NBI report | I-275 EB | HORSEBRANCH ROAD | EBL .75 WEST OF KY 17 OP | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1974 | -- | 60.0 | 126.0 | Fair | 89.0 | 059B00062R |
NBI report | I-275 WB | HORSEBRANCH ROAD | WBL .75 WEST OF KY 17 OP | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1974 | -- | 65.0 | 151.9 | Fair | 89.0 | 059B00062L |
NBI report | MADISON PIKE NC | CSX RR & BANKLICK CR | SBL S-@N-JCT OLD KY 17 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1974 | -- | 71.9 | 511.2 | Good | 100.0 | 059B00067L |
NBI report | MADISON ROAD/MADIS | HORSE BRANCH CREEK | AT JCT KY 371 | Concrete Culvert | -- | 1974 | -- | 28.2 | 28.2 | Fair | 72.0 | 059B00066N |
NBI report | MADISON ROAD/MADIS | CSX RR & BANKLICK CR | NBL S-@N-JCT OLD KY 17 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1974 | -- | 71.9 | 511.2 | Good | 100.0 | 059B00067R |
NBI report | TURKEYFOOT ROAD | I 275 | .6 MI S OF JCT US 25-42 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | -- | 107.9 | 283.2 | Fair | 97.6 | 059B00051N |
NBI report | US25/US42/US127 | OHIO RIVER | CLAY WADE BAILEY OVR OHIO | Steel Truss - Thru (3 spans) | -- | 1974 | -- | 674.9 | 2209.4 | Poor | 59.6 | 059B00049N |
NBI report | ROGERS RD | BR.OF DRY CREEK | 0.4MI.S.OF BUTTERMILK PK | Prestressed Box beam or girders - Multiple | -- | 1975 | -- | 22.0 | 25.9 | Fair | 62.6 | 059C00039N |
NBI report | WEBSTER RD N | BANKLICK CREEK | 0.1 Mile West of Jct.1829 | Prestressed Box beam or girders - Multiple | -- | 1975 | -- | 57.1 | 60.0 | Fair | 85.0 | 059C00065N |
NBI report | DECOURSEY ROAD | BANKLICK CREEK | .80 MI NOR. OF I-275 OP | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1976 | -- | 134.8 | 350.1 | Good | 82.6 | 059B00071N |
NBI report | I-275 EB | CSX RR-KY 17-BANKLICK CR | EBL OVR KY17&BANK LICK CR | Steel Stringer/Multi-beam or girder (11 spans) | -- | 1977 | -- | 228.0 | 1695.0 | Fair | 88.0 | 059B00063R |
NBI report | I-275 WB | CSX RR-KY 17-BANKLICK CR | WBL OVR KY17&BANK LICK CR | Steel Stringer/Multi-beam or girder (11 spans) | -- | 1977 | -- | 228.0 | 1695.0 | Fair | 88.0 | 059B00063L |
NBI report | I-75 RAMP | RAMP DONALDSON TO I-75 | RMP E-NB I75 TO I275 E&W | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 104.0 | 107.9 | Fair | 85.0 | 059B00072N |
NBI report | KY-17 | CRUISES CREEK | .70 MI NOR. OF JCT KY 14 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 80.1 | 207.0 | Good | 92.8 | 059B00073N |
NBI report | KY-536 | LICKING RIVER | .30 MI EAST OF JCT KY 177 | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1978 | -- | 180.1 | 664.1 | Fair | 87.7 | 059B00070N |
NBI report | KY-3035 | FOWLERCREEK | .1 MI. S. JCT. KY 1486 | Prestressed Stringer/Multi-beam or girder | -- | 1981 | -- | 57.1 | 62.0 | Good | 99.7 | 059B00074N |
NBI report | MAHER RD | BANK LICK CREEK | 50 FT WEST -KY 2043 | Prestressed Box beam or girders - Multiple | -- | 1981 | -- | 41.3 | 44.3 | Fair | 78.9 | 059C00045N |
NBI report | OAK ST | LAGON CREEK | 1 BLOCK S. KY 8 | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 38.1 | 39.7 | Fair | 82.0 | 059C00049N |
