Kittson County

CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI report
Bridgehunter
TWP 310N BR TWO RIVERS0.3 MI E OF JCT CSAH 1Steel Truss - ThruClosed1907--48.950.9--20.2L4436
NBI reportTWP 115CO DITCH #221.5 MI W OF JCT CSAH 1Steel Stringer/Multi-beam or girder--1920--35.838.7Fair75.3L5837
NBI reportUS 75STREAM3.0 MI N OF HALLOCKConcrete Culvert (2 spans)--1924--9.822.6Fair86.11208
NBI reportUS 75STREAM1.0 MI N OF DONALDSONConcrete Culvert (2 spans)--1925--8.920.3Good95.14102
NBI reportUS 75DITCH4.5 MI N OF KENNEDYConcrete Culvert (2 spans)--1925--8.920.3Good97.24105
NBI reportCR 55STREAM0.2 MI W OF JCT CR 64Concrete Culvert (2 spans)--1926--9.822.6Fair84.06181
NBI reportTWP 91CO DITCH #221.0 MI S OF JCT CSAH 6Steel Stringer/Multi-beam or girder--1926--36.138.7Good80.3L4364
NBI reportCSAH 6N BR TWO RIVERS0.3 MI SE OF JCT CSAH 4Steel Stringer/Multi-beam or girder (3 spans)--1936--44.9107.9Fair74.15635
NBI reportUS 59STATE DITCH # 90, LAT #52.6 MI SE OF KARLSTADConcrete Culvert (2 spans)--1936--13.128.5Fair97.56178
NBI reportCSAH 28S BR TWO RIVERS (DAM)0.5 MI N OF JCT CSAH 10Concrete Girder and floorbeam system (3 spans)NR listed1937--23.368.2Fair53.77498
NBI reportUS 75STREAM1.2 MI N OF JCT TH 171Concrete Culvert (2 spans)--1937--12.126.9Fair98.22675
NBI reportTH 11DITCH4.9 MI E OF STATE LINEConcrete Culvert (2 spans)--1955--9.822.6Fair96.88905
NBI reportTH 11DITCH5.9 MI E OF STATE LINEConcrete Culvert (2 spans)--1955--15.735.1Fair85.68906
NBI reportUS 59LITTLE JOE RIVER7.1 MI N OF LANCASTERConcrete Culvert (2 spans)--1955--9.822.0Good97.86473
NBI reportUS 59S BR TWO RIVERSIN LAKE BRONSONConcrete Culvert (3 spans)--1963--16.146.3Fair97.135001
NBI reportUS 59MID BR TWO RIVERS3.5 MI NW OF LAKE BRONSOConcrete Culvert (2 spans)--1965--12.126.9Good97.935002
NBI reportCSAH 22S BR TWO RIVERS0.5 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder (3 spans)--1966--31.293.2Fair77.635502
NBI reportCSAH 30JOE RIVER1.0 MI W OF JCT CR 70Concrete Culvert (2 spans)--1967--10.236.7Good98.092271
NBI reportTWP 112JOE RIVER0.1 MI W OF JCT CR 70Concrete Culvert (2 spans)--1967--10.228.9Good97.092272
NBI reportCSAH 1STREAM1.0 MI N OF JCT CSAH 7Steel Culvert (2 spans)--1968--11.526.6Fair79.792274
NBI reportTH 175RED RIVER OF THE NORTHAT N DAKOTA STATE LINESteel Stringer/Multi-beam or girder (2 spans)--1968--180.11310.8Fair92.135005
NBI reportTH 175MID BR TWO RIVERS6.6 MI E OF JCT TH 75Prestressed Channel beam (3 spans)--1968--31.281.4Fair83.235506
NBI reportTH 175MID BR TWO RIVERS8.7 MI E OF JCT TH 75Prestressed Channel beam (3 spans)--1968--31.281.4Fair83.435507
NBI reportTWP 109JOE RIVER0.1 MI E OF JCT CSAH 16Concrete Culvert (3 spans)--1968--12.849.9Fair98.0L8830
NBI reportTWP 110JOE RIVER0.9 MI E OF JCT CSAH 16Wood Slab (3 spans)--1968--26.278.1Fair73.935505
NBI reportTWP 185JOE RIVER0.4 MI E OF JCT CSAH 16Wood Slab (3 spans)--1968--25.962.0Poor60.0L8832
