Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | TWP 187 | OKABENA CREEK | 0.3 MI S OF JCT CSAH 18 | Steel Truss - Thru (3 spans) | Closed ~ NR eligible | 1905 | 1938 | 15.1 | 44.9 | -- | 20.0 | L5245 |
NBI report | TWP 91 | N FK JACK CREEK | 1.1 MI E OF JCT CR 61 | Steel Stringer/Multi-beam or girder | -- | 1906 | -- | 26.9 | 31.8 | Fair | 63.7 | L5200 |
NBI report | CSAH 18 | CO DITCH # 3 | 0.9 MI W OF JCT CSAH 9 | Steel Stringer/Multi-beam or girder | -- | 1916 | -- | 26.6 | 28.9 | Fair | 68.2 | 89246 |
NBI report | TWP 23 | JUD DITCH # 11 | 0.5 MI W OF JCT CSAH 29 | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 22.0 | 24.9 | Fair | 37.9 | L5173 |
NBI report | US 71 | PHART CREEK | 0.6 MI S OF JACKSON | Concrete Culvert (3 spans) | -- | 1924 | -- | 11.2 | 34.1 | Fair | 78.6 | 3491 |
NBI report | CSAH 18 | JUD DITCH # 84 | 0.3 MI W OF JCT CR 63 | Concrete Girder and floorbeam system | -- | 1925 | -- | 29.9 | 32.5 | Fair | 66.1 | 3988 |
NBI report Bridgehunter | CR 66 | LITTLE SIOUX RIVER | 2.9 MI W OF JCT TH 86 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1937 | -- | 25.6 | 77.4 | Fair | 65.8 | 5738 |
NBI report Bridgehunter | CSAH 9 | JACK CREEK | 1.9 MI S OF JCT TH 60 | Wood Stringer/Multi-beam or girder (3 spans) | -- | 1940 | -- | 30.8 | 94.5 | Fair | 60.2 | 5937 |
NBI report | CSAH 9 | STREAM | 1.1 MI S OF JCT TH 60 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1940 | -- | 29.9 | 64.0 | Fair | 59.9 | 5938 |
NBI report | CR 61 | JACK CREEK | 0.1 MI S OF JCT CR 63 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1941 | -- | 29.9 | 63.0 | Fair | 62.5 | 6421 |
NBI report | CR 63 | JACK CREEK | 0.9 MI W OF JCT TH 60 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1941 | -- | 30.8 | 63.7 | Fair | 63.8 | 89256 |
NBI report | CSAH 22 | S FK ELM CREEK | 2.3 MI E OF JCT TH 71 | Wood Slab (3 spans) | -- | 1954 | -- | 18.0 | 54.5 | Fair | 61.2 | 89250 |
NBI report | CSAH 18 | OKABENA CREEK | 1.1 MI W OF JCT CR 63 | Wood Slab (3 spans) | -- | 1955 | -- | 24.9 | 78.1 | Poor | 60.6 | 89247 |
NBI report Bridgehunter | CSAH 14 | DES MOINES RIVER | IN JACKSON | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1955 | 1982 | 90.6 | 207.7 | Good | 92.5 | 7105 |
NBI report | CSAH 17 | STREAM | 0.2 MI N OF JCT CR 82 | Wood Slab (2 spans) | -- | 1958 | -- | 17.1 | 36.1 | Fair | 96.0 | 89244 |
NBI report Bridgehunter | TWP 171 | HERON LAKE OUTLET | 0.8 MI S OF JCT TH 60 | Wood Slab (4 spans) | -- | 1959 | -- | 22.0 | 88.9 | Poor | 35.0 | L5227 |
NBI report | CSAH 14 | CO DITCH # 3 | 0.5 MI E OF JCT CR 63 | Wood Slab | -- | 1960 | -- | 24.0 | 25.9 | Poor | 53.7 | 89242 |
NBI report | TWP 25 | JUD DITCH # 6 | 1.7 MI W OF JCT TH 71 | Wood Slab | -- | 1960 | -- | 23.6 | 25.6 | Poor | 42.8 | L5174 |
NBI report | CSAH 29 | N FK ELM CREEK | 0.8 MI W OF JCT CR 85 | Wood Slab | -- | 1962 | -- | 22.0 | 24.0 | Poor | 45.7 | 89252 |
NBI report Bridgehunter | CR 67 | LITTLE SIOUX RIVER | 1.1 MI N OF JCT CSAH 4 | Wood Slab (3 spans) | -- | 1963 | -- | 24.0 | 71.9 | Fair | 70.1 | 32502 |
NBI report | CR 68 | CO DITCH # 117 | 1.1 MI W OF JCT TH 86 | Wood Slab (2 spans) | -- | 1964 | -- | 20.0 | 40.0 | Fair | 85.0 | 32503 |
NBI report Bridgehunter | CSAH 4 | DES MOINES RIVER | 0.2 MI S OF JCT CSAH 23 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 75.1 | 201.1 | Fair | 92.6 | 32501 |
NBI report | TWP 197 | SKUNK CREEK | 0.8 MI S OF JCT CSAH 4 | Wood Slab (3 spans) | -- | 1966 | -- | 18.0 | 49.9 | Fair | 68.2 | L8960 |
