Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | W HICKORY ST | TOWN BR | S 10 T 54 N R 10 W | Concrete Slab (2 spans) | -- | -- | -- | 12.8 | 25.9 | Poor | 18.7 | 21934 |
NBI report Bridgehunter | COUNTY RD 211 | CROOKED CR | S 22 T 56 N R 11 W | Steel Truss - Thru | -- | 1910 | -- | 49.9 | 50.9 | Poor | 23.1 | 24935 |
NBI report Bridgehunter | COUNTY RD 215 | MID FK OF SALT RVR | S 35 T 55 N R 11 W | Steel Truss - Thru | -- | 1910 | -- | 102.0 | 150.9 | Poor | 0.0 | 22467 |
NBI report Bridgehunter | COUNTY RD 255 | CROOKED CR | S 32 T 56 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 69.9 | 97.1 | Poor | 16.9 | 24848 |
NBI report Bridgehunter | COUNTY RD 275 | OTTER CR | S 21 T 55 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 60.0 | 97.1 | Poor | 17.7 | 23347 |
NBI report Bridgehunter | COUNTY RD 611 | LONG BR | S 25 T 53 N R 9 W | Steel Truss - Thru | -- | 1910 | -- | 80.1 | 119.1 | Poor | 16.7 | 13069 |
NBI report Bridgehunter | COUNTY RD 819 | LONG BRANCH CR | S 25 T 53 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 47.9 | 81.0 | Fair | 31.1 | 14816 |
NBI report Bridgehunter | COUNTY RD 857 | ELK FK SALT RVR | S 29 T 54 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 111.9 | 158.1 | Poor | 19.7 | 19066 |
NBI report Bridgehunter | COUNTY RD 857 | BEE CR | S 29 T 54 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 75.1 | 98.1 | Poor | 19.9 | 19073 |
NBI report Bridgehunter | COUNTY RD 859 | LONG BRANCH CR | S 28 T 53 N R 10 W | Steel Truss - Thru | -- | 1910 | -- | 61.0 | 90.9 | Poor | 22.9 | 14617 |
NBI report Bridgehunter | COUNTY RD 976 | BRIAR CR | S 22 T 54 N R 11 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1910 | -- | 28.9 | 69.9 | Poor | 32.9 | 19841 |
NBI report | COUNTY RD 1101 | FLAT CR | S 6 T 54 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1910 | 2002 | 36.1 | 37.4 | Fair | 87.0 | 29404 |
NBI report Bridgehunter | COUNTY RD 624 | LONG BR | S 18 T 53 N R 8 W | Steel Truss - Thru | -- | 1914 | -- | 111.9 | 170.0 | Poor | 23.9 | 12722 |
NBI report | COUNTY RD 390 | INDIAN CR | S 19 T 56 N R 8 W | Steel Stringer/Multi-beam or girder | -- | 1916 | -- | 27.9 | 28.9 | Fair | 43.2 | 24603 |
NBI report Bridgehunter | COUNTY RD 139 | OTTER CR | S 31 T 56 N R 11 W | Steel Truss - Thru | -- | 1920 | -- | 60.0 | 61.0 | Fair | 44.2 | 24970 |
NBI report Bridgehunter | COUNTY RD 141 | MID FK OF SALT RVR | S 29 T 55 N R 11 W | Steel Truss - Thru | -- | 1920 | -- | 90.9 | 141.1 | Fair | 40.2 | 22412 |
NBI report Bridgehunter | COUNTY RD 759 | LONG BR | S 28 T 53 N R 9 W | Steel Truss - Thru | -- | 1920 | -- | 75.1 | 113.9 | Fair | 43.2 | 13299 |
NBI report | COUNTY RD 800 | BRANCH | S 29 T 53 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1920 | 1983 | 32.2 | 32.2 | Fair | 47.7 | 14716 |
NBI report Bridgehunter | COUNTY RD 591 | LIT INDIAN CR | S 6 T 55 N R 7 W | Steel Stringer/Multi-beam or girder | -- | 1920 | 2005 | 46.9 | 50.9 | Fair | 81.0 | 24442 |
NBI report Bridgehunter | COUNTY RD 591 | LIT INDIAN CR | S 31 T 56 N R 7 W | Concrete Channel beam | -- | 1920 | 2012 | 50.5 | 52.5 | Fair | 87.0 | 24537 |
NBI report Bridgehunter | COUNTY RD 233 | CROOKED CR | S 30 T 56 N R 10 W | Steel Truss - Thru | -- | 1923 | -- | 80.1 | 81.0 | Fair | 61.2 | 24842 |