NBI reportTH 175MID BR TWO RIVERS0.2 MI W OF JCT TH 59Prestressed Channel beam (3 spans)--1969--31.293.2Poor64.135508
NBI reportTH 175MID BR TWO RIVERS1.6 MI E OF JCT TH 75Concrete Culvert (2 spans)--1969--11.525.9Fair96.892720
NBI reportCSAH 20STREAM0.7 MI S OF JCT CSAH 7Concrete Culvert (3 spans)--1970--7.227.2Good98.089549
NBI reportCR 58N BR TWO RIVERS1.4 MI E OF JCT CSAH 16Wood Slab (3 spans)--1971--25.978.7Good90.792854
NBI reportCSAH 5DITCH1.2 MI N OF JCT TH 175Concrete Culvert (2 spans)--1971--10.223.3Good97.992851
NBI reportCSAH 16N BR TWO RIVERS1.5 MI N OF JCT TH 175Steel Culvert (2 spans)--1974--24.959.7Fair91.892100
NBI reportCSAH 10STATE DITCH # 95;LAT #23.8 MI E OF JCT CSAH 14Concrete Culvert (2 spans)--1976--11.534.5Good97.335514
NBI reportCSAH 10STATE DITCH # 951.1 MI E OF JCT CSAH 14Prestressed Stringer/Multi-beam or girder (3 spans)--1977--30.893.2Fair97.635513
NBI reportCSAH 1JUD DITCH # 100.3 MI S OF JCT CSAH 23Concrete Culvert (2 spans)--1978--11.530.8Good98.091728
NBI reportCSAH 13CO DITCH # 271.3 MI N OF JCT CSAH 7Concrete Culvert (3 spans)--1978--9.840.0Good98.035516
NBI reportTWP 224LITTLE JOE RIVER0.6 MI S OF JCT CSAH 6Concrete Culvert (2 spans)--1978--9.825.9Good98.091633
NBI reportTWP 255STREAM0.4 MI N OF JCT CR 61Concrete Culvert (3 spans)--1978--9.539.0Good98.091632
NBI reportCSAH 13JUD DITCH # 100.9 MI S OF JCT TH 11Concrete Culvert (2 spans)--1979--12.129.9Good98.091727
NBI reportCSAH 17STREAM1.5 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1979--8.522.6Good98.095171
NBI reportTWP 253S BR TWO RIVERS0.8 MI S OF JCT CSAH 22Prestressed Stringer/Multi-beam or girder (3 spans)--1979--40.0121.4Fair98.035517
NBI reportTWP 306S BR TWO RIVERS1.3 MI N OF JCT CSAH 7Prestressed Stringer/Multi-beam or girder (3 spans)--1979--35.4106.0Fair97.835519
NBI reportTWP 339STATE DITCH # 11.0 MI E OF JCT TH 75Concrete Culvert (2 spans)--1979--9.823.3Good98.095047
NBI reportTWP 345JUD DITCH # 100.4 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1979--14.131.5Good98.091907
NBI reportTWP 85S BR TWO RIVERS0.8 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder (3 spans)--1979--40.0121.4Fair86.735515
NBI reportCSAH 1STREAM1.9 MI S OF JCT CSAH 7Concrete Culvert (2 spans)--1980--12.129.5Good98.091917
NBI reportCSAH 8LITTLE JOE RIVER2.1 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1980--9.822.0Good98.095290
NBI reportTWP 232STREAM0.1 MI N OF JCT TH 175Concrete Culvert (2 spans)--1980--14.134.5Good98.095060
NBI reportTWP 240N BR TWO RIVERS0.9 MI N OF JCT CSAH 17Steel Culvert--1980--36.436.4Good92.895192
NBI reportTWP 246STREAM1.7 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--1980--10.227.2Good98.095207
NBI reportTWP 140STREAM2.0 MI W OF JCT CSAH 1Steel Culvert (2 spans)--1981--20.048.9Fair91.995341
NBI reportTWP 188STREAM1.5 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--1981--9.823.0Good97.095340
NBI reportTH 171RED RIVER OF THE NORTHAT N DAKOTA STATE LINESteel Stringer/Multi-beam or girder (18 spans)--1982--240.22080.2Fair94.835007