NBI report | CSAH 14 | OKABENA CREEK | 0.2 MI E OF CO LINE | Wood Slab (3 spans) | -- | 1967 | -- | 25.9 | 78.1 | Good | 76.3 | 32506 |
NBI report | CSAH 24 | STREAM | 0.5 MI W OF JCT CSAH 24 | Steel Stringer/Multi-beam or girder | -- | 1967 | -- | 34.1 | 36.4 | Poor | 36.7 | 89264 |
NBI report | CSAH 7 | JACK CREEK | 1.0 MI N OF TH 60 | Wood Slab (3 spans) | -- | 1967 | -- | 25.9 | 78.1 | Fair | 96.2 | 32505 |
NBI report | TWP 106 | OKABENA CREEK | 0.2 MI N OF JCT CSAH 20 | Wood Slab (3 spans) | -- | 1967 | -- | 25.9 | 78.1 | Fair | 65.5 | 32507 |
NBI report | CR 84 | N FK ELM CREEK | 1.2 MI W OF JCT CSAH 29 | Wood Slab | -- | 1968 | -- | 24.0 | 26.6 | Fair | 97.0 | 92400 |
NBI report | TWP 130 | N FK ELM CREEK | 0.2 MI S OF JCT CR 84 | Wood Slab | -- | 1968 | -- | 24.0 | 25.9 | Fair | 97.0 | L8958 |
NBI report | CR 61 | N BR JACK CREEK | 0.4 MI S OF JCT CSAH 24 | Wood Slab (3 spans) | -- | 1969 | -- | 18.0 | 54.1 | Fair | 74.4 | 32508 |
NBI report | CR 61 | JUD DITCH # 76 | 0.5 MI N OF JCT TH 60 | Wood Slab (3 spans) | -- | 1969 | -- | 18.0 | 54.1 | Good | 100.0 | 32509 |
NBI report | TWP 1 | JUD DITCH # 24 | 0.8 MI S OF ROUND LAKE | Wood Slab | -- | 1969 | -- | 24.0 | 25.9 | Fair | 89.0 | 32511 |
NBI report | CR 63 | JUD DITCH # 76 | 0.8 MI N OF JCT CSAH 20 | Wood Slab (3 spans) | -- | 1970 | -- | 18.0 | 54.1 | Fair | 100.0 | 32515 |
NBI report | CSAH 14 | JUD DITCH # 3 | 1.6 MI W OF JCT TH 86 | Wood Slab (3 spans) | -- | 1970 | -- | 25.9 | 62.3 | Good | 99.9 | 32510 |
NBI report | CSAH 17 | JUD DITCH # 8 | 0.1 MI S OF JCT CR 68 | Wood Slab (3 spans) | -- | 1970 | -- | 18.0 | 54.1 | Fair | 97.0 | 32512 |
NBI report Bridgehunter | TWP 29 | N FK LITTLE SIOUX RIVER | 1.0 MI W OF JCT TH 86 | Wood Slab | -- | 1970 | -- | 32.2 | 34.5 | Fair | 78.3 | L9311 |
NBI report | CR 67 | I 90 | 2.0 MI W OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 301.9 | Good | 90.9 | 32818 |
NBI report | CR 85 | I 90 | 4.2 MI E OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 306.4 | Fair | 89.1 | 32814 |
NBI report | CSAH 14 | I 90 | 2.0 MI W OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 86.0 | 313.7 | Good | 95.5 | 32806 |
NBI report | CSAH 17 | I 90 | 4.0 MI E OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 314.3 | Good | 91.5 | 32805 |
NBI report | CSAH 23 | I 90 | 1.0 MI E OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 306.4 | Fair | 89.9 | 32810 |
NBI report | CSAH 29 | I 90 | 6.2 MI E OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 309.1 | Good | 91.5 | 32815 |
NBI report | CSAH 5 | I 90 | 10.0 MI W OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 294.6 | Fair | 86.1 | 32801 |
NBI report | CSAH 9 | I 90 | 7.0 MI W OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 86.3 | 302.2 | Fair | 98.5 | 32802 |
NBI report | I 90 EB | DES MOINES R; RD | 1.1 MI W OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 98.1 | 299.2 | Fair | 88.9 | 32808 |
NBI report | I 90 EB | TH 71 | AT JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 79.7 | 307.1 | Fair | 94.9 | 32812 |
NBI report | I 90 WB | DES MOINES R; RD | 1.1 MI W OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 98.1 | 299.2 | Fair | 88.9 | 32807 |
NBI report | I 90 WB | TH 71 | AT JCT TH 71 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 79.7 | 307.1 | Fair | 97.9 | 32811 |
NBI report | MN 86 | I 90 | AT JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 86.0 | 307.8 | Fair | 95.0 | 32804 |
NBI report | TR 170 | I 90 | 5.0 MI W OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 85.6 | 278.2 | Good | 91.5 | 32816 |