NBI report Bridgehunter | COUNTY RD 1159 | MUD CR | S 21 T 55 N R 12 W | Steel Truss - Thru | -- | 1925 | -- | 101.1 | 102.0 | Fair | 31.2 | 21368 |
NBI report | COUNTY RD 986 | BRIAR CR | S 15 T 54 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 33.1 | 35.1 | Poor | 27.3 | 19780 |
NBI report | MO 15 S | MATTS CR | S 23 T 53 N R 10 W | Concrete Culvert (2 spans) | -- | 1925 | -- | 12.1 | 24.9 | Fair | 96.3 | 4875 |
NBI report | MO 15 S | CR | S 11 T 54 N R 10 W | Concrete Culvert (2 spans) | -- | 1925 | -- | 12.1 | 45.3 | Fair | 86.0 | 4894 |
NBI report Bridgehunter | COUNTY RD 239 | OTTER CR | S 19 T 55 N R 10 W | Steel Truss - Thru | -- | 1930 | -- | 49.9 | 50.9 | Fair | 41.7 | 23372 |
NBI report | COUNTY RD 360 | CLEAR CR | S 1 T 55 N R 10 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1930 | -- | 35.1 | 69.9 | Poor | 20.8 | 23150 |
NBI report Bridgehunter | COUNTY RD 756 | TURKEY CR | S 2 T 53 N R 10 W | Steel Truss - Thru | Closed | 1930 | -- | 36.1 | 37.1 | Poor | 18.0 | 13701 |
NBI report | COUNTY RD 840 | BRANCH | S 5 T 53 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 35.1 | 36.1 | Fair | 56.8 | 14005 |
NBI report | COUNTY RD 857 | BRANCH | S 29 T 54 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 24.9 | 25.9 | Poor | 21.8 | 19065 |
NBI report | MO 154 E | IVY BR | S 16 T 54 N R 8 W | Concrete Culvert (2 spans) | -- | 1930 | -- | 12.1 | 31.8 | Fair | 96.9 | 5278 |
NBI report | MO 154 E | IVY BR | S 15 T 54 N R 8 W | Concrete Culvert (2 spans) | -- | 1930 | -- | 7.9 | 24.0 | Fair | 95.5 | 5279 |
NBI report | MO 154 E | IVY BR | S 15 T 54 N R 8 W | Concrete Culvert (2 spans) | -- | 1930 | -- | 9.8 | 29.5 | Fair | 97.1 | 5280 |
NBI report | MO 154 E | CAMP CR | S 24 T 54 N R 8 W | Concrete Culvert (3 spans) | -- | 1930 | -- | 9.8 | 32.2 | Fair | 98.6 | 5281 |
NBI report | US 24 E | INDIAN CR | S 3 T 55 N R 8 W | Concrete Culvert (2 spans) | -- | 1931 | -- | 12.1 | 26.6 | Fair | 95.9 | 5514 |
NBI report | US 24 E | LIT INDIAN CR | S 36 T 56 N R 8 W | Concrete Culvert (2 spans) | -- | 1931 | -- | 12.1 | 35.4 | Fair | 81.8 | 5527 |
NBI report | MO 151 S | SMALL CR | S 11 T 53 N R 12 W | Concrete Culvert (2 spans) | -- | 1933 | -- | 9.8 | 29.2 | Fair | 75.9 | 8897 |
NBI report | RT A S | LIT OTTER CR | S 15 T 55 N R 11 W | Concrete Culvert (2 spans) | -- | 1933 | -- | 9.8 | 24.9 | Fair | 81.3 | 9104 |
NBI report | RT M E | MILLIGAN CR | S 9 T 53 N R 12 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1933 | -- | 49.2 | 130.9 | Poor | 29.8 | 9105 |
NBI report | COUNTY RD 1175 | BRANCH | S 3 T 55 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 32.2 | 32.2 | Fair | 39.3 | 21548 |
NBI report | COUNTY RD 130 | CREEK | S 33 T 55 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 24.0 | 24.0 | Fair | 33.2 | 22638 |
NBI report | COUNTY RD 370 | BRANCH | S 27 T 56 N R 8 W | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 30.8 | 32.2 | Poor | 31.7 | 24563 |
NBI report | COUNTY RD 211 | BRANCH | S 26 T 56 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1937 | -- | 30.8 | 32.2 | Poor | 36.0 | 24939 |
NBI report | RT M E | BEE BR | S 18 T 53 N R 11 W | Concrete Culvert (2 spans) | -- | 1938 | -- | 12.1 | 24.6 | Fair | 89.9 | 9307 |
