Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | BUCKLEY RD | SMALL CR | S 6 T 46 N R 22 W | Steel Stringer/Multi-beam or girder | -- | -- | -- | 28.9 | 29.9 | Fair | 55.1 | 13052 |
NBI report | MEYERS RD | FLAT CR | S 31 T 44 N R 22 W | Steel Stringer/Multi-beam or girder | -- | -- | -- | 24.0 | 24.9 | Fair | 25.9 | 23909 |
NBI report | SCHENK RD | MUDDY CR | S 17 T 45 N R 23 W | Steel Girder and floorbeam system | -- | -- | 1982 | 37.1 | 38.1 | Fair | 41.8 | 23241 |
NBI report | HIGGINS RD | TRIB TO BEAR BR | S 3 T 47 N R 23 W | Prestressed Tee beam (3 spans) | -- | 1908 | 1986 | 44.9 | 137.1 | Good | 98.0 | 14043 |
NBI report | ARATOR RD | SMALL CR | S 2 T 45 N R 20 W | Steel Stringer/Multi-beam or girder | -- | 1910 | -- | 27.9 | 28.9 | Fair | 48.8 | 18737 |
NBI report Bridgehunter | BOONVILLE RD | SHAVER CR | S 35 T 46 N R 20 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1910 | 1958 | 48.2 | 75.1 | Fair | 49.4 | 18661 |
NBI report Bridgehunter | MAIN ST | MUDDY CR | S 3 T 45 N R 23 W | Steel Truss - Thru | -- | 1915 | -- | 44.9 | 88.9 | Poor | 23.9 | 23537 |
NBI report | MCCURDY RD | MUDDY CR | S 8 T 46 N R 21 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1915 | 1987 | 87.9 | 265.1 | Good | 75.7 | 15917 |
NBI report Bridgehunter | BENNETT RD | FLAT CR | S 29 T 44 N R 22 W | Steel Truss - Thru | -- | 1915 | 2001 | 60.0 | 89.9 | Poor | 21.9 | 22096 |
NBI report | BUNKER HILL RD | TRIB OF LAKE CR | S 23 T 44 N R 20 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1920 | -- | 20.0 | 41.0 | Fair | 69.0 | 20368 |
NBI report | ELM BRANCH RD | CREEK | S 7 T 43 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 29.9 | 29.9 | Fair | 26.2 | 21189 |
NBI report | HOFFMAN RD | BR OF HENRY CR | S 12 T 43 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 28.9 | 29.9 | Fair | 26.8 | 20905 |
NBI report | LIMESTONE VALLEY | SHAVER CR | S 26 T 46 N R 20 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1920 | -- | 8.9 | 36.1 | Fair | 41.7 | 24064 |
NBI report | MCVEY RD | SMALL CR | S 18 T 45 N R 20 W | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 21.0 | 22.0 | Fair | 48.9 | 19276 |
NBI report | PLEASANT HILL RD | WALNUT CR | S 25 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1920 | -- | 25.9 | 50.9 | Fair | 28.8 | 20091 |
NBI report Bridgehunter | S GRAND AVE | FLAT CR | S 21 T 45 N R 21 W | Steel Truss - Thru (2 spans) | NR eligible | 1920 | -- | 85.0 | 170.0 | Fair | 59.8 | 19867 |
NBI report | MCVEY RD | SMALL CR | S 14 T 45 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1920 | 1986 | 25.9 | 26.9 | Fair | 68.8 | 19561 |
NBI report Bridgehunter | WASHINGTON ST | UP RR | S 5 T 45 N R 21 W | Steel Truss - Thru | -- | 1920 | 1989 | 115.2 | 319.9 | Fair | 65.8 | 23167 |
NBI report | GEORGETOWN RD | PEARL RVR | S 28 T 46 N R 21 W | Concrete Tee beam | -- | 1920 | 1991 | 36.1 | 36.1 | Fair | 70.7 | 15717 |
NBI report | BRYSON RD | SMALL CR | S 17 T 44 N R 22 W | Concrete Culvert (2 spans) | -- | 1925 | -- | 12.1 | 24.9 | Good | 65.8 | 22039 |
NBI report | CARPENTER RD | MCGEE BR | S 33 T 45 N R 20 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1925 | -- | 12.5 | 29.9 | Fair | 47.2 | 19094 |
NBI report Bridgehunter | CLAYCOMB RD | TURKEY CR | S 34 T 47 N R 21 W | Steel Truss - Thru | -- | 1925 | -- | 60.0 | 62.0 | Fair | 34.0 | 24025 |
NBI report | ELDORADO RD | SMALL CR | S 31 T 45 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 24.9 | 24.9 | Fair | 32.1 | 23061 |
NBI report | ELM BRANCH RD | WINDSOR CTY LK SPL | S 7 T 43 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 22.0 | 23.0 | Fair | 42.8 | 21186 |
NBI report | FOWLER RD | SMALL BR | S 23 T 47 N R 22 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1925 | -- | 14.1 | 27.9 | Poor | 35.9 | 14856 |
NBI report | LAMMS LN | SMALL CR | S 17 T 45 N R 20 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 26.9 | 28.9 | Fair | 86.8 | 19298 |
NBI report | MCCURDY RD | SMALL CR | S 5 T 46 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 24.9 | 26.9 | Fair | 36.0 | 15898 |
NBI report | OXLINE RD | SMALL CR | S 9 T 44 N R 23 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1925 | -- | 20.0 | 49.9 | Fair | 48.7 | 21656 |
NBI report | PLEASANT VIEW RD | S FLAT CR | S 8 T 43 N R 22 W | Steel Culvert (2 spans) | -- | 1925 | -- | 12.1 | 24.9 | Poor | 40.0 | 20982 |