NBI report | I 90 | MIDDLESTADT CREEK | 6.7 MI W OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 1973 | -- | 9.8 | 21.0 | Fair | 74.5 | 91223 |
NBI report Bridgehunter | SOO LINE (ABAN) | I 90 | 0.7 MI W OF JCT TH 71 | Steel Girder and floorbeam system | -- | 1973 | -- | 82.7 | -- | -- | -- | 32809 |
NBI report | TWP 176 | SKUNK CREEK | 1.1 MI N OF JCT CSAH 4 | Wood Slab | -- | 1973 | -- | 26.9 | 27.9 | Fair | 81.0 | 32517 |
NBI report | TWP 178 | JUD DITCH # 84 | 0.4 MI S OF JCT CSAH 20 | Steel Stringer/Multi-beam or girder | -- | 1973 | -- | 39.0 | 41.0 | Fair | 77.3 | 32518 |
NBI report | CSAH 1 | OKABENA CREEK | 0.4 MI N OF JCT CSAH 12 | Concrete Culvert (2 spans) | -- | 1974 | -- | 14.1 | 32.2 | Good | 99.9 | 93132 |
NBI report | CSAH 34 | I 90 | 1.9 MI E OF JCT TH 71 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 119.8 | 428.5 | Good | 96.7 | 32813 |
NBI report | TWP 70 | CO DITCH # 3 | 1.2 MI W OF JCT CSAH 9 | Steel Stringer/Multi-beam or girder | -- | 1974 | -- | 36.1 | 37.1 | Fair | 55.6 | L9448 |
NBI report | CR 68 | LITTLE SIOUX RIVER | 0.9 MI E OF JCT CSAH 9 | Wood Slab (3 spans) | -- | 1975 | -- | 25.9 | 78.1 | Good | 97.0 | 93104 |
NBI report | TWP 106 | JACK CREEK | 0.7 MI S OF JCT TH 60 | Wood Slab (3 spans) | -- | 1975 | -- | 25.9 | 78.1 | Fair | 97.0 | L9541 |
NBI report | CR 63 | OKABENA CREEK | 0.4 MI N OF JCT CSAH 20 | Wood Slab (3 spans) | -- | 1976 | -- | 25.9 | 78.1 | Good | 99.8 | 32514 |
NBI report | CR 85 | ELM CREEK | 0.9 MI S OF JCT CSAH 29 | Wood Stringer/Multi-beam or girder | -- | 1976 | -- | 49.9 | 52.2 | Good | 79.9 | 32520 |
NBI report | CR 85 | S FK ELM CREEK | 1.2 MI N OF JCT CSAH 22 | Wood Slab (3 spans) | -- | 1976 | -- | 25.9 | 62.0 | Good | 100.0 | 32521 |
NBI report Bridgehunter | CSAH 16 | DES MOINES RIVER | 2.5 MI W OF JCT TH 71 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1976 | -- | 89.9 | 182.8 | Good | 94.8 | 32519 |
NBI report | TWP 127 | S FK ELM CREEK | 1.2 MI S OF JCT CSAH 28 | Wood Slab (2 spans) | -- | 1976 | -- | 24.0 | 47.9 | Good | 97.0 | L9631 |
NBI report | TWP 21 | JUD DITCH # 6 | 0.9 MI W OF JCT TH 71 | Wood Stringer/Multi-beam or girder | -- | 1976 | -- | 33.1 | 34.1 | Fair | 89.4 | L9630 |
NBI report | CSAH 3 | W FK LITTLE SIOUX RIVER | 0.8 MI N OF JCT CSAH 4 | Steel Culvert (2 spans) | -- | 1977 | -- | 9.2 | 21.7 | Fair | 94.8 | 93293 |
NBI report | CR 63 | JUD DITCH # 84 | 0.9 MI S OF JCT CSAH 20 | Wood Slab (3 spans) | -- | 1978 | -- | 32.2 | 84.0 | Fair | 99.1 | 32530 |
NBI report Bridgehunter | CR 86 | HERON LAKE OUTLET | 0.7 MI W OF JCT CR 82 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 38.4 | 115.2 | Good | 100.0 | 32522 |
NBI report | CSAH 29 | E FK DES MOINES RIVER | 0.5 MI S OF JCT CSAH 16 | Concrete Culvert (2 spans) | -- | 1978 | -- | 9.5 | 20.7 | Good | 99.9 | 91794 |
NBI report | TWP 106 | CO DITCH # 3 | 0.3 MI N OF JCT CSAH 18 | Prestressed Stringer/Multi-beam or girder | -- | 1978 | -- | 43.6 | 46.3 | Fair | 100.0 | 32523 |
NBI report | TWP 127 | N FK ELM CREEK | 0.1 MI N OF JCT CSAH 29 | Concrete Culvert (2 spans) | -- | 1978 | -- | 10.2 | 25.6 | Good | 100.0 | 91695 |
NBI report | TWP 14 | W FK LITTLE SIOUX RIVER | 2.0 MI E OF JCT CSAH 5 | Wood Slab (3 spans) | -- | 1978 | -- | 25.9 | 62.0 | Good | 100.0 | 32525 |
NBI report | TWP 57 | E FK DES MOINES RIVER | 0.2 MI E OF JCT CSAH 29 | Concrete Culvert (2 spans) | -- | 1978 | -- | 11.2 | 27.2 | Good | 100.0 | 91769 |
