Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | BNSF RR | BNSF RR 089-037-N | EAST ELM ST. @ BNRR | Steel Stringer/Multi-beam or girder | -- | 1921 | -- | 24.0 | -- | -- | -- | U223024210 |
NBI report | US30/US385 | LODGEPOLE CREEK TRIB | 4E SIDNEY | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1925 | 1989 | 12.1 | 24.0 | Fair | 81.4 | S030 06360 |
NBI report | US30/US385 | STREAM | 2E SIDNEY | Concrete Culvert (2 spans) | -- | 1927 | 1968 | 12.1 | 25.9 | Good | 65.2 | S030 06127 |
NBI report | US30/US385 | STREAM | 8W LODGEPOLE | Concrete Culvert (2 spans) | -- | 1932 | 1968 | 9.8 | 22.0 | Good | 76.0 | S030 06939 |
NBI report | US30/US385 | STREAM | 3W LODGEPOLE | Concrete Culvert (2 spans) | -- | 1932 | 1968 | 12.1 | 25.9 | Good | 77.0 | S030 07378 |
NBI report | US30/US385 | STREAM | 5E SIDNEY | Concrete Culvert (9 spans) | -- | 1932 | 1974 | 12.1 | 118.1 | Fair | 56.8 | S030 06508 |
NBI report | US30/US385 | STREAM | 4W LODGEPOLE | Concrete Slab (3 spans) | -- | 1932 | 1974 | 16.1 | 49.9 | Fair | 53.3 | S030 07275 |
NBI report | US30/US385 | STREAM | 7E SIDNEY | Concrete Culvert (2 spans) | -- | 1932 | 2004 | 9.8 | 22.0 | Good | 76.5 | S030 06644 |
NBI report | CO RD 103 MI 10338 | DRY WASH | 1.5E 6.7N OF BROWNSON | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1935 | -- | 24.9 | 50.9 | Fair | 57.3 | C001743105P |
NBI report | CO RD 143 MI 14322 | LODGEPOLE CREEK | 2W LODGEPOLE | Concrete Channel beam | -- | 1935 | -- | 27.9 | 28.9 | Fair | 96.9 | C001717305 |
NBI report | CO RD 34 MI 34107 | STREAM | 5S 2W GURLEY | Wood Stringer/Multi-beam or girder | -- | 1935 | -- | 25.9 | 27.9 | Fair | 57.2 | C001722810P |
NBI report | UPRR | UPRR 817-639-R | .2W POTTER | Steel Girder and floorbeam system | -- | 1935 | -- | 47.9 | -- | -- | -- | C001710505P |
NBI report | US385 | LODGEPOLE TRIB | 5N SIDNEY | Concrete Culvert (2 spans) | -- | 1937 | 1979 | 9.8 | 22.0 | Good | 78.3 | S385 03875 |
NBI report | US385 | RUSH CREEK TRIBUTARY | 3N GURLEY | Concrete Culvert (2 spans) | -- | 1938 | 1993 | 9.8 | 21.0 | Good | 80.6 | S385 04886 |
NBI report | N19 | STREAM | 2N LORENZO | Concrete Culvert (3 spans) | -- | 1939 | 1993 | 7.9 | 28.9 | Good | 79.5 | S019 00477 |
NBI report | N19 | STREAM | 2S LORENZO | Concrete Culvert (3 spans) | -- | 1940 | 1993 | 7.9 | 24.9 | Good | 78.7 | S019 00187 |
NBI report | N19 | STREAM | 1S LORENZO | Concrete Culvert (2 spans) | -- | 1940 | 1993 | 9.8 | 21.0 | Good | 78.7 | S019 00284 |
NBI report | US30 | STREAM | 4E POTTER | Concrete Culvert (2 spans) | -- | 1944 | -- | 12.1 | 25.9 | Good | 76.9 | S030 04410 |
NBI report | US30 | STREAM | 5E POTTER | Concrete Culvert (3 spans) | -- | 1944 | -- | 7.9 | 25.9 | Good | 76.9 | S030 04505 |
NBI report | US30 | STREAM | 7E POTTER | Concrete Culvert (4 spans) | -- | 1944 | -- | 12.1 | 51.8 | Fair | 75.7 | S030 04705 |
NBI report | US30 | STREAM | 4W SIDNEY | Concrete Culvert (3 spans) | -- | 1944 | 1992 | 7.9 | 24.9 | Good | 84.4 | S030 05445 |
NBI report | US30 | STREAM | IN POTTER | Concrete Culvert (2 spans) | -- | 1944 | 1999 | 9.8 | 22.0 | Good | 75.3 | S030 04044 |