NBI report | SHERNAMAN RD | LONG BR | S 32 T 46 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1925 | -- | 35.1 | 36.1 | Fair | 68.9 | 23374 |
NBI report | SWISHER RD | PEPPER CR | S 32 T 44 N R 23 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1925 | -- | 19.0 | 40.0 | Fair | 25.0 | 21516 |
NBI report | REED RD | TRIB OF BASIN FK | S 13 T 44 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1925 | 1987 | 27.9 | 29.9 | Good | 40.0 | 24046 |
NBI report | THORNLEIGH RD | SMALL CR | S 21 T 46 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1925 | 1995 | 27.9 | 28.9 | Fair | 47.3 | 16304 |
NBI report | MCCURDY RD | SMALL CR | S 31 T 47 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1925 | 2004 | 23.0 | 24.9 | Fair | 62.0 | 16067 |
NBI report Bridgehunter | SWOPE RD | CEDAR CR | S 15 T 46 N R 21 W | Concrete Slab (3 spans) | -- | 1926 | -- | 24.9 | 79.1 | Poor | 34.0 | 24029 |
NBI report Bridgehunter | TANEY RD | TRIB OF SEWER BR | S 10 T 46 N R 21 W | Concrete Tee beam (3 spans) | -- | 1926 | -- | 36.1 | 111.9 | Fair | 52.5 | 24028 |
NBI report Bridgehunter | RT H S | SEWER BR | S 21 T 46 N R 21 W | Concrete Tee beam | -- | 1927 | -- | 32.8 | 33.1 | Fair | 49.8 | 9476 |
NBI report | MO 52 E | CR | S 1 T 43 N R 22 W | Concrete Culvert (2 spans) | -- | 1928 | -- | 12.1 | 24.9 | Fair | 99.0 | 5166 |
NBI report | MO 52 E | HENRY CR | S 6 T 43 N R 21 W | Concrete Culvert (2 spans) | -- | 1928 | -- | 12.1 | 26.6 | Fair | 99.0 | 5167 |
NBI report | US 65 S | BRENER CR | S 19 T 44 N R 21 W | Concrete Culvert (2 spans) | -- | 1928 | 1978 | 7.9 | 24.0 | Fair | 79.3 | 5103 |
NBI report | MO 52 E | CR | S 6 T 43 N R 22 W | Concrete Slab | -- | 1929 | -- | 24.0 | 26.9 | Fair | 31.1 | 5151 |
NBI report Bridgehunter | MO 52 E | FLAT CR | S 4 T 43 N R 22 W | Concrete Tee beam (3 spans) | -- | 1929 | -- | 32.5 | 98.1 | Poor | 40.6 | 5152 |
NBI report | CHAMBERLIN RD | SMALL CR | S 2 T 47 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 28.9 | 29.9 | Poor | 25.9 | 14562 |
NBI report Bridgehunter | CLAYCOMB RD | MUDDY CR | S 34 T 47 N R 21 W | Steel Truss - Thru | -- | 1930 | -- | 120.1 | 122.1 | Poor | 32.9 | 24027 |
NBI report | HAZEL HILL RD | GRASSY CR | S 23 T 48 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 26.9 | 27.9 | Fair | 38.3 | 14158 |
NBI report | HOUSTON RD | SMALL CR | S 32 T 48 N R 22 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1930 | -- | 13.1 | 27.9 | Fair | 37.8 | 14349 |
NBI report | MCGEE RD | TRIB TO WALNUT CR | S 36 T 45 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 28.9 | 30.8 | Fair | 42.3 | 23996 |
NBI report | SPRING FORK RD | SPG FK LK DRAIN DT | S 21 T 44 N R 21 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1930 | -- | 29.9 | 61.0 | Poor | 55.4 | 20643 |
NBI report | WALNUT GROVE RD | SMALL CR | S 11 T 46 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 29.9 | 30.8 | Fair | 39.8 | 15068 |
NBI report | E PRARIE GROVE RD | S FORK | S 5 T 46 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1930 | 1986 | 35.1 | 38.1 | Fair | 48.0 | 12516 |
NBI report Bridgehunter | CHEVALIER RD | MUDDY CR | S 30 T 46 N R 22 W | Steel Truss - Thru | -- | 1930 | 1995 | 96.1 | 146.0 | Poor | 22.8 | 23737 |
NBI report | SACAJAWEA RD | TRIB OF FLAT CR | S 18 T 45 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1930 | 2007 | 28.9 | 30.8 | Fair | 54.1 | 22658 |
NBI report | WARE RD | S FLAT CR | S 28 T 44 N R 22 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1930 | 2007 | 30.8 | 56.1 | Poor | 27.2 | 22122 |
NBI report | MO 127 S | FLAT CR | S 14 T 44 N R 23 W | Concrete Culvert (2 spans) | -- | 1933 | -- | 12.1 | 26.2 | Fair | 77.6 | 8736 |
NBI report | RT D E | S FK BLACKWATER RV | S 11 T 47 N R 23 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1933 | -- | 48.9 | 167.0 | Poor | 30.5 | 8865 |
NBI report | RT D E | HEATHS CR | S 15 T 47 N R 22 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1933 | -- | 24.9 | 73.2 | Poor | 26.4 | 8866 |
NBI report | RT D E | HEATHS CR | S 17 T 47 N R 22 W | Concrete Culvert (2 spans) | -- | 1933 | -- | 9.8 | 21.0 | Fair | 74.9 | 9087 |
NBI report | RT D E | HEATHS CR | S 16 T 47 N R 22 W | Concrete Culvert (2 spans) | -- | 1933 | -- | 9.8 | 21.3 | Fair | 85.9 | 9088 |
NBI report | ELM BRANCH RD | SMALL CR | S 6 T 43 N R 22 W | Steel Culvert (2 spans) | -- | 1935 | -- | 12.1 | 24.9 | Good | 55.2 | 21070 |