NBI report | OLD KY-17 | BANKLICK CREEK | .1 MI. NW-KY 17 | Prestressed Box beam or girders - Multiple | -- | 1982 | -- | 96.1 | 105.0 | Fair | 84.3 | 059C00046N |
NBI report | KY-1120 (12TH ST) | CSX RR | 400.FT E. RUSSELL ST. | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 107.0 | 546.9 | Fair | 66.5 | 059B00081L |
NBI report | KY-3035 | WAYMAN BRANCH | .05 MI S OF JCT KY 1501 | Prestressed Box Beam or girders - Single or Spread | -- | 1983 | -- | 32.2 | 34.1 | Good | 99.9 | 059B00075N |
NBI report | SHINKLE ROAD | DRY CREEK | 0.4 MI N Of Look Out RD | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 27.9 | 30.2 | Fair | 81.6 | 059C00067N |
NBI report | WINSTON AVENUE | BANKLICK CREEK | .80 MI SW OF JCT KY 177 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 96.1 | 280.9 | Fair | 98.0 | 059B00082N |
NBI report | KENTON LANDS RD | N5(CNO&TP) SYSTEM | 2000'WEST JCT US 25 | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 47.9 | -- | -- | -- | 059C00051N |
NBI report | DECOURSEY ROAD | DECOURSEY CREEK | .1 MI N.W.-KY 204 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 55.1 | 165.0 | Good | 97.1 | 059B00086N |
NBI report | SUSP. BRIDGE APPR | SECOND STREET | 500'S. SUSPENSION BRIDGE | Prestressed Box beam or girders - Multiple | -- | 1992 | -- | 51.8 | 51.8 | Fair | 91.8 | 059B00085N |
NBI report | CSX RAILROAD | HOWARD LITZLER RD. | 1500' EAST JCT KY 17 | Steel Stringer/Multi-beam or girder | -- | 1993 | -- | 66.9 | -- | -- | -- | 059B00092N |
NBI report | CSX RAILROAD | WEST 43RD STREET | 750' SOU. JCT 35TH ST | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 41.0 | -- | -- | -- | 059C00052N |
NBI report | I-75 | KY 2373 (CRESCENT SP. RD | 941' WEST JCT (NO &TP RR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 53.2 | 157.2 | Good | 98.0 | 059B00094R |
NBI report | I-75 | NS (CNO&TP) SYSTEM | .5 MI SW JCT KY NBL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 100.1 | 257.9 | Good | 98.0 | 059B00095R |
NBI report | I-75 | BEECHWOOD ROAD | .25 MI N JCT KY 371 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1993 | -- | 54.1 | 158.1 | Good | 89.0 | 059B00096R |
NBI report | I-75 NC | KY 2373 (CRESCENT SPRING | 941' WEST JCT (NO &TP RR | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 53.2 | 157.2 | Good | 93.0 | 059B00094L |
NBI report | I-75 NC | NS (CNO&TP) SYSTEM | .5 MI SW JCT KY NBL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 100.1 | 257.9 | Good | 98.0 | 059B00095L |
NBI report | I-75 NC | BEECHWOOD ROAD | .25 MI N JCT KY 371 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1993 | -- | 54.1 | 163.1 | Good | 89.0 | 059B00096L |
NBI report | I-75 RAMP | PIKE ST-ON RMP TO I-75 N | I-75 NB-EXIT E TO 5TH ST | Prestressed Stringer/Multi-beam or girder | -- | 1993 | -- | 53.2 | 85.0 | Fair | 83.0 | 059B00087N |
NBI report | I-75 RAMP | 9TH ST (I-75NB) RAMP'G' | I75 NB TO 5TH ST OVR 9TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 53.2 | 159.1 | Good | 83.0 | 059B00088N |
