Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | UPRR | UPRR 816-817-W | OMAHA 20TH @ WOOLWORTH | Steel Stringer/Multi-beam or girder | -- | -- | -- | 32.2 | -- | -- | -- | U1825F5515 |
NBI report | BNSF RR | BNSF RR 073-051-L | OMAHA 60TH @ V | Steel Stringer/Multi-beam or girder | -- | 1904 | -- | 29.9 | -- | -- | -- | U182504705P |
NBI report | PAWNEE ROAD | STREAM | JCT N36/N133 1N 1E | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1907 | 1954 | 32.2 | 78.1 | Poor | 53.0 | C002800410 |
NBI report | 264TH STREET | RAWHIDE CREEK | 5N 1E OF VALLEY | Steel Girder and floorbeam system | -- | 1915 | -- | 40.0 | 42.0 | Fair | 36.3 | C002801525 |
NBI report | BNSF RR | BNSF RR 074-688-G | OMAHA 14TH @ MASON | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 44.0 | -- | -- | -- | U1825M5505 |
NBI report | ELK CITY DRIVE | STREAM | .5W ELK CITY | Steel Stringer/Multi-beam or girder | -- | 1920 | -- | 28.9 | 29.9 | Fair | 80.9 | C002810405P |
NBI report | 252ND RD | ELKHORN RIVER TRIB | 1.2W 2.2N OF WATERLOO | Steel Stringer/Multi-beam or girder | -- | 1926 | 1962 | 23.0 | 24.0 | Poor | 41.0 | C002801720 |
NBI report | 252ND ST;COLL 7947 | ROAD DITCH | 1W 1N OF WATERLOO | Steel Stringer/Multi-beam or girder | -- | 1926 | 1962 | 24.0 | 24.9 | Poor | 47.6 | C002801715 |
NBI report | 252ND STREET | STREAM | 1W OF WATERLOO | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 23.0 | 24.0 | Fair | 75.4 | C002801710 |
NBI report | 276TH STREET | STREAM | 4N OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 35.1 | 36.1 | Fair | 81.7 | C002811310 |
NBI report | COUNTRY ROAD | STREAM | .3M W OF 276TH STREET | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 23.0 | 24.0 | Fair | 82.2 | C002800205P |
NBI report | FORT STREET | STREAM | 201ST & FORT ST | Steel Stringer/Multi-beam or girder | -- | 1927 | -- | 21.0 | 22.0 | Fair | 56.1 | C002821405 |
NBI report | 288TH STREET | STREAM | 1W 3N VALLEY | Steel Stringer/Multi-beam or girder | -- | 1928 | -- | 29.9 | 32.2 | Fair | 49.9 | C002800605 |
NBI report | 264TH STREET | STREAM | 3.5N 1E OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 23.0 | 24.0 | Fair | 78.2 | C002801515 |
NBI report | 264TH STREET | STREAM | 4N 1E OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1929 | -- | 23.0 | 24.0 | Fair | 65.1 | C002801520 |
NBI report | 282ND STREET | STREAM | 4.7N OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1930 | -- | 28.9 | 29.9 | Fair | 93.0 | C002801105P |
NBI report Bridgehunter | DUTCH HALL ROAD | RAWHIDE CREEK | 5W OF N31/DODGE CNTY LINE | Steel Truss - Thru | -- | 1930 | -- | 40.0 | 41.0 | Fair | 25.2 | C002810210 |
NBI report | 264TH STREET | STREAM | 2N 1E OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1931 | -- | 32.2 | 33.1 | Fair | 64.8 | C002801510 |
NBI report Bridgehunter | 252ND STREET | STREAM | 4.5N 2E OF VALLEY | Steel Truss - Thru | -- | 1932 | -- | 61.0 | 62.0 | Poor | 29.0 | C002801735 |
NBI report | F ST/COUNTY RD 49 | STREAM | 4.5S .5W OF WATERLOO | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 25.9 | 26.9 | Fair | 94.9 | C002812605 |
NBI report | F ST; COUNTY RD 49 | STREAM | 4.5S .2W OF WATERLOO | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 33.1 | 34.1 | Fair | 92.9 | C002812610 |
NBI report | STATE STREET | STREAM | 1N 1.5E OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 23.0 | 24.0 | Fair | 78.8 | C002801005 |
NBI report | STATE STREET | STREAM | 1N 1.7E OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1932 | -- | 24.9 | 25.9 | Poor | 58.0 | C002801010 |
NBI report | US6 | LITTLE PAPILLION CREEK | 78TH @ DODGE OMAHA | Prestressed Tee beam (3 spans) | -- | 1933 | 2000 | 40.0 | 101.1 | Fair | 68.1 | S006 36742 |
NBI report Bridgehunter | US6 | SADDLE CREEK RD | DODGE @ SADDLE CR OMAHA | Concrete Frame | NR listed | 1934 | -- | 49.9 | 53.2 | Fair | 48.7 | S006 37025 |
NBI report | 126TH STREET | HELL CREEK | OMAHA 126TH @ PEDERSEN | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 25.9 | Good | 75.9 | U1825E3705 |
NBI report | 144TH STREET | STREAM | OMAHA 144TH @ FORT | Concrete Culvert (2 spans) | -- | 1935 | -- | 9.8 | 22.0 | Good | 83.0 | U182503512 |
NBI report | 144TH STREET | STREAM | OMAHA 144TH @ IDA | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 26.9 | Good | 85.2 | U182503513 |
NBI report Bridgehunter | 46TH STREET | STREAM | OMAHA 46TH @ U | Wood Stringer/Multi-beam or girder (3 spans) | -- | 1935 | -- | 19.0 | 50.9 | Fair | 49.8 | U1825B5105 |
NBI report | 90TH ST/FAU 5019 | STREAM | OMAHA 90TH @ HOLMES | Steel Culvert (2 spans) | -- | 1935 | -- | 11.2 | 24.9 | Fair | 92.2 | U1825G4305 |
NBI report | A STREET | HELL CREEK | OMAHA A @ PEDERSEN | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 25.9 | Good | 88.2 | U1825G3705 |
NBI report | BENNINGTON ROAD | STREAM | 3N .5W OF VALLEY | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 32.2 | 34.1 | Fair | 77.6 | C002801105 |
NBI report | BNSF RR | BNSF RR 074-683-X | OMAHA PIERCE @ 5TH | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 51.8 | -- | -- | -- | U1825A2205 |
NBI report | BNSF RR | BNSF RR 074-685-L | OMAHA 7TH @ PACIFIC | Concrete Slab | -- | 1935 | -- | 26.9 | -- | -- | -- | U1825B5702 |
NBI report | BNSF RR | BNSF RR 074-685-L | OMAHA 7TH @ MASON | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 25.9 | -- | -- | -- | U1825B5703 |
NBI report | BNSF RR | BNSF RR 074-719-D | OMAHA DAHLMAN @ H | Wood Stringer/Multi-beam or girder | -- | 1935 | -- | 20.0 | -- | -- | -- | U1825D5305 |
NBI report | BNSF RR | BNSF RR 074-706-C | OMAHA DAHLMAN @ F | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 86.0 | -- | -- | -- | U1825E5305 |
NBI report | BNSF RR | BNSF RR 074-679-H | OMAHA HICKORY @ 3RD | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 49.9 | -- | -- | -- | U1825F2205 |
NBI report | BNSF RR | BNSF RR 074-695-S | OMAHA 20TH @ CENTER | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 5.9 | -- | -- | -- | U1825F5510 |
NBI report | BNSF RR | BNSF RR 074-689-N | 13TH @ MASON | Steel Girder and floorbeam system | -- | 1935 | -- | 33.1 | -- | -- | -- | U1825M5520 |
NBI report | C STREET | HELL CREEK | OMAHA C @ PEDERSEN | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 25.9 | Good | 80.5 | U1825H3705 |
NBI report | J J PERSHING DR | PONCA CREEK | OMAHA JJ PERSHING @ PONCA | Concrete Culvert (2 spans) | -- | 1935 | -- | 14.1 | 29.9 | Fair | 71.3 | U182500430P |
NBI report | PEDESTRIAN OVRPASS | S 42ND ST | 42ND @ DOUGLAS | Steel Girder and floorbeam system | -- | 1935 | -- | 63.0 | -- | -- | -- | U1825G5120 |
NBI report | PEDESTRIAN OVRPASS | FARNAM ST | FARNAM @ 44TH | Steel Segmental box girder | -- | 1935 | -- | 84.0 | -- | -- | -- | U1825H2010 |
NBI report | PRATT STREET | COLE CREEK | OMAHA PRATT @ 70TH | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 27.9 | Good | 86.6 | U182531605 |
NBI report | SELDIN DRIVE | HELL CREEK | OMAHA SELDIN @ PEDERSEN | Concrete Culvert (2 spans) | -- | 1935 | -- | 12.1 | 25.9 | Good | 87.7 | U1825F3705 |
NBI report | UPRR | UPRR 816-827-C | OMAHA 60TH @ I80 | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 74.2 | -- | -- | -- | U182504910 |
NBI report | UPRR | UPRR | OMAHA 7TH @ MARCY | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 25.9 | -- | -- | -- | U1825B5704 |