NBI report | TWP 60 | OKABENA CREEK | 0.7 MI E OF W CO LINE | Wood Slab (3 spans) | -- | 1978 | -- | 25.9 | 78.1 | Good | 100.0 | 32524 |
NBI report | CSAH 20 | JUD DITCH # 3 | 2.8 MI NW OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 1979 | -- | 14.1 | 32.8 | Good | 99.8 | 91768 |
NBI report | CSAH 23 | STREAM | 0.2 MI SE OF JCT CSAH 4 | Prestressed Stringer/Multi-beam or girder | -- | 1979 | -- | 56.1 | 58.7 | Good | 99.7 | 32531 |
NBI report | TWP 106 | CO DITCH # 3 | 0.5 MI S OF JCT CSAH 18 | Concrete Culvert (2 spans) | -- | 1979 | -- | 12.8 | 32.5 | Good | 100.0 | 91843 |
NBI report Bridgehunter | TWP 131 | DES MOINES RIVER | 0.1 MI S OF JCT CSAH 23 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 69.9 | 184.7 | Good | 100.0 | 32527 |
NBI report | TWP 170 | LITTLE SIOUX RIVER | 0.2 MI N OF JCT CSAH 34 | Concrete Culvert (3 spans) | -- | 1979 | -- | 11.5 | 45.6 | Good | 100.0 | 95011 |
NBI report | TWP 193 | JACK CREEK | 0.1 MI S OF JCT CSAH 24 | Concrete Culvert (3 spans) | -- | 1979 | -- | 11.8 | 47.2 | Good | 100.0 | 95086 |
NBI report | TWP 209 | JUD DITCH # 13 | 0.1 MI S OF JCT CR 68 | Concrete Culvert (3 spans) | -- | 1979 | -- | 13.5 | 53.2 | Good | 100.0 | 95022 |
NBI report | TWP 37 | JUD DITCH # 3 | 1.2 MI W OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 1979 | -- | 12.8 | 32.5 | Good | 98.0 | 91844 |
NBI report | TWP 37 | JUD DITCH # 3 | 1.0 MI W OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 1979 | -- | 14.8 | 37.4 | Good | 100.0 | 91845 |
NBI report | TWP 90 | JUD DITCH # 76 | 1.5 MI N OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 1979 | -- | 14.1 | 34.5 | Good | 100.0 | 95085 |
NBI report | US 71 | STONY BROOK (JD# 6) | 5.3 MI S OF JCT CSAH 34 | Prestressed Stringer/Multi-beam or girder | -- | 1979 | -- | 84.3 | 86.9 | Good | 98.1 | 32001 |
NBI report | TWP 106 | STREAM | 0.5 MI S OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 1980 | -- | 12.8 | 32.2 | Good | 100.0 | 91890 |
NBI report | TWP 132 | S FK ELM CREEK | 0.7 MI S OF JCT CSAH 22 | Concrete Culvert (2 spans) | -- | 1980 | -- | 11.5 | 29.5 | Good | 100.0 | 91894 |
NBI report | TWP 194 | STREAM | 1.3 MI S OF JCT CSAH 34 | Wood Slab (3 spans) | -- | 1980 | -- | 24.0 | 71.9 | Good | 87.3 | 32533 |
NBI report | TWP 197 | SKUNK CREEK (JD # 13) | 1.7 MI S OF JCT CSAH 4 | Wood Slab (3 spans) | -- | 1980 | -- | 23.6 | 71.2 | Good | 100.0 | 32532 |
NBI report | TWP 305 | STREAM | 0.7 MI E OF JCT CSAH 25 | Steel Culvert (2 spans) | -- | 1980 | -- | 9.5 | 21.7 | Fair | 94.8 | R0006 |
NBI report | TWP 38 | JUD DITCH # 8 | 0.6 MI E OF JCT CSAH 17 | Concrete Culvert (2 spans) | -- | 1980 | -- | 12.8 | 30.5 | Good | 98.0 | 95058 |
NBI report | TWP 60 | JUD DITCH # 3 | 1.6 MI E OF JCT CSAH 9 | Concrete Culvert (2 spans) | -- | 1980 | -- | 11.2 | 33.5 | Good | 100.0 | 91912 |
NBI report | TWP 108 | N FK ELM CREEK | 0.2 MI E OF JCT CSAH 29 | Concrete Culvert (2 spans) | -- | 1981 | -- | 10.2 | 24.9 | Good | 100.0 | 95404 |
NBI report | TWP 117 | STREAM | 0.9 MI N OF JCT CR 82 | Concrete Culvert (3 spans) | -- | 1981 | -- | 10.2 | 39.4 | Good | 100.0 | 95338 |
NBI report | TWP 129 | JUD DITCH # 60 | 1.1 MI S OF JCT CSAH 34 | Concrete Culvert (2 spans) | -- | 1981 | -- | 11.5 | 29.5 | Good | 100.0 | 95501 |
NBI report | TWP 132 | ELM CREEK (CD #13) | 0.7 MI N OF JCT CSAH 28 | Concrete Culvert (2 spans) | -- | 1981 | -- | 11.5 | 27.6 | Good | 100.0 | 95394 |
NBI report | TWP 170 | JUD DITCH # 3 | 0.5 MI N OF JCT CSAH 14 | Concrete Culvert (2 spans) | -- | 1981 | -- | 10.2 | 24.9 | Good | 100.0 | 91913 |