NBI report | COUNTY RD 119 | BRANCH | S 30 T 56 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 22.0 | 23.0 | Fair | 43.2 | 24978 |
NBI report | COUNTY RD 326 | BRANCH | S 16 T 55 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 30.8 | 32.2 | Fair | 24.0 | 23826 |
NBI report | RT E S | VAUGHN HOLLOW BR | S 34 T 54 N R 8 W | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 24.9 | Good | 95.7 | 7437 |
NBI report | RT E S | BEAR BR | S 10 T 53 N R 8 W | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 21.3 | Fair | 81.0 | 7438 |
NBI report | RT E S | IVY BR | S 21 T 54 N R 8 W | Concrete Slab | -- | 1950 | -- | 25.6 | 34.1 | Good | 48.4 | 9921 |
NBI report | RT J E | MID FK SALT RVR | S 8 T 55 N R 12 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1950 | -- | 80.1 | 184.1 | Poor | 47.9 | 9742 |
NBI report | COUNTY RD 323 | BRUSH CR | S 19 T 56 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1952 | -- | 35.1 | 36.1 | Fair | 63.4 | 24738 |
NBI report Bridgehunter | CITY ST | MID FK OF SALT RVR | S 11 T 54 N R 10 W | Steel Truss - Thru | -- | 1955 | -- | 80.1 | 109.9 | Poor | 18.8 | 21931 |
NBI report | RT AA E | BEE CR | S 5 T 53 N R 10 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1956 | -- | 60.0 | 163.1 | Poor | 41.3 | 7918 |
NBI report | COUNTY RD 141 | BR MID FK SALT RVR | S 29 T 55 N R 11 W | Concrete Tee beam | -- | 1958 | -- | 30.8 | 35.1 | Fair | 49.8 | 22409 |
NBI report | RT Y S | BR REESE FK | S 28 T 53 N R 12 W | Concrete Culvert (2 spans) | -- | 1958 | -- | 12.1 | 24.6 | Fair | 82.5 | 7034 |
NBI report | RT YY E | COON CR | S 30 T 54 N R 12 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 2005 | 46.9 | 143.4 | Good | 86.8 | 7248 |
NBI report | RT YY E | MILLIGAN CR | S 33 T 54 N R 12 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1960 | 2005 | 48.9 | 174.2 | Good | 83.8 | 7249 |
NBI report | RT P E | BR OTTER CR | S 17 T 55 N R 9 W | Concrete Culvert (2 spans) | -- | 1961 | -- | 12.1 | 28.5 | Fair | 89.9 | 8080 |
NBI report | RT P E | BR OTTER CR | S 14 T 55 N R 10 W | Concrete Culvert (2 spans) | -- | 1961 | -- | 9.8 | 20.7 | Fair | 91.4 | 8081 |
NBI report | RT PP S | BR BLACK CR | S 17 T 56 N R 9 W | Concrete Culvert (3 spans) | -- | 1961 | -- | 9.8 | 31.2 | Fair | 99.9 | 6901 |
NBI report | RT Z S | BRUSH CR | S 2 T 53 N R 9 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 34.1 | 101.1 | Poor | 62.8 | 8082 |
NBI report | RT Z S | BRUSH CR | S 10 T 53 N R 9 W | Concrete Culvert (2 spans) | -- | 1961 | -- | 12.1 | 24.6 | Fair | 97.3 | 8083 |
NBI report | RT EE S | INDIAN CR | S 28 T 56 N R 8 W | Concrete Culvert (3 spans) | -- | 1962 | -- | 11.2 | 48.6 | Fair | 89.1 | 6900 |
NBI report | RT MM S | CROOKED CR BR | S 36 T 56 N R 11 W | Concrete Culvert (2 spans) | -- | 1962 | -- | 14.1 | 40.7 | Fair | 92.7 | 8228 |
NBI report | RT OO S | BR MID FK SALT RVR | S 17 T 55 N R 12 W | Concrete Culvert (2 spans) | -- | 1962 | -- | 15.1 | 35.4 | Good | 94.3 | 8227 |
NBI report Bridgehunter | RT A S | MID FK SALT RVR | S 27 T 55 N R 11 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2011 | 100.1 | 353.0 | Fair | 56.9 | 8378 |
NBI report Bridgehunter | RT D E | LONG BR CR | S 18 T 53 N R 8 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2011 | 90.9 | 233.9 | Good | 67.2 | 9341 |