NBI report | PACIFIC SCHOOL RD | CREEK | S 28 T 44 N R 20 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1935 | -- | 29.9 | 90.9 | Fair | 51.8 | 20500 |
NBI report | WHITE RD | SMALL CR | S 12 T 44 N R 23 W | Concrete Culvert (2 spans) | -- | 1935 | -- | 11.2 | 23.0 | Poor | 57.8 | 22016 |
NBI report | RT M S | BREAKFAST BR | S 13 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1938 | 2018 | 35.1 | 80.1 | Poor | 30.9 | 9598 |
NBI report | RT M S | WELLER CR | S 22 T 44 N R 20 W | Concrete Culvert (2 spans) | -- | 1939 | -- | 12.1 | 24.9 | Good | 77.1 | 9625 |
NBI report Bridgehunter | RT M S | LAKE CR | S 22 T 44 N R 20 W | Concrete Tee beam (4 spans) | -- | 1939 | -- | 52.5 | 165.0 | Fair | 39.1 | 9626 |
NBI report Bridgehunter | MAHIN RD | LONG BR OF MUDDY C | S 33 T 46 N R 23 W | Steel Truss - Thru | -- | 1940 | -- | 60.0 | 60.0 | Fair | 34.1 | 23505 |
NBI report | RT M S | LAKE CR | S 35 T 44 N R 20 W | Concrete Culvert (2 spans) | -- | 1940 | -- | 12.1 | 24.6 | Fair | 92.0 | 9645 |
NBI report Bridgehunter | WALNUT GROVE RD | LIT MUDDY CR | S 11 T 46 N R 22 W | Steel Girder and floorbeam system | -- | 1940 | -- | 44.0 | 44.9 | Fair | 44.2 | 15073 |
NBI report | WESTERMIER RD | SPRING FK | S 35 T 44 N R 21 W | Concrete Slab (2 spans) | -- | 1940 | -- | 14.1 | 26.9 | Fair | 58.8 | 20584 |
NBI report Bridgehunter | MO 127 S | BASIN FK CR | S 12 T 44 N R 23 W | Concrete Tee beam (3 spans) | -- | 1941 | -- | 37.4 | 112.9 | Poor | 2.0 | 9669 |
NBI report | WOODLAND | SMALL CR | S 32 T 47 N R 20 W | Steel Stringer/Multi-beam or girder | -- | 1945 | 2003 | 24.9 | 30.8 | Fair | 81.0 | 17445 |
NBI report | RT B E | REED BR | S 32 T 45 N R 22 W | Concrete Culvert (2 spans) | -- | 1947 | -- | 12.1 | 27.2 | Fair | 57.8 | 9722 |
NBI report | MO 127 S | FLAT CR | S 12 T 44 N R 23 W | Concrete Culvert (2 spans) | -- | 1949 | -- | 9.8 | 21.3 | Good | 86.1 | 6232 |
NBI report Bridgehunter | RT O S | MUDDY CR | S 33 T 47 N R 20 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1949 | -- | 70.2 | 196.9 | Poor | 41.0 | 9842 |
NBI report Bridgehunter | CURTIS RD | MUDDY CR | S 9 T 45 N R 23 W | Steel Truss - Thru | Closed | 1950 | -- | 60.0 | 62.0 | Poor | 25.0 | 23209 |
NBI report Bridgehunter | WILDWOOD RD | HEATHS CR | S 27 T 48 N R 21 W | Steel Truss - Thru | -- | 1950 | -- | 81.0 | 83.0 | Fair | 63.8 | 24041 |
NBI report | ADAIR RD | TRIB S FK BLACKWAT | S 33 T 46 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1950 | 1987 | 27.9 | 28.9 | Fair | 71.0 | 12633 |
NBI report | RT BB E | GREER BR | S 35 T 48 N R 21 W | Concrete Culvert (3 spans) | -- | 1952 | -- | 11.2 | 34.8 | Fair | 73.6 | 7544 |
NBI report | RT Y E | WALNUT CR | S 1 T 45 N R 23 W | Concrete Culvert (2 spans) | -- | 1953 | -- | 12.1 | 27.6 | Fair | 87.6 | 6321 |
NBI report | RT Y E | ELK CR | S 5 T 45 N R 23 W | Concrete Culvert (2 spans) | -- | 1953 | -- | 11.2 | 25.3 | Fair | 66.5 | 6322 |
NBI report | RT Y E | COON CR | S 3 T 45 N R 22 W | Concrete Culvert (2 spans) | -- | 1953 | -- | 12.1 | 25.3 | Fair | 66.5 | 6323 |
NBI report | RT Y E | COON CR | S 2 T 45 N R 22 W | Concrete Culvert (2 spans) | -- | 1953 | -- | 12.1 | 24.9 | Fair | 66.5 | 6324 |
NBI report | RT Y E | COON CR | S 1 T 45 N R 22 W | Concrete Culvert (2 spans) | -- | 1953 | -- | 9.8 | 20.7 | Fair | 66.5 | 6325 |
NBI report | RT W S | KAHRS BR | S 23 T 45 N R 20 W | Concrete Culvert (2 spans) | -- | 1954 | -- | 12.1 | 24.9 | Good | 79.7 | 7600 |
NBI report | US 50 E | BRUSHY CR | S 14 T 46 N R 23 W | Concrete Culvert (2 spans) | -- | 1954 | 1972 | 7.9 | 24.6 | Fair | 84.3 | 4686 |
NBI report | HARDING RD | BASIN FK | S 4 T 44 N R 22 W | Steel Girder and floorbeam system (2 spans) | -- | 1955 | -- | 27.9 | 59.1 | Poor | 25.9 | 22443 |
NBI report | RT K S | MAY BR | S 20 T 48 N R 22 W | Concrete Culvert (2 spans) | -- | 1955 | -- | 9.8 | 20.7 | Good | 83.0 | 7963 |
NBI report Bridgehunter | RT Y E | MUDDY CR | S 3 T 45 N R 23 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | 2009 | 69.9 | 194.9 | Fair | 56.1 | 7778 |
NBI report | RT CC E | BUFFALO CR | S 33 T 48 N R 22 W | Concrete Culvert (2 spans) | -- | 1956 | -- | 9.8 | 24.3 | Fair | 87.8 | 6732 |
NBI report | RT ZZ S | CANADA BR | S 3 T 43 N R 22 W | Concrete Culvert (2 spans) | -- | 1959 | -- | 11.2 | 22.6 | Fair | 91.0 | 7153 |