NBI report | TWP 188 | JUD DITCH # 24 | 1.1 MI S OF JCT CSAH 4 | Concrete Culvert (3 spans) | -- | 1981 | -- | 12.8 | 49.9 | Good | 100.0 | 95594 |
NBI report | TWP 205 | JUD DITCH # 25 | 0.9 MI S OF JCT CR 68 | Concrete Culvert (3 spans) | -- | 1981 | -- | 10.2 | 39.4 | Good | 100.0 | 95358 |
NBI report | TWP 206 | JUD DITCH # 28 | 0.2 MI N OF JCT CSAH 34 | Concrete Culvert (3 spans) | -- | 1981 | -- | 11.2 | 44.9 | Good | 100.0 | 95435 |
NBI report | TWP 29 | JUD DITCH # 25 | 0.9 MI W OF JCT CSAH 9 | Concrete Culvert (2 spans) | -- | 1981 | -- | 10.2 | 24.9 | Good | 100.0 | 95378 |
NBI report | TWP 34 | STREAM | 1.7 MI S OF JCT CSAH 14 | Concrete Culvert (2 spans) | -- | 1981 | -- | 11.5 | 29.5 | Good | 100.0 | 95499 |
NBI report | TWP 41 | LITTLE SIOUX RIVER | 1.5 MI E OF JCT CSAH 9 | Concrete Culvert (3 spans) | -- | 1981 | -- | 9.8 | 40.0 | Good | 100.0 | 95560 |
NBI report | TWP 45 | JUD DITCH # 60 | 2.1 MI W OF JCT CSAH 29 | Concrete Culvert (2 spans) | -- | 1981 | -- | 13.1 | 34.1 | Good | 100.0 | 95496 |
NBI report | TWP 77 | JUD DITCH # 76 | 0.5 MI E OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 1981 | -- | 11.5 | 29.5 | Good | 100.0 | 95432 |
NBI report | CSAH 29 | N FK ELM CREEK | 1.1 MI N OF JCT CSAH 30 | Concrete Culvert (2 spans) | -- | 1983 | -- | 9.8 | 26.9 | Good | 99.9 | 95740 |
NBI report | TWP 160 | JUD DITCH # 3 | 0.8 MI S OF JCT CSAH 20 | Concrete Culvert (2 spans) | -- | 1983 | -- | 14.1 | 34.5 | Good | 98.3 | 91855 |
NBI report | TWP 208 | SKUNK CREEK (JD # 13) | 1.0 MI S OF JCT CR 68 | Concrete Culvert (2 spans) | -- | 1983 | -- | 14.1 | 34.5 | Good | 100.0 | 95405 |
NBI report | CSAH 4 | SKUNK CREEK | 0.1 MI W OF JCT CSAH 9 | Prestressed Stringer/Multi-beam or girder | -- | 1984 | -- | 72.8 | 75.5 | Good | 91.7 | 32537 |
NBI report Bridgehunter | MUN 15 | DES MOINES RIVER | 0.1 MI E OF 3RD ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 85.0 | 227.4 | Good | 95.0 | 32540 |
NBI report | CSAH 5 | SKUNK CREEK (JD # 13) | 0.7 MI S OF JCT CR 68 | Wood Slab (3 spans) | -- | 1986 | -- | 31.5 | 67.3 | Good | 100.0 | 32535 |
NBI report | TWP 132 | ELM CREEK | 0.3 MI N OF JCT CSAH 28 | Concrete Culvert (2 spans) | -- | 1986 | -- | 10.2 | 26.2 | Good | 100.0 | 95300 |
NBI report | TWP 184 | JACK CREEK | 0.6 MI N OF JCT CR 63 | Wood Slab (3 spans) | -- | 1986 | -- | 32.2 | 96.1 | Good | 99.1 | 32534 |
NBI report | TWP 66 | JUD DITCH # 31 | 0.9 MI N OF JCT CSAH 20 | Concrete Culvert (3 spans) | -- | 1986 | -- | 8.5 | 33.5 | Good | 100.0 | 95595 |
NBI report Bridgehunter | TH 60 EB | HERON LAKE OUTLET | 4.2 MI SW OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1987 | -- | 59.4 | 123.0 | Good | 98.3 | 32002 |
NBI report | TH 60 EB | JACK CREEK | 14.3 MI NE OF JCT TH 90 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1987 | -- | 59.1 | 122.4 | Good | 97.2 | 32003 |
NBI report | TH 60 EB | JUD DITCH # 76 | 10.0 MI NE OF JCT TH 90 | Prestressed Stringer/Multi-beam or girder | -- | 1987 | -- | 76.1 | 81.7 | Good | 96.7 | 32004 |
NBI report | TWP 14 | W FK LITTLE SIOUX RIVER | 1.4 MI E OF JCT CSAH 5 | Concrete Culvert (3 spans) | -- | 1990 | -- | 12.8 | 49.9 | Good | 100.0 | 95587 |
NBI report | CR 69 | LITTLE SIOUX RIVER | 1.5 MI W OF JCT TH 86 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 41.3 | 124.0 | Good | 100.0 | 32548 |
NBI report | TWP 130 | ELM CREEK | 1.1 MI S OF JCT CSAH 30 | Concrete Culvert (2 spans) | -- | 1991 | -- | 14.8 | 37.4 | Good | 100.0 | 95172 |