NBI report | RT AA E | ELK FK SALT RVR | S 29 T 54 N R 11 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 98.1 | 253.9 | Fair | 67.9 | 8439 |
NBI report | RT D E | S FK SALT RVR | S 16 T 53 N R 8 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | -- | 115.2 | 288.1 | Poor | 43.0 | 8399 |
NBI report | US 24 E | MID FK SALT RVR | S 10 T 54 N R 10 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | -- | 120.1 | 303.2 | Poor | 78.9 | 1390 |
NBI report | RT C S | BEE CR | S 10 T 53 N R 11 W | Concrete Culvert (2 spans) | -- | 1968 | -- | 9.8 | 20.7 | Fair | 99.6 | 1987 |
NBI report Bridgehunter | RT C S | ELK FK SALT RVR | S 25 T 54 N R 11 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2009 | 96.1 | 291.0 | Fair | 82.6 | 1986 |
NBI report | RT Z S | LONG BR | S 26 T 53 N R 9 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 82.0 | 211.0 | Good | 81.7 | 2125 |
NBI report | MO 151 S | ELK FK SALT RVR | S 23 T 54 N R 12 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1973 | -- | 60.7 | 181.1 | Good | 84.5 | 2752 |
NBI report | COUNTY RD 943 | BRANCH | S 5 T 53 N R 11 W | Concrete Slab | -- | 1973 | 1997 | 27.9 | 28.9 | Fair | 95.0 | 15023 |
NBI report | COUNTY RD 1039 | MILLIGAN CR | S 5 T 53 N R 12 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1976 | -- | 35.1 | 75.1 | Fair | 24.8 | 16519 |
NBI report | MO 154 E | ELK FK SALT RVR | S 22 T 54 N R 9 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1976 | -- | 100.1 | 628.0 | Fair | 93.6 | 3104 |
NBI report | MO 154 E | S FK SALT RVR | S 17 T 54 N R 8 W | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1976 | -- | 120.1 | 925.9 | Fair | 91.8 | 3105 |
NBI report | MO 154 E | JORDAN BR | S 14 T 54 N R 9 W | Concrete Culvert (3 spans) | -- | 1976 | -- | 11.2 | 36.1 | Fair | 97.5 | 3107 |
NBI report | RT U E | MID FK SALT RVR | S 3 T 54 N R 9 W | Concrete Culvert (3 spans) | -- | 1976 | -- | 12.1 | 49.5 | Fair | 100.0 | 3109 |
NBI report | RT Z S | JORDAN BR | S 23 T 54 N R 9 W | Concrete Culvert (2 spans) | -- | 1976 | -- | 11.2 | 40.0 | Fair | 99.8 | 3106 |
NBI report Bridgehunter | MO 107 S | N FK SALT RVR | S 33 T 55 N R 8 W | Steel Stringer/Multi-beam or girder (13 spans) | -- | 1977 | -- | 123.0 | 2012.2 | Fair | 77.0 | 3154 |
NBI report Bridgehunter | MO 107 S | S FK SALT RVR | S 9 T 54 N R 8 W | Steel Stringer/Multi-beam or girder (11 spans) | -- | 1977 | -- | 123.0 | 1652.0 | Fair | 92.7 | 3155 |
NBI report | RT FF E | N FK SALT RVR | S 33 T 56 N R 9 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 109.9 | 539.1 | Good | 86.8 | 3110 |
NBI report | US 24 E | OTTER CR | S 22 T 55 N R 9 W | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 1977 | -- | 75.1 | 625.0 | Fair | 87.7 | 3168 |
NBI report | US 24 E | N FK SALT RVR | S 14 T 55 N R 9 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 123.0 | 764.1 | Fair | 97.4 | 3169 |
NBI report | COUNTY RD 436 | BRANCH | S 5 T 54 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1978 | 1987 | 26.9 | 28.9 | Fair | 51.5 | 18602 |
NBI report | COUNTY RD 1023 | MILLIGAN CR | S 17 T 53 N R 12 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1979 | -- | 41.0 | 84.0 | Fair | 43.2 | 16310 |
