NBI report | MUNI 104 | MISSISSIPPI RIVER | 0.1 MI W OF JCT CSAH 22 | Steel Movable - Swing | Closed ~ NR eligible | 1895 | -- | 442.0 | 1661.5 | -- | 0.0 | 5600 |
NBI report | FOREST ROAD N | DITCH | 0.2 MI S OF 180 ST | Concrete Slab | -- | 1920 | -- | 20.0 | 23.0 | Fair | 79.3 | L8186 |
NBI report Bridgehunter | 26(PUTNAM BD S) | VALLEY CREEK | 0.2 MI N OF JCT CSAH 21 | Steel Stringer/Multi-beam or girder | Closed | 1924 | -- | 23.6 | 25.6 | Poor | 32.3 | L8173 |
NBI report | US 61 | HARDWOOD CREEK | 3.3 MI N OF HUGO | Concrete Culvert (2 spans) | -- | 1925 | -- | 9.8 | 22.3 | Good | 97.1 | 6198 |
NBI report Bridgehunter | MNTH 36 | ST CROIX RIVER; PARK RD | AT WISONSIN STATE LINE | Steel Movable - Lift | NR listed | 1930 | -- | 143.7 | 1051.6 | Poor | 17.8 | 4654 |
NBI report Bridgehunter | GREY CLOUD TR | CHANNEL | 1.2 MI SE OF JCT CR75 | Steel Truss - Thru | -- | 1933 | -- | 75.1 | 127.6 | Poor | 50.0 | L8159 |
NBI report | CSAH19-ChemoliteRd | US 61 | 3.1 MI NW OF JCT TH 95 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1958 | -- | 53.5 | 178.2 | Good | 92.0 | 9071 |
NBI report | TH 95 | UP RR | 2.1 MI S OF BAYPORT | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | -- | 100.1 | 259.9 | Fair | 78.8 | 9391 |
NBI report | I 494 EB | CSAH 25 (CENTURY AVE) | 2.0 MI NE OF JCT TH 61 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 2003 | 77.4 | 199.2 | Fair | 97.0 | 9776 |
NBI report | I 494 WB | CSAH 25 (CENTURY AVE) | 2.0 MI NE OF JCT TH 61 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 2009 | 77.4 | 203.8 | Fair | 95.0 | 9775 |
NBI report | 4th Street North | I 694 | 0.3 MI N OF JCT TH 94 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1966 | -- | 74.2 | 220.5 | Fair | 82.0 | 82817 |
NBI report | I 694 NB | I 94; COLLECTOR ROADS | AT JCT TH 694 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | 1984 | 90.9 | 270.4 | Poor | 70.5 | 82832 |
NBI report | I 694 SB | I 94; COLLECTOR ROADS | AT JCT TH 694 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1966 | 1984 | 90.9 | 270.4 | Poor | 71.7 | 82831 |
NBI report | 15th Street North | I 694 | 1.5 MI N OF JCT TH 94 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 66.9 | 214.6 | Fair | 80.0 | 82803 |
NBI report | 40th Street North | I 694 | 1.8 MI S OF JCT TH 36 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 67.3 | 212.3 | Fair | 82.0 | 82816 |
NBI report | CSAH 10 | I 694 | 1.0 MI N OF JCT TH 94 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 80.4 | 226.4 | Fair | 91.0 | 82818 |
NBI report | CSAH 6 | I 694 | 2.7 MI N OF JCT TH 94 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 77.4 | 249.4 | Fair | 81.0 | 82804 |
NBI report | I 694 NB | 50TH ST N | 0.8 MI S OF JCT TH 36 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 45.6 | 123.4 | Fair | 97.0 | 82810 |
NBI report | I 694 NB | DNR TRAIL | 0.4 MI S OF JCT TH 36 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 43.6 | 130.9 | Good | 98.0 | 82812 |
NBI report | I 694 NB | TH 36 | AT JCT TH 36 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1967 | -- | 100.1 | 202.1 | Fair | 96.3 | 82814 |
NBI report | I 694 SB | 50TH ST N | 0.8 MI S OF JCT TH 36 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 45.6 | 123.4 | Fair | 97.0 | 82809 |
NBI report | I 694 SB | DNR TRAIL | 0.4 MI S OF JCT TH 36 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 44.3 | 133.2 | Good | 93.1 | 82811 |