NBI report Bridgehunter | RT E S | BASIN FK | S 34 T 45 N R 22 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2009 | 60.0 | 164.1 | Good | 65.1 | 7202 |
NBI report Bridgehunter | RT E S | FLAT CR | S 15 T 44 N R 22 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2009 | 100.1 | 264.1 | Good | 72.2 | 7203 |
NBI report Bridgehunter | GLENN RD | SHAVER CR | S 15 T 46 N R 20 W | Steel Girder and floorbeam system | -- | 1960 | -- | 77.1 | 80.1 | Fair | 47.3 | 17891 |
NBI report | RT J S | GREER BR | S 15 T 47 N R 21 W | Concrete Culvert (3 spans) | -- | 1960 | -- | 12.1 | 37.4 | Fair | 94.2 | 7363 |
NBI report | RT J S | HEATHS CR | S 7 T 47 N R 20 W | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 24.6 | Fair | 99.2 | 7364 |
NBI report | BLUHM RD | SMALL CR | S 22 T 45 N R 20 W | Steel Stringer/Multi-beam or girder | -- | 1960 | 2004 | 28.9 | 29.9 | Fair | 82.0 | 18908 |
NBI report | INDUSTRIAL RD | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Slab (3 spans) | -- | 1961 | -- | 11.2 | 33.1 | Fair | 67.7 | 23172 |
NBI report | GENTRY RD | CEDAR CR | S 26 T 47 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1962 | -- | 39.0 | 40.0 | Good | 48.3 | 18232 |
NBI report | US 65 S | SEWER CR | S 33 T 46 N R 21 W | Concrete Culvert (2 spans) | -- | 1962 | -- | 14.1 | 28.9 | Fair | 74.0 | 836 |
NBI report | US 65 S | MO 765 | S 5 T 45 N R 21 W | Concrete Slab (3 spans) | -- | 1962 | -- | 63.0 | 155.5 | Fair | 69.5 | 838 |
NBI report | US 65 S | CR | S 5 T 45 N R 21 W | Concrete Culvert (2 spans) | -- | 1962 | -- | 9.8 | 20.7 | Fair | 60.8 | 839 |
NBI report | WARREN AVE | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Culvert (2 spans) | -- | 1962 | -- | 9.8 | 22.0 | Good | 74.8 | 23169 |
NBI report | US 65 S | MOC RR | S 5 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | 2008 | 64.0 | 235.2 | Fair | 74.0 | 837 |
NBI report | RT EE S | MUDDY CR | S 36 T 47 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2018 | 89.9 | 360.9 | Poor | 28.3 | 7380 |
NBI report Bridgehunter | RT H S | MUDDY CR | S 18 T 46 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 2009 | 75.1 | 272.3 | Fair | 74.4 | 529 |
NBI report Bridgehunter | RT U S | FLAT CR | S 22 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 2014 | 120.1 | 478.0 | Fair | 39.2 | 1806 |
NBI report | ANDERSON SCHOOL RD | WALNUT CR | S 2 T 45 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1963 | 2015 | 78.1 | 79.1 | Good | 84.5 | 20669 |
NBI report | US 65 S | REIDS BR | S 9 T 46 N R 21 W | Concrete Culvert (2 spans) | -- | 1964 | 1977 | 14.1 | 28.5 | Fair | 82.5 | 583 |
NBI report | SOUTHFORK RD | S FORK | S 26 T 48 N R 23 W | Steel Girder and floorbeam system | -- | 1964 | 1989 | 75.1 | 81.0 | Fair | 75.9 | 13899 |
NBI report | US 65 S | TURKEY CR | S 33 T 47 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1996 | 91.9 | 243.5 | Poor | 58.3 | 797 |
NBI report | US 65 S | CEDAR CR | S 16 T 46 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2009 | 100.1 | 264.1 | Good | 74.4 | 584 |
NBI report | US 65 S | MUDDY CR | S 33 T 47 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2017 | 91.9 | 375.0 | Fair | 70.5 | 798 |
NBI report | RT M S | WALNUT CR | S 30 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2018 | 68.9 | 180.1 | Poor | 51.1 | 9600 |
NBI report | CLONEY RD | SMALL CR | S 19 T 46 N R 21 W | Prestressed Slab | -- | 1965 | -- | 28.9 | 29.9 | Fair | 88.7 | 15448 |
NBI report | OAK POINT RD | SMALL CR | S 25 T 47 N R 23 W | Steel Girder and floorbeam system | -- | 1966 | 2008 | 39.0 | 43.0 | Fair | 40.3 | 13440 |
NBI report Bridgehunter | US 65 S | HEATHS CR | S 27 T 48 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 2009 | 85.0 | 225.1 | Good | 80.6 | 585 |
NBI report Bridgehunter | US 65 N | HEATHS CR | S 27 T 48 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1967 | 2009 | 85.0 | 225.1 | Good | 80.7 | 1983 |
NBI report Bridgehunter | MAJOR RD | HEATHS CR | S 30 T 48 N R 20 W | Steel Girder and floorbeam system (2 spans) | -- | 1968 | -- | 79.1 | 118.1 | Fair | 43.2 | 16765 |
NBI report | SCHENK RD | MUDDY CR | S 17 T 45 N R 23 W | Steel Girder and floorbeam system | -- | 1970 | -- | 73.2 | 78.1 | Fair | 54.0 | 23239 |
NBI report | TEVIS RD | SMALL CR | S 2 T 46 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1970 | -- | 35.1 | 36.1 | Fair | 71.2 | 14998 |