NBI report | I-75 RAMP | 9TH ST (COV) | PIKE ST TO I75NB OVR 9TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 53.2 | 159.1 | Good | 83.0 | 059B00089N |
NBI report | I-75 RAMP | 9TH ST-COVINGTON | I-75 SB-EXIT TO PIKE ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 53.2 | 160.1 | Fair | 70.0 | 059B00090N |
NBI report | WEST 43RD STREET | 43 RD STREET | 750' SOUTH JCT 35 ST | Prestressed Box beam or girders - Multiple | -- | 1993 | -- | 41.0 | -- | -- | -- | 059C00053N |
NBI report | BUTTERMILK PIKE | I-75 @ 186.347 | 1.1 MI.NW JCT US 25-42 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 97.1 | 194.9 | Good | 87.8 | 059B00097N |
NBI report | OLD TAYLOR MILL RD | HOLD BRANCH | .75 MI S JCT KY 16 | Concrete Culvert | -- | 1994 | -- | 22.0 | 43.0 | Good | 98.9 | 059C00054N |
NBI report | RICHARDSON ROAD | BANKLICK CREEK | .1 MI W. JCT KY 3035 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 58.1 | 128.9 | Good | 98.5 | 059B00093N |
NBI report | STEEP CREEK RD | STEEP CREEK | 1.7 MI SE JCT KY 2044 | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 37.1 | 80.1 | Fair | 65.6 | 059C00050N |
NBI report | RUST DR | HOLDS BRANCH CREEK | 50' MI N JCT HOLDS BR | Concrete Culvert | -- | 1997 | -- | 30.8 | 34.5 | Good | 83.5 | 059C00060N |
NBI report | WEST 19TH STREET | CSX RAILROAD | 200 FT W.-MADISON AVENUE | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1997 | -- | 62.0 | 173.6 | Good | 75.0 | 059C00059N |
NBI report | EADS RD | I-75 @ 168.676 | .2 MI.W JCT US 25 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1998 | -- | 91.9 | 247.1 | Good | 96.3 | 059B00098N |
NBI report | DIXIE HIGHWAY | I-75 @ 187.72 | 1.2 MI. NE JCT KY 371 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1999 | -- | 108.9 | 190.0 | Good | 93.9 | 059B00099N |
NBI report | I-75 | ORCHARD ROAD | .25 MI. NE JCT US 25 OP | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 58.1 | 151.9 | Good | 98.0 | 059B00100R |
NBI report | I-75 NC | ORCHARD ROAD | .25 MI. NE JCT US 25 OP | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 58.1 | 151.9 | Good | 96.0 | 059B00100L |
NBI report | MADISON ROAD/MADIS | BANKLICK CREEK | 1000' S. JCT I-275 &KY17 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1999 | -- | 80.1 | 308.1 | Good | 49.5 | 059C00062N |
NBI report | MARSHALL RD | DECOURSEY CREEK | SOUTH JCT CR 5009 | Prestressed Box beam or girders - Multiple | -- | 1999 | -- | 32.2 | 35.1 | Fair | 96.0 | 059C00061N |
NBI report | BRISTOW ROAD/SHAW | BANKLICK CREEK & CSX RR | .02 MI W. OF KY 2043 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2000 | -- | 100.1 | 435.1 | Good | 99.0 | 059B00105N |
NBI report | I-75 SB and Ramp | DONALDSON RD (KY 236) | .4 MI.NE BOONE CO LINE | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2000 | -- | 106.0 | 160.1 | Good | 80.0 | 059B00103N |
NBI report | I-75 NB | DONALDSON ROAD (KY 236) | .4 MI.NE JCT BOONE CO. | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2001 | -- | 106.0 | 160.1 | Good | 98.0 | 059B00102R |
NBI report | I-75 SB | DONALDSON RD (KY 236) | .4 MI. NE BOONE CO LINE | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2001 | -- | 106.0 | 160.1 | Good | 98.0 | 059B00102L |