NBI report | US30 | LODGEPOLE CREEK TRIB | 2E POTTER | Concrete Slab (5 spans) | -- | 1944 | 1999 | 33.1 | 152.9 | Fair | 88.3 | S030 04184 |
NBI report | US30 | STREAM | 8W SIDNEY | Concrete Culvert (3 spans) | -- | 1944 | 1999 | 9.8 | 33.1 | Fair | 71.5 | S030 05011 |
NBI report | CO RD 77 MI 7736 | DRY WASH | JCT US30/L-17B 2.6N | Concrete Culvert (5 spans) | -- | 1945 | -- | 12.1 | 64.0 | Fair | 71.9 | C001720715 |
NBI report | CO RD 77 MI 7744 | STREAM | JCT US30/L-17B 6.8N | Concrete Culvert (4 spans) | -- | 1945 | -- | 9.8 | 44.0 | Fair | 79.3 | C001720720 |
NBI report | CO RD 46 MI 46109 | RUSH CREEK | WJCT US385/US30 12N 2.5W | Concrete Culvert (3 spans) | -- | 1946 | -- | 12.1 | 43.0 | Good | 72.6 | C001701805 |
NBI report | CO RD 139 MI 13938 | RUSH CREEK | JCT US30/L-17E 2E 8.3N | Concrete Culvert (5 spans) | -- | 1956 | -- | 12.1 | 77.1 | Good | 80.1 | C001716915 |
NBI report Bridgehunter | UPRR | UPRR 817-833-J | SIDNEY 13TH @ HICKORY | Steel Stringer/Multi-beam or girder | -- | 1956 | -- | 67.9 | -- | -- | -- | U2230K4110 |
NBI report | CO RD 113 MI 11314 | DRY WASH | JCT I80/L-17J 1W 1.7S | Concrete Culvert (2 spans) | -- | 1964 | -- | 12.1 | 25.9 | Fair | 80.3 | C001714305 |
NBI report | CO RD 121 MI 12102 | STREAM | 3.5E 9.5S SIDNEY | Concrete Culvert (2 spans) | -- | 1964 | -- | 9.8 | 22.0 | Good | 84.3 | C001705101 |
NBI report | CO RD 131 MI 13136 | STREAM | 2W 6.5N SUNOL | Concrete Culvert (5 spans) | -- | 1964 | -- | 9.8 | 54.1 | Good | 85.6 | C001726117 |
NBI report | CO RD 139 MI 13914 | COW CREEK | 2E 3S SUNOL | Concrete Slab (3 spans) | -- | 1964 | -- | 28.9 | 75.1 | Good | 88.8 | C001716903 |
NBI report | CO RD 36 MI 36119 | STREAM | 7N 3E SIDNEY | Concrete Culvert (2 spans) | -- | 1964 | -- | 9.8 | 22.0 | Good | 85.7 | C001732808 |
NBI report | CO RD 36 MI 36119 | STREAM | 7N 4E SIDNEY | Concrete Culvert (2 spans) | -- | 1964 | -- | 12.1 | 25.9 | Good | 84.7 | C001732810 |
NBI report | CO RD 46 MI 46115 | DRY WASH | WJCT US385/US30 12N .4E | Concrete Culvert (3 spans) | -- | 1964 | -- | 9.8 | 33.1 | Good | 83.4 | C001701810 |
NBI report | CO RD 46 MI 46123 | STREAM | WJCT US385/US30 12N 3.9E | Concrete Culvert (3 spans) | -- | 1964 | -- | 7.9 | 26.9 | Fair | 85.1 | C001701815 |
NBI report | CO RD 46 MI 4681 | STREAM | JCT US30/L-17B 7.5N 2.4E | Concrete Culvert (2 spans) | -- | 1964 | -- | 9.8 | 22.0 | Fair | 85.5 | C001701803 |
NBI report | CO RD 50 MI 50109 | STREAM | 2N 1.5W GURLEY | Concrete Culvert (2 spans) | -- | 1964 | -- | 9.8 | 22.0 | Good | 84.6 | C001701410 |
NBI report | CO RD 50 MI 5099 | RUSH CREEK | 2N 6W GURLEY | Concrete Culvert (5 spans) | -- | 1964 | -- | 9.8 | 54.1 | Good | 85.6 | C001701405 |
NBI report | CO RD 79 MI 7908 | SIDNEY DRAW | .5E 11S POTTER | Concrete Culvert (4 spans) | -- | 1964 | -- | 9.8 | 45.9 | Fair | 83.4 | C001700905 |
NBI report | CO RD 87 MI 8710 | SIDNEY DRAW | 4.5E 9.5S POTTER | Concrete Culvert (4 spans) | -- | 1964 | -- | 12.1 | 51.8 | Good | 79.9 | C001711705 |