NBI report | TWP 183 | JUD DITCH # 76 | 0.5 MI N OF JCT CSAH 20 | Concrete Culvert (3 spans) | -- | 1991 | -- | 18.0 | 70.5 | Good | 100.0 | 95336 |
NBI report | TWP 73 | S FK ELM CREEK | 0.5 MI W OF JCT CR 85 | Concrete Culvert (3 spans) | -- | 1991 | -- | 10.2 | 41.0 | Good | 100.0 | 95547 |
NBI report | TWP 97 | ELM CREEK | 0.1 MI W OF JCT CSAH 29 | Wood Slab (3 spans) | -- | 1991 | -- | 27.6 | 70.9 | Good | 100.0 | 32542 |
NBI report | TWP 97 | ELM CREEK | 0.8 MI W OF JCT CR 85 | Concrete Culvert (2 spans) | -- | 1991 | -- | 14.8 | 40.7 | Good | 100.0 | 95337 |
NBI report | CSAH 9 | SKUNK CREEK | 0.2 MI S OF JCT CSAH 4 | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 64.0 | 65.3 | Good | 100.0 | 32546 |
NBI report | TWP 186 | JACK CREEK | 0.4 MI S OF JCT CR 63 | Concrete Culvert (3 spans) | -- | 1993 | -- | 14.4 | 55.1 | Good | 100.0 | 95289 |
NBI report | TWP 31 | STONY BROOK | 1.7 MI N OF JCT CSAH 4 | Wood Slab (3 spans) | -- | 1993 | -- | 27.9 | 84.0 | Good | 100.0 | 32538 |
NBI report | TWP 24 | STONY BROOK | 1.6 MI SW OF JCT CSAH 23 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 33.5 | 100.1 | Good | 100.0 | 32547 |
NBI report | CSAH 30 | DES MOINES RIVER | 0.2 MI E OF JCT CSAH 17 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 52.2 | 156.5 | Good | 99.9 | 32551 |
NBI report | TWP 186 | STREAM | 1.7 MI S OF JCT CSAH 24 | Concrete Culvert (2 spans) | -- | 1997 | -- | 9.8 | 24.6 | Good | 100.0 | 95848 |
NBI report | TWP 211 | JUD DITCH # 13 | 0.3 MI N OF JCT CR 68 | Concrete Culvert (2 spans) | -- | 1997 | -- | 11.8 | 29.5 | Good | 98.0 | 32J01 |
NBI report | TWP 29 | JUD DITCH # 13 | 1.6 MI E OF JCT CSAH 5 | Concrete Culvert (2 spans) | -- | 1997 | -- | 13.1 | 31.8 | Good | 100.0 | 32J03 |
NBI report | TWP 70 | OKABENA CREEK | 0.2 MI W OF JCT CR 63 | Concrete Slab (3 spans) | -- | 1997 | -- | 27.9 | 74.5 | Good | 100.0 | 32539 |
NBI report | TWP 76 | JUD DITCH # 76 | 0.3 MI W OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 1997 | -- | 14.4 | 34.5 | Good | 100.0 | 32J02 |
NBI report | CSAH 29 | ELM CREEK | 0.1 MI S OF JCT CSAH 28 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 34.8 | 80.1 | Good | 100.0 | 32553 |
NBI report | CSAH 9 | OKABENA CREEK | 0.4 MI N OF JCT CSAH 20 | Concrete Slab (3 spans) | -- | 1998 | -- | 49.9 | 133.2 | Fair | 99.8 | 32550 |
NBI report | TH 60 | STREAM | 1.4 MI SW OF HERON LAKE | Concrete Culvert (2 spans) | -- | 1999 | -- | 7.9 | 22.3 | Good | 83.0 | 97058 |
NBI report | TH 60 WB | JUD DITCH # 76 | WB OVER JUD DITCH # 76 | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 79.1 | 85.3 | Good | 95.8 | 32005 |
NBI report | TH 60 WB | JACK CREEK | 14.3 MI NE OF JCT TH 90 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1999 | -- | 63.0 | 129.3 | Good | 99.2 | 32006 |
NBI report | TWP 205 | LITTLE SIOUX RIVER | 0.3 MI S OF JCT CSAH 34 | Concrete Culvert (2 spans) | -- | 1999 | -- | 13.1 | 32.8 | Good | 100.0 | 32J07 |
NBI report | TWP 76 | JUD DITCH # 76 | 0.9 MI W OF JCT TH 60 | Concrete Culvert (3 spans) | -- | 1999 | -- | 13.5 | 53.2 | Good | 100.0 | 32J08 |
NBI report | CSAH 29 | JUD DITCH # 32 | 1.2 MI N OF JCT CSAH 34 | Concrete Culvert (2 spans) | -- | 2000 | -- | 14.1 | 32.5 | Good | 100.0 | 32J16 |
NBI report | CSAH 4 | LOON LAKE OUTLET | 0.7 MI E OF JCT CSAH 2 | Concrete Culvert (2 spans) | -- | 2000 | -- | 14.1 | 30.8 | Good | 99.9 | 32J06 |
NBI report | TWP 132 | SO FRK ELM CREEK | 0.2 MI S OFJCT CSAH 22 | Concrete Culvert (2 spans) | -- | 2000 | -- | 12.8 | 32.5 | Good | 100.0 | 32J18 |