NBI reportTWP 103S BR TWO RIVERS1.4 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder (2 spans)--1982--77.8159.1Good94.835518
NBI reportTWP 38MID BR TWO RIVERS0.3 MI W OF JCT CSAH 15Concrete Culvert (2 spans)--1982--18.446.3Good98.095231
NBI reportCSAH 13CO DITCH # 81.0 MI S OF JCT CSAH 10Concrete Culvert (2 spans)--1983--14.134.5Good98.095318
NBI reportTWP 215N BR TWO RIVERS0.2 MI N OF JCT CSAH 4Steel Culvert (2 spans)--1984--21.751.2Good92.895230
NBI reportTWP 238S BR TWO RIVERS0.9 MI N OF JCT CSAH 22Prestressed Stringer/Multi-beam or girder (3 spans)--1984--37.4111.9Good92.635520
NBI reportTWP 240MID BR TWO RIVERS0.7 MI S OF JCT TH 175Prestressed Stringer/Multi-beam or girder--1984--53.255.1Good93.735521
NBI reportCSAH 23CO DITCH # 190.9 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1985--13.133.8Good98.095988
NBI reportTWP 227CO DITCH # 80.7 MI S OF JCT CSAH 10Concrete Culvert (2 spans)--1985--13.133.8Fair98.095989
NBI reportTWP 82STREAM2.7 MI S OF JCT TH 75Concrete Culvert (2 spans)--1985--9.825.6Good98.096067
NBI reportTWP 83STREAM1.4 MI W OF JCT CSAH 5Concrete Culvert (2 spans)--1985--10.226.2Good98.096066
NBI reportUTWN 29STREAM0.5 MI S OF JCT TH 175Concrete Culvert (2 spans)--1985--9.825.6Good98.096068
NBI reportCSAH 16STREAM0.2 MI E OF JCT TH 75Concrete Culvert (3 spans)--1986--10.241.3Good98.095507
NBI reportCSAH 2STREAM0.3 MI S OF JCT TH 11Concrete Culvert (2 spans)--1986--12.129.9Good98.096161
NBI reportCSAH 7CO DITCH # 270.1 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder (2 spans)--1986--40.784.0Good92.735523
NBI reportTH 175MID BR TWO RIVERS0.5 MI E OF JCT TH 75Steel Stringer/Multi-beam or girder (3 spans)--1986--91.9247.7Fair80.435006
NBI reportTWP 101STREAM2.2 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1986--7.921.7Good98.096125
NBI reportTWP 122STREAM0.4 MI W OF JCT TH 75Concrete Culvert (2 spans)--1986--8.523.6Good98.096133
NBI reportTWP 203STREAM0.8 MI S OF JCT CSAH 4Concrete Culvert (2 spans)--1986--8.523.6Good98.096132
NBI reportTWP 212STREAM0.9 MI S OF JCT CSAH 4Concrete Culvert (2 spans)--1986--12.129.9Fair98.096131
NBI reportTWP 227STATE DITCH # 12.1 MI S OF JCT CSAH 10Concrete Culvert (3 spans)--1986--9.835.1Good98.096186
NBI reportTWP 253STREAM0.4 MI N OF JCT CSAH 17Concrete Culvert (3 spans)--1986--8.539.0Good98.095990
NBI reportCSAH 5MID BR TWO RIVERS0.2 MI S OF JCT TH 175Prestressed Stringer/Multi-beam or girder (3 spans)--1987--27.983.7Good95.835526
NBI reportCSAH 5S BR TWO RIVERS0.3 MI N OF JCT CSAH 22Prestressed Stringer/Multi-beam or girder (3 spans)--1987--42.0126.6Good94.435527
NBI reportCSAH 5STREAM1.9 MI S OF JCT CSAH 7Concrete Culvert (2 spans)--1987--12.129.9Good98.096438
NBI reportCSAH 5STREAM0.5 MI N OF JCT CSAH 11Concrete Culvert (2 spans)--1987--9.825.6Good98.096496
NBI reportTWP 123CO DITCH # 22, LAT B1.0 MI N OF JCT CSAH 4Concrete Culvert (2 spans)--1987--10.226.2Good98.096136
