| Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID |
NBI report | TH 21 | STREAM | 0.1 MI N OF JCT TH 169 | Concrete Culvert (2 spans) | -- | -- | -- | 9.8 | 22.3 | Fair | 83.0 | 8350 |
NBI report | ABERDEEN AVE | W BR RAVEN STREAM | 0.8 MI S OF JCT CSAH 4 | Concrete Culvert (2 spans) | -- | 1932 | -- | 11.8 | 26.2 | Fair | 94.8 | L3044 |
NBI report | MSAS 115(123RD ST) | CREDIT RIVER | 0.2 MI S OF JCT TH13 | Concrete Culvert (2 spans) | -- | 1938 | -- | 10.5 | 23.0 | Fair | 88.8 | 5263 |
NBI report | CP RAIL | MN 13 | 1.4 MI E OF JCT TH 101 | Steel Stringer/Multi-beam or girder | -- | 1939 | -- | 41.0 | -- | -- | -- | 5528 |
NBI report | TH 13 | CREDIT RIVER | 1.7 MI E OF JCT TH 101 | Concrete Culvert (2 spans) | -- | 1939 | -- | 9.8 | 22.3 | Fair | 61.7 | 5829 |
NBI report | US 169 | STREAM | 2.6 MI S OF JCT TH 41 | Concrete Culvert (2 spans) | -- | 1953 | -- | 10.5 | 22.3 | Fair | 68.3 | 8829 |
NBI report | US 169 | SAND CREEK | 0.3 MI E OF JCT TH 282 | Steel Stringer/Multi-beam or girder | -- | 1954 | -- | 80.1 | 84.6 | Good | 97.9 | 6802 |
NBI report | US 169 | DITCH | 0.1 MI E OF JCT TH 21 | Concrete Culvert (2 spans) | -- | 1954 | -- | 10.8 | 23.6 | Fair | 79.6 | 8850 |
NBI report | TH 282 | SAND CREEK | 0.4 MI SE OF JCT TH 169 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | -- | 43.0 | 128.9 | Fair | 99.3 | 6859 |
NBI report | US 169 | UP RR | 0.1 MI W OF JCT TH 21 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | -- | 53.2 | 132.9 | Good | 95.7 | 6803 |
NBI report | US 169 | TH 21 | AT JCT TH 21 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | -- | 60.0 | 159.5 | Fair | 66.0 | 6804 |
NBI report | TH 21 | UP RR | 0.5 MI S OF JCT TH 282 | Concrete Slab (5 spans) | -- | 1957 | -- | 35.4 | 177.5 | Fair | 63.7 | 9123 |
NBI report | TH 21 | Sand Creek | 0.7 MI S OF JCT TH 282 | Concrete Girder and floorbeam system (3 spans) | -- | 1958 | -- | 60.0 | 160.4 | Fair | 67.7 | 9124 |
NBI report | VARNER ST | SAND CREEK | 0.1 MI S OF JCT TH 282 | Prestressed Stringer/Multi-beam or girder | -- | 1962 | -- | 78.1 | 82.0 | Good | 59.7 | 7286 |
NBI report | CSAH 2 | I 35 | 7.2 MI N OF JCT TH 19 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1963 | -- | 66.9 | 212.0 | Fair | 74.3 | 70801 |
NBI report | DREXEL AVE | SAND CREEK | 0.3 MI N OF JCT CR 2 | Wood Slab (2 spans) | -- | 1963 | -- | 21.0 | 44.0 | Poor | 63.8 | 70502 |
NBI report | 225 ST | I 35 | 10.7 MI N OF JCT TH 19 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 67.3 | 209.0 | Fair | 72.9 | 70805 |
NBI report | 230 ST W | RAVEN STREAM | 0.8 MI E OF JCT TH21 | Wood Slab (3 spans) | -- | 1964 | -- | 25.6 | 62.0 | Fair | 96.9 | 70503 |
NBI report | CR 62 | I 35 | 8.7 MI N OF JCT TH 19 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1964 | -- | 67.3 | 212.3 | Fair | 73.4 | 70802 |
NBI report | 235 ST W | SAND CREEK | 0.5 MI W OF JCT CR 89 | Wood Slab (2 spans) | -- | 1965 | -- | 23.0 | 47.9 | Good | 100.0 | 70505 |
NBI report | 260 ST W | SAND CREEK | 0.5 MI W OF JCT CSAH 15 | Wood Slab (3 spans) | -- | 1965 | -- | 18.0 | 54.1 | Fair | 96.7 | 70504 |