NBI report | CO RD 87 MI 8728 | LODGEPOLE CREEK | 4.5E POTTER | Concrete Slab (4 spans) | -- | 1964 | -- | 43.0 | 151.9 | Good | 86.9 | C001711710 |
NBI report | CO RD 99 MI 9924 | LODGEPOLE CREEK | JCT US30/L-17C .6E .8S | Concrete Slab (3 spans) | -- | 1964 | -- | 48.9 | 123.0 | Fair | 95.8 | C001712905 |
NBI report | CO RD 99 MI 9936 | DRY WASH | JCT US30/L-17C .6E 5.3N | Concrete Culvert (3 spans) | -- | 1964 | -- | 12.1 | 38.1 | Good | 85.0 | C001712910 |
NBI report | CO RD 99 MI 9938 | DRY WASH | JCT US30/L-17C .6E 5.9N | Concrete Culvert (3 spans) | -- | 1964 | -- | 12.1 | 38.1 | Good | 84.0 | C001712915 |
NBI report | CORD34 MI 34137 | STREAM | 4.4W 5.5N LODGEPOLE | Concrete Culvert (4 spans) | -- | 1964 | -- | 9.8 | 44.0 | Good | 84.8 | C001743005 |
NBI report | CO RD 46 MI 46129 | DRY WASH | WJCT US385/US30 12N 6.7E | Concrete Culvert (4 spans) | -- | 1964 | 1989 | 5.9 | 25.9 | Good | 85.0 | C001701820 |
NBI report | CO RD 8 MI 877 | SIDNEY DRAW | 11.5S .2E OF POTTER | Concrete Culvert (4 spans) | -- | 1966 | -- | 9.8 | 47.9 | Good | 80.0 | C001705610 |
NBI report | CO RD 99 MI 9942 | STREAM | JCT US30/L-17C .6E 8.2N | Concrete Culvert (3 spans) | -- | 1966 | -- | 9.8 | 32.2 | Good | 87.7 | C001712920 |
NBI report | CO RD 42 MI 4293 | STREAM | 7N 2.3W BROWNSON | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1968 | 1989 | 15.1 | 30.8 | Fair | 49.7 | C001702205 |
NBI report | CO RD 111 MI 11106 | COW CREEK | 7S SIDNEY | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1969 | -- | 15.1 | 30.8 | Fair | 53.0 | C001704103 |
NBI report | CO RD 131 MI 13142 | RUSH CREEK | 9E 1S GURLEY | Concrete Culvert (4 spans) | -- | 1971 | -- | 9.8 | 43.0 | Good | 86.7 | C001726120 |
NBI report | COUNTY HIGHWAY | I80 | 2E SUNOL INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 87.9 | 274.9 | Good | 97.3 | S080 07164 |
NBI report | COUNTY HIGHWAY | I80 | 3W LODGEPOLE INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 87.9 | 274.9 | Good | 96.9 | S080 07365 |
NBI report | CO RD 93 MI 9316 | NORTH SIDNEY DRAW | 8.8W 1S SIDNEY | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1971 | 1985 | 24.0 | 49.9 | Good | 89.6 | C001722305 |
NBI report | L17E SUNOL CNLK | I80 | SUNOL INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 2006 | 88.9 | 275.9 | Good | 100.0 | S080 06963 |
NBI report | L17E SUNOL CNLK | LODGEPOLE CREEK | 1S SUNOL | Prestressed Tee beam (3 spans) | -- | 1971 | 2007 | 41.0 | 102.0 | Good | 99.8 | SL17E00216 |
NBI report | L17E SUNOL CNLK | STREAM | 0S SUNOL | Prestressed Tee beam | -- | 1971 | 2007 | 29.9 | 30.8 | Fair | 99.8 | SL17E00286 |
NBI report | L17F LODGPOLE CNLK | LODGEPOLE CREEK | 1S LODGEPOLE | Prestressed Tee beam (3 spans) | -- | 1971 | 2008 | 40.0 | 122.1 | Fair | 95.8 | SL17F00179 |
NBI report | L17E SUNOL CNLK | STREAM | 1S SUNOL | Concrete Culvert (2 spans) | -- | 1971 | 2013 | 9.8 | 22.0 | Good | 99.8 | SL17E00259 |
NBI report | I80 | L17F LODGEPOLE CNLK | LODGEPOLE INTRCHG | Prestressed Tee beam (3 spans) | -- | 1971 | 2016 | 57.1 | 149.0 | Good | 97.0 | S080 07661R |