NBI report | COUNTY RD 1119 | MUD CR | S 30 T 55 N R 12 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1979 | -- | 39.0 | 62.0 | Fair | 50.3 | 21204 |
NBI report | COUNTY RD 621 | BRUSH CR | S 31 T 54 N R 8 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1981 | -- | 75.1 | 217.9 | Good | 79.5 | 17536 |
NBI report | US 24 E | BUCK CR | S 12 T 55 N R 9 W | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 24.6 | Fair | 85.4 | 3327 |
NBI report | US 24 E | NS RR | S 7 T 55 N R 8 W | Prestressed Tee beam (5 spans) | -- | 1984 | -- | 40.0 | 181.1 | Good | 96.8 | 3328 |
NBI report | US 24 E | INDIAN CR | S 3 T 55 N R 8 W | Prestressed Tee beam (3 spans) | -- | 1984 | -- | 50.2 | 149.9 | Fair | 89.3 | 3329 |
NBI report | MO 15 S | CROOKED CR | S 32 T 56 N R 10 W | Prestressed Tee beam (4 spans) | -- | 1985 | -- | 49.5 | 196.9 | Good | 88.2 | 3574 |
NBI report | MO 15 S | MID FK SALT RVR | S 2 T 54 N R 10 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1985 | -- | 120.1 | 345.2 | Fair | 86.2 | 3593 |
NBI report | COUNTY RD 1137 | FLAT CR | S 3 T 54 N R 12 W | Steel Culvert | -- | 1986 | -- | 35.1 | 36.1 | Fair | 89.8 | 21078 |
NBI report | COUNTY RD 239 | BRANCH | S 17 T 56 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 22.0 | 24.0 | Good | 58.5 | 24820 |
NBI report | COUNTY RD 317 | BRUSH CR | S 24 T 56 N R 10 W | Steel Girder and floorbeam system | -- | 1987 | -- | 47.9 | 51.8 | Fair | 73.9 | 24804 |
NBI report | COUNTY RD 343 | BRANCH | S 27 T 56 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 36.1 | 38.1 | Good | 61.3 | 24747 |
NBI report | COUNTY RD 1061 | REESE FK BR | S 27 T 53 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 73.2 | 77.1 | Good | 39.5 | 16013 |
NBI report | COUNTY RD 182 | BRANCH | S 32 T 56 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 30.8 | 34.1 | Good | 43.8 | 24881 |
NBI report | COUNTY RD 217 | OTTER CR | S 14 T 55 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 67.9 | 70.9 | Fair | 47.7 | 22259 |
NBI report | COUNTY RD 311 | CROOKED CR | S 2 T 55 N R 10 W | Steel Girder and floorbeam system | -- | 1988 | -- | 80.1 | 100.1 | Fair | 65.0 | 23525 |
NBI report | COUNTY RD 819 | BEE CR | S 7 T 53 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 36.1 | 38.1 | Fair | 48.6 | 13942 |
NBI report | MO 15 S | OTTER CR | S 23 T 55 N R 10 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 86.0 | 256.9 | Good | 98.4 | 3758 |
NBI report | MO 15 S | ELK FK SALT RVR | S 23 T 54 N R 10 W | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1988 | -- | 90.9 | 464.9 | Good | 96.0 | 3840 |
NBI report | COUNTY RD 311 | CLEAR CR | S 27 T 56 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 59.1 | 63.0 | Good | 90.5 | 24812 |
NBI report | COUNTY RD 946 | REESE FK BR | S 6 T 53 N R 11 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1989 | -- | 76.1 | 133.9 | Fair | 75.7 | 15760 |
NBI report | COUNTY RD 1043 | ELK FK SALT RVR | S 28 T 54 N R 12 W | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1990 | -- | 60.0 | 97.1 | Good | 97.0 | 20761 |
NBI report | COUNTY RD 1033 | ELK FK SALT RVR | S 20 T 54 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 56.1 | 59.1 | Good | 91.9 | 20965 |