NBI report | W MAIN ST | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Slab (3 spans) | -- | 1970 | -- | 12.1 | 40.0 | Fair | 35.6 | 23176 |
NBI report | US 50 E | MUDDY CR | S 35 T 46 N R 22 W | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1972 | -- | 63.0 | 289.1 | Fair | 98.7 | 2311 |
NBI report | US 50 W | MUDDY CR | S 35 T 46 N R 22 W | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1972 | -- | 63.0 | 289.1 | Fair | 99.7 | 2312 |
NBI report | CRAWFORD RD | BEAVERDAM CR | S 22 T 47 N R 23 W | Concrete Channel beam | -- | 1973 | -- | 46.9 | 49.9 | Fair | 46.9 | 13509 |
NBI report | W PRAIRIE RD | ELK CR | S 30 T 47 N R 23 W | Concrete Channel beam | -- | 1973 | -- | 32.2 | 35.1 | Fair | 57.3 | 12477 |
NBI report | ANDERSON SCHOOL RD | SPRING FK | S 4 T 44 N R 21 W | Concrete Channel beam (3 spans) | -- | 1974 | -- | 46.9 | 115.2 | Fair | 54.8 | 20710 |
NBI report | LUTMAN RD | LAKE CR | S 13 T 44 N R 20 W | Concrete Channel beam (3 spans) | -- | 1974 | -- | 40.0 | 110.9 | Fair | 56.1 | 20345 |
NBI report | S WOODLAWN DR | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Culvert (3 spans) | -- | 1974 | -- | 11.2 | 33.1 | Fair | 67.8 | 23171 |
NBI report | STATE FAIR BLVD NB | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Culvert (3 spans) | -- | 1974 | -- | 13.1 | 39.0 | Good | 56.5 | 23175 |
NBI report | STATE FAIR BLVD SB | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Culvert (2 spans) | -- | 1974 | -- | 15.1 | 30.8 | Good | 67.8 | 23170 |
NBI report | US 65 N | FLAT CR | S 20 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | -- | 100.1 | 370.1 | Poor | 68.1 | 2309 |
NBI report | US 65 S | FLAT CR | S 20 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | -- | 100.1 | 370.1 | Poor | 68.1 | 2308 |
NBI report | MCCUBBIN RD | HEATHS CR | S 2 T 47 N R 22 W | Steel Girder and floorbeam system | -- | 1974 | 2016 | 33.5 | 39.0 | Fair | 25.9 | 14588 |
NBI report | SMASAL RD | WALNUT CR | S 12 T 44 N R 21 W | Steel Girder and floorbeam system | -- | 1975 | 2018 | 37.1 | 38.7 | Fair | 47.2 | 20208 |
NBI report Bridgehunter | RICHEY RD | LIT MUDDY CR | S 16 T 46 N R 22 W | Steel Girder and floorbeam system (3 spans) | -- | 1976 | -- | 35.1 | 71.9 | Fair | 27.2 | 15372 |
NBI report | SEDALIA RD | CREEK | S 33 T 46 N R 21 W | Concrete Slab (2 spans) | -- | 1976 | -- | 15.1 | 30.8 | Fair | 47.8 | 23173 |
NBI report | DOVE RD | SMALL CR | S 5 T 44 N R 22 W | Prestressed Tee beam (3 spans) | -- | 1977 | -- | 43.0 | 129.9 | Fair | 75.8 | 21975 |
NBI report | US 65 N | TURKEY CR | S 33 T 47 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 91.9 | 243.1 | Fair | 97.0 | 2608 |
NBI report | US 65 N | MUDDY CR | S 33 T 47 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 91.9 | 375.3 | Poor | 70.4 | 2609 |
NBI report | US 65 N | CEDAR CR | S 16 T 46 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 100.1 | 264.4 | Fair | 97.5 | 2610 |
NBI report | BEACON AVE | BRUSHY CR | S 5 T 45 N R 21 W | Concrete Culvert (2 spans) | -- | 1978 | -- | 11.2 | 22.0 | Good | 74.8 | 23168 |
NBI report | SMASAL RD | SPRING FK | S 16 T 44 N R 21 W | Prestressed Tee beam (3 spans) | -- | 1978 | -- | 49.9 | 154.9 | Good | 86.8 | 20662 |
NBI report | WM PARKHURST DR | CREEK | S 33 T 46 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1978 | -- | 23.0 | 37.1 | Poor | 41.0 | 23174 |
NBI report | MALTSBARGER RD | HENRY CR | S 14 T 44 N R 22 W | Steel Girder and floorbeam system (2 spans) | -- | 1980 | 2002 | 35.1 | 69.9 | Fair | 99.0 | 28942 |
NBI report | MO 52 E | FLAT CR | S 1 T 43 N R 23 W | Prestressed Tee beam (3 spans) | -- | 1986 | -- | 43.6 | 129.9 | Fair | 94.7 | 3659 |
NBI report | MCFARLAND RD | MUDDY CR | S 5 T 46 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 65.0 | 187.0 | Good | 95.0 | 18052 |
NBI report | RT HH E | SHAVER CR | S 14 T 46 N R 20 W | Prestressed Tee beam (3 spans) | -- | 1988 | -- | 46.6 | 139.1 | Fair | 85.2 | 3972 |
NBI report | SMELSER RD | MUDDY CR | S 4 T 46 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 70.9 | 183.1 | Good | 88.0 | 16044 |
NBI report | WALK RD | HEATHS CR | S 20 T 48 N R 20 W | Prestressed Tee beam (3 spans) | -- | 1988 | -- | 55.4 | 166.0 | Fair | 96.0 | 16796 |
NBI report | RT DD E | LAKE CR | S 25 T 45 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1989 | -- | 62.7 | 188.0 | Good | 98.7 | 3976 |