NBI report | TWP 6 | STREAM | 1.5 MI S OFJCT CSAH 4 | Concrete Culvert (2 spans) | -- | 2000 | -- | 12.1 | 27.2 | Good | 100.0 | 32J11 |
NBI report | CSAH 29 | STREAM | 1.1 MI S OF JCT CSAH 34 | Concrete Culvert (2 spans) | -- | 2001 | -- | 11.5 | 29.9 | Good | 100.0 | 32J13 |
NBI report | MNTH 60 | Duck Lake Outlet | 1.1 mi NE of Heron Lake | Concrete Culvert (2 spans) | -- | 2001 | -- | 12.1 | 29.5 | Good | 85.0 | 97443 |
NBI report | TH 60 WB | HERON LAKE OUTLET | 4.2 mi SW of JCT TH 86 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 68.9 | 143.1 | Good | 98.3 | 32009 |
NBI report | TOWNSHIP RD 178 | CO DITCH # 3 | 0.5 MI N OF JCT CSAH 14 | Concrete Culvert (2 spans) | -- | 2002 | -- | 12.1 | 25.3 | Good | 100.0 | 32J14 |
NBI report | TOWNSHIP RD 205 | LITTLE SIOUX RIVER | 1.3 MI N OF JCT CSAH 34 | Concrete Culvert (3 spans) | -- | 2002 | -- | 11.5 | 45.6 | Good | 100.0 | 95540 |
NBI report | TOWNSHIP RD 60 | CO DITCH # 3 | 1.2 MI W OF JCT CSAH 9 | Concrete Culvert (2 spans) | -- | 2002 | -- | 14.8 | 32.2 | Good | 100.0 | 95876 |
NBI report | TWP 351 | Jud Ditch # 13 | 0.6 mi E of jct TH 264 | Concrete Culvert (2 spans) | -- | 2002 | -- | 13.8 | 26.9 | Good | 100.0 | 32J20 |
NBI report | CSAH 34 | JUD DITCH # 28 | 0.8 MI W OF JCT CSAH 9 | Concrete Culvert (2 spans) | -- | 2003 | -- | 13.1 | 33.8 | Good | 99.9 | 32J25 |
NBI report | TNSP RD 2 | SKUNK CREEK | 1.2 MI E OF JCT CSAH 9 | Wood Slab (3 spans) | -- | 2003 | -- | 24.0 | 67.9 | Good | 100.0 | 32545 |
NBI report | TNSP 174 | JUD DITCH # 28 | 0.1 MI S OF JCT CSAH 34 | Concrete Culvert (2 spans) | -- | 2003 | -- | 12.8 | 32.2 | Good | 100.0 | 32J26 |
NBI report | TNSP 181 | STREAM | 1.7 MI N OF JCT CSAH 32 | Concrete Culvert (2 spans) | -- | 2003 | -- | 12.1 | 28.9 | Good | 100.0 | 95059 |
NBI report | TNSP RD 130 | S FK ELM CREEK | 0.3 MI N OF JCT CSAH 22 | Concrete Culvert (3 spans) | -- | 2003 | -- | 12.1 | 37.1 | Good | 100.0 | 95402 |
NBI report | TWP 76 | JUD DITCH # 76 | 1.1 MI W OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 2003 | -- | 12.8 | 32.2 | Good | 100.0 | 32J27 |
NBI report | 510TH AVE | DES MOINES RIVER | 1.5 MI N OF JCT CSAH 16 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 57.7 | 172.9 | Good | 100.0 | 32554 |
NBI report | CSAH 34 | LITTLE SIOUX RIVER | 14.7 MI W OF JACKSON | Concrete Culvert (3 spans) | -- | 2004 | -- | 14.1 | 41.7 | Good | 99.9 | 32J30 |
NBI report | 340th AVE (TWP 183 | JACK CREEK OVERFLOW | 0.5 MI N OF JCT TH 60 | Concrete Culvert (2 spans) | -- | 2005 | -- | 12.1 | 25.3 | Good | 100.0 | 32J34 |
NBI report | CSAH 3 | JUD DITCH # 13 | 0.1 MI S OF JCT CR 68 | Concrete Culvert (2 spans) | -- | 2005 | -- | 12.1 | 24.9 | Good | 100.0 | 32J29 |
NBI report | CSAH 9 | W FK LITTLE SIOUX RIVER | 1.4 MI S OF JCT CSAH 4 | Concrete Culvert (3 spans) | -- | 2005 | -- | 12.5 | 41.0 | Good | 100.0 | 32J21 |
NBI report | CR 66 | N BR LITTLE SIOUX RIVER | 1.3 MI W OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 2006 | -- | 12.1 | 25.9 | Good | 100.0 | 32J39 |
NBI report | CSAH 14 | JUD DITCH # 3 | 2.4 MI W OF JCT TH 86 | Concrete Culvert (2 spans) | -- | 2006 | -- | 12.5 | 26.6 | Good | 99.9 | 32J36 |
NBI report | CSAH 29 | S FK ELM CREEK | 0.1 MI N OF JCT CSAH 26 | Prestressed Stringer/Multi-beam or girder | -- | 2006 | -- | 66.6 | 68.2 | Good | 100.0 | 32563 |
NBI report | 375 AVE (TWP 176) | W FK LITTLE SIOUX RIVER | 1.2 MI S OF JCT CSAH 4 | Concrete Culvert (3 spans) | -- | 2007 | -- | 9.8 | 35.1 | Good | 100.0 | 32J44 |