NBI report | CO RD 125 MI 12514 | COW CREEK | JCT I80/L-17E 5W 1.3S | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1972 | 1984 | 29.9 | 60.0 | Good | 92.1 | C001715505 |
NBI report | CO RD 135 MI 13514 | COW CREEK | JCT I80/L-17E .5S | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1972 | 1984 | 29.9 | 60.0 | Good | 93.6 | C001716505 |
NBI report | CO RD 83 MI 8340 | STREAM | 4.5N 3E OF POTTER | Steel Stringer/Multi-beam or girder | -- | 1972 | 1985 | 27.9 | 29.9 | Good | 96.8 | C001731305 |
NBI report | CO RD 83 MI 8344 | DRY WASH | 2.5E 4.7N POTTER | Steel Stringer/Multi-beam or girder | -- | 1972 | 1985 | 27.9 | 29.9 | Good | 95.4 | C001731310 |
NBI report | COUNTY HIGHWAY | I80 | 1E KIMBALL/CHEYENNE LN | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1973 | -- | 95.1 | 295.9 | Good | 85.2 | S080 03683 |
NBI report | COUNTY HIGHWAY | I80 | 2W SUNOL INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1973 | -- | 87.9 | 274.9 | Fair | 96.9 | S080 06763 |
NBI report | EB-I80 ACCESS RAMP | STREAM | WEST SIDNEY INTRCHG | Concrete Culvert (2 spans) | -- | 1973 | -- | 9.8 | 22.0 | Good | 100.0 | S080 05553R |
NBI report | RD 125, FAS 1145 | I80 | 5E E SIDNEY INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1973 | -- | 87.9 | 274.9 | Fair | 96.5 | S080 06462 |
NBI report | WB-I80 EXIT RAMP | STREAM | WEST SIDNEY INTRCHG | Concrete Culvert (2 spans) | -- | 1973 | -- | 9.8 | 22.0 | Good | 100.0 | S080 05545L |
NBI report | CO RD 95 MI 9542 | STREAM | 8.4E 5.3N POTTER | Steel Stringer/Multi-beam or girder | -- | 1973 | 1985 | 27.9 | 29.9 | Good | 96.9 | C001742510 |
NBI report | CO RD 107 MI 10746 | RUSH CREEK | 3W GURLEY | Concrete Culvert (3 spans) | -- | 1974 | -- | 9.8 | 33.1 | Good | 88.6 | C001753725 |
NBI report | CO RD 111 MI 11136 | STREAM | 1W 5S GURLEY | Concrete Culvert (3 spans) | -- | 1974 | -- | 12.1 | 39.0 | Good | 88.6 | C001724103 |
NBI report | CO RD 111 MI 11138 | STREAM | 1W 3S GURLEY | Concrete Culvert (2 spans) | -- | 1974 | -- | 9.8 | 22.0 | Good | 85.6 | C001724104 |
NBI report | CO RD 125 MI 12520 | LODGEPOLE CREEK | JCT I80/L-17E 5W 2.3N | Concrete Culvert (3 spans) | -- | 1974 | -- | 12.1 | 39.0 | Good | 85.4 | C001715510 |
NBI report | CO RD 129 MI 12904 | COTTONWOOD CREEK | 3.5W 8S SUNOL | Concrete Culvert (2 spans) | -- | 1974 | -- | 9.8 | 22.0 | Good | 88.4 | C001705906 |
NBI report | COLL 7143 | I80 | 5E POTTER INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 87.9 | 272.0 | Good | 96.1 | S080 04396 |
NBI report | COUNTY HIGHWAY | I80 | 3E POTTER INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 87.9 | 284.1 | Good | 90.7 | S080 04193 |
NBI report | I80 | STREAM | 5E POTTER INTRCHG | Concrete Culvert (2 spans) | -- | 1974 | -- | 9.8 | 22.0 | Good | 76.0 | S080 04376 |
NBI report | I80 | STREAM | 2W BROWNSON INTRCHG | Concrete Culvert (3 spans) | -- | 1974 | -- | 7.9 | 26.9 | Good | 76.0 | S080 04459 |
NBI report | N19 | I80 | WEST SIDNEY INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1974 | -- | 98.1 | 305.1 | Good | 99.4 | S080 05537 |