NBI report | UPRR | UPRR 816-815-H | OMAHA 14TH @ MARCY | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 44.9 | -- | -- | -- | U1825M5510 |
NBI report | UPRR | UPRR 191-548-A | OMAHA 25TH @ JJ PERSHING | Steel Girder and floorbeam system | -- | 1935 | -- | 75.1 | -- | -- | -- | U1825M5515 |
NBI report | UPRR | UPRR 816-814-B | 13TH @ MARCY | Steel Stringer/Multi-beam or girder | -- | 1935 | -- | 33.1 | -- | -- | -- | U1825M5525 |
NBI report | AMES AVE/FAU 5080 | COLE CREEK | OMAHA AMES @ 66TH | Concrete Culvert (2 spans) | -- | 1935 | 1972 | 12.1 | 24.9 | Fair | 57.8 | U1825F1405 |
NBI report | 105TH ST/FAU 5013 | STREAM | OMAHA 105TH @ FRANCES | Concrete Culvert (2 spans) | -- | 1935 | 1988 | 12.1 | 25.9 | Fair | 82.9 | U1825F4105 |
NBI report | BURT STREET | COLE CREEK | OMAHA BURT @ 77TH | Prestressed Tee beam | -- | 1935 | 1998 | 32.2 | 32.2 | Good | 90.9 | U1825K4510 |
NBI report | 84TH ST/FAU 5023 | BIG PAPILLION CREEK | 84TH @ GROVER ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1935 | 2008 | 103.0 | 253.0 | Good | 65.9 | U182504515 |
NBI report | N31 | PARK/PAPIO/UP 816-853-S | IN ELKHORN | Steel Stringer/Multi-beam or girder (10 spans) | -- | 1938 | 1977 | 76.1 | 515.1 | Poor | 43.3 | S031 02440 |
NBI report | N133 | STREAM | IN OMAHA | Concrete Culvert (2 spans) | -- | 1939 | -- | 12.1 | 25.9 | Fair | 54.8 | S133 00155 |
NBI report | US275/N92 | BNSF RR 074-715-B | 36TH & L STREET OMAHA | Steel Girder and floorbeam system (10 spans) | -- | 1939 | 1977 | 67.9 | 631.9 | Fair | 60.1 | S275 18809 |
NBI report | N92 | STREAM | 3E YUTAN | Concrete Culvert (2 spans) | -- | 1942 | -- | 9.8 | 22.0 | Poor | 38.7 | S092 46425 |
NBI report | N36 | STREAM | 2W ELK CITY | Concrete Culvert (3 spans) | -- | 1943 | 1997 | 12.1 | 40.0 | Good | 69.7 | S036 00668 |
NBI report | N36 | ELKHORN RIVER | 2W ELK CITY | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1944 | 1997 | 103.0 | 515.1 | Good | 82.0 | S036 00657 |
NBI report Bridgehunter | Q ST/FAU 5026 | EBG AVE /UPRR 817-369R | OMAHA Q @ 26TH | Steel Girder and floorbeam system (11 spans) | -- | 1950 | 1979 | 100.1 | 854.0 | Poor | 5.0 | U182522840 |
NBI report Bridgehunter | I680 | MISSOURI RIVER | ECL OMAHA | Steel Truss - Thru (3 spans) | -- | 1952 | 1986 | 420.0 | 1603.1 | Fair | 46.7 | S680 01343R |
NBI report | 72ND ST/FAU 5037 | LITTLE PAPILLION CREEK | OMAHA 72ND @ PACIFIC | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1954 | 2000 | 55.1 | 124.0 | Fair | 77.9 | U182504725 |
NBI report Bridgehunter | N64 | 33RD ST | 33RD & CUMING OMAHA | Concrete Frame | -- | 1955 | -- | 42.0 | 44.0 | Fair | 47.0 | S064 07824 |
NBI report | N92 | PLATTE OVERFLOW | 5E YUTAN | Concrete Slab | -- | 1955 | -- | 36.1 | 38.1 | Fair | 73.0 | S092 46635 |
NBI report | US275 | ELKHORN RIVER TRIB | 4S WATERLOO | Concrete Slab (3 spans) | -- | 1955 | 1987 | 33.1 | 81.0 | Fair | 86.7 | S275 17085 |
NBI report | US275 | ELKHORN RIVER | 5W WCL OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1955 | 1987 | 149.9 | 438.0 | Good | 83.2 | S275 17144 |
NBI report | N31 | N BR PAPILLION CREEK | 5N ELKHORN | Concrete Culvert (2 spans) | -- | 1956 | 2014 | 12.1 | 25.9 | Fair | 75.3 | S031 02963 |
NBI report Bridgehunter | RAINWOOD ROAD | RAWHIDE CREEK | 2N 2.5E OF VALLEY | Steel Truss - Thru | -- | 1958 | -- | 40.0 | 42.0 | Poor | 37.5 | C002800810 |
NBI report | N38 | STREAM | W. CENTER RD. AT 108TH ST | Concrete Culvert (2 spans) | -- | 1958 | 1963 | 12.1 | 35.1 | Good | 57.8 | U182500385 |
NBI report | N36 | THOMAS CREEK | 3E BENNINGTON | Concrete Slab (3 spans) | -- | 1958 | 1979 | 51.8 | 113.9 | Fair | 83.3 | S036 01806 |
NBI report | US275/N92 | HELL CREEK | 1W L ST INTRCHG | Concrete Culvert (2 spans) | -- | 1958 | 2000 | 12.1 | 28.9 | Fair | 57.8 | S275 18139 |
NBI report | WB-US275/N92 | I80 | I & L ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | 1984 | 85.0 | 340.9 | Fair | 98.0 | S080 44508 |
NBI report | I ST/FAU 5028 | I80 | IN OMAHA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1959 | 1988 | 97.1 | 367.1 | Fair | 58.5 | S080 44537 |
NBI report | I80 | HELL CREEK | 1S L ST INTRCHG | Concrete Culvert (2 spans) | -- | 1959 | 1988 | 12.1 | 27.9 | Good | 57.8 | S080 44443 |
NBI report | Q ST/FAU 5026 | I80 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1959 | 1993 | 164.1 | 327.1 | Fair | 85.0 | S080 44459 |
NBI report | N31 | BIG PAPILLION CREEK TRIB | 7N ELKHORN | Concrete Slab (3 spans) | -- | 1959 | 1998 | 48.9 | 123.0 | Fair | 80.0 | S031 03175 |
NBI report | CITY STREET | BIG PAPILLION CREEK | 1W 680 ON OLD 6 OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2005 | 122.1 | 266.1 | Fair | 80.0 | U182536466 |
NBI report | EB-US275/N92 | I80 | I & L ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1959 | 2008 | 85.0 | 340.9 | Fair | 96.3 | S080 44507 |
NBI report | I680 | BIG PAPILLION CREEK | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1959 | 2013 | 120.1 | 323.2 | Fair | 85.0 | S680 00216 |
NBI report | 42ND ST/FAU 5057 | UPRR 191-593-U | OMAHA 42ND @ D | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 1995 | 60.0 | 167.0 | Fair | 69.3 | U1825G5105 |
NBI report | 42ND ST/FAU 5057 | UPRR 816-825-N | OMAHA 42ND @ I80 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1960 | 1995 | 74.2 | 213.9 | Fair | 54.2 | U1825G5110 |
NBI report | US 6 | I680 | DODGE ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1960 | 2003 | 130.9 | 251.0 | Good | 94.3 | S680 00302 |
NBI report | AK-SAR-BEN ACCESS | LITTLE PAPIO CREEK | WOOLWORTH AVE @ 69TH ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1961 | -- | 69.9 | 142.1 | Fair | 68.9 | U1825D2201 |
NBI report | N38 | ABANDONED UPRR | 38TH & CENTER OMAHA | Concrete Slab (3 spans) | -- | 1961 | -- | 48.9 | 128.0 | Good | 48.4 | U182500980 |
NBI report | PEDESTRIAN OVRPASS | S 42ND ST | OMAHA 42ND @ VINTON | Steel Truss - Thru | -- | 1961 | -- | 60.0 | -- | -- | -- | U1825G5115 |
NBI report | EB-I80 | 84TH ST/FAU 5023 | 84TH ST INTRCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1987 | 94.2 | 185.0 | Fair | 97.0 | S080 44827R |
NBI report | EB-I80 | BIG PAPIL CR/82ND ST& | OMAHA I80 @ 82ND ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1987 | 109.9 | 303.2 | Fair | 84.0 | S080 44846R |
NBI report | WB-I80 | 84TH ST/FAU 5023 | 84TH ST INTRCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1993 | 94.2 | 185.0 | Fair | 98.0 | S080 44827L |
NBI report | WB-I80 | BIG PAPIL CR/82ND AVE&ST | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1961 | 1993 | 109.9 | 303.2 | Fair | 84.0 | S080 44846L |
NBI report | EB-I80 | 72ND ST/FAU 5037 | 72ND ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1961 | 1994 | 56.1 | 191.9 | Good | 98.0 | S080 44927R |
NBI report | WB-I80 | 72ND ST/FAU 5037 | 72ND ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1961 | 1995 | 56.1 | 191.9 | Good | 97.0 | S080 44927L |
NBI report | 24TH ST/FAU 5083 | I80 | 24TH ST INTRCHG | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1962 | 1988 | 110.9 | 394.0 | Fair | 82.0 | S080 45337 |
NBI report | Q ST/FAU 5056 | HELL CREEK | 118TH @ Q ST | Concrete Culvert (2 spans) | -- | 1962 | 1988 | 12.1 | 25.9 | Good | 57.8 | U182502825 |
NBI report | I80/RMP 50/RMP 40 | UPRR | IN OMAHA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1962 | 1989 | 76.1 | 305.1 | Fair | 75.5 | S080 45252 |