NBI reportTWP 128JUD DITCH # 30.1 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1987--9.825.6Good98.096147
NBI reportTWP 196STREAM1.4 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--1987--14.436.7Good98.096103
NBI reportTWP 240STREAM0.3 MI S OF JCT CSAH 17Concrete Culvert (2 spans)--1987--9.525.3Good98.096168
NBI reportTWP 25STATE DITCH # 900.7 MI E OF JCT TH 11Concrete Culvert (2 spans)--1987--9.825.6Good98.096331
NBI reportTWP 347JUD DITCH # 101.1 MI S OF JCT TH 11Concrete Culvert (2 spans)--1987--12.129.5Good98.096352
NBI reportTWP 137CO DITCH # 311.3 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1988--12.129.5Good98.096184
NBI reportTWP 230MID BR TWO RIVERS0.1 MI S OF JCT TH 175Prestressed Stringer/Multi-beam or girder--1989--73.576.4Fair94.035522
NBI reportTWP 345JUD DITCH # 30.1 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1989--10.226.2Good98.096345
NBI reportTWP 136STREAM0.8 MI W OF JCT CSAH 13Concrete Culvert (2 spans)--1990--12.129.9Good98.096619
NBI reportTWP 144JUD DITCH # 100.4 MI W OF JCT CSAH 1Concrete Culvert (3 spans)--1990--16.161.4Good98.096344
NBI reportTWP 198MID BR TWO RIVERS0.4 MI N OF JCT TH 175Prestressed Stringer/Multi-beam or girder (4 spans)--1990--59.1242.8Fair97.035530
NBI reportTWP 227JUD DITCH # 101.0 MI S OF JCT TH 11Concrete Culvert (2 spans)--1990--12.129.5Good98.096348
NBI reportTWP 255STREAM0.3 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--1990--12.129.5Good98.096573
NBI reportTWP 303STREAM0.75 MI S OF JCT CSAH 17Concrete Culvert (2 spans)--1990--8.523.6Good98.096616
NBI reportCSAH 4STATE DITCH # 512.4 MI W OF JCT CSAH 24Concrete Culvert (2 spans)--1992--12.832.5Good98.096782
NBI reportTWP 196STREAM0.8 MI S OF JCT CSAH 7Concrete Culvert (3 spans)--1992--12.848.9Good98.096514
NBI reportTWP 208JUD DITCH # 101.0 MI S OF JCT TH 11Concrete Culvert (2 spans)--1992--13.834.1Good98.096346
NBI reportTWP 52STREAM0.6 MI E OF JCT TH 75Concrete Culvert (2 spans)--1992--8.523.0Good98.097068
NBI reportCR 53ROSEAU RIVER0.2 MI N OF JCT CSAH 4Concrete Slab (2 spans)--1993--61.0125.7Good98.035528
NBI reportTWP 212MID BR TWO RIVERS1.5 MI N OF JCT TH 175Prestressed Stringer/Multi-beam or girder (3 spans)--1993--57.1171.9Good96.035529
NBI reportTWP 238MID BR TWO RIVERS0.1 MI N OF JCT TH 175Prestressed Stringer/Multi-beam or girder (3 spans)--1993--28.285.3Good98.035531
NBI reportTWP 240STREAM0.7 MI N OF JCT TH 175Concrete Culvert (2 spans)--1993--7.921.7Good98.096887
NBI reportTWP 238N BR TWO RIVERS0.9 MI N OF JCT CSAH 4Concrete Culvert (2 spans)--1994--7.920.7Good94.097625
NBI reportTWP 346JUD DITCH # 100.9 MI S OF JCT TH 11Concrete Culvert (2 spans)--1994--12.129.5Good98.096347
NBI reportCSAH 34STREAM0.5 MI S OF JCT TH 175Concrete Culvert (2 spans)--1995--7.220.3Good98.097790
NBI reportTWP 231S BR TWO RIVERS0.2 MI S OF JCT CSAH 22Prestressed Stringer/Multi-beam or girder (3 spans)--1995--38.1114.2Good98.035524
NBI reportTWP 5STATE DITCH # 511.1 MI E OF JCT CSAH 24Concrete Culvert (2 spans)--1995--15.440.0Good98.097982