NBI report | I80 | FAS 1115 | 2E BROWNSON INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 51.8 | 99.1 | Fair | 90.5 | S080 05035L |
NBI report | I80 | FAS 1115 | 2E BROWNSON INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 51.8 | 99.1 | Fair | 90.5 | S080 05035R |
NBI report | I80 | COLL 7138 | 1W WEST SIDNEY INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 51.8 | 115.2 | Good | 87.3 | S080 05420L |
NBI report | I80 | COLL 7138 | 1W WEST SIDNEY INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 51.8 | 115.2 | Good | 87.5 | S080 05420R |
NBI report | I80 | SIDNEY DRAW | 1W WEST SIDNEY INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 47.9 | 122.1 | Good | 88.8 | S080 05466L |
NBI report | I80 | SIDNEY DRAW | 1W WEST SIDNEY INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2000 | 47.9 | 122.1 | Good | 88.8 | S080 05466R |
NBI report | I80 | BNSF RR 089-028-P | 1E WEST SIDNEY INTRCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | 2000 | 49.9 | 128.0 | Good | 90.8 | S080 05620L |
NBI report | I80 | BNSF RR 089-028-P | 1E WEST SIDNEY INTRCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | 2000 | 49.9 | 128.0 | Good | 90.8 | S080 05620R |
NBI report | I80 | FAU 6350 | 1.3W E. SIDNEY INTERCHNG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1974 | 2000 | 103.0 | 204.1 | Good | 90.8 | S080 05864L |
NBI report | I80 | FAS 1122 | 1.3W E SIDNEY INTERCHNG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1974 | 2000 | 103.0 | 204.1 | Good | 90.8 | S080 05864R |
NBI report | I80 | L17J EAST SIDNEY CNLK | EAST SIDNEY INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1974 | 2000 | 90.9 | 184.1 | Good | 90.8 | S080 05992R |
NBI report | L17C BROWNSON CNLK | I80 | BROWNSON INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1974 | 2000 | 101.1 | 319.9 | Good | 99.6 | S080 04882 |
NBI report | L17C BROWNSON CNLK | LODGEPOLE CREEK | 3S BROWNSON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1974 | 2000 | 79.1 | 242.1 | Good | 89.7 | SL17C00036 |
NBI report | I80 | L17B POTTER CNLK | POTTER INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2004 | 51.8 | 99.1 | Fair | 77.2 | S080 03896L |
NBI report | I80 | L17B POTTER CNLK | POTTER INTRCHG | Concrete Slab (3 spans) | -- | 1974 | 2004 | 51.8 | 99.1 | Poor | 56.4 | S080 03896R |
NBI report | N19 | SIDNEY DRAW | 3W 1S SIDNEY | Concrete Slab (3 spans) | -- | 1974 | 2007 | 20.0 | 51.8 | Good | 98.8 | S019 01013 |
NBI report | N19 | LODGEPOLE CREEK | 3W 1S SIDNEY | Concrete Slab (3 spans) | -- | 1974 | 2007 | 47.9 | 122.1 | Good | 98.2 | S019 01073 |
NBI report | L17B POTTER CNLK | LODGEPOLE CREEK | 1S POTTER | Prestressed Tee beam (3 spans) | -- | 1974 | 2015 | 40.0 | 122.1 | Good | 91.3 | SL17B00047 |
NBI report | I80 | STREAM | WEST SIDNEY INTRCHG | Concrete Culvert (2 spans) | -- | 1974 | 2016 | 9.8 | 22.0 | Good | 76.5 | S080 05549 |
NBI report | I80 | L17J EAST SIDNEY CNLK | EAST SIDNEY INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1974 | 2016 | 90.9 | 184.1 | Good | 90.8 | S080 05992L |
NBI report | CO RD 125 MI 12540 | RUSH CREEK | JCT I80/L-17E 5W 11.7N | Concrete Culvert (4 spans) | -- | 1975 | -- | 9.8 | 43.0 | Good | 87.7 | C001715515 |