NBI report | I480/US75 | ARBOR ST | IN OMAHA | Concrete Slab (3 spans) | -- | 1962 | 1991 | 57.1 | 151.9 | Good | 83.0 | S480 00062L |
NBI report | I480/US75 | ARBOR ST | IN OMAHA | Concrete Slab (3 spans) | -- | 1962 | 1991 | 57.1 | 151.9 | Good | 83.0 | S480 00062R |
NBI report | I480/US75 | N38 | N38 INTRCHG | Concrete Slab (4 spans) | -- | 1962 | 1991 | 60.0 | 173.9 | Good | 95.3 | S480 00088L |
NBI report | I480/US75 | N38 | N38 INTRCHG | Concrete Slab (4 spans) | -- | 1962 | 1991 | 60.0 | 173.9 | Good | 95.3 | S480 00088R |
NBI report | LEAVENWORTH ST/FAU | I480/US75 | LEAVENWORTH ST INTRCHG | Concrete Box beam or girders - Multiple (4 spans) | -- | 1962 | 1995 | 74.2 | 213.9 | Fair | 64.0 | S480 00180 |
NBI report | ST MARYS AVE | I480/US75 | IN OMAHA | Concrete Box beam or girders - Multiple (4 spans) | -- | 1962 | 1995 | 80.1 | 217.9 | Fair | 68.0 | S480 00188 |
NBI report | EB-I80 | 60TH ST/FAU 5043 | 60TH ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1962 | 1996 | 97.1 | 188.0 | Fair | 85.0 | S080 45028R |
NBI report | EB-I80 | 50TH ST/FAU 5053 | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 1996 | 62.0 | 184.1 | Fair | 81.0 | S080 45103R |
NBI report | US275/N92 | LITTLE PAPILLION CREEK | 1E RALSTON | Prestressed Tee beam (3 spans) | -- | 1962 | 1997 | 60.0 | 162.1 | Good | 85.0 | S275 18587 |
NBI report | WB-I80 | 60TH ST/FAU 5043 | 60TH ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1962 | 1997 | 97.1 | 188.0 | Fair | 85.0 | S080 45028L |
NBI report | WOOLWORTH AVE/FAU | I480/US75 | IN OMAHA | Concrete Box beam or girders - Multiple (4 spans) | -- | 1962 | 1998 | 74.2 | 240.2 | Fair | 71.5 | S480 00131 |
NBI report | US275/N92 | BIG PAPILLION CREEK | 1N RALSTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2001 | 109.9 | 279.9 | Good | 85.0 | S275 18484 |
NBI report | WB-I80 | 50TH ST/FAU 5053 | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2013 | 62.0 | 184.1 | Good | 81.0 | S080 45103L |
NBI report | WB-I80 | 42ND ST/FAU 5057 | 42ND ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1962 | 2013 | 65.9 | 204.1 | Good | 97.0 | S080 45180L |
NBI report | US275/N92 | 72ND STREET/FAU 5037 | 72ND & L ST INTRCHG | Concrete Slab (4 spans) | -- | 1962 | 2015 | 55.1 | 205.1 | Fair | 64.1 | S275 18525 |
NBI report | BNSF RR | BNSF RR | OMAHA 36TH @ I | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 38.1 | -- | -- | -- | U182505305 |
NBI report | BNSF RR | BNSF RR 074-712-F | OMAHA 36TH @ H | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 38.1 | -- | -- | -- | U182505310 |
NBI report | FARNAM ST/FAU 5052 | I480/US75 | IN OMAHA | Concrete Box beam or girders - Multiple (4 spans) | -- | 1963 | 1993 | 82.0 | 274.9 | Fair | 79.0 | S480 00216 |
NBI report | HARNEY ST/FAU 5050 | I480/US75 | HARNEY ST INTRCHG | Concrete Box beam or girders - Multiple (4 spans) | -- | 1963 | 1995 | 74.2 | 228.0 | Fair | 79.0 | S480 00209 |
NBI report | WESTERN AVE | LITTLE PAPILLION CREEK | OMAHA WESTERN @ 83RD | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 2004 | 71.9 | 144.0 | Fair | 75.2 | U1825H1805 |
NBI report | N38 | BIG PAPILLION CREEK | 0W 90TH ST OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 1986 | 120.1 | 305.1 | Fair | 49.8 | U182500522 |
NBI report | EB-US6/DOUGLAS ST | I480/US75 | IN OMAHA | Concrete Box beam or girders - Multiple (4 spans) | -- | 1964 | 1993 | 111.9 | 341.9 | Fair | 73.5 | S480 00224 |
NBI report | WB-US6/DODGE ST | I480/US75 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1964 | 1998 | 235.9 | 476.1 | Good | 55.5 | S480 00231 |
NBI report | Q ST/FAS 3795 | ELKHORN RIVER | WJCT US275/N92 2S .2W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1964 | 2000 | 129.9 | 351.1 | Fair | 82.8 | C002802810 |
NBI report | 50TH ST. | MILL CREEK | .2S N36 & 50TH ST. | Concrete Culvert (2 spans) | -- | 1965 | -- | 12.1 | 25.9 | Fair | 85.6 | U1825J4905 |
NBI report | 52ND AVE. | MILL CREEK | .2SW OF N36 & 52ND AVE. | Concrete Culvert (2 spans) | -- | 1965 | -- | 12.1 | 25.9 | Fair | 71.4 | U1825G4905 |
NBI report | ABANDONED UPRR | ABANDONED UPRR | OMAHA 60TH @ DAYTON | Steel Girder and floorbeam system | -- | 1965 | -- | 120.1 | -- | -- | -- | U182504905 |
NBI report | N50 | WEST PAPILLION CREEK | 1SW MILLARD | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1965 | 1989 | 86.0 | 226.1 | Good | 62.2 | S050 09127 |
NBI report | US6 | WESTROADS ACCESS ROAD | 99TH @ DODGE ST | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1965 | 2003 | 58.1 | 186.0 | Good | 79.0 | S006 36561 |
NBI report | PEDESTRIAN OVRPASS | W CENTER RD | 108TH & WEST CENTER | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 96.1 | -- | -- | -- | U182500384 |
NBI report | PEDESTRIAN OVRPASS | W CENTER RD | 98TH & WEST CENTER | Steel Stringer/Multi-beam or girder | -- | 1966 | -- | 111.9 | -- | -- | -- | U182500466 |
NBI report | 72ND ST/FAU 5037 | UPRR 816-828-J | OMAHA 72ND @ F | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1966 | 1979 | 50.9 | 253.0 | Fair | 50.3 | U182504710 |
NBI report | WB-N64 | BIG PAPILLION CREEK | 7E ELKHORN | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 1993 | 145.0 | 379.9 | Fair | 64.0 | S064 07011L |
NBI report | EB-US6 | 8TH ST/FAU 5052 | DOUGLAS ST OMAHA | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1966 | 1996 | 128.9 | 845.2 | Fair | 67.7 | S480 00378G |
NBI report | WB-US6 | FAU 5052 | DODGE ST OMAHA | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1966 | 1996 | 129.9 | 865.2 | Fair | 65.9 | S480 00378H |
NBI report | I480/US6 | UPRR/MO RIVER 816-759-D | ECL OMAHA | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1966 | 2001 | 424.9 | 1687.1 | Fair | 46.2 | S480 00413 |
NBI report | J J PERSHING DR | STREAM | OMAHA JJ PERSHING @ READ | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | 2004 | 71.9 | 167.0 | Good | 68.7 | U1825B5505 |
NBI report | L28K N64 TO N133 | LITTLE PAPILLION CREEK | 87TH & MILITARY OMAHA | Concrete Slab (3 spans) | -- | 1966 | 2014 | 48.9 | 122.1 | Fair | 79.6 | SL28K01578 |
NBI report | 72ND ST/FAU 5037 | COLE CREEK | OMAHA 72ND @ PINKNEY | Concrete Culvert (2 spans) | -- | 1968 | -- | 12.1 | 30.8 | Fair | 57.8 | U182504730 |
NBI report | PACIFIC ST/FAU5044 | BIG PAPILLION CREEK | PACIFIC @ 107TH ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 1976 | 100.1 | 241.2 | Good | 84.9 | U182522220 |
NBI report | I680 | FORT ST/FAU 5082 | FORT ST INTRCHG | Concrete Slab (4 spans) | -- | 1968 | 1994 | 44.0 | 149.9 | Fair | 71.3 | S680 00604L |
NBI report | I680 | FORT ST/FAU 5082 | FORT ST INTRCHG | Concrete Slab (4 spans) | -- | 1968 | 1994 | 44.0 | 149.9 | Fair | 71.3 | S680 00604R |
NBI report | MILITARY AVE | I680 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1968 | 1997 | 95.1 | 191.9 | Good | 73.6 | S680 00654 |
NBI report | CASS ST/FAU 5060 | LITTLE PAPILLION CREEK | OMAHA CASS @ 78TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1968 | 2007 | 63.0 | 142.1 | Good | 62.7 | U182512025 |
NBI report | US275/N92 | UPRR/STOCKYDS 817-393-V | 1W MISSOURI RIVER BRG | Steel Stringer/Multi-beam or girder (18 spans) | -- | 1968 | 2012 | 133.9 | 1242.2 | Good | 80.1 | S275 18888 |
NBI report | N64 | COLE CREEK | 75TH & MAPLE OMAHA | Concrete Culvert (2 spans) | -- | 1969 | -- | 12.1 | 26.9 | Fair | 55.8 | S064 07384 |
NBI report | US275 | US75 | KENNEDY EXP/L ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1969 | 1988 | 109.9 | 210.0 | Fair | 95.0 | S275 18910 |