NBI report | SOUTHFORK RD | BUNCOMB BR | S 26 T 48 N R 23 W | Concrete Culvert (2 spans) | -- | 1989 | -- | 14.1 | 28.9 | Good | 97.0 | 13914 |
NBI report | WHITEMAN RD | CHEESE CR | S 4 T 43 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 54.1 | 55.1 | Fair | 80.0 | 28478 |
NBI report | MATHER RD | HENRY CR | S 23 T 44 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1991 | -- | 83.0 | 83.0 | Good | 96.0 | 22273 |
NBI report | REAM SPR RD | MUDDY CR | S 13 T 47 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 80.1 | 233.0 | Good | 98.0 | 17706 |
NBI report | TRICKUM RD | HEATHS CR | S 27 T 48 N R 21 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 44.9 | 120.1 | Good | 97.0 | 16532 |
NBI report | RATTLESNAKE RD | FLAT CR | S 24 T 45 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 92.9 | 232.0 | Good | 100.0 | 19039 |
NBI report | ELM BRANCH RD | FLAT CR | S 2 T 43 N R 23 W | Prestressed Tee beam (3 spans) | -- | 1993 | -- | 40.0 | 120.1 | Fair | 100.0 | 21051 |
NBI report | MANILA RD | SPR FK FLAT CR | S 28 T 44 N R 21 W | Steel Culvert (3 spans) | -- | 1993 | -- | 9.8 | 41.0 | Fair | 79.8 | 20813 |
NBI report | HOUSTON RD | HEATHS CR | S 5 T 47 N R 21 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 60.0 | 183.1 | Good | 100.0 | 16404 |
NBI report | OXLINE RD | PEPPER CR | S 33 T 44 N R 23 W | Steel Girder and floorbeam system | -- | 1994 | -- | 38.1 | 40.0 | Good | 85.8 | 21550 |
NBI report Bridgehunter | WARE RD | FLAT CR | S 29 T 44 N R 22 W | Steel Girder and floorbeam system | -- | 1994 | -- | 78.1 | 81.0 | Fair | 59.5 | 22118 |
NBI report | FOWLER RD | TRIB OF HEATH CR | S 21 T 47 N R 22 W | Steel Girder and floorbeam system | -- | 1995 | -- | 27.9 | 29.9 | Fair | 96.0 | 14808 |
NBI report | HILLVIEW RD | SMALL STR | S 9 T 47 N R 22 W | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 25.9 | 29.9 | Fair | 96.0 | 14422 |
NBI report | MALTSBARGER RD | TRIB OF S FLAT CR | S 18 T 44 N R 21 W | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 32.2 | 33.1 | Fair | 73.4 | 22306 |
NBI report | PRICE RD | BEAR BR | S 9 T 47 N R 9 W | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 20.0 | 23.0 | Good | 96.0 | 12283 |
NBI report | CRYSTAL SPRINGS RD | SMALL CR | S 24 T 46 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 58.1 | 64.0 | Good | 99.0 | 23743 |
NBI report | WANAMAKER RD | HEATHS CR | S 25 T 48 N R 21 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 42.0 | 127.0 | Good | 99.0 | 16727 |
NBI report | 24TH ST | DRAIN DTCH | S 10 T 45 N R 21 W | Concrete Slab (3 spans) | -- | 1997 | -- | 8.9 | 27.9 | Good | 71.3 | 28185 |
NBI report | DILTHY RD | TRIB LAMINE RVR | S 12 T 47 N R 20 W | Metal Culvert | -- | 1997 | -- | 20.0 | 20.0 | Good | 95.9 | 30363 |
NBI report | FRISTO RD | MUDDY CR | S 35 T 47 N R 21 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1997 | -- | 68.9 | 162.1 | Good | 95.0 | 17284 |
NBI report | MATHER RD | SMALL CR | S 23 T 44 N R 22 W | Steel Culvert (2 spans) | -- | 1997 | -- | 9.8 | 24.9 | Good | 97.0 | 22267 |
NBI report | SCHONDELMAIER RD | BUFFALO CR | S 28 T 48 N R 22 W | Steel Culvert (3 spans) | -- | 1997 | -- | 11.8 | 45.9 | Good | 97.0 | 14177 |
NBI report | COUNTY LINE RD | E FK TEBO CR | S 7 T 43 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1998 | -- | 69.9 | 75.1 | Good | 89.0 | 21261 |
NBI report | THOMPSON RD | LONG BR MUDDY CR | S 6 T 45 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 1998 | -- | 66.9 | 71.9 | Good | 99.0 | 23335 |
NBI report | HOUSTON RD | SMALL CR | S 36 T 48 N R 22 W | Metal Culvert | -- | 1999 | -- | 20.3 | 20.3 | Good | 97.0 | 14344 |
NBI report | QUISENBERRY RD | CAMP BR | S 26 T 45 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 1999 | -- | 67.9 | 71.9 | Good | 94.0 | 22724 |
NBI report | BEE BRANCH RD | TRIB OF BEE BR | S 29 T 46 N R 23 W | Steel Culvert (2 spans) | -- | 2000 | -- | 10.5 | 25.9 | Good | 97.0 | 28468 |
NBI report | DRESDEN RD | MUDDY CR | S 33 T 46 N R 22 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2000 | -- | 64.0 | 153.9 | Good | 99.0 | 28953 |
NBI report | BLUHM RD | TRIB OF FLAT CR | S 24 T 45 N R 20 W | Metal Culvert | -- | 2001 | -- | 24.0 | 24.0 | Good | 97.0 | 28659 |
NBI report | CAMP BRANCH RD | CAMP CR | S 20 T 45 N R 22 W | Metal Culvert | -- | 2001 | -- | 25.9 | 36.1 | Good | 97.0 | 28736 |
NBI report | CAMP BRANCH RD | TRIB OF COON CR | S 9 T 45 N R 22 W | Metal Culvert | -- | 2001 | -- | 25.3 | 25.3 | Good | 97.0 | 28944 |