NBI report | CO RD 16 MI 16119 | STREAM | 1.5S 3.7E SIDNEY | Concrete Culvert (3 spans) | -- | 1975 | -- | 12.1 | 38.1 | Good | 88.5 | C001734805 |
NBI report | CO RD 18 MI 18101 | SIDNEY DRAW | 4.7W 1S SIDNEY | Concrete Culvert (4 spans) | -- | 1975 | -- | 9.8 | 43.0 | Good | 85.2 | C001714610 |
NBI report | CO RD 8 MI 8113 | COW CREEK | JCT I80/L-17J 1.3W 4.6S | Concrete Culvert (2 spans) | -- | 1975 | -- | 9.8 | 22.0 | Good | 85.2 | C001705615 |
NBI report | CO RD 99 MI 9916 | SIDNEY DRAW | JCT I80/L-17C 4.8S | Concrete Culvert (4 spans) | -- | 1975 | -- | 9.8 | 43.0 | Good | 84.9 | C001712903 |
NBI report | CO RD 139 MI 13932 | RUSH CREEK | JCT I80/L-17E 2E 8.4N | Concrete Culvert (4 spans) | -- | 1976 | -- | 9.8 | 43.0 | Good | 88.5 | C001716913 |
NBI report | L17J SIDNEY CNLK | LODGEPOLE CREEK | 1E SIDNEY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1976 | -- | 56.1 | 144.0 | Fair | 86.3 | SL17J00195 |
NBI report | US30 | UPRR | 1E SIDNEY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1976 | 2009 | 61.0 | 201.1 | Good | 89.5 | S030 06096 |
NBI report | CO RD 105 MI 10518 | SIDNEY DRAW | 2.8W SIDNEY | Concrete Culvert (4 spans) | -- | 1977 | -- | 9.8 | 43.0 | Good | 84.2 | C001723505 |
NBI report | CO RD 131 MI 13122 | LODGEPOLE CREEK | 2W SUNOL | Concrete Culvert (4 spans) | -- | 1977 | -- | 9.8 | 44.0 | Good | 87.8 | C001716110 |
NBI report | CO RD 20 MI 20105 | SIDNEY DRAW | 2W SIDNEY | Concrete Culvert (4 spans) | -- | 1977 | -- | 9.8 | 47.9 | Good | 85.5 | C001714405 |
NBI report | CO RD 36 MI 36113 | STREAM | 7N .4E SIDNEY | Concrete Culvert (3 spans) | -- | 1977 | -- | 9.8 | 33.1 | Good | 85.7 | C001732805 |
NBI report | CO RD 38 MI 38145 | RUSH CREEK | 7.5N LODGEPOLE | Concrete Culvert (4 spans) | -- | 1977 | -- | 9.8 | 43.0 | Fair | 88.3 | C001732605 |
NBI report | CO RD 111 MI 11144 | RUSH CREEK | 1W .1S GURLEY | Concrete Culvert (3 spans) | -- | 1978 | -- | 9.8 | 36.1 | Good | 86.6 | C001724105 |
NBI report | US385 | LODGEPOLE TRIB | 4S GURLEY | Concrete Culvert (2 spans) | -- | 1979 | -- | 9.8 | 21.0 | Good | 93.4 | S385 04169 |
NBI report | US385 | RUSH CREEK | 1S GURLEY | Concrete Culvert (3 spans) | -- | 1979 | -- | 12.1 | 38.1 | Good | 79.9 | S385 04504 |
NBI report | US385 | RUSH CREEK TRIBUTARY | 1S DALTON | Concrete Culvert (3 spans) | -- | 1979 | -- | 9.8 | 32.2 | Good | 83.5 | S385 05153 |
NBI report | CO RD 32 MI 32117 | STREAM | WJCT US30/US385 1.4E 5N | Concrete Culvert (4 spans) | -- | 1980 | -- | 9.8 | 43.0 | Good | 88.2 | C001703205 |
NBI report | CO RD 77 MI 7716 | STREAM | 6.6S POTTER | Concrete Culvert (4 spans) | -- | 1980 | -- | 9.8 | 42.0 | Good | 83.4 | C001700705 |
NBI report | CO RD 149 MI 14916 | COW CREEK | JCT I80/L-17F .5S | Concrete Slab (3 spans) | -- | 1981 | -- | 27.9 | 71.9 | Good | 82.2 | C001717905 |
NBI report | CO RD 48 MI 4871 | STREAM | JCT US30/L17B 8.5N 2.5W | Concrete Culvert (2 spans) | -- | 1981 | -- | 9.8 | 21.0 | Good | 84.4 | C001701605 |