NBI report | I 694 SB | TH 36 | AT JCT TH 36 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1967 | -- | 95.1 | 192.6 | Fair | 85.3 | 82813 |
NBI report | US 8 WB | I 35 | AT JCT TH 8 | Steel Girder and floorbeam system (4 spans) | -- | 1967 | -- | 104.3 | 356.0 | Fair | 74.9 | 82815 |
NBI report | CSAH 5 | MZ LTD; BROWNS CREEK | 0.2 MI SE OF JCT TH96 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 1984 | 79.4 | 198.2 | Good | 78.6 | 82501 |
NBI report | I 694 NB | UP RR | 3.0 MI N OF JCT TH 94 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 2010 | 57.1 | 144.7 | Fair | 96.6 | 82806 |
NBI report | I 694 NB | TH 5 | AT THE JCT TH 5 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | 2010 | 67.6 | 219.2 | Good | 94.6 | 82808 |
NBI report | I 694 SB | UP RR | 3.0 MI N OF JCT TH 94 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 2010 | 57.1 | 144.7 | Fair | 96.6 | 82805 |
NBI report | I 694 SB | TH 5 | AT THE JCT TH 5 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1967 | 2010 | 67.6 | 219.2 | Fair | 94.6 | 82807 |
NBI report | US 8 | 2nd St NW | 0.1 MI W OF JCT TH 61 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 63.7 | 240.8 | Fair | 89.8 | 82001 |
NBI report | US 8 | TH 61 | 1.0 MI E OF JCT TH 35 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 82.0 | 291.4 | Fair | 77.6 | 82002 |
NBI report | I 94 WB | ST CROIX RIVER STR; RR | AT WISCONSIN STATE LINE | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1971 | -- | 390.1 | 2381.3 | Fair | 82.6 | 9400 |
NBI report | TH 95 | OBRIEN TR N | 2.5 MI S OF JCT TH 97 | Prestressed Stringer/Multi-beam or girder | -- | 1975 | -- | 85.0 | 88.9 | Fair | 95.7 | 82018 |
NBI report | CR 51 | WS LIMITED | 1.0 MI NW OF JCT TH 95 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 50.9 | 156.8 | Poor | 85.7 | 82502 |
NBI report | TNSP 64(MAY AVE) | WC LIMITED | 0.2 MI N OF JCT CR 61 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 44.6 | 136.5 | Good | 91.1 | 82504 |
NBI report | US 61 | BNSF RR | 0.6 MI S OF JCT TH 10 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 106.0 | 235.6 | Fair | 77.8 | 82022 |
NBI report | MUN 53 | VALLEY CREEK | 0.9 MI E OF JCT CR 71 | Concrete Slab (3 spans) | -- | 1979 | -- | 14.1 | 42.0 | Good | 94.1 | 82505 |
NBI report | CSAH 21 | STREAM | 3.4 MI S OF JCT CSAH 20 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1980 | -- | 38.1 | 78.7 | Fair | 99.5 | 82509 |
NBI report | State Park Road | TROUT BROOK (TRIBUTARY) | Entr to Afton State Park | Wood Slab | -- | 1980 | -- | 31.5 | 82.4 | Fair | 79.3 | 82519 |
NBI report | TNSP 174(80TH ST) | STREAM | 0.7 MI W OF JCT CSAH 21 | Concrete Culvert (2 spans) | -- | 1980 | -- | 12.1 | 29.5 | Good | 98.0 | 91937 |
NBI report | TNSP 174(80TH ST) | STREAM | 0.6 MI W OF JCT CSAH 21 | Concrete Culvert (2 spans) | -- | 1980 | -- | 14.1 | 34.5 | Good | 98.0 | 91938 |
NBI report | TNSP 208(NEAL AVE) | STREAM | 0.7 MI S OF JCT CSAH 20 | Concrete Culvert (2 spans) | -- | 1980 | -- | 12.8 | 32.2 | Good | 98.0 | 91936 |
NBI report | CSAH 39 80th St | US 61 | 4.2 MI SE OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1982 | -- | 82.7 | 292.3 | Good | 96.8 | 82019 |
NBI report | CSAH 39 (US61) | CP RR; FRONTAGE RD | 4.2 MI SE OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1982 | -- | 103.7 | 206.4 | Good | 91.7 | 82020 |
NBI report | I 94 EB | TH 95 | AT THE JCT TH 95 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1982 | -- | 105.0 | 214.9 | Fair | 82.9 | 82850 |