NBI report | 72ND ST/FAU 5037 | I680 | 72ND ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1969 | 1997 | 95.1 | 316.9 | Good | 93.6 | S680 00986 |
NBI report | N64 | LITTLE PAPILLION CREEK | 10E ELKHORN | Concrete Slab (3 spans) | -- | 1969 | 2017 | 58.1 | 145.0 | Fair | 72.0 | S064 07280 |
NBI report | 276TH STREET | STREAM | 4N OF VALLEY | Concrete Culvert (2 spans) | -- | 1970 | -- | 9.8 | 22.0 | Good | 88.7 | C002811308 |
NBI report | N36 | ELKHORN RIVER OVERFLOW | 3W ELK CITY | Concrete Slab (3 spans) | -- | 1970 | -- | 33.1 | 82.0 | Fair | 79.1 | S036 00585 |
NBI report | PEDESTRAIN OVRPASS | CENTER ST | 48TH & CENTER OMAHA | Steel Box Beam or girders - Single or Spread | -- | 1970 | -- | 7.9 | -- | -- | -- | U182500898 |
NBI report | PEDESTRIAN OVRPASS | HWY 64 | 76TH & MAPLE OMAHA | Steel Box beam or girders - Multiple | -- | 1970 | -- | 96.1 | -- | -- | -- | S064 07348 |
NBI report | UPRR | UPRR 815-675-E | OMAHA 144TH @ US275 | Steel Stringer/Multi-beam or girder | -- | 1970 | -- | 860.0 | -- | -- | -- | U182503510 |
NBI report | 132ND ST/FAU 5003 | UPRR 815-674-X | OMAHA 132ND ST @ US 275 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 1978 | 119.1 | 206.0 | Fair | 59.1 | U182503705R |
NBI report | I480 14TH ST ACCES | I480 RAMP/13TH/12TH | IN OMAHA | Steel Girder and floorbeam system (5 spans) | -- | 1970 | 1994 | 113.9 | 538.1 | Fair | 72.0 | S480 00345E |
NBI report | I480 14TH ST EXIT | 12TH/13TH | IN OMAHA | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1970 | 1995 | 133.9 | 640.1 | Good | 69.4 | S480 00345F |
NBI report | I480/17TH ST ACCES | 19TH, 20TH | IN OMAHA | Steel Box Beam or girders - Single or Spread (7 spans) | -- | 1970 | 1997 | 131.9 | 851.1 | Fair | 71.3 | S480 00310B |
NBI report | I480/20TH ST EXIT | CHICAGO/DAVENPORT/20TH | IN OMAHA | Steel Box Beam or girders - Single or Spread (10 spans) | -- | 1970 | 1997 | 71.9 | 621.1 | Fair | 64.2 | S480 00310A |
NBI report | F ST/FAU 5030 | US75 | KENNEDY EXP/F ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1970 | 1998 | 67.9 | 213.9 | Fair | 80.1 | S075 08766 |
NBI report | I480 13TH ST ACCES | 14TH/15TH STS | IN OMAHA | Steel Stringer/Multi-beam or girder (8 spans) | -- | 1970 | 1998 | 133.9 | 795.0 | Good | 79.3 | S480 00345D |
NBI report | PACIFIC ST/FAU5044 | LITTLE PAPILLION CREEK | OMAHA PACIFIC @ 69TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 1998 | 55.1 | 136.2 | Fair | 63.4 | U182522225 |
NBI report | WB-I480 | 20TH THRU 16TH/FAU 5095 | IN OMAHA | Steel Box beam or girders - Multiple (14 spans) | -- | 1970 | 1998 | 134.8 | 1571.9 | Good | 67.0 | S480 00310L |
NBI report | WB-I480 | 15TH THRU 12TH | IN OMAHA | Steel Box beam or girders - Multiple (12 spans) | -- | 1970 | 1998 | 134.8 | 1490.2 | Fair | 41.2 | S480 00345L |
NBI report | EB-I480 | 20TH THRU 16TH/FAU 5095 | IN OMAHA | Steel Box beam or girders - Multiple (13 spans) | -- | 1970 | 1999 | 129.9 | 1581.1 | Fair | 64.1 | S480 00310R |
NBI report | EB-I480 | 15TH THRU 12TH | IN OMAHA | Steel Box beam or girders - Multiple (12 spans) | -- | 1970 | 1999 | 134.8 | 1490.2 | Good | 63.1 | S480 00345R |
NBI report | EB-I480 | 11TH THRU MISSOURI BR | IN OMAHA | Steel Stringer/Multi-beam or girder (21 spans) | -- | 1970 | 1999 | 149.0 | 2488.0 | Fair | 50.8 | S480 00378R |
NBI report | I480 14TH ST EXIT | 16TH/15TH/FAU 5095 | IN OMAHA | Steel Box Beam or girders - Single or Spread (5 spans) | -- | 1970 | 1999 | 129.9 | 595.2 | Fair | 70.2 | S480 00345C |
NBI report | WB-I480 | 11TH THRU MISSOURI BR | IN OMAHA | Steel Stringer/Multi-beam or girder (21 spans) | -- | 1970 | 2001 | 171.9 | 2481.1 | Good | 48.4 | S480 00378L |
NBI report | S BRDG RD/FAU5164 | BIG PAPILLION CREEK | S BRIDGE ROAD @ 111TH ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 2004 | 100.1 | 263.1 | Fair | 86.1 | U1825C2005 |
NBI report | US75 | J ST | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 2007 | 66.9 | 185.0 | Poor | 78.1 | S075 08730L |
NBI report | US75 | J ST | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | 2007 | 66.9 | 185.0 | Fair | 79.1 | S075 08730R |
NBI report | GINGER COVE ROAD | GINGER COVE LAKE | JCT US275/N64 2W .5S | Steel Girder and floorbeam system | -- | 1971 | -- | 60.0 | 61.0 | Fair | 70.7 | C002801205P |
NBI report | PEDESTRAIN OVRPASS | HWY 64 | 66TH & MAPLE OMAHA | Steel Box beam or girders - Multiple | -- | 1971 | -- | 69.9 | -- | -- | -- | S064 07451 |
NBI report | PEDESTRAIN OVRPASS | ROADWAY | 30TH @ SPAULDING ST | Steel Stringer/Multi-beam or girder | -- | 1971 | -- | 79.1 | -- | -- | -- | U1825F5345 |
NBI report | PEDESTRIAN OVRPASS | HWY 6 | DODGE @ HAPPY HOLLOW | Steel Stringer/Multi-beam or girder | -- | 1971 | -- | 77.1 | -- | -- | -- | S006 36906 |
NBI report | I680 | IRVINGTON RD | IN OMAHA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | 1975 | 53.2 | 141.1 | Good | 85.3 | S680 00761L |
NBI report | I680 | IRVINGTON RD | IN OMAHA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | 1975 | 53.2 | 141.1 | Good | 85.3 | S680 00761R |
NBI report | I680 | US75 | US75 INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1975 | 46.9 | 165.0 | Fair | 48.4 | S680 01210L |
NBI report | I680 | US75 | US75 INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1975 | 46.9 | 165.0 | Fair | 98.0 | S680 01210R |
NBI report | I680 | ABND CNWTC/THOMAS CR | IN OMAHA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1994 | 89.9 | 285.1 | Good | 81.8 | S680 00747L |
NBI report | I680 | ABND CNWTC/THOMAS CR | IN OMAHA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1994 | 89.9 | 285.1 | Good | 85.7 | S680 00747R |
NBI report | I680 | COLL 39C/KNIGHT CR | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | 1994 | 86.9 | 226.1 | Fair | 83.1 | S680 00836L |
NBI report | I680 | COLL 39C/KNIGHT CR | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | 1994 | 86.9 | 226.1 | Fair | 84.1 | S680 00836R |
NBI report | N36 | BIG PAPILLION CREEK | 2W BENNINGTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | 1994 | 67.9 | 173.9 | Fair | 86.7 | S036 01281 |
NBI report | 36TH ST | PONCA CREEK | 36TH & PONCA RD | Steel Culvert | -- | 1972 | -- | 25.9 | 25.9 | Fair | 88.7 | C002815305 |
NBI report | BEDFORD AVENUE | COLE CREEK | OMAHA BEDFORD @ 72ND | Concrete Culvert (2 spans) | -- | 1972 | -- | 12.1 | 25.9 | Good | 86.7 | U1825H1605 |
NBI report | CASS ST/FAU 5060 | COLE CREEK | OMAHA CASS @ 77TH | Concrete Culvert (3 spans) | -- | 1972 | -- | 12.1 | 95.1 | Fair | 57.8 | U182512030 |
NBI report | PEDESTRIAN OVRPASS | FORT ST | FORT ST. @ 99TH ST. | Concrete Tee beam | -- | 1972 | -- | 89.9 | -- | -- | -- | U182521423 |
NBI report | I680 | 60TH ST/FAU 5043 | 72ND ST INTRCHG 1E | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | 1975 | 53.2 | 141.1 | Good | 86.0 | S680 01092L |
NBI report | I680 | 60TH ST/FAU 5043 | 72ND ST INTRCHG 1E | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | 1975 | 53.2 | 141.1 | Good | 86.0 | S680 01092R |
NBI report | PADDOCK ROAD | STREAM | OMAHA PADDOCK @ W CENTER | Steel Stringer/Multi-beam or girder | -- | 1972 | 1992 | 49.9 | 51.8 | Fair | 59.1 | U1825E4305 |
NBI report | I680 | ABND CNWTC/N36 | US75 INTRCHG 1W | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1972 | 1994 | 65.0 | 358.0 | Fair | 87.1 | S680 01150L |