NBI reportTWP 83CO DITCH # 270.3 MI E OF JCT CSAH 13Concrete Culvert (2 spans)--1995--14.836.7Fair98.097322
NBI reportUS 75CO DITCH # 12.0 MI N OF KENNEDYConcrete Culvert (2 spans)--1995--12.126.9Good98.997952
NBI reportUS 75STATE DITCH # 13.0 MI N OF KENNEDYConcrete Culvert (2 spans)--1995--12.126.9Good98.997953
NBI reportUTWN 25MID BR TWO RIVERS0.5 MI E OF JCT CSAH 16Concrete Culvert (3 spans)--1995--12.146.3Fair85.097743
NBI reportUTWN 3SD DITCH # 95; LAT #10.9 MI N OF JCT CSAH 10Concrete Culvert (3 spans)--1995--12.549.9Good98.097981
NBI reportCSAH 13STATE DITCH # 12.0 MI S OF JCT CSAH 10Concrete Culvert (3 spans)--1996--10.241.3Good98.035J06
NBI reportTWP 60N BR TWO RIVERS1.5 MI N OF JCT CSAH 4Concrete Culvert (2 spans)--1996--12.129.5Fair98.097716
NBI reportCSAH 7STREAM0.5 MI E OF JCT CSAH 1Concrete Culvert (2 spans)--1997--9.825.6Good97.935J09
NBI reportTWP 206STREAM1.9 MI N OF JCT CSAH 7Concrete Culvert (4 spans)--1997--12.162.3Good98.035J05
NBI reportCSAH 23JD # 100.2 MI W OF JCT CSAH 1Concrete Culvert (3 spans)--1998--14.153.2Good98.035J04
NBI reportCSAH 4N BR TWO RIVERS2.0 MI N OF JCT CSAH 15Concrete Culvert (2 spans)--1998--9.826.6Good98.035J13
NBI reportCSAH 4STATE DITCH # 851.0 MI N OF JCT CSAH 15Concrete Culvert--1998--24.926.6Good98.096544
NBI reportTWP 227CO DITCH # 270.5 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--1998--12.129.5Good98.097664
NBI reportTWP 256STREAM0.8 MI S OF JCT TH 11Concrete Culvert (2 spans)--1998--10.226.6Good98.097723
NBI reportCSAH 24STATE DITCH # 512.6 MI S OF JCT CSAH 4Concrete Culvert (2 spans)--1999--9.825.9Good98.035J11
NBI reportCSAH 5JUD DITCH # 101.5 MI S OF JCT TH 11Concrete Culvert (2 spans)--1999--12.139.7Good98.096641
NBI reportTWP 247N BR TWO RIVERS1.2 MI N OF JCT CSAH 17Concrete Slab (3 spans)--1999--31.283.7Good98.035532
NBI reportCSAH 6LITTLE JOE RIVER0.6 MI SE OF JCT CSAH 1Concrete Culvert (2 spans)--2000--9.825.6Good97.835J17
NBI reportTWP 122N BR TWO RIVERS1.2 MI SE OF JCT CSAH 4Prestressed Stringer/Multi-beam or girder (3 spans)--2000--63.7191.6Good98.035533
NBI reportTWP 152JUD DITCH # 100.3 MI E OF JCT TH 75Concrete Culvert (2 spans)--2000--12.129.5Good98.035J07
NBI reportTWP 485JUD DITCH # 100.5 MI N OF S CO LINEConcrete Culvert (2 spans)--2000--12.129.5Good98.035J08
NBI reportTWP 253MID BR TWO RIVERS0.2 MI S OF JCT TH 175Concrete Slab (3 spans)--2001--29.981.0Good100.035525
NBI reportTOWNSHIP RD 137COUNTY DITCH # 41.5 MI SO OF JCT CSAH 7Concrete Culvert (2 spans)--2002--9.825.6Good100.035J23
NBI reportTOWNSHIP RD 432STATE DITCH # 950.2 MI N OF JCT CSAH 10Concrete Culvert (2 spans)--2002--9.825.6Good100.035J24
NBI reportTOWNSHIP RD 56COUNTY DITCH # 41.5 MI SO OF JCT CSAH 7Concrete Culvert (2 spans)--2002--9.825.6Good100.035J22
NBI reportTNSP RD 246COUNTY DITCH #40.6 MI NO OF JCT CR 61Concrete Culvert (2 spans)--2003--11.529.9Good98.035J21