NBI report | CO RD 75 MI 7506 | SIDNEY DRAW | 1W 12.5S POTTER | Steel Culvert (4 spans) | -- | 1981 | -- | 5.9 | 29.9 | Good | 90.9 | C001700505 |
NBI report | CO RD 32 MI 3279 | STREAM | 1.3E POTTER | Concrete Culvert (4 spans) | -- | 1982 | -- | 12.1 | 49.9 | Good | 88.7 | C001703210P |
NBI report | CO RD 44 MI 44111 | RUSH CREEK | .6S .5W GURLEY | Concrete Culvert (3 spans) | -- | 1983 | -- | 12.1 | 38.1 | Good | 85.7 | C001702005 |
NBI report | CO RD 6 MI 6109 | COW CREEK | 1W 6S SIDNEY | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 23.0 | 25.9 | Good | 80.7 | C001705805 |
NBI report | CO RD 89 MI 8940 | STREAM | 5.4E 4.5N POTTER | Concrete Culvert (3 spans) | -- | 1983 | -- | 8.9 | 28.9 | Good | 86.4 | C001731905 |
NBI report | CO RD 16 MI 16129 | COW CREEK | 3.5S 2.5W OF SUNOL | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 27.9 | 29.9 | Good | 94.6 | C001734815 |
NBI report | CO RD 48 MI 48103 | RUSH CREEK | 1N 4.25W OF GURLEY | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 27.9 | 29.9 | Good | 96.8 | C001701615 |
NBI report | CO RD 73 MI 7332 | LODGEPOLE CREEK | 2W POTTER | Concrete Slab (3 spans) | -- | 1986 | -- | 42.0 | 105.0 | Good | 93.8 | C001720305 |
NBI report | BNSF RR | BNSF RR 089-035-A | IN SIDNEY | Steel Stringer/Multi-beam or girder | -- | 1987 | -- | 10.5 | -- | -- | -- | S030 05983 |
NBI report | CO RD 83 MI 8328 | LODGEPOLE CREEK | 3E POTTER | Prestressed Tee beam (2 spans) | -- | 1987 | -- | 40.0 | 82.0 | Good | 96.6 | C001721303 |
NBI report | CO RD 73 MI 7322 | NORTH SIDNEY DRAW | 4S 2W OF POTTER | Concrete Slab (3 spans) | -- | 1988 | -- | 38.1 | 97.1 | Good | 89.6 | C001704005P |
NBI report | US30 | STREAM | IN SIDNEY | Concrete Culvert (2 spans) | -- | 1988 | -- | 6.9 | 20.7 | Good | 84.9 | S030 05984 |
NBI report | US385 | RUSH CREEK TRIBUTARY | 2N GURLEY | Concrete Culvert (3 spans) | -- | 1989 | 1993 | 7.9 | 26.9 | Good | 80.6 | S385 04802 |
NBI report | CO RD 117 MI 11740 | RUSH CREEK | 2E 9.5N SIDNEY | Concrete Culvert (4 spans) | -- | 1992 | -- | 9.8 | 44.0 | Good | 87.9 | C001734710 |
NBI report | CO RD 121 MI 12140 | RUSH CREEK | 4E 2.2S OF GURLEY | Concrete Culvert (4 spans) | -- | 1992 | -- | 9.8 | 42.0 | Good | 87.6 | C001735105 |
NBI report | US30 | STREAM | 1W SIDNEY | Concrete Culvert (4 spans) | -- | 1992 | -- | 12.1 | 49.9 | Good | 95.3 | S030 05806 |
NBI report | CO RD 135 MI 13506 | COTTONWOOD CREEK | .5W 8S OF SUNOL | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 25.9 | 29.9 | Good | 91.9 | C001706510 |
NBI report | 11TH AVE/FAU 6363 | LODGEPOLE CREEK | SIDNEY 11TH/LODGEPOLE CR | Concrete Slab (3 spans) | -- | 1996 | -- | 44.0 | 115.2 | Good | 79.3 | U223004103P |
NBI report | 13TH AVE/FAU 6361 | LODGEPOLE CREEK | SIDNEY 13TH/LODGEPOLE CR | Concrete Slab (3 spans) | -- | 1996 | -- | 43.0 | 113.9 | Good | 74.7 | U2230K4105 |
NBI report | CO RD 131 MI 13116 | COW CREEK | 3.4S 2W SUNOL | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 49.9 | 50.9 | Good | 96.6 | C001716105 |
NBI report | CO RD 99 MI 9950 | RUSH CREEK | JCT US30/L-17C .6E 12.2N | Steel Stringer/Multi-beam or girder | -- | 1996 | -- | 40.0 | 41.0 | Good | 86.1 | C001712925 |