NBI report | 320 AVE | OKABENA CREEK | 0.5 MI S OF JCT CSAH 18 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2008 | -- | 30.2 | 90.9 | Good | 100.0 | 32566 |
NBI report | 810 ST | OKABENA CREEK | 0.3 MI E OF JCT CSAH 1 | Concrete Culvert (3 spans) | -- | 2009 | -- | 14.1 | 37.7 | Good | 100.0 | 32J45 |
NBI report | CSAH 28 | ELM CREEK | 0.1 MI E OF JCT CSAH 29 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 22.3 | 66.9 | Good | 98.0 | 32567 |
NBI report | CSAH 20 | CO DITCH # 3 | 1.4 MI E OF JCT CR 63 | Concrete Slab (3 spans) | -- | 2010 | -- | 27.9 | 74.5 | Good | 98.0 | 32564 |
NBI report | 330 AVE | JACK CREEK | 0.9 MI S OF JCT CSAH 24 | Concrete Culvert (2 spans) | -- | 2011 | -- | 14.1 | 29.9 | Good | 98.0 | 32J46 |
NBI report | CR 62 | W FK LITTLE SIOUX RIVER | 1.3 MI E OF JCT CSAH 9 | Prestressed Stringer/Multi-beam or girder | -- | 2011 | -- | 78.7 | 81.0 | Good | 98.0 | 32570 |
NBI report | CR 66 | JUD DITCH # 35 | 1.6 MI W OF JCT CSAH 17 | Concrete Culvert (2 spans) | -- | 2011 | -- | 12.5 | 26.6 | Good | 98.0 | 32J49 |
NBI report | CR 66 | JUD DITCH # 8 | 0.6 MI W OF JCT CSAH 17 | Concrete Culvert (2 spans) | -- | 2011 | -- | 12.1 | 25.9 | Good | 98.0 | 32J50 |
NBI report | 340 AVE | STREAM | 0.1 MI N OF JCT CR 63 | Concrete Culvert (2 spans) | -- | 2012 | -- | 9.8 | 21.7 | Good | 98.0 | 32J51 |
NBI report | 770TH ST | LITTLE SIOUX RIVER | 0.9 MI E OF JCT CSAH 9 | Concrete Culvert (3 spans) | -- | 2012 | -- | 12.5 | 26.6 | Good | 98.0 | 32J57 |
NBI report | CR 68 | JUD DITCH # 13 | 0.1 MI W OF JCT CSAH 3 | Concrete Culvert (2 spans) | -- | 2012 | -- | 17.1 | 36.4 | Good | 98.0 | 32J54 |
NBI report | CSAH 20 | OKABENA CREEK | 1.6 MI E OF JCT TH 60 | Concrete Slab (3 spans) | -- | 2012 | -- | 29.9 | 80.4 | Good | 98.0 | 32571 |
NBI report | CSAH 28 | ELM CREEK | 0.7 MI E OF JCT CSAH 29 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2012 | -- | 26.2 | 80.1 | Good | 98.0 | 32569 |
NBI report | CSAH 4 | JUD DITCH # 11 | 0.7 MI W OF JCT CSAH 29 | Concrete Culvert (2 spans) | -- | 2012 | -- | 12.5 | 26.6 | Good | 98.0 | 32J55 |
NBI report | 715TH ST (CSAH 4) | LITTLE SIOUX RIVER | 1.6 MI W OF JCT TH 86 | Concrete Slab (3 spans) | -- | 2013 | -- | 36.1 | 97.1 | Good | 98.0 | 32573 |
NBI report | 870TH STREET | S FK ELM CREEK | 0.1 MI W OF JCT CSAH 29 | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 75.1 | 78.4 | Good | 99.0 | 32572 |
NBI report | 750TH ST | LITTLE SIOUX RIVER | 0.9 MI E OF JCT CSAH 9 | Concrete Slab (3 spans) | -- | 2014 | -- | 22.0 | 61.0 | Good | 98.0 | 32574 |
NBI report | 365TH AVE | W FK LITTLE SIOUX RIVER | 0.9 MI S OF JCT CSAH 4 | Concrete Culvert (2 spans) | -- | 2015 | -- | 9.8 | 21.7 | Good | 98.0 | 32J28 |
NBI report | 590TH AVE | STREAM | 1.1 MI NW OF JCT CSAH 29 | Wood Slab (3 spans) | -- | 2015 | -- | 18.0 | 54.1 | Good | 97.0 | 32577 |
NBI report | US 71 | DES MOINES RIVER | 0.4 MI N OF JACKSON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2015 | -- | 59.1 | 177.5 | Good | 99.4 | 32011 |
NBI report | 590TH AVE | ELM CREEK | 0.9 MI S OF JCT CSAH 29 | Concrete Slab | -- | 2016 | -- | 37.1 | 40.0 | Good | 97.0 | 32578 |
NBI report | CSAH 24 | HERON LAKE OUTLET | 1.7 MI E OF JCT TH 60 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2017 | -- | 40.4 | 123.0 | Good | 98.0 | 32576 |
NBI report | CSAH 5 | JUD DITCH # 24 | 1.9 MI S OF JCT CSAH 4 | Prestressed Stringer/Multi-beam or girder | -- | 2018 | -- | 65.0 | 67.9 | Good | 98.0 | 32575 |