NBI report | SAWMILL RD | SAND CREEK | 0.2 MI SE OF TH21 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1967 | -- | 37.4 | 80.1 | Good | 95.4 | 70506 |
NBI report | REDWING AVE | SAND CREEK | 0.2 MI N OF JCT TH19 | Wood Slab (3 spans) | -- | 1968 | -- | 18.0 | 54.1 | Fair | 96.7 | 70507 |
NBI report | TH 13 | Porter Creek | 4.6 MI S OF JCT TH 282 | Concrete Culvert (2 spans) | -- | 1971 | -- | 14.1 | 32.8 | Fair | 93.9 | 91226 |
NBI report | DELMAR AVE | W BR RAVEN STREAM | 0.1 MI S OF JCT CSAH 4 | Concrete Culvert (2 spans) | -- | 1973 | -- | 11.5 | 23.0 | Good | 99.2 | 93000 |
NBI report | TWP 4 | W BR RAVEN STREAM | 0.1 MI E OF JCT CSAH 11 | Concrete Culvert (2 spans) | -- | 1973 | -- | 11.5 | 23.0 | Good | 100.0 | 93002 |
NBI report | TWP 58 | PORTER CREEK; CD # 5 | 0.6 MI W OF JCT CR 64 | Concrete Culvert (3 spans) | -- | 1977 | -- | 12.8 | 44.3 | Good | 100.0 | 91591 |
NBI report | TWP 365 | CREDIT RIVER | 0.4 MI E OF JCT CR 75 | Concrete Culvert (2 spans) | -- | 1978 | -- | 11.5 | 25.9 | Good | 100.0 | 91699 |
NBI report | 220 ST E | PORTER CREEK | 0.4 MI W OF JCT TH 13 | Concrete Culvert (2 spans) | -- | 1979 | -- | 14.1 | 35.4 | Good | 98.7 | 95062 |
NBI report | SYNDICATE | SAND CREEK | 0.1 MI NE OF JCT CSAH 9 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 49.9 | 131.2 | Fair | 86.9 | 70509 |
NBI report | SYNDICATE | SAND CREEK | 0.4 MI N OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 50.2 | 150.9 | Good | 99.9 | 70510 |
NBI report | E 4TH AVE | DRAINAGE WAY | 0.2 MI E OF JCT CSAH 17 | Concrete Culvert | -- | 1980 | -- | 21.0 | 21.0 | Good | 84.6 | R0718 |
NBI report | MCCOLL DR | CP RAIL | 0.1 MI E OF JCT CSAH 31 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1982 | -- | 59.7 | 183.7 | Good | 95.8 | 70511 |
NBI report | TWP 172(XANADU AV) | PORTER CREEK | 1.3 MI S OF JCT CSAH 10 | Concrete Culvert (2 spans) | -- | 1985 | -- | 12.8 | 33.1 | Good | 98.3 | 91868 |
NBI report | 245 ST W | SAND CREEK | 0.2 MI E OF JCT CSAH 15 | Concrete Culvert (2 spans) | -- | 1986 | -- | 14.1 | 34.5 | Good | 99.0 | 96006 |
NBI report | MUN 99(LORDS ST) | PRIOR LAKE | W OF MARTINSON ISLAND | Wood Slab (3 spans) | -- | 1986 | -- | 24.0 | 71.9 | Fair | 81.0 | 70513 |
NBI report | TH 25 | UP RR | 1.8 MI N OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 65.0 | 198.5 | Good | 95.1 | 70027 |
NBI report | HARLOW AVE | SAND CREEK | 0.3 MI S OF JCT CSAH 8 | Concrete Culvert (2 spans) | -- | 1989 | -- | 10.2 | 25.6 | Good | 97.9 | 96790 |
NBI report | 173 ST W | SAND CREEK | 0.3 MI W OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 41.3 | 122.4 | Fair | 93.3 | 70514 |
NBI report | BASELINE AVE | CO DITCH # 2 | 0.7 MI S OF JCT CR 2 | Concrete Culvert (2 spans) | -- | 1990 | -- | 11.8 | 30.5 | Good | 100.0 | 96761 |
NBI report | TH 901B WB | UP RR | 1.3 MI W OF JCT TH 13 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 100.1 | 273.0 | Fair | 88.0 | 70004 |
NBI report | TWP 53 | ROBERT CREEK | 0.5 MI N OF JCT TH 169 | Concrete Culvert (2 spans) | -- | 1990 | -- | 11.5 | 29.5 | Good | 100.0 | 96762 |
NBI report | CSAH 21 | PRIOR LAKE | 1.4 MI NW OF JCT TH 13 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 40.4 | 103.4 | Good | 69.8 | 70517 |