NBI report | COUNTY RD 611 | S BRUSH CR | S 12 T 53 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 53.2 | 55.1 | Fair | 95.0 | 13549 |
NBI report | COUNTY RD 645 | S FK SALT RVR | S 20 T 53 N R 8 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 89.9 | 250.0 | Good | 100.0 | 12924 |
NBI report | COUNTY RD 739 | LONG BR | S 30 T 53 N R 9 W | Prestressed Tee beam (3 spans) | -- | 1992 | -- | 49.9 | 120.1 | Fair | 100.0 | 13363 |
NBI report | COUNTY RD 959 | LONG BRANCH CR | S 20 T 53 N R 11 W | Prestressed Tee beam (3 spans) | -- | 1992 | -- | 44.9 | 134.8 | Good | 99.0 | 15410 |
NBI report | COUNTY RD 117 | MID FK OF SALT RVR | S 30 T 55 N R 11 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 61.4 | 183.1 | Fair | 100.0 | 22380 |
NBI report | RT A S | CROOKED CR | S 15 T 56 N R 11 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 45.6 | 136.2 | Good | 99.0 | 4187 |
NBI report | COUNTY RD 1073 | ELK FK SALT RVR | S 27 T 54 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1994 | -- | 76.1 | 77.1 | Good | 87.7 | 20803 |
NBI report | COUNTY RD 386 | CLEAR CR | S 22 T 56 N R 10 W | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 65.9 | 68.9 | Good | 100.0 | 24772 |
NBI report | COUNTY RD 184 | BRANCH | S 31 T 56 N R 12 W | Concrete Slab | -- | 1995 | -- | 29.9 | 29.9 | Fair | 100.0 | 24886 |
NBI report | COUNTY RD 325 | CROOKED CR | S 5 T 55 N R 9 W | Prestressed Tee beam (3 spans) | -- | 1995 | -- | 49.9 | 154.9 | Good | 99.0 | 24005 |
NBI report | COUNTY RD 670 | BURBRIDGE CR | S 25 T 54 N R 8 W | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 28.9 | 42.0 | Fair | 58.5 | 17104 |
NBI report | COUNTY RD 1145 | MUD CR | S 21 T 55 N R 12 W | Prestressed Tee beam (3 spans) | -- | 1996 | -- | 37.1 | 110.9 | Fair | 100.0 | 21996 |
NBI report | COUNTY RD 813 | UPPER BEE CR | S 11 T 53 N R 11 W | Steel Culvert (2 spans) | -- | 1997 | -- | 8.9 | 21.0 | Fair | 97.0 | 14849 |
NBI report | COUNTY RD 1009 | BRANCH | S 6 T 53 N R 12 W | Concrete Slab | -- | 1998 | -- | 28.9 | 29.9 | Fair | 97.0 | 16481 |
NBI report | COUNTY RD 1130 | FLAT CR | S 3 T 54 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 59.1 | 60.0 | Good | 94.7 | 20678 |
NBI report | COUNTY RD 120 | BRANCH | S 36 T 55 N R 12 W | Steel Culvert (2 spans) | -- | 1999 | -- | 7.9 | 21.0 | Fair | 100.0 | 25020 |
NBI report | COUNTY RD 146 | BRANCH | S 20 T 55 N R 11 W | Steel Culvert (2 spans) | -- | 1999 | -- | 7.9 | 20.0 | Fair | 100.0 | 22781 |
NBI report | COUNTY RD 343 | BRANCH | S 34 T 56 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 59.1 | 60.0 | Fair | 96.0 | 24748 |
NBI report | COUNTY RD 394 | BRUSH CR | S 14 T 56 N R 10 W | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 63.0 | 65.0 | Good | 100.0 | 24761 |
NBI report | COUNTY RD 657 | BR OF S FK SALT RV | S 21 T 53 N R 8 W | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 83.0 | 85.0 | Good | 99.0 | 12896 |
NBI report | COUNTY RD 743 | ELK FK SALT RVR | S 29 T 54 N R 9 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 62.0 | 169.0 | Good | 99.0 | 18163 |
NBI report | COUNTY RD 800 | BRANCH | S 25 T 53 N R 11 W | Steel Culvert (2 spans) | -- | 1999 | -- | 8.9 | 22.0 | Fair | 97.0 | 15343 |