NBI report | I680 | ABND CNWTC/N36 | US75 INTRCHG 1W | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1972 | 1994 | 65.0 | 358.0 | Fair | 87.1 | S680 01150R |
NBI report | I80 | 16TH ST/FAU 5095 | IN OMAHA | Steel Stringer/Multi-beam or girder | -- | 1972 | 1996 | 120.1 | 123.0 | Fair | 83.0 | S080 45389 |
NBI report | I80 | BNSF/MO R 074-676-M | ECL OMAHA | Steel Stringer/Multi-beam or girder (12 spans) | -- | 1972 | 2010 | 424.9 | 2468.0 | Fair | 73.0 | S080 45531R |
NBI report | I680 | MISSOURI RIVER | ECL OMAHA | Steel Truss - Thru (3 spans) | -- | 1973 | -- | 420.0 | 1711.0 | Fair | 69.0 | S680 01343L |
NBI report | PEDESTRIAN OVRPASS | S SADDLE CREEK RD | OMAHA SADDLE CR/WOOLWORTH | Steel Girder and floorbeam system | -- | 1973 | -- | 88.9 | -- | -- | -- | U1825D2203 |
NBI report | F ST/FAU 5030 | UPRR 191-594-B | OMAHA F @ 43RD | Concrete Stringer/Multi-beam or girder (3 spans) | -- | 1973 | 1977 | 65.0 | 161.1 | Fair | 32.7 | U1825E5105 |
NBI report | I680 | L28H MORMON BRGE INTRCG | 31ST ST INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1973 | 2000 | 60.0 | 178.2 | Good | 98.0 | S680 01305L |
NBI report | I680 | L28H MORMON BRGE INTRCG | 31ST ST INTRCHG | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1973 | 2000 | 60.0 | 178.2 | Fair | 98.0 | S680 01305R |
NBI report | WB-US6 | 108TH ST | 108TH & DODGE INTRCHG | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1973 | 2003 | 83.0 | 158.1 | Fair | 77.9 | S006 36484 |
NBI report | F ST/FAU 5028 | BIG PAPILLION CREEK | F @ 80TH ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1974 | 1982 | 89.9 | 243.1 | Fair | 67.9 | U182532605 |
NBI report | 120TH ST/FAU 5009 | HELL CREEK | OMAHA 120TH @ I | Concrete Culvert (2 spans) | -- | 1974 | 1992 | 12.1 | 24.9 | Good | 54.8 | U182503905 |
NBI report | N64 | PLATTE RIVER TRIB | 2.5W VALLEY | Concrete Slab (4 spans) | -- | 1975 | -- | 49.9 | 182.1 | Fair | 80.0 | S064 05319 |
NBI report | PARKING GARAGE | PARKING GARAGE | OMAHA 17TH @ FARNAM | Concrete Stringer/Multi-beam or girder | -- | 1975 | -- | 86.0 | -- | -- | -- | U1825I5515 |
NBI report | PEDESTRAIN OVRPASS | W CENTER RD | 86TH & WEST CENTER | Steel Girder and floorbeam system | -- | 1975 | -- | 92.5 | -- | -- | -- | U182500573 |
NBI report | PEDESTRIAN OVRPASS | N 72ND ST | OMAHA 72ND @ WESTERN | Steel Girder and floorbeam system | -- | 1975 | -- | 97.1 | -- | -- | -- | U182504727 |
NBI report | COLL 7947 | RAWHIDE CREEK | 2E 2.7N OF VALLEY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1975 | 2001 | 49.9 | 138.1 | Fair | 98.6 | C002801730 |
NBI report | N36 | KNIGHT CREEK | 5E BENNINGTON | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1976 | -- | 60.0 | 157.2 | Fair | 95.0 | S036 02040R |
NBI report | PEDESTRAIN OVRPASS | HWY 64 | NW RADIAL & HAMILTON | Prestressed Stringer/Multi-beam or girder | -- | 1976 | -- | 60.0 | -- | -- | -- | S064 07686 |
NBI report | PEDESTRAIN OVRPASS | BLONDO ST | OMAHA BLONDO @ 69TH | Steel Girder and floorbeam system | -- | 1976 | -- | 98.1 | -- | -- | -- | U182531840 |
NBI report | PEDESTRIAN OVRPASS | ROADWAY | OMAHA AMES @ 33RD | Steel Girder and floorbeam system | -- | 1976 | -- | 71.9 | -- | -- | -- | U1825F1410 |
NBI report | 276TH ST/FAS 3795 | STREAM | JCT US275/N64 .3E 2.9N | Concrete Culvert (3 spans) | -- | 1977 | -- | 9.8 | 32.2 | Good | 85.8 | C002811305 |
NBI report | ARBOR STREET | HELL CREEK | OMAHA ARBOR @ 129TH | Prestressed Tee beam | -- | 1977 | -- | 40.0 | 41.0 | Fair | 88.3 | U1825Q3505 |
NBI report | HAMILTN ST/FAU5066 | US75 | HAMILTON ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1977 | -- | 111.9 | 194.9 | Poor | 84.3 | S075 09137 |
NBI report | HARRISN ST/FAU5022 | BIG PAPILLION CREEK | 2E N85 SARPY CL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 116.1 | 304.1 | Fair | 54.0 | U182503020 |
NBI report | PARKER ST | US75 | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 85.0 | 250.0 | Fair | 73.0 | S075 09169 |
NBI report | PEDESTRAIN OVRPASS | W CENTER RD | 139TH & WEST CENTER | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 86.9 | -- | -- | -- | U182500145 |
NBI report | PEDESTRAIN OVRPASS | ROADWAY | 30TH @ MAPLE ST | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 76.1 | -- | -- | -- | U1825F5340 |
NBI report | UPRR | UPRR 816-829-R | OMAHA 84TH @ F | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 108.9 | -- | -- | -- | U182504505 |
NBI report | BLONDO ST/FAU 5066 | LITTLE PAPILLION CREEK | OMAHA BLONDO @ 85TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | 1981 | 44.9 | 138.1 | Fair | 69.0 | U182531830 |
NBI report | 120TH ST/FAU 5009 | STREAM | OMAHA 120TH @ MILITARY | Concrete Culvert (2 spans) | -- | 1978 | -- | 9.8 | 22.0 | Good | 73.1 | U182513920 |
NBI report | 64TH AVENUE | STREAM | OMAHA 64TH @ CASTELAR | Concrete Culvert (2 spans) | -- | 1978 | -- | 12.1 | 27.9 | Good | 88.6 | U1825I4705 |
NBI report | EB-N64 | BIG PAPILLION CREEK | 7E ELKHORN | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | -- | 145.0 | 379.9 | Fair | 84.3 | S064 07011R |
NBI report | IDA ST | STREAM | OMAHA IDA @ 144TH ST | Concrete Culvert (2 spans) | -- | 1978 | -- | 12.1 | 27.9 | Good | 81.9 | U182511210 |
NBI report | O STREET | US75 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1978 | -- | 128.0 | 236.9 | Fair | 79.9 | S075 08682 |
NBI report | 72ND ST/FAU 5037 | BIG PAPILLION CREEK | OMAHA 72ND @ Q | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1978 | 1986 | 75.1 | 203.1 | Fair | 82.9 | U182504705 |
NBI report | 192ND ST COLL 121C | W BR PAPILLION CREEK | .9N 192ND & WEST DODG | Concrete Slab (3 spans) | -- | 1978 | 2006 | 42.0 | 102.0 | Fair | 66.6 | U182502715 |
NBI report | Q ST/FAU 5026 | US75 | KENNEDY EXP/Q ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1978 | 2014 | 121.1 | 212.0 | Fair | 66.8 | S075 08663 |
NBI report | 120TH ST/FAU 5009 | BIG PAPILLION CREEK | OMAHA 120TH @ W MAPLE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1980 | -- | 75.1 | 203.1 | Fair | 66.0 | U182513915 |
NBI report | 132ND ST/FAU 5003 | STREAM | .25S 132ND & W MAPLE RD | Concrete Culvert (2 spans) | -- | 1980 | -- | 12.1 | 24.9 | Fair | 71.8 | U182513715 |
NBI report | 13TH ST/FAU 5121 | CENTRAL PARK MALL | 13TH @ FARNAM | Steel Box beam or girders - Multiple (3 spans) | -- | 1980 | -- | 162.1 | 222.1 | Fair | 68.2 | U1825M5535 |
NBI report | FORT ST/FAU 5082 | BIG PAPILLION CREEK | JCT I680/N133 1.1S 1.8W | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1980 | -- | 116.1 | 304.1 | Fair | 76.0 | U182521420 |
NBI report | HARTMN AVE/FAU5084 | COLE CREEK | OMAHA HARTMAN @ 65TH | Prestressed Tee beam | -- | 1980 | -- | 40.0 | 41.0 | Fair | 70.9 | U1825J1205 |
NBI report | IDA ST/FAS 3824 | THOMAS CREEK | .1W IRVINGTON RD & IDA ST | Concrete Slab (3 spans) | -- | 1980 | -- | 47.9 | 121.1 | Fair | 60.2 | C002831210 |
NBI report | MERCY RD/FAU 5040 | LITTLE PAPILLION CREEK | OMAHA MERCY @ 65TH | Concrete Slab (3 spans) | -- | 1980 | -- | 51.8 | 130.9 | Fair | 67.9 | U1825J2205 |
NBI report | N STREET | HELL CREEK | OMAHA N @ 118TH | Prestressed Tee beam (3 spans) | -- | 1980 | -- | 40.0 | 110.9 | Fair | 79.3 | U1825I2603 |
NBI report | N38 | ABAND UPRR/PAPIO CR | 67TH & W CENTER RD OMAHA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1980 | -- | 106.0 | 333.0 | Fair | 67.8 | U182500728 |