NBI report | TH 801B EB | County 101 TH 169R | AT THE JCT TH 169R | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1991 | -- | 170.0 | 316.9 | Good | 100.0 | 70009 |
NBI report | TH 901B EB | UP RR | 1.3 MI W OF JCT TH 13 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 67.3 | 207.0 | Fair | 95.0 | 70006 |
NBI report | CSAH 101 | MINNESOTA RIVER | 0.1 MI N OF JCT CR 69 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1992 | -- | 107.9 | 815.0 | Good | 87.8 | 70002 |
NBI report | MSAS 122(RVR XING) | CREDIT RIVER | 0.3 MI N OF HANREHAN LK | Concrete Culvert | -- | 1992 | -- | 44.0 | 44.0 | Good | 99.8 | 70531 |
NBI report | CANTERBURY DR | STREAM | 0.1 MI N OF JCT TH 169 | Concrete Culvert (2 spans) | -- | 1993 | -- | 7.9 | 21.7 | Good | 78.4 | 97223 |
NBI report | CANTERBURY DR | STREAM | 0.1 MI S OF JCT TH 169 | Concrete Culvert (2 spans) | -- | 1993 | -- | 8.2 | 22.0 | Good | 78.4 | 97224 |
NBI report | CSAH 17 | US 169 | 4.2 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 108.9 | 217.9 | Good | 92.5 | 70014 |
NBI report | FIRST ST | PED WALK | 0.1 MI W OF JCT CSAH 101 | Concrete Culvert | -- | 1993 | -- | 34.1 | 36.1 | Good | 80.2 | 97310 |
NBI report | NEWPORT AVE | PORTER CREEK; CD # 5 | 1.7 MI E; N OF JCT TH 13 | Concrete Culvert (3 spans) | -- | 1993 | -- | 15.1 | 57.4 | Fair | 87.0 | 97555 |
NBI report | QUAKER AVE | STREAM | 0.1 MI NW OF JCT TH 169 | Concrete Culvert (2 spans) | -- | 1993 | -- | 10.8 | 27.6 | Good | 90.3 | 97464 |
NBI report | US 169 NB | CSAH 83 | 6.2 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 139.8 | 203.1 | Good | 98.1 | 70039 |
NBI report | US 169 NB | TH 801B | 5.7 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 138.1 | 256.6 | Good | 97.8 | 70519 |
NBI report | US 169 NB | County 101 EB (Savage) | 5.8 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder | -- | 1993 | -- | 111.9 | 116.5 | Good | 98.3 | 70521 |
NBI report | US 169 SB | CSAH 83 | 6.2 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 139.8 | 203.1 | Fair | 86.8 | 70040 |
NBI report | US 169 SB | TH 801B | 5.7 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 138.5 | 257.9 | Good | 97.8 | 70520 |
NBI report | US 169 SB | County 101EB (Savage) | 5.8 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder | -- | 1993 | -- | 111.9 | 116.5 | Good | 98.3 | 70522 |
NBI report | US 169 SB OFF RAMP | CSAH 101 | 5.7 MI SW OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1993 | -- | 116.5 | 228.0 | Fair | 99.5 | 70518 |
NBI report | VIERLING DR | RELIEF WATERWAY | 0.32 MI E OF JCT CR 79 | Concrete Culvert (2 spans) | -- | 1993 | -- | 7.9 | 21.3 | Good | 83.3 | R0706 |
NBI report | CSAH 18 NB | TH 169R | 0.8 MI E OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 119.8 | 231.6 | Fair | 98.9 | 70529 |
NBI report | CSAH 18 SB | TH 169R | 0.8 MI E OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 119.8 | 231.6 | Good | 98.9 | 70530 |
NBI report | Stagecoach Rd | TH 169R | 1.0 MI E OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 108.9 | 217.2 | Good | 99.9 | 70008 |
NBI report | US 169 | DEANS LAKE OUTLET | 7.6 MI E OF JCT TH 41 | Concrete Culvert (2 spans) | -- | 1994 | -- | 12.5 | 30.8 | Good | 85.0 | 97278 |