NBI report | COUNTY RD 819 | ELK FK SALT RVR | S 30 T 54 N R 10 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 60.0 | 180.1 | Good | 99.0 | 19689 |
NBI report | COUNTY RD 835 | BEE CR | S 5 T 53 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 39.0 | 40.0 | Good | 92.9 | 13868 |
NBI report | MO 151 S | FLAT CR | S 1 T 54 N R 12 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 75.5 | 213.9 | Good | 99.4 | 11881 |
NBI report | COUNTY RD 508 | BRANCH | S 25 T 56 N R 8 W | Concrete Culvert (2 spans) | -- | 2001 | -- | 16.1 | 33.1 | Good | 97.0 | 24544 |
NBI report | CALDWELL ST | BR OF SALT RVR | S 11 T 54 N R 10 W | Concrete Slab | -- | 2002 | -- | 28.9 | 32.2 | Good | 97.5 | 29370 |
NBI report | COUNTY RD 117 | MILLIGAN CR | S 19 T 53 N R 12 W | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 87.9 | 89.9 | Good | 99.0 | 29265 |
NBI report | COUNTY RD 699 | PURDEY CR | S 7 T 53 N R 7 W | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 81.4 | 84.0 | Good | 100.0 | 29754 |
NBI report | RT CC E | BRUSH CR | S 30 T 56 N R 9 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 49.9 | 141.4 | Good | 98.8 | 29465 |
NBI report | COUNTY RD 119 | UPPER OTTER CR | S 31 T 56 N R 11 W | Prestressed Stringer/Multi-beam or girder | -- | 2004 | -- | 76.1 | 76.4 | Good | 100.0 | 29755 |
NBI report | COUNTY RD 323 | BRANCH | S 18 T 56 N R 9 W | Steel Culvert (2 spans) | -- | 2004 | -- | 8.5 | 21.0 | Good | 97.0 | 30425 |
NBI report | COUNTY RD 606 | BRANCH | S 26 T 53 N R 8 W | Steel Culvert (2 spans) | -- | 2004 | -- | 8.9 | 22.0 | Good | 97.0 | 30545 |
NBI report | MO 151 S | MIDDLE FK SALT RVR | S 26 T 55 N R 12 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 81.0 | 245.7 | Good | 99.7 | 30194 |
NBI report | BASKETT ST | PAYNE BR | S 10 T 54 N R 10 W | Metal Culvert | -- | 2005 | -- | 25.6 | 28.5 | Good | 80.5 | 31379 |
NBI report | COUNTY RD 260 | OTTER CR | S 11 T 55 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 2005 | -- | 93.5 | 95.1 | Good | 100.0 | 30749 |
NBI report | COUNTY RD 875 | BR ELK FK SALT RVR | S 21 T 54 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 2005 | -- | 82.4 | 85.0 | Good | 100.0 | 30712 |
NBI report | RT KK E | TURKEY CR | S 26 T 54 N R 10 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2005 | -- | 60.0 | 147.3 | Good | 93.0 | 30826 |
NBI report | COUNTY RD 1039 | MILLIGAN CR | S 16 T 53 N R 12 W | Prestressed Stringer/Multi-beam or girder | -- | 2006 | -- | 107.0 | 112.2 | Fair | 99.0 | 31340 |
NBI report | COUNTY RD 130 | BRANCH | S 29 T 55 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 2006 | -- | 29.9 | 30.8 | Fair | 51.5 | 31384 |
NBI report | COUNTY RD 781 | BRUSH CR | S 3 T 53 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 2006 | -- | 92.5 | 95.1 | Good | 100.0 | 31356 |
NBI report | COUNTY RD 840 | BEE CR | S 6 T 53 N R 10 W | Steel Stringer/Multi-beam or girder | -- | 2006 | -- | 48.6 | 50.5 | Good | 98.0 | 31396 |
NBI report | COUNTY RD 591 | LIT INDIAN CR | S 31 T 56 N R 7 W | Concrete Channel beam | -- | 2007 | -- | 44.9 | 45.9 | Good | 97.0 | 32160 |
NBI report | COUNTY RD 800 | TEN MILE CR | S 25 T 53 N R 11 W | Steel Stringer/Multi-beam or girder | -- | 2007 | -- | 91.9 | 95.1 | Good | 100.0 | 31827 |