NBI report | Q ST/FAU 5026 | W BR PAPILLION CREEK | OMAHA Q @ 136TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1980 | -- | 88.9 | 227.0 | Fair | 66.0 | U182502820 |
NBI report | STATE ST;COLL 7934 | THOMAS CREEK | 106TH & STATE ST | Concrete Slab (3 spans) | -- | 1980 | 2000 | 29.9 | 76.1 | Fair | 80.6 | C002821035 |
NBI report | PACIFIC ST/FAU5044 | W BR PAPILLION CREEK | OMAHA PACIFIC @ 162ND ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1980 | 2004 | 58.1 | 176.8 | Good | 82.2 | U182522217 |
NBI report | 144TH ST/FAU 5001 | W BR PAPILLION CREEK | 144TH @ F ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1981 | -- | 71.9 | 186.0 | Fair | 65.9 | U182503505L |
NBI report | BLONDO ST/FAU 5066 | COLE CREEK | BLONDO @ 78TH ST | Concrete Slab (3 spans) | -- | 1981 | -- | 32.2 | 82.0 | Fair | 66.0 | U182531835 |
NBI report | N64 | STREAM | 1E WATERLOO | Concrete Culvert (2 spans) | -- | 1981 | -- | 9.8 | 22.0 | Fair | 57.8 | S064 06054 |
NBI report | N64 | STREAM | 1E WATERLOO | Concrete Culvert (5 spans) | -- | 1981 | -- | 9.8 | 54.1 | Good | 57.7 | S064 06064 |
NBI report | N64 | STREAM | 2.3E WATERLOO | Concrete Culvert (5 spans) | -- | 1981 | -- | 9.8 | 54.1 | Good | 76.3 | S064 06125 |
NBI report | N64 | W BR PAPILLION CREEK | 1W ELKHORN | Concrete Culvert (4 spans) | -- | 1981 | -- | 7.9 | 44.0 | Fair | 62.3 | S064 06169 |
NBI report | PEDESTRAIN OVRPASS | N64 | 56TH & MAPLE ST OMAHA | Steel Stringer/Multi-beam or girder | -- | 1981 | -- | 124.0 | -- | -- | -- | S064 07536 |
NBI report | 156TH ST/FAU 5135 | W BR PAPILLION CREEK | 156TH @ CENTER ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1981 | 2010 | 75.1 | 202.1 | Good | 84.8 | U182503310 |
NBI report | I ST/FAU 5028 | HELL CREEK | OMAHA I @ 120TH | Prestressed Tee beam (3 spans) | -- | 1981 | 2010 | 35.1 | 86.0 | Good | 85.3 | U1825C2605 |
NBI report | 120TH ST/FAU 5009 | BIG PAPILLION CREEK TRIB | .25S 120TH & W MAPLE | Prestressed Tee beam (3 spans) | -- | 1982 | -- | 38.1 | 115.2 | Fair | 66.0 | U182513910 |
NBI report | 132ND ST/FAU 5005 | W BR PAPILLION CREEK | OMAHA 132ND @ Q | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1982 | -- | 67.9 | 170.0 | Fair | 62.9 | U182503703 |
NBI report | F ST/FAU 5030 | UPRR 817-392-N | OMAHA F @ BUCKINGHAM | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1982 | -- | 143.1 | 845.2 | Fair | 51.7 | U182542625 |
NBI report | FAS 5066 | W BR PAPILLION CREEK | 162ND & BLONDO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1982 | -- | 55.1 | 145.0 | Good | 71.0 | U182521820 |
NBI report | PARKVIEW LANE | COLE CREEK | PARKVIEW LANE @ 66TH | Concrete Culvert (3 spans) | -- | 1982 | -- | 12.1 | 37.1 | Good | 87.2 | U1825M1205 |
NBI report | PEDESTRIAN OVRPASS | HWY 6 | DOUGLAS ST @ 15TH OMAHA | Concrete Tee beam | -- | 1982 | -- | 100.1 | -- | -- | -- | S006 37260 |
NBI report | LAKE ST/FAU 5068 | US75 | LAKE ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1982 | 2014 | 111.9 | 208.0 | Good | 82.8 | S075 09202 |
NBI report | 132ND ST/FAU 5005 | STREAM | OMAHA 132ND @ Z ST | Concrete Culvert (2 spans) | -- | 1983 | -- | 9.8 | 22.0 | Good | 79.8 | U182503702 |
NBI report | EB-N64 | N BR W PAPILLION CREEK | 3E ELKHORN | Prestressed Tee beam (3 spans) | -- | 1983 | -- | 40.0 | 121.1 | Poor | 58.0 | S064 06616R |
NBI report | FLORENCE BLVD | STORZ EXPRESSWAY/FAU5098 | FLRNCE/STORZ EXP INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1983 | -- | 110.9 | 205.1 | Good | 77.5 | U1825C5515 |
NBI report | FORT ST/FAU 5082 | LITTLE PAPILLION CREEK | FORT ST @ 88TH ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 40.0 | 102.0 | Good | 53.8 | U182521425 |
NBI report | GROVER ST/FAU 5036 | LITTLE PAPILLION CREEK | OMAHA GROVER @ 66TH | Concrete Slab (3 spans) | -- | 1983 | -- | 61.0 | 154.9 | Good | 69.0 | U1825H2405 |
NBI report | L ST/FAU 5140 | W BR PAPILLION CREEK | 141ST & L ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 67.9 | 170.0 | Fair | 60.2 | U182512605P |
NBI report | PEDESTRAIN OVRPASS | HWY 133 | OMAHA 90TH @ WESTERN | Steel Stringer/Multi-beam or girder | -- | 1983 | -- | 96.1 | -- | -- | -- | S133 00052 |
NBI report | Q ST/FAU 5026 | BIG PAPILLION CREEK | OMAHA Q @ 69TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | -- | 109.9 | 280.9 | Fair | 72.9 | U182512830 |
NBI report | STATE STREET | W BR PAPILLION CREEK | 183RD & STATE ST | Prestressed Box beam or girders - Multiple | -- | 1983 | -- | 53.2 | 53.2 | Fair | 86.0 | C002821020 |
NBI report | 186TH STREET | STREAM | .5S 186TH & STATE ST | Prestressed Tee beam | -- | 1983 | 2001 | 53.2 | 53.2 | Good | 99.5 | C002802705P |
NBI report | MILTRY AV/FAS3806 | BIG PAPILLION CREEK | 124TH & MILITARY AVENUE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1983 | 2006 | 75.1 | 202.1 | Fair | 67.9 | C002831205P |
NBI report | 10TH ST/FAU 5103 | LAGOON | OMAHA 10TH FARNAM/DOUGLAS | Steel Box beam or girders - Multiple (2 spans) | -- | 1983 | 2011 | 87.9 | 179.1 | Good | 71.6 | U1825Q5510 |
NBI report | 264TH ST | STREAM | WJCT US275/N92 2W 1S | Prestressed Tee beam | -- | 1983 | 2012 | 62.0 | 63.0 | Good | 95.8 | C002801505 |
NBI report | 105TH ST/FAU 5013 | BIG PAPILLION CREEK | OMAHA 105TH @ PACIFIC | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 75.1 | 203.1 | Fair | 65.3 | U1825F4110 |
NBI report | 132ND ST/FAU 5003 | UPRR 815-674-X | OMAHA 132ND ST @ US 275 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 119.1 | 226.1 | Good | 62.0 | U182503705L |
NBI report | 153RD STREET | STREAM | 153RD & PINE ST. | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 24.9 | Good | 88.6 | U182502205P |
NBI report | 158TH STREET | STREAM | 158TH & WOOLWORTH AVE | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 24.9 | Good | 88.6 | U182503110P |
NBI report | 24TH STREET/FAU 50 | STORZ EXPRESSWAY/FAU5098 | OMAHA 24TH @ STORZ EXPRWY | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 116.1 | 220.2 | Good | 95.1 | U182505530 |
NBI report | AMES AVE/FAU 5080 | US75 | AMES AVE/STORZ EXP INTCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 148.0 | 280.9 | Good | 84.0 | S075 09327 |
NBI report | BOYD ST/FAU 5078 | LITTLE PAPILLION CREEK | OMAHA BOYD @ 88TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1984 | -- | 40.0 | 102.0 | Good | 43.7 | U1825E1405 |
NBI report | BRISTOL ST | US75 | OMAHA BRISTOL @ US75 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 95.1 | 191.9 | Good | 91.0 | S075 09255 |
NBI report | CALHOUN RD/COL7965 | PONCA CREEK | NR CALHOUN RD & PONC RD | Prestressed Tee beam (3 spans) | -- | 1984 | -- | 34.1 | 99.1 | Fair | 82.4 | C002805104P |
NBI report | NORTH RIDGE DRIVE | STATE STREET | OMAHA N RIDGE DR @ STATE | Steel Box beam or girders - Multiple | -- | 1984 | -- | 120.1 | 121.1 | Good | 93.9 | U1825A1005 |
NBI report | PEDESTRIAN OVRPASS | ROADWAY | 16TH @ FARNMAN/DOUGLAS | Concrete Stringer/Multi-beam or girder | -- | 1984 | -- | 111.9 | -- | -- | -- | U1825J5507 |
NBI report | S.I.D. ROAD | STREAM | 135TH & MIAMI ST. | Concrete Culvert (2 spans) | -- | 1984 | -- | 9.8 | 24.0 | Fair | 86.7 | U182503505P |
NBI report | STATE ST/FAU 5134 | KNIGHT CREEK | OMAHA STATE @ 90TH | Concrete Culvert (2 spans) | -- | 1984 | -- | 9.8 | 22.0 | Good | 82.0 | U182521040 |
NBI report | US275 | N64 | SEJCT US275/N64 .2S | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1984 | -- | 102.0 | 277.9 | Fair | 84.0 | S275 16648 |