NBI report | US 169 | STREAM | 6.5 MI E OF JCT TH 41 | Concrete Culvert (2 spans) | -- | 1994 | -- | 12.1 | 29.5 | Good | 78.1 | 97445 |
NBI report | US 169 EB | TH 169R WB | 7.1 MI SW OF JCT TH 494 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 212.0 | 452.8 | Good | 98.3 | 70525 |
NBI report | US 169 EB | CSAH 18 | 6.0 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 94.8 | 191.3 | Good | 98.3 | 70527 |
NBI report | US 169 NB | MSAS 131 | 5.9 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 170.0 | 179.5 | Good | 94.1 | 70037 |
NBI report | US 169 NB | UP RR; CSAH 18 | 5.9 MI SW OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 165.0 | 296.6 | Fair | 98.3 | 70523 |
NBI report | US 169 SB | MSAS 131 | 5.9 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 170.0 | 179.5 | Good | 94.1 | 70038 |
NBI report | US 169 SB | UP RR; CSAH 18 | 5.9 MI SW OF JCT TH 494 | Steel Stringer/Multi-beam or girder | -- | 1994 | -- | 190.0 | 197.5 | Good | 98.3 | 70524 |
NBI report | US 169 WB | TH 169R WB | 7.1 MI SW OF JCT TH 494 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 225.1 | 481.0 | Good | 97.3 | 70526 |
NBI report | US 169 WB | CSAH 18 | 6.0 MI SW OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 94.8 | 191.3 | Good | 98.3 | 70528 |
NBI report | CR 79 | US 169 | 3.4 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 108.9 | 215.6 | Fair | 88.6 | 70013 |
NBI report | CSAH 15 | US 169 | 2.3 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 132.9 | 242.1 | Fair | 94.7 | 70011 |
NBI report | MSAS 117 | US 169 | 2.8 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 105.0 | 209.0 | Fair | 99.9 | 70012 |
NBI report | SARAZIN ST | RELIEF WATERWAY | 0.8 MI N OF JCT CSAH 16 | Concrete Culvert (2 spans) | -- | 1995 | -- | 12.8 | 30.5 | Good | 99.6 | R0713 |
NBI report | US 169 | STREAM | 1.8 MI E OF JCT TH 41 | Concrete Culvert (2 spans) | -- | 1995 | -- | 10.5 | 27.2 | Fair | 84.0 | 97602 |
NBI report | BRIDGEWATER DR | CREDIT RIVER | 0.2 MI N OF HANREHAM LK | Concrete Culvert | -- | 1996 | -- | 34.5 | 35.1 | Good | 99.9 | 70J04 |
NBI report | CSAH 21 | CREDIT RIVER | 1.4 MI SE OF JCT CSAH 27 | Concrete Culvert (2 spans) | -- | 1996 | -- | 9.8 | 23.6 | Good | 82.3 | 97573 |
NBI report | INDEPENDANCE AVE | EAGLE CREEK | 0.2 MI S OF 126TH ST | Concrete Culvert | -- | 1996 | -- | 44.0 | 44.9 | Good | 99.9 | 70J05 |
NBI report | 126 ST | EAGLE CREEK | 0.3 MI W OF JCT TH 13 | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 100.1 | 101.7 | Good | 99.7 | 70534 |
NBI report | 128 ST | E BR EAGLE CREEK | 0.3 MI W OF JCT TH 13 | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 109.9 | 111.6 | Good | 85.9 | 70533 |
NBI report | TH 41 | Minnesota River Overflow | 0.8 MI N OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 82.4 | 249.7 | Good | 81.0 | 70041 |
NBI report | MCCOLL DR | CREDIT RIVER | 0.8 MI E OF JCT CSAH 27 | Concrete Culvert (2 spans) | -- | 1999 | -- | 13.8 | 33.1 | Good | 96.5 | 70J03 |
NBI report | TH 21 | Raven Stream | 4.1 MI N OF JCT TH 19 | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 67.9 | 69.6 | Good | 97.0 | 70042 |