NBI report | I 94 WB | TH 95 | AT THE JCT TH 95 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1982 | -- | 110.6 | 221.5 | Fair | 81.9 | 82849 |
NBI report | US 61 NB | Jamaica Avenue | 6.2 MI SE OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1982 | -- | 103.0 | 208.3 | Fair | 98.0 | 82004 |
NBI report | US 61 SB | Jamaica Avenue | 6.2 MI SE OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1982 | -- | 103.0 | 208.3 | Good | 98.0 | 82003 |
NBI report | CR 71 | I 94 | 5.7 MI E OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 129.9 | 264.8 | Fair | 99.9 | 82847 |
NBI report | CSAH 13 NB | I 94 | 1.2 MI E OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 128.0 | 260.5 | Fair | 97.7 | 82852 |
NBI report | CSAH 13 SB | I 94 | 1.2 MI E OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 128.0 | 260.5 | Fair | 96.7 | 82843 |
NBI report | CSAH 17 | I 94 | 3.7 MI E OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 127.0 | 329.1 | Fair | 99.8 | 82845 |
NBI report | CSAH 21 | I 94 | 8.0 MI E OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 142.4 | 290.0 | Fair | 98.7 | 82848 |
NBI report | TH 95 | I 94 | 4.8 MI E OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 130.9 | 268.1 | Fair | 81.9 | 82846 |
NBI report | CSAH 19 | I 94 | 2.7 MI E OF JCT TH 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | 2007 | 134.8 | 274.6 | Fair | 91.2 | 82844 |
NBI report | VALLEY CRK TR (53) | VALLEY CREEK | 0.3 MI W OF JCT CSAH 21 | Concrete Slab (3 spans) | -- | 1985 | -- | 18.4 | 57.1 | Good | 98.2 | 91976 |
NBI report | TH 95 | WC LIMITED RR | 1.5 MI S OF JCT TH 97 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 46.9 | 145.0 | Fair | 97.8 | 82005 |
NBI report | TH 36 | DNR Gateway Trail | 0.9 MI E OF JCT TH 694 | Concrete Frame | -- | 1987 | -- | 26.9 | 30.2 | Good | 80.0 | 82009 |
NBI report | US 10 (PRESCOTT) | St Croix River | AT WISCONSIN STATE LINE | Steel Movable - Bascule | -- | 1990 | -- | 205.4 | 683.8 | Fair | 61.9 | 82010 |
NBI report | MUN 300 | HARDWOOD CREEK | 1.4 MI S OF JCT CR 50 | Concrete Culvert (2 spans) | -- | 1992 | -- | 9.5 | 25.3 | Good | 100.0 | 97418 |
NBI report | I 94 EB | ST CROIX RIVER; ST | AT WISCONSIN STATE LINE | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1994 | -- | 390.1 | 2382.0 | Fair | 91.1 | 82800 |
NBI report | Lake Road | I 494 | 0.9 MI SW OF JCT TH 120 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 147.6 | 287.7 | Fair | 91.5 | 82511 |
NBI report | 60 ST S (MUN44) | TROUT BROOK | 1.1 MI E OF JCT CR 71 | Concrete Culvert (2 spans) | -- | 1997 | -- | 12.5 | 31.2 | Fair | 100.0 | 82J01 |
NBI report | MSAS 111(95TH ST) | DITCH | 0.8 MI W OF JAMAICA AVE | Concrete Culvert (3 spans) | -- | 1997 | -- | 8.5 | 35.8 | Good | 99.8 | 82J02 |
NBI report | TH 5 | TH 36 | AT THE JCT TH 5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1997 | -- | 107.6 | 221.5 | Good | 95.0 | 82006 |
NBI report | PEDESTRIAN | I 694 | 0.8 MI S OF JCT TH 5 | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 122.7 | -- | -- | -- | 82516 |
NBI report | TWP 172 | Stream | 0.8 MI S OF JCT CSAH 20 | Concrete Culvert (2 spans) | -- | 1999 | -- | 11.2 | 28.9 | Good | 98.0 | 82J04 |
NBI report | CSAH 21 | TROUT BROOK | 1.0 MI N OF JCT CSAH 20 | Prestressed Stringer/Multi-beam or girder | -- | 2000 | -- | 71.2 | 75.8 | Good | 98.7 | 82508 |
NBI report | BAILEY ROAD | I 494 | .2 MI NE OF JCT TH 494;61 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 136.2 | 265.1 | Good | 99.2 | 82865 |