NBI report | US275 | UPRR 816-864-E | .2E WATERLOO | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1984 | -- | 130.9 | 400.0 | Fair | 85.0 | S275 16664 |
NBI report | US275 | STREAM | SEJCT US275/N64 .7S | Concrete Culvert (3 spans) | -- | 1984 | -- | 7.9 | 25.9 | Good | 57.7 | S275 16725 |
NBI report | N64 | ELKHORN RIVER | 1NE WATERLOO | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1984 | 2017 | 155.8 | 403.9 | Fair | 85.5 | S064 06033 |
NBI report | 168TH ST/FAS 3811 | BOX ELDER CREEK | .2N 168TH & F STS | Concrete Slab (3 spans) | -- | 1985 | -- | 45.9 | 116.1 | Fair | 63.0 | U182503110 |
NBI report | BENNINGTON ROAD | BIG PAPILLION CREEK | .3W OF BENNINGTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 74.2 | 191.9 | Fair | 82.1 | C002810615 |
NBI report | BINNEY ST | US75 | OMAHA US75 & BINNEY ST | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1985 | -- | 98.1 | 194.9 | Good | 74.2 | S075 09233 |
NBI report | OLD LINCOLN HWY | STREAM | .3N 174TH & US6 | Steel Culvert | -- | 1985 | -- | 21.0 | 22.0 | Good | 99.0 | C002802905P |
NBI report | PONCA RD/COLL 7949 | STREAM | 42ND & PONCA ROAD | Prestressed Box beam or girders - Multiple | -- | 1985 | -- | 60.0 | 61.0 | Fair | 87.4 | C002800420P |
NBI report | VINTON ST/FAU 5036 | UP/BNSF RR 816-821-L | OMAHA VINTON @ 28TH | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1985 | -- | 130.9 | 594.2 | Good | 67.2 | U1825D2405 |
NBI report | WEST MAPLE ROAD | STREAM | 1SW VALLEY | Metal Culvert (2 spans) | -- | 1985 | -- | 12.1 | 28.9 | Fair | 88.7 | C002801610 |
NBI report | WEST MAPLE ROAD | STREAM | 1SW VALLEY | Metal Culvert (2 spans) | -- | 1985 | -- | 12.1 | 28.9 | Fair | 99.7 | C002801615 |
NBI report | IDA STREET | W BR PAPILLION CREEK | 177TH & IDA ST | Prestressed Tee beam (3 spans) | Closed | 1985 | 2001 | 38.1 | 113.9 | -- | 31.7 | C002811205 |
NBI report | 126TH ST | BIG PAPILLION CREEK | 126TH & MILITARY AVE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1985 | 2006 | 75.1 | 202.1 | Fair | 86.9 | C002813715P |
NBI report | 108TH ST/FAU 5011 | UPRR 816-831-S | OMAHA 108TH @ I | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 89.9 | 220.2 | Good | 68.0 | U182504105 |
NBI report | 72ND ST /FAU 5037 | STREAM | OMAHA 72ND @ MAIN ST | Concrete Culvert (3 spans) | -- | 1986 | -- | 12.1 | 38.1 | Good | 57.8 | U182504704 |
NBI report | BLONDO ST/FAS 3810 | STREAM | 179TH & BLONDO | Concrete Slab (3 spans) | -- | 1986 | -- | 36.1 | 91.9 | Fair | 73.6 | C002821815 |
NBI report | HARRISN ST/FAU5022 | BNSF/UPRR 073-045-H | 1W N85 SARPY CL | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | -- | 96.1 | 233.0 | Fair | 83.0 | U182503015 |
NBI report | PEDESTRIAN OVRPASS | HWY 75 | US75 @ MANDERSON OMAHA | Steel Stringer/Multi-beam or girder | -- | 1986 | -- | 92.9 | -- | -- | -- | S075 09280 |
NBI report | PEDESTRIAN OVRPASS | ROADWAY | 33RD @ HARNEY ST | Steel Girder and floorbeam system | -- | 1986 | -- | 71.9 | -- | -- | -- | U1825D5310 |
NBI report | PEDESTRIAN OVRPASS | ROADWAY | 18TH ST N. OF FARNAM ST | Steel Girder and floorbeam system | -- | 1986 | -- | 190.0 | -- | -- | -- | U1825H5515 |
NBI report | SPRAGUE ST/FAU507 | US75 | SPRAGUE @ US75 OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 105.0 | 212.0 | Good | 80.0 | S075 09302 |
NBI report | COLL 7934 | BIG PAPILLION CREEK | 138TH & STATE | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | 2012 | 82.0 | 219.2 | Fair | 64.1 | C002821025 |
NBI report | SB-STORZ EXP | NB-US75 | AMES AVE/STORZ EXP INTCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | 2014 | 83.0 | 191.0 | Good | 95.3 | S075 09341 |
NBI report | SB-STORZ EXP | EB-HARTMAN CONN/FAU 5098 | AMES AVE/STORZ EXP INTCHG | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1986 | 2014 | 73.2 | 179.1 | Good | 88.7 | S075 09354A |
NBI report | 168TH STREET | BIG PAPILLION CREEK | 1NW OF BENNINGTON | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 69.9 | 185.0 | Fair | 98.4 | C002813140 |
NBI report | 180TH ST | STREAM | .3S 180TH & N64 | Concrete Slab (3 spans) | -- | 1987 | -- | 40.0 | 102.0 | Fair | 77.8 | C002812910 |
NBI report | 240TH STREET | STREAM | 4S OF WATERLOO | Concrete Slab (3 spans) | -- | 1987 | -- | 40.0 | 103.0 | Fair | 99.9 | C002801905 |
NBI report | HARRISN ST/FAU5022 | HELL CREEK | 2W N85 SARPY CL | Concrete Slab (3 spans) | -- | 1987 | -- | 42.0 | 107.9 | Fair | 85.0 | U182503010 |
NBI report | PACIFIC STREET | STREAM | 2.5S 3W OF WATERLOO | Metal Culvert (2 spans) | -- | 1987 | -- | 12.1 | 27.9 | Fair | 99.7 | C002802205 |
NBI report | STORZ EXPRESSWAY | UPRR 816-152-D | STORZ EXP @ 12TH ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 54.1 | 166.0 | Good | 90.4 | U1825J1225 |
NBI report | PRIVATE ACESS ROAD | STREAM | 111TH ST @ CHARLES ST | Steel Girder and floorbeam system | -- | 1987 | 2010 | 30.8 | 32.2 | Good | 48.8 | U1825D1825 |
NBI report | 180TH STREET | BOX ELDER CREEK | .4S 180TH & US275 | Concrete Slab (3 spans) | -- | 1988 | -- | 51.8 | 130.9 | Fair | 62.9 | U182502905 |
NBI report | 192ND ST | BOX ELDER CREEK | JCT US275/192ND ST .2S | Prestressed Tee beam (4 spans) | -- | 1988 | -- | 41.0 | 162.1 | Good | 68.0 | U182502705 |
NBI report | 32ND AVE/FAU 5063 | I80/RMP 40/RMP 50 | JCT 32ND AVE/I80 OMAHA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1988 | -- | 122.1 | 490.2 | Good | 88.0 | S080 45266 |
NBI report | 36TH ST | I80 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 149.0 | 295.9 | Fair | 71.1 | S080 45231 |
NBI report | 96TH ST/FAU 5017 | I80 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 126.0 | 250.0 | Good | 67.8 | S080 44725 |
NBI report | NB-I480 | I-480 RMP 40 | GROVER ST INTRCHG | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 111.9 | 115.2 | Fair | 80.0 | S480 00019R |
NBI report | POTWIN ST | WEST PAPILLION CR TRIB | OMAHA POTWIN @ 134TH | Concrete Culvert (2 spans) | -- | 1988 | -- | 9.8 | 24.0 | Good | 88.6 | U1825G3515 |
NBI report | SB-I480 | I-480 RMP 40 | GROVER ST INTRCHG | Steel Stringer/Multi-beam or girder | -- | 1988 | -- | 111.9 | 115.2 | Good | 80.0 | S480 00019L |
NBI report | VINTON ST/FAU 5036 | I480/RMP 40/RMP 50 | IN OMAHA | Steel Stringer/Multi-beam or girder (5 spans) | -- | 1988 | -- | 140.1 | 579.1 | Fair | 81.9 | S480 00022 |
NBI report | WB-CD | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 85.0 | 211.0 | Good | 95.8 | S080 44572 |
NBI report | WB-I80 OFF RAMP | BIG PAPILLION CR/82AV&AM | I80 @ BIG PAPILLION CR | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 118.1 | 344.2 | Good | 78.0 | S080 44846A |
NBI report | 20TH ST/FAU 5089 | I80 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1989 | -- | 154.9 | 274.0 | Good | 84.9 | S080 45361 |
NBI report | 216TH ST | STREAM | .3N 216TH & N36 | Concrete Culvert (2 spans) | -- | 1989 | -- | 8.9 | 21.0 | Fair | 85.2 | C002812305 |
NBI report | BNSF RR | BNSF RR 073-050-E | 72ND @ WASHINGTON | Steel Stringer/Multi-beam or girder | -- | 1989 | -- | 43.0 | -- | -- | -- | U182504703 |
NBI report | EB-I80 | BNSF/UPRR 816-822-T | GROVER ST INTRCHG #2 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1989 | -- | 123.0 | 584.0 | Fair | 80.0 | S080 45298R |
NBI report | OLD MAPLE ROAD | STREAM | JCT US275/N64 .75E | Concrete Culvert (2 spans) | -- | 1989 | -- | 9.8 | 21.0 | Good | 83.5 | C002801403P |