NBI report | 255 ST W | E Br Raven Stream | 1.0 MI W OFJCT TH 21 | Concrete Culvert (2 spans) | -- | 2000 | -- | 9.8 | 25.6 | Good | 100.0 | 70J14 |
NBI report | ORCHARD ST | STREAM | 0.3 MI E OF JCT CSAH 5 | Concrete Culvert (2 spans) | -- | 2000 | -- | 9.8 | 24.3 | Good | 98.0 | 70J59 |
NBI report | 240 ST E | Trib to Porter Creek | 0.6 mi W of jct CSAH 27 | Concrete Culvert (2 spans) | -- | 2001 | -- | 9.8 | 25.6 | Good | 100.0 | 70J15 |
NBI report | PED E OF CSAH 17 | US 169 | 4.2 MI E OF JCT TH 41 | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 122.1 | -- | -- | -- | 70536 |
NBI report | PED W OF CR 79 | US 169 | 3.4 MI E OF JCT TH 14 | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 122.1 | -- | -- | -- | 70539 |
NBI report | QUAKER AVE | Minnesota River | At N County Line | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2002 | -- | 140.1 | 564.7 | Good | 90.6 | 70532 |
NBI report | REDWING AVE | CO DITCH # 2 | 0.1 MI S OF JCT CSAH 2 | Concrete Culvert (2 spans) | -- | 2003 | -- | 9.8 | 25.6 | Good | 99.9 | 70J19 |
NBI report | ALYSHEBA RD | RELIEF WATERWAY | 0.31 MI N OF JCT CSAH 16 | Concrete Culvert (4 spans) | -- | 2004 | -- | 7.9 | 39.4 | Good | 100.0 | R0707 |
NBI report | HARALSON DR | RELIEF WATERWAY | 0.3 MI E JCT CSAH 3 | Concrete Culvert (2 spans) | Closed | 2004 | -- | 11.2 | 27.9 | Good | 93.0 | 70J56 |
NBI report | 270 ST W | SAND CREEK | 0.4 MI W OF JCT CR 89 | Concrete Culvert (2 spans) | -- | 2005 | -- | 10.2 | 22.3 | Good | 100.0 | 70J20 |
NBI report | CSAH 5 | MINNESOTA RIVER | 0.5 MI NW OF JCT CSAH 6 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2005 | -- | 149.9 | 603.7 | Good | 97.4 | 70535 |
NBI report | IRR BIA RTE 0001 | SHAKOPEE DRAINAGE | SHAKOPEE | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 96.1 | 200.1 | Good | 99.9 | 0000F57411T0001 |
NBI report | TH 25 NB | US 169; RAMPS | AT THE JCT OF TH 169; 25 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 203.4 | 417.0 | Fair | 74.0 | 70043 |
NBI report | TH 25 SB | US 169; RAMPS | AT THE JCT OF TH 169; 25 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 203.4 | 417.0 | Fair | 84.0 | 70044 |
NBI report | FOUNTAIN HILLS DR | CREEK | 0.3 M SE OF JCT CSAH 42 | Concrete Culvert | -- | 2006 | -- | 41.3 | 49.9 | Good | 100.0 | R0765 |
NBI report | QUENTIN | CREDIT RIVER | 0.7 MI N OF CSAH 16 | Concrete Slab (2 spans) | -- | 2006 | -- | 34.1 | 69.9 | Good | 98.7 | 70547 |
NBI report | XEON AVE | PORTER CREEK | 0.3 MIN OF JCT CSAH 8 | Concrete Culvert (2 spans) | -- | 2006 | -- | 9.8 | 24.3 | Good | 99.9 | 70J26 |
NBI report | 154 ST | CREDIT RIVER | 0.2 MI E JCT CSAH 27 | Concrete Culvert (2 spans) | -- | 2007 | -- | 9.8 | 23.3 | Good | 98.1 | 70J36 |
NBI report | DREXEL AVE | SAND CREEK | 0.4 MI S JCT CR 2 | Concrete Culvert (2 spans) | -- | 2007 | -- | 12.5 | 30.8 | Good | 99.7 | 70J21 |
NBI report | HARLOW AVE | PORTER CREEK | 0.9 MI N JCT CSAH 8 | Concrete Culvert (2 spans) | -- | 2007 | -- | 11.5 | 29.5 | Good | 99.9 | 70J30 |
NBI report | PIKE LAKE RD | STREAM | 0.25 MI N OF CSAH 16 | Concrete Culvert (2 spans) | -- | 2007 | -- | 12.5 | 28.9 | Good | 99.9 | 70J29 |