NBI report | KY-1120 | LICKING RIVER CSX RR-LOW | 1.0 MI E. JCT I 75 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2001 | -- | 285.1 | 1474.2 | Good | 54.4 | 059B00104N |
NBI report | MADISON ROAD | FOWLER CREEK ROAD | .1 MI S OF FOWLER CK. RD. | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2001 | -- | 105.0 | 479.0 | Good | 100.0 | 059B00106R |
NBI report | MADISON ROAD | BANKLICK CREEK | 150 FT N OF KY 3035 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2001 | -- | 105.0 | 269.0 | Good | 98.4 | 059B00107N |
NBI report | MADISON ROAD | BANKLICK CREEK | 0.18 MI. N. OF KY 3035 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2001 | -- | 105.0 | 278.9 | Good | 92.3 | 059B00108N |
NBI report | GARVEY AVENUE | BULLOCK PEN CREEK | GARVEY RD OVER BULLOCK CK | Steel Culvert | -- | 2002 | -- | 39.0 | 39.0 | Good | 86.9 | 059C00064N |
NBI report | GLENHURST DR | TRIB. WOLF PEN BRANCH CK | .3 MI N OF JCT MAHER RD | Prestressed Box beam or girders - Multiple | -- | 2002 | -- | 36.1 | 39.0 | Good | 97.0 | 059C00069N |
NBI report | HOGREFFE RD | TRIB TO BANKLICK CREEK | .1 MI S OF JCT KY 536 | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 67.9 | 69.9 | Good | 93.5 | 059C00063N |
NBI report | MADISON PIKE NC | FOWLER CREEK ROAD | .1 MI S OF FOWLER RD | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2002 | -- | 105.0 | 479.0 | Good | 100.0 | 059B00106L |
NBI report | KY 1303 | BULLOCK PEN CREEK | 0.8 MI SOU. OF JCT KY 236 | Concrete Culvert | -- | 2006 | -- | 27.9 | 27.9 | Good | 85.0 | 059B00112N |
NBI report | KY 1072 | BANKLICK CREEK | .1 mi SE of JCT KY-17 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2007 | -- | 136.2 | 500.7 | Good | 98.0 | 059B00109N |
NBI report | KY 1072 | CSX RAILROAD | 0.3 mi SE of JCT KY-17 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2007 | -- | 99.1 | 348.1 | Good | 83.0 | 059B00110N |
NBI report | KY 2045 | FOWLER CREEK | .07 E of KY 17 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2007 | -- | 82.0 | 226.1 | Good | 100.0 | 059B00111N |
NBI report | OLD RICHARDSON RD. | BANKLICK CREEK | 0.1 MI EA OF JCT KY-1829 | Steel Stringer/Multi-beam or girder | -- | 2010 | -- | 67.9 | 76.4 | Fair | 78.0 | 059C00066N |
NBI report | PIENZA WAY | BANKLICK CREEK | .2 MILES EAST OF KY-17 | Concrete Culvert | -- | 2010 | -- | 32.2 | 32.2 | Good | 78.2 | 059C00068N |
NBI report | KY-1120 (12TH ST) | CSX RR | 400.FT E. RUSSELL ST. | Steel Stringer/Multi-beam or girder (7 spans) | -- | 2011 | -- | 102.7 | 546.9 | Good | 79.0 | 059B00113R |
NBI report | KENTUCKY 16 | HOLDS BRANCH CREEK | 2.5 MI N of KY 1505 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 2015 | -- | 125.0 | 875.0 | Good | 81.0 | 059B00115N |
NBI report | CR-1080 | Decoursey Creek | .25 MI N OF JCT KY 2044 | Steel Stringer/Multi-beam or girder | -- | 2016 | -- | 44.3 | 50.5 | Good | 87.4 | 059C00075N |
NBI report | Pelly RD | Fowler Creek | 15' S OF JCT KY 1486 | Steel Culvert | -- | 2016 | -- | 39.7 | 39.7 | Good | 99.9 | 059C00070N |