NBI report | COUNTY RD 831 | LONG BRANCH CR | S 27 T 53 N R 10 W | Prestressed Stringer/Multi-beam or girder | -- | 2007 | -- | 92.9 | 94.8 | Fair | 99.0 | 31693 |
NBI report | COUNTY RD 836 | BRANCH | S 6 T 53 N R 10 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2007 | -- | 16.4 | 34.5 | Fair | 43.3 | 31951 |
NBI report | RT A S | OTTER CR | S 3 T 55 N R 11 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2007 | -- | 60.0 | 181.1 | Good | 94.2 | 31824 |
NBI report | RT C S | LONG BR CR | S 27 T 53 N R 11 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2007 | -- | 50.9 | 133.9 | Good | 94.3 | 31810 |
NBI report | COUNTY RD 1190 | BRANCH | S 5 T 55 N R 12 W | Steel Culvert (2 spans) | -- | 2008 | -- | 8.5 | 22.3 | Good | 97.0 | 32505 |
NBI report | COUNTY RD 329 | OTTER CR | S 20 T 55 N R 9 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 71.5 | 155.5 | Good | 100.0 | 32541 |
NBI report | COUNTY RD 875 | ELK FORK SALT RVR | S 28 T 54 N R 10 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 80.1 | 164.4 | Good | 100.0 | 32799 |
NBI report | COUNTY RD 436 | BR MID FK SALT RVR | S 1 T 54 N R 10 W | Concrete Tee beam | -- | 2010 | -- | 27.9 | 28.9 | Good | 98.0 | 32673 |
NBI report | COUNTY RD 117 | FLAT CR | S 25 T 55 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 2011 | -- | 97.1 | 100.1 | Good | 98.0 | 33074 |
NBI report | COUNTY RD 250 | BRANCH | S 16 T 55 N R 10 W | Steel Culvert (2 spans) | -- | 2011 | -- | 8.5 | 21.3 | Good | 97.0 | 33636 |
NBI report Bridgehunter | MO 151 S | REESE FK OF SALT R | S 14 T 53 N R 12 W | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2011 | -- | 75.1 | 197.2 | Good | 87.4 | 33625 |
NBI report | COUNTY RD 286 | DUNCAN CR | S 29 T 56 N R 10 W | Concrete Channel beam | -- | 2012 | -- | 25.3 | 46.6 | Good | 100.0 | 33827 |
NBI report | COUNTY RD 739 | MATT'S BR | S 30 T 53 N R 9 W | Prestressed Stringer/Multi-beam or girder | -- | 2012 | -- | 60.0 | 62.7 | Good | 100.0 | 33785 |
NBI report | COUNTY RD 956 | HORNE BR | S 34 T 54 N R 11 W | Prestressed Box beam or girders - Multiple | -- | 2012 | -- | 49.2 | 51.8 | Good | 100.0 | 33828 |
NBI report | RT CC E | CLEAR CR | S 26 T 56 N R 10 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2012 | -- | 60.0 | 155.8 | Good | 92.2 | 33936 |
NBI report | COUNTY RD 611 | N BRUSH CR | S 36 T 54 N R 9 W | Concrete Channel beam | -- | 2014 | -- | 47.9 | 49.9 | Good | 98.0 | 34523 |
NBI report | COUNTY RD 670 | BURBRIDGE CR | S 30 T 54 N R 7 W | Steel Stringer/Multi-beam or girder | -- | 2014 | -- | 55.1 | 60.0 | Good | 100.0 | 34740 |
NBI report | COUNTY RD 857 | BRANCH | S 17 T 54 N R 10 W | Concrete Culvert (2 spans) | -- | 2014 | -- | 15.1 | 30.2 | Fair | 88.4 | 34524 |
NBI report | COUNTY RD 983 | BRANCH | S 10 T 54 N R 11 W | Concrete Slab | -- | 2014 | -- | 26.9 | 29.9 | Good | 98.0 | 34525 |
NBI report | COUNTY RD 109 | UPPER OTTER CR | S 1 T 55 N R 12 W | Steel Stringer/Multi-beam or girder | -- | 2016 | -- | 57.4 | 60.0 | Good | 100.0 | 35166 |
NBI report | COUNTY RD 923 | BRANCH | S 36 T 54 N R 12 W | Concrete Channel beam | -- | 2016 | -- | 27.9 | 29.9 | Good | 98.0 | 35167 |
NBI report | COUNTY RD 369 | TRIB OF INDIAN CR | S 32 T 56 N R 8 W | Steel Girder and floorbeam system | -- | 2017 | -- | 44.9 | 46.9 | Good | 100.0 | 35631 |