NBI report | SIDNEY DRAW RD | LODGEPOLE CREEK | SIDNEY DRAW RD AND 19TH | Concrete Slab (3 spans) | -- | 1996 | -- | 44.9 | 119.1 | Good | 82.7 | U223014410 |
NBI report | CO RD 52 MI 5295 | RUSH CREEK | 3S 9W DALTON | Steel Stringer/Multi-beam or girder | -- | 1998 | -- | 35.1 | 36.1 | Good | 96.8 | C001701205 |
NBI report | FAS 1127 | US-30/UPRR 817-841-B | .5W BROWNSON | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1999 | -- | 161.1 | 324.2 | Good | 90.9 | C001712515P |
NBI report | US30 | LODGEPOLE CREEK | 1W POTTER | Prestressed Tee beam (3 spans) | -- | 1999 | -- | 58.1 | 153.9 | Good | 91.1 | S030 03981 |
NBI report | CO RD 129 MI 12902 | STREAM | 3.5W 8.7S SUNOL | Concrete Stringer/Multi-beam or girder | -- | 2002 | -- | 30.8 | 32.2 | Good | 93.5 | C001705905 |
NBI report | CO RD 95 MI 9552 | RUSH CREEK | 8.5E 10.3N POTTER | Concrete Stringer/Multi-beam or girder (2 spans) | -- | 2002 | -- | 24.9 | 49.9 | Good | 96.1 | C001742515 |
NBI report | COUNTY HIGHWAY | RUSH CREEK | 10N 8E POTTER | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 26.9 | 27.9 | Good | 89.7 | C001701200 |
NBI report | COUNTY HIGHWAY | DRY WASH | JCT 19A/RD113 1.5S 1.5E | Steel Culvert (3 spans) | -- | 2004 | -- | 5.9 | 23.0 | Good | 95.9 | C001732500 |
NBI report | US30/US385 | LODGEPOLE CREEK | 1W LODGEPOLE | Concrete Culvert (5 spans) | -- | 2012 | -- | 12.1 | 38.1 | Good | 97.2 | S030 07625 |
NBI report | CO RD 139 MI 13924 | DRY WASH | JCT I80/L-17E 2E 3.6N | Concrete Culvert (3 spans) | -- | 2013 | -- | 12.1 | 38.1 | Good | 97.3 | C001716910 |
NBI report | GREENWOOD ROAD | LODGEPOLE CREEK | GREENWOOD/LODGEPOLE CREEK | Concrete Culvert (4 spans) | -- | 2014 | -- | 9.8 | 42.0 | Good | 99.9 | U223024505 |
NBI report | CO RD 46-81E | SEASONAL DRAW | 7.5N, 3E POTTER | Steel Culvert (3 spans) | -- | 2016 | -- | 5.9 | 24.0 | Good | 99.5 | C001701804 |
NBI report | I80 | COW CREEK | 1E LODGEPOLE INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2016 | -- | 170.0 | 171.9 | Good | 90.8 | S080 07690R |
NBI report | CO RD 109 MI 10936 | STREAM | 4.3S & 2.2 W OF GURLEY | Concrete Culvert (2 spans) | -- | 2017 | -- | 12.1 | 25.3 | Good | 98.1 | C001743705P |
NBI report | FORT SIDNEY RD | LODGEPOLE CREEK | FORT SIDNEY RD @TOLEDO | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2017 | -- | 74.8 | 151.6 | Good | 99.6 | U223014310 |
NBI report | I80 | L17F LODGEPOLE CNLK | LODGEPOLE INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2017 | -- | 57.1 | 149.0 | Good | 97.0 | S080 07661L |
NBI report | I80 | COW CREEK | 1E LODGEPOLE INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2017 | -- | 170.0 | 171.9 | Good | 90.8 | S080 07690L |
NBI report | POLE CRK CROSSING | LODGEPOLE CREEK | SE CORNER OF SIDNEY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2017 | -- | 82.4 | 166.7 | Good | 95.0 | U223024410 |
NBI report | CO RD 139 MI 13922 | LODGEPOLE CREEK | 2E .1S OF SUNOL | Steel Stringer/Multi-beam or girder | -- | 2018 | -- | 27.9 | 29.9 | Good | 91.8 | C001716905 |