NBI report | GLEN ROAD | HASTINGS AVENUE | 1 MI S OF JCT TH 494; 61 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 98.8 | 103.4 | Good | 98.2 | 82029 |
NBI report | GLEN ROAD | US 61 | 1 MI S OF JCT TH 494; 61 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 139.4 | 144.4 | Good | 99.5 | 82030 |
NBI report | GLEN ROAD | 7TH AVE; BNSF; CP RR | 1 MI S JCT TH 494; 61 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 174.2 | 292.0 | Good | 97.5 | 82031 |
NBI report | I 494 EB | MAXWELL AVE | 0.4 MI W OF JCT TH 61 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 130.6 | 135.8 | Good | 85.0 | 82857 |
NBI report | I 494 EB | CP; BNSF RR; TH 61 | AT THE JCT TH 494; 61 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2003 | -- | 135.5 | 655.2 | Fair | 91.9 | 82859 |
NBI report | I 494 EB | TH 61 NB ON RAMP | AT THE JCT TH 494; 61 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 126.6 | 131.6 | Good | 84.0 | 82863 |
NBI report | I 494 WB | MISSISSIPPI R; UP RR | AT DAKOTA/WASHINGTON CO | Prestressed Box beam or girders - Multiple (5 spans) | -- | 2003 | -- | 465.9 | 1891.8 | Fair | 82.0 | 82856 |
NBI report | I 494 WB | MAXWELL AVE | 0.4 MI W OF JCT TH 61 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 130.6 | 135.8 | Good | 85.0 | 82858 |
NBI report | I 494 WB | TH 61; CP; BNSF RR | AT THE JCT TH 494; 61 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2003 | -- | 135.8 | 668.3 | Fair | 91.9 | 82860 |
NBI report | I 494 WB | TH 61 NB ON RAMP | AT THE JCT TH 494; 61 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 128.0 | 132.2 | Good | 84.0 | 82864 |
NBI report | I 494 WB OFF RAMP | TH 61 SB ON RAMP | AT THE JCT TH 61; 494 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 146.7 | 272.3 | Good | 100.0 | 82036 |
NBI report | I 494 WB ON RAMP | BNSF RR; CP RR | .1 MI NW OF JCT 494;61 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 193.6 | 390.8 | Fair | 99.1 | 82034A |
NBI report | I 494 WB ON RAMP | RAMP TH 61 SB | .1 MI NW OF TH 494; 61 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 214.6 | 425.9 | Good | 99.5 | 82034B |
NBI report | I 494 WB RAMP | TH 61 SB | .17 MI NE OF TH 61; 494 | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 133.5 | 141.1 | Good | 100.0 | 82035 |
NBI report | PED | US 61, HASTING AVE, 7TH | 1.5 MI S OF JCT TH 494;61 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 215.6 | -- | -- | -- | 82028 |
NBI report | PED | US 61 7TH AVE BN; CP RR | .5 MI S OF JCT TH 494; 61 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 203.8 | -- | -- | -- | 82032 |
NBI report | RAMP 494E TO TH61S | BN; CP RAILROADS | .16 MI SW OF TH 61; 494 | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2003 | -- | 187.3 | 567.0 | Fair | 100.0 | 82037 |
NBI report | RAMP TO I 494 WB | TH 61 | .1 MI NW OF JCT TH494; 61 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 187.0 | 434.4 | Fair | 99.5 | 82034C |
NBI report | TAMARACK RD | I 494 | 0.9 MI S OF JCT 94; 494 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2003 | -- | 117.1 | 588.6 | Fair | 97.9 | 82518 |
NBI report | FABLE HILL PKWY | CLEARWATER CREEK | SW OF JCT TH 61; CSAH 8 | Steel Truss - Thru | -- | 2004 | -- | 60.0 | 64.0 | Fair | 93.0 | 82532 |
NBI report | ST PAUL PK RD | BNSF RR | 0.2 MI W OF CSAH 22 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 169.0 | 394.4 | Good | 97.5 | 82027 |