NBI report | CSAH 101 | STREAM | 0.2 MI E OF JCT CSAH 17 | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 109.9 | 113.9 | Good | 98.6 | 70542 |
NBI report | CHURCH AVE | STREAM | 0.4 MI S OF JCT CSAH 4 | Concrete Culvert (2 spans) | -- | 2009 | -- | 11.2 | 26.9 | Good | 99.4 | 70J42 |
NBI report | CSAH 21 | UNNAMED | 0.3 M N OF CSAH 16 | Concrete Culvert (2 spans) | -- | 2009 | -- | 14.1 | 32.5 | Good | 83.6 | 70J44 |
NBI report | 220TH ST W | SAND CREEK | 1.1 MI E OF JCT TH 21 | Prestressed Stringer/Multi-beam or girder | -- | 2010 | -- | 96.1 | 102.4 | Good | 99.3 | 70545 |
NBI report | OAK RIDGE TRAIL | UNNAMED | 0.1 MI N OF CSAH 16 | Concrete Culvert (2 spans) | -- | 2010 | -- | 12.1 | 25.3 | Good | 100.0 | 70J50 |
NBI report | PED TRAIL | US 169 | 39 FEET E OF CR 77 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2010 | -- | 123.0 | 245.4 | Good | 0.0 | 70550 |
NBI report | CSAH 17 | CSAH 42 (140TH ST NW) | 1.5 MI W JCT CSAH42; 83 | Prestressed Stringer/Multi-beam or girder | -- | 2011 | -- | 136.5 | 136.5 | Good | 97.2 | 70552 |
NBI report | 123RD STREET | CREDIT RIVER | 0.2 MI S OF JCT TH13 | Prestressed Culvert | -- | 2012 | -- | 27.9 | 27.9 | Good | 84.7 | 70J48 |
NBI report | 250 ST E | PORTER CREEK | 0.1 MI E OF JCT CSAH 23 | Concrete Culvert (2 spans) | -- | 2012 | -- | 12.1 | 28.5 | Good | 99.9 | 70J32 |
NBI report | CSAH 101 | PRIOR LAKE OUTLET CHN | 0.7 MI N OF JCT CSAH 16 | Concrete Culvert (2 spans) | -- | 2012 | -- | 12.1 | 28.5 | Good | 78.7 | 70J49 |
NBI report | CSAH23 | PORTER CREEK | 0.1 MI N OF JCT CSAH56 | Concrete Culvert (2 spans) | -- | 2012 | -- | 12.5 | 29.5 | Fair | 98.0 | 70J31 |
NBI report | RICE ST S | SAND CREEK | 0.1 MI S OF JCT TH 282 | Concrete Slab (3 spans) | -- | 2012 | -- | 36.1 | 109.6 | Good | 100.0 | 70551 |
NBI report | TH 101 EB | TH 13 | JCT TH101 AND TH13 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 2012 | -- | 126.0 | 1011.2 | Fair | 96.0 | 70003 |
NBI report | UNION TR | STREAM | 2.0 MI W OF BELLE PLAINE | Prestressed Stringer/Multi-beam or girder | -- | 2012 | -- | 35.4 | 36.7 | Good | 95.8 | 70548 |
NBI report | CSAH 69 | US 169 | 1.25 M E OF JCT TH41 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2014 | -- | 121.7 | 244.1 | Fair | 100.0 | 70007 |
NBI report | CSAH 8 | PORTER CREEK | 0.2 MI NW OF JCT CSAH 23 | Concrete Culvert | -- | 2014 | -- | 27.9 | 29.9 | Good | 98.8 | 70J52 |
NBI report | QUARRY LAKE PK ENT | PRIOR LAKE OUTLET CHN | 0.1MI E OF INNOVATION BLV | Concrete Culvert (2 spans) | -- | 2014 | -- | 14.1 | 31.2 | Good | 95.0 | 70J60 |
NBI report | VALLEY VIEW DR | CREDIT RIVER | 0.3 M N OF JCT 154TH ST W | Prestressed Stringer/Multi-beam or girder | -- | 2014 | -- | 80.1 | 82.0 | Good | 99.9 | 70553 |
NBI report | ST BENEDICT RD | W BR RAVEN STREAM | 0.5 MI E OF JCT CSAH 11 | Concrete Culvert (3 spans) | -- | 2015 | -- | 12.1 | 47.6 | Good | 100.0 | 70J61 |
NBI report | ENTERPRISE DR | US 169 | 0.5 MI N OF JCT TH 169 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2016 | -- | 105.0 | 212.0 | Good | 97.5 | 70031 |
NBI report | CSAH 8 | PORTER CREEK | 1.2 MI SE OF JCT TH 13 | Concrete Slab | -- | 2018 | -- | 40.0 | 41.7 | Good | 98.2 | 70554 |