NBI report | RATTLESNAKE HILL | FLAT CR | S 26 T 45 N R 20 W | Metal Culvert | -- | 2001 | -- | 23.0 | 23.0 | Good | 96.0 | 30364 |
NBI report | 24TH ST | DRAIN DTCH | S 10 T 45 N R 21 W | Concrete Culvert (2 spans) | -- | 2002 | -- | 9.8 | 25.6 | Good | 90.9 | 29808 |
NBI report | CAMP BRANCH RD | BR OF CAMP CR | S 25 T 45 N R 22 W | Metal Culvert | -- | 2002 | -- | 25.9 | 25.9 | Good | 97.0 | 28941 |
NBI report | HICKORY POINT RD | ELK FK MUDDY RVR | S 28 T 45 N R 23 W | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 75.1 | 76.8 | Good | 94.5 | 28958 |
NBI report | LEE RD | SHAVER CR | S 2 T 46 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2002 | -- | 64.0 | 153.9 | Good | 100.0 | 28939 |
NBI report | LOOKOUT RD | MUDDY CR | S 25 T 47 N R 20 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2002 | -- | 77.1 | 187.0 | Good | 99.0 | 28943 |
NBI report | MAPLE GROVE RD | PEPPER CR | S 2 T 43 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2002 | -- | 55.1 | 60.0 | Good | 100.0 | 29446 |
NBI report | MCANINCH RD | HEATHS CR | S 10 T 47 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 2002 | -- | 56.1 | 61.0 | Good | 100.0 | 29455 |
NBI report | MCGEE RD | MCGEE BR | S 32 T 45 N R 20 W | Metal Culvert | -- | 2002 | -- | 20.3 | 20.3 | Good | 97.0 | 28946 |
NBI report | S GRAND AVE | SPRING CR | S 33 T 45 N R 21 W | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2002 | 2013 | 27.9 | 61.0 | Good | 83.4 | 29448 |
NBI report | RT AA E | ELK FK OF MUDDY CR | S 17 T 45 N R 23 W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 61.0 | 131.9 | Good | 94.5 | 30073 |
NBI report | SMASAL RD | BR OF FLAT CR | S 1 T 44 N R 22 W | Metal Culvert | -- | 2003 | -- | 21.7 | 21.7 | Good | 97.0 | 30366 |
NBI report | TYLER RD | TRIB TO BLACKWATER | S 5 T 47 N R 23 W | Metal Culvert | -- | 2003 | -- | 24.0 | 24.0 | Good | 96.0 | 30362 |
NBI report | WHITEMAN RD | SHAVER CR | S 31 T 44 N R 20 W | Metal Culvert | -- | 2003 | -- | 23.6 | 23.6 | Good | 96.0 | 30365 |
NBI report | GRIESSEN RD | SMALL CR | S 31 T 46 N R 20 W | Prestressed Stringer/Multi-beam or girder | -- | 2004 | -- | 65.0 | 67.9 | Good | 94.4 | 30885 |
NBI report | HICKORY POINT RD | W ELK FK OF MUDDY | S 28 T 45 N R 23 W | Metal Culvert | -- | 2004 | -- | 26.6 | 26.6 | Good | 97.0 | 30367 |
NBI report | MCGRUDER RD | HEATHS CR | S 1 T 47 N R 22 W | Prestressed Stringer/Multi-beam or girder | -- | 2004 | -- | 89.6 | 91.9 | Good | 99.0 | 30369 |
NBI report | WESTMORELAND RD | TEBO CR | S 1 T 44 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 62.3 | 65.6 | Good | 100.0 | 30368 |
NBI report | RIECKHOFF RD | TRIB TO LIT MUDDY | S 10 T 46 N R 22 W | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 44.9 | 49.9 | Good | 100.0 | 31262 |
NBI report | TEVEBAUGH RD | TRIB TO BLACKWATER | S 19 T 48 N R 22 W | Metal Culvert | -- | 2005 | -- | 20.0 | 20.0 | Good | 99.0 | 30886 |
NBI report | WHITEMAN RD | LAKE CR | S 4 T 43 N R 20 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2005 | -- | 53.2 | 127.0 | Good | 100.0 | 31172 |
NBI report | GLENN RD | SMALL CR | S 11 T 46 N R 20 W | Metal Culvert | -- | 2007 | -- | 22.0 | 22.0 | Good | 97.0 | 32336 |
NBI report | TEVEBAUGH RD | MAY BR | S 20 T 48 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 2007 | -- | 54.5 | 57.7 | Good | 99.0 | 31912 |
NBI report | SMELSER RD | SMELSER CR | S 5 T 46 N R 21 W | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 75.5 | 78.1 | Good | 99.0 | 32379 |
NBI report | SMELSER RD | SMELSER CR | S 4 T 46 N R 21 W | Metal Culvert | -- | 2008 | -- | 26.2 | 26.2 | Good | 97.0 | 32381 |
NBI report | EASTER RD | W ELK FK | S 32 T 45 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2009 | -- | 39.4 | 42.0 | Good | 99.0 | 32674 |
NBI report | WELLS RD | CROOKED CR | S 6 T 44 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2009 | -- | 51.8 | 55.1 | Good | 99.0 | 32574 |
NBI report | CRYSTAL SPRINGS RD | BRUSHY CR | S 27 T 46 N R 23 W | Metal Culvert | -- | 2010 | -- | 24.0 | 24.0 | Good | 97.0 | 33819 |
NBI report | EASTER RD | ELK CR | S 34 T 45 N R 23 W | Metal Culvert | -- | 2010 | -- | 25.9 | 25.9 | Good | 97.0 | 32992 |
NBI report | KNIGHT RD | SMALL CR | S 4 T 46 N R 22 W | Metal Culvert | -- | 2010 | -- | 25.9 | 25.9 | Good | 97.0 | 33319 |