NBI report | CSAH 22 | US 61 | 2.5 MI SE OF JCT TH 494 | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 144.4 | 149.6 | Good | 99.0 | 82025 |
NBI report | CSAH 22(US61 FRONT | CP RR | 2.5 MI SE OF JT TH494;61 | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 90.6 | 101.4 | Good | 99.0 | 82026 |
NBI report | CSAH 12 | GATEWAY TRAIL | 0.2 MI W OF JCT CSAH 9 | Concrete Culvert | -- | 2006 | -- | 25.9 | 25.9 | Good | 94.2 | 82525 |
NBI report | VALLEY CREEK RD | I 494 | 1.7 MI S OF JCT TH 94 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2006 | -- | 120.4 | 246.7 | Good | 98.8 | 82016 |
NBI report | I 494 EB | MISSISSIPPI R; UP RR | AT DAKOTA/WASHINGTON CO | Prestressed Box beam or girders - Multiple (5 spans) | -- | 2008 | -- | 465.9 | 1891.8 | Good | 85.0 | 82855 |
NBI report | SAINT CROIX TR S | VALLEY BRANCH CREEK | 0.7 MI N OF AFTON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2008 | -- | 51.2 | 195.5 | Good | 99.7 | 82517 |
NBI report | EVERTON AVE | CLEARWATER CREEK | W OF JCT TH 61; CSAH 8 | Concrete Slab | -- | 2009 | -- | 44.0 | 45.6 | Good | 100.0 | 82530 |
NBI report | VAL JEAN BLVD | CLEARWATER CREEK | W OF JCT TH 61; CSAH 8 | Concrete Slab | -- | 2009 | -- | 44.0 | 45.6 | Good | 100.0 | 82531 |
NBI report | VICTOR HUGO BLVD | CLEARWATER CREEK | W OF JCT TH 61; CSAH 8 | Concrete Culvert | -- | 2009 | -- | 32.8 | 35.8 | Good | 100.0 | 82J24 |
NBI report | 220TH ST N | I 35 | 1.49 MI S OF JCT TH 8 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2010 | -- | 108.9 | 421.3 | Good | 78.6 | 82528 |
NBI report | RAVINE PARKWAY S | RAVINE | 0.26 M NE OF JCT CSAH 19 | Prestressed Stringer/Multi-beam or girder | -- | 2011 | -- | 96.1 | 97.4 | Good | 99.9 | 82533 |
NBI report | W BROADWAY AVE | I 35 | 0.5 MI S OF JCT TH 8 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2011 | -- | 127.0 | 251.7 | Good | 95.5 | 82527 |
NBI report | CSAH 21 | VALLEY CREEK | 0.1 MI S JCT VALLEY CRK R | Concrete Slab (3 spans) | -- | 2012 | -- | 22.0 | 59.7 | Good | 99.9 | 82534 |
NBI report | 60TH ST N | DNR GATEWAY TRAIL | 0.9 MI E OF JCT TH 694 | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 90.9 | 96.1 | Good | 100.0 | 82046 |
NBI report | CSAH 23 | TH 36; RAMPS | 0.2 M W OF JCT TH95 | Prestressed Slab (3 spans) | -- | 2013 | -- | 117.1 | 319.9 | Good | 98.0 | 82043 |
NBI report | TH 36 EB | HIILTON TR | 0.7 MI E OF JCT TH 694 | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 112.9 | 117.5 | Good | 96.0 | 82024 |
NBI report | TH 36 WB | HIILTON TRAIL | 0.7 MI E OF JCT TH 694 | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 112.9 | 117.5 | Good | 96.0 | 82023 |
NBI report | US 61 | CP RR | 0.8 MI S OF JCT TH 10 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2013 | -- | 80.4 | 223.8 | Good | 100.0 | 82049 |
NBI report | ONEKA PKWY | CLEARWATER CREEK | W OF JCT TH 61; CSAH 8 | Prestressed Stringer/Multi-beam or girder | -- | 2016 | -- | 53.2 | 56.4 | Good | 100.0 | 82535 |
NBI report | TH 36 EB ON RAMP | UP RR | 0.09 M E OF JCT TH95 | Prestressed Segmental box girder (4 spans) | -- | 2016 | -- | 190.3 | 632.9 | Good | 100.0 | 82048 |
NBI report | TH 36 WB EXIT RAMP | UP RR | 0.09 M E OF JCT TH95 | Prestressed Segmental box girder (5 spans) | -- | 2016 | -- | 231.6 | 961.0 | Good | 100.0 | 82047 |
NBI report | TH 36 | ST CROIX RIVER-TH95-UPRR | 0.09 M E OF JCT TH95 | Prestressed Segmental box girder (6 spans) | -- | 2017 | -- | 600.1 | 5079.3 | Good | 100.0 | 82045 |