NBI reportCSAH 30JOE RIVER1.9 MI N OF JCT CSAH 6Concrete Culvert (2 spans)--2004--11.227.9Good99.035J35
NBI reportCSAH 7STREAM1.2 MI W OF JCTCSAH 1Concrete Culvert (3 spans)--2004--12.144.6Good97.935J30
NBI reportTWP 209STREAM1.7 MI N OF JCT CSAH 7Concrete Culvert (2 spans)--2004--9.824.3Good100.035J32
NBI reportCR 65N BR TWO RIVERS1.4 MI W OF JCT TH 75Prestressed Stringer/Multi-beam or girder (3 spans)--2006--65.3198.8Good98.035534
NBI reportTH 171RED RIVER OVERFLOW0.7 MI W OF JCT 75Steel Stringer/Multi-beam or girder (7 spans)--2006--78.1519.4Good99.535010
NBI reportTWP 85COULEE0.1 MI E JCT CSAH 5Concrete Culvert (2 spans)--2006--10.226.6Good100.035J37
NBI reportUS 75N BR TWO RIVERS5.2 MI N OF JCT TH 175Prestressed Stringer/Multi-beam or girder (2 spans)--2006--72.2147.0Good99.335012
NBI report5 ST (CSAH 39)CD # 270.1 MI E JCT US 75Concrete Culvert (2 spans)--2007--14.129.9Good100.035J38
NBI reportTWP 65SD # 843.0 I E JCT US 59Concrete Culvert (2 spans)--2007--8.921.0Good100.035J44
NBI reportUS 75JUD DITCH @ 101.0 MI S OF DONALDSONConcrete Culvert (2 spans)--2007--12.127.6Good99.935X02
NBI reportCSAH 1N BR TWO RIVERS1.0 MI S OF JCT CSAH 4Concrete Slab (3 spans)--2009--54.1140.4Good98.035536
NBI reportTH 175CO DITCH #216.6 MI W OF HALLOCKConcrete Culvert (2 spans)--2009--12.827.6Good95.235X04
NBI report280TH AVES BR TWO RIVERS1.2 MI S OF JCT CSAH 22Prestressed Stringer/Multi-beam or girder (3 spans)--2010--45.3137.1Good98.035535
NBI reportTH 11RED RIVER OF THE NORTHAT N DAKOTA STATE LINESteel Stringer/Multi-beam or girder (37 spans)--2010--250.04090.1Good98.135011
NBI report240TH AVELITTLE JOE RIVER0.4 MI S OF JCT CSAH 6Concrete Culvert (2 spans)--2011--9.824.3Good97.935J48
NBI report360TH AVEMID BR TWO RIVERS2.4 MI S OF JCT CR 60Concrete Culvert (2 spans)--2011--10.224.9Good97.935J50
NBI reportCSAH 1KENNEDY COULEE1.8 MI N OF JCT CSAH 7Prestressed Stringer/Multi-beam or girder (3 spans)--2012--61.4184.4Good97.935537
NBI reportUS 75MID BR TWO RIVERS1.0 MI N OF HALLOCKPrestressed Stringer/Multi-beam or girder (3 spans)--2012--69.9282.2Good91.735013
NBI reportUS 75KENNEDY #6 DITCH7.2 MI N OF CO LINEConcrete Culvert (3 spans)--2012--12.142.7Good98.635X06
NBI reportCSAH 6CO DITCH # 221.5 MI W OF JCT CSAH 1Concrete Culvert (2 spans)--2013--9.824.3Good97.935J53
NBI reportTH 175MID BR TWO RIVERS3.4 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder--2014--68.971.2Good98.935003
NBI reportTH 175MID BR TWO RIVERS3.7 MI E OF JCT TH 75Prestressed Stringer/Multi-beam or girder--2014--66.969.2Good98.935004
NBI reportUS 59N BR TWO RIVERSIN LANCASTERPrestressed Stringer/Multi-beam or girder--2014--98.8101.1Good99.635017
NBI reportCSAH 4N BR TWO RIVERS1.4 MI W OF JCT CSAH 1Prestressed Stringer/Multi-beam or girder (3 spans)--2015--65.6198.2Good98.035538
NBI report335TH AVEMID BR TWO RIVERS0.1 MI S OF JCT TH 175Concrete Slab--2016--42.043.6Good97.035539
NBI reportUS 59DITCH # 843.3 MI N OF LANCASTERConcrete Culvert (2 spans)--2016--9.824.0Good99.635X10