NBI report | MAHIN RD | BUSHY CR | S 27 T 46 N R 23 W | Metal Culvert | -- | 2010 | -- | 24.0 | 24.0 | Good | 97.0 | 33820 |
NBI report | MO 127 N | BEE BR | S 34 T 48 N R 23 W | Prestressed Box Beam or girders - Single or Spread | -- | 2010 | -- | 89.9 | 91.5 | Good | 88.3 | 32930 |
NBI report | MO 127 S | MUDDY CR | S 35 T 46 N R 23 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2010 | -- | 49.9 | 132.6 | Good | 81.2 | 32989 |
NBI report | MO 127 S | MUDDY CR | S 35 T 46 N R 23 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2010 | -- | 65.0 | 194.9 | Good | 81.1 | 33031 |
NBI report | MO 127 S | BEAR BR BLACKWATER | S 3 T 47 N R 23 W | Prestressed Box beam or girders - Multiple | -- | 2010 | -- | 75.1 | 75.1 | Good | 88.3 | 33047 |
NBI report | MO 127 S | FLAT CR | S 35 T 44 N R 26 W | Prestressed Box Beam or girders - Single or Spread | -- | 2010 | -- | 80.1 | 82.0 | Good | 80.9 | 33115 |
NBI report | MO 127 S | S FK BLACKWATER RV | S 27 T 47 N R 23 W | Prestressed Box beam or girders - Multiple (2 spans) | -- | 2010 | -- | 85.0 | 171.9 | Fair | 87.7 | 33231 |
NBI report | MO 52 E | PERSIMMON CR | S 34 T 44 N R 23 W | Prestressed Box Beam or girders - Single or Spread | -- | 2010 | -- | 80.1 | 82.0 | Good | 79.4 | 33240 |
NBI report | ROWLETTA RD | ELK CR | S 29 T 47 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2010 | -- | 60.0 | 60.0 | Good | 99.0 | 33843 |
NBI report | RT B E | CAMP BR CR | S 25 T 45 N R 22 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2010 | -- | 49.9 | 122.7 | Fair | 89.9 | 33201 |
NBI report | RT M S | FLAT CREEK | S 24 T 45 N R 21 W | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2010 | -- | 55.1 | 107.0 | Good | 79.6 | 33234 |
NBI report | RT O S | LIT SHAVER CR | S 20 T 46 N R 20 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2010 | -- | 44.9 | 135.8 | Good | 81.9 | 33202 |
NBI report | RT T N | MUDDY CR | S 16 T 46 N R 22 W | Prestressed Box Beam or girders - Single or Spread | -- | 2010 | -- | 95.1 | 96.5 | Good | 87.8 | 32925 |
NBI report | RT U N | SPRING FK CR | S 27 T 44 N R 21 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2010 | -- | 60.0 | 130.6 | Good | 79.8 | 33316 |
NBI report | RT HH E | CEDAR CR | S 23 T 46 N R 21 W | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2011 | -- | 60.0 | 107.9 | Fair | 94.9 | 33485 |
NBI report | RT V E | SPRING FK BR | S 21 T 44 N R 21 W | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 2011 | -- | 60.0 | 162.7 | Fair | 80.9 | 33349 |
NBI report | RT W N | FLAT CR | S 26 T 45 N R 20 W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2011 | -- | 109.9 | 252.6 | Good | 81.3 | 33618 |
NBI report | GARRISON RD | MCGEE BR | S 33 T 45 N R 20 W | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 69.9 | 69.9 | Good | 99.0 | 34262 |
NBI report | HIGGINS RD | BEAR CR | S 3 T 47 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2013 | -- | 65.0 | 68.9 | Good | 99.0 | 34346 |
NBI report | QUISENBERRY RD | COON CR | S 11 T 45 N R 22 W | Steel Stringer/Multi-beam or girder | -- | 2013 | -- | 72.5 | 74.5 | Good | 89.9 | 28940 |
NBI report | MAIN ST | COON CR | S 35 T 46 N R 22 W | Prestressed Stringer/Multi-beam or girder | -- | 2015 | -- | 61.4 | 64.0 | Good | 89.9 | 35081 |
NBI report | MCGEE RD | MCGEE BR | S 33 T 45 N R 20 W | Metal Culvert | -- | 2015 | -- | 33.1 | 40.0 | Good | 100.0 | 35189 |
NBI report | SCHONDELMAIER RD | TRIB TO GRASSY CR | S 27 T 48 N R 22 W | Metal Culvert | -- | 2016 | -- | 20.3 | 24.6 | Good | 100.0 | 35188 |
NBI report | STOKLEY RD | TRIB TO ELK CR | S 20 T 47 N R 23 W | Prestressed Box beam or girders - Multiple | -- | 2016 | -- | 47.6 | 49.9 | Good | 100.0 | 35350 |
NBI report | CHAMBERLIN RD | TRIB OF HEATHS CR | S 2 T 47 N R 22 W | Metal Culvert | -- | 2017 | -- | 24.0 | 24.0 | Good | 100.0 | 35689 |
NBI report | MAIN ST | ELK CR | S 36 T 46 N R 23 W | Steel Stringer/Multi-beam or girder | -- | 2017 | -- | 60.4 | 63.0 | Good | 99.0 | 35425 |
NBI report | MAIN ST | TRIB ELK BR | S 31 T 46 N R 22 W | Metal Culvert | -- | 2017 | -- | 22.6 | 22.6 | Good | 99.0 | 35860 |
NBI report | RT M S | FLAT CR | S 24 T 45 N R 21 W | Prestressed Tee beam (3 spans) | New | 2017 | -- | 118.1 | 309.7 | Good | 79.6 | 35488 |
NBI report | BLUEBIRD HOLLOW RD | TRIB OF WILLOW BR | S 21 T 47 N R 20 W | Metal Culvert | -- | 2018 | -- | 21.0 | 21.0 | Good | 87.5 | 35861 |