NBI report | VERNON AVENUE | KNIGHT CREEK | IRVINGTON AREA | Concrete Culvert (2 spans) | -- | 1989 | -- | 16.1 | 33.1 | Good | 70.4 | C002841210P |
NBI report | WB-I80 | BNSF/UPRR 816-822-T | GROVER ST INTRCHG #1 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1989 | -- | 123.0 | 584.0 | Fair | 80.0 | S080 45298L |
NBI report | WOOLWORTH AVE | ABANDONED UPRR | OMAHA WOOLWORTH @ 39TH | Prestressed Tee beam (3 spans) | -- | 1989 | -- | 57.1 | 170.9 | Good | 85.0 | U1825D2205 |
NBI report | US275/N92 | W BR PAPILLION CREEK | 1W WCL OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1989 | 1991 | 100.1 | 222.1 | Fair | 80.1 | S275 17757 |
NBI report | NB-I480 | I80/RAMP 4 | GROVER ST INTRCHG #4 | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1989 | 1992 | 242.1 | 1428.2 | Good | 68.3 | S080 45303B |
NBI report | NB-US75/WB-I80 | I80/BN&UP/I480/RMP 50 | GROVER ST INTRCHG #8 | Steel Stringer/Multi-beam or girder (14 spans) | -- | 1989 | 1992 | 174.9 | 1995.2 | Good | 76.0 | S080 45308 |
NBI report | SB-I480/EB-I80 | I80/SB-US75/RMP 6/US-75 | GROVER ST INTRCHG #7 | Steel Stringer/Multi-beam or girder (7 spans) | -- | 1989 | 1992 | 243.1 | 1345.2 | Good | 73.0 | S080 45298A |
NBI report | 168TH ST/FAS 3811 | STREAM | .3N 168TH & HARRISON | Concrete Culvert (2 spans) | -- | 1989 | 1998 | 12.1 | 25.9 | Fair | 57.8 | C002803105 |
NBI report | EB-I80 | 42ND ST/FAU 5057 | 42ND ST INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1989 | 2007 | 66.9 | 205.1 | Good | 98.0 | S080 45180R |
NBI report | SB-I480 | I80/RAMP 4 | GROVER ST INTRCHG #3 | Steel Stringer/Multi-beam or girder (10 spans) | -- | 1989 | 2007 | 252.0 | 1538.1 | Good | 76.0 | S080 45303A |
NBI report | 24TH ST RMP TO I80 | WB-I80 TO SB-US75 RMP 4 | GROVER ST INTRCHG #16 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 181.1 | 377.0 | Fair | 100.0 | S080 45316 |
NBI report | EB-I80 | I480 NB | GROVER ST INTRCHG | Steel Stringer/Multi-beam or girder | -- | 1990 | -- | 155.8 | 159.1 | Fair | 98.0 | S080 45283R |
NBI report | EB-I80 | WB-I80 TO SB-US75 RMP #4 | GROVER ST INTRCHG #10 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 105.0 | 251.0 | Fair | 98.0 | S080 45314R |
NBI report | MARTHA ST/FAU 5038 | UP/BNSF/26TH 816-819-K | OMAHA MARTHA @ 26TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 220.2 | 930.2 | Fair | 65.9 | U1825K2205 |
NBI report | PACIFIC STREET | ROAD DITCH | 252ND ST AND PACIFIC | Concrete Culvert (2 spans) | -- | 1990 | -- | 9.8 | 21.0 | Good | 88.0 | C002802210 |
NBI report | W. DODGE; FAS 3800 | ROAD DITCH | 1.5S 1W WATERLOO | Concrete Culvert (3 spans) | -- | 1990 | -- | 6.9 | 22.0 | Good | 86.1 | C002802005 |
NBI report | WB-I80 | WB-I80 TO SB-US75 RMP 4 | GROVER ST INTRCHG #9 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1990 | -- | 107.9 | 257.9 | Good | 98.0 | S080 45314L |
NBI report | WB-I80 | I480 NB | GROVER ST INTRCHG | Steel Stringer/Multi-beam or girder | -- | 1990 | 2013 | 128.0 | 130.9 | Good | 98.0 | S080 45283L |
NBI report | 252ND STREET | STREAM | 5.5S 1W OF WATERLOO | Concrete Slab (3 spans) | -- | 1991 | -- | 44.0 | 109.9 | Fair | 99.8 | C002801705 |
NBI report | DUTCH HALL ROAD | STREAM | 3E N133 WASHINGTON CL | Concrete Culvert (2 spans) | -- | 1991 | -- | 12.1 | 35.1 | Fair | 88.2 | C002820265 |
NBI report | FAU 5003/132ND ST | US6/WEST DODGE ST | 132ND ST @ W DODGE ST | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1991 | -- | 112.9 | 224.1 | Good | 80.0 | S006 36293 |
NBI report | FAU5044/PACIFIC ST | UPRR 813-884-F | OMAHA PACIFIC @ 160TH ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 94.2 | 216.9 | Good | 83.0 | U182522218 |
NBI report | NB-US75 | GILMRE/UPRR 816-139-P | OMAHA @ GILMORE AVE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1991 | -- | 185.0 | 1361.0 | Fair | 85.0 | S075 08580R |
NBI report | PAWNEE ROAD | LITTLE PAPILLION CREEK | OMAHA PAWNEE @ 96TH | Prestressed Tee beam (3 spans) | -- | 1991 | -- | 42.0 | 107.0 | Good | 97.7 | U182500415 |
NBI report | PEDESTRIAN OVRPASS | ROADWAY | 8TH ST N OF FARNAM ST | Steel Truss - Thru | -- | 1991 | -- | 61.0 | -- | -- | -- | U1825A5725 |
NBI report | PEDESTRIAN OVRPASS | PEDESTRIAN OVERPASS | DODGE ST @ 83RD ST | Steel Girder and floorbeam system | -- | 1991 | -- | 10.5 | -- | -- | -- | U1825D2025 |
NBI report | SB-US75 | GILMRE/UPRR 816-139-P | OMAHA @ GILMORE AVE | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1991 | -- | 185.0 | 1361.0 | Fair | 85.0 | S075 08580L |
NBI report | US6/WEST DODGE ST | 137TH ST | W DODGE @ 138TH STOMAHA | Prestressed Stringer/Multi-beam or girder | -- | 1991 | -- | 78.1 | 80.1 | Good | 83.0 | S006 36240 |
NBI report | WB-N64 | N BR W PAPILLION CREEK | 3E ELKHORN | Prestressed Tee beam (3 spans) | -- | 1991 | -- | 41.0 | 123.0 | Poor | 58.0 | S064 06616L |
NBI report | 124TH ST/FAU 5152 | PAPILLION CREEK | .3SW OF 120TH/MAPLE ST | Prestressed Tee beam (3 spans) | -- | 1992 | -- | 42.0 | 123.0 | Good | 94.2 | U182531625P |
NBI report | 150TH ST/FAU 5144 | US6/W DODGE RD | 150TH @ W DODGE OMAHA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1992 | -- | 67.9 | 139.1 | Fair | 90.6 | S006 36142 |
NBI report | 24TH RMP TO WB-I80 | 24TH ST | 24TH ST INTRCHG | Prestressed Stringer/Multi-beam or girder (11 spans) | -- | 1992 | -- | 76.1 | 797.0 | Good | 85.0 | S080 45335 |
NBI report | BENNINGTON ROAD | RAWHIDE CREEK | 3N 2E OF VALLEY | Concrete Slab (3 spans) | -- | 1992 | -- | 47.9 | 121.1 | Fair | 99.9 | C002800610 |
NBI report | EB-I80 RMP TO 24TH | 24TH ST | 24TH ST INTRCHG | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1992 | -- | 68.9 | 309.1 | Good | 85.0 | S080 45334 |
NBI report | EB-I80/SB-US75 RP6 | BNSF/UPRR 816-822-T | GROVER ST INTRCHG | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1992 | -- | 139.1 | 938.0 | Fair | 85.0 | S080 45301 |
NBI report | FAU 5001/144TH ST | US6/W DODGE RD | 144TH @ W DODGE OMAHA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1992 | -- | 67.9 | 137.1 | Fair | 99.0 | S006 36192 |
NBI report | PAWNEE ROAD | PAPIO CREEK | 1S 2.5W N133/WASHGTON CL | Concrete Culvert (2 spans) | -- | 1992 | -- | 12.1 | 24.9 | Fair | 77.5 | C002800403 |
NBI report | WB-I80/NB-I480 RP3 | BNSF/UPRR 816-822-T | GROVER ST INTRCHG | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1992 | -- | 129.9 | 671.0 | Good | 85.0 | S080 45297 |
NBI report | 148 TH STREET | STREAM | .2N HILLSDALE & 148TH | Concrete Culvert (4 spans) | -- | 1993 | -- | 12.1 | 51.8 | Good | 99.2 | U182503005P |
NBI report | 216TH ST | WEST PAPIO CREEK | JCT N64/N31 1N 1W | Concrete Culvert (2 spans) | -- | 1993 | -- | 11.2 | 24.9 | Good | 87.0 | C002812303 |
NBI report | EB-L28B | ELKHORN RIVER | 18W OMAHA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1993 | -- | 105.0 | 524.0 | Fair | 84.9 | SL28B00163R |
NBI report | NB-RP TO I680 BR#3 | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1993 | -- | 98.1 | 209.0 | Good | 86.8 | S080 44575 |
NBI report | UPRR | UPRR 815-673-R | OMAHA 120TH @ PEDERSEN | Steel Stringer/Multi-beam or girder | -- | 1993 | -- | 85.0 | -- | -- | -- | U182503907 |
NBI report | WB-L28B | ELKHORN RIVER | 18W OMAHA | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1993 | -- | 105.0 | 524.0 | Fair | 84.9 | SL28B00163L |
NBI report | Y STREET | STREAM | Y ST @ 168TH ST | Concrete Culvert (3 spans) | -- | 1993 | -- | 7.9 | 26.9 | Good | 85.8 | U182502903P |
NBI report | 108TH ST/FAU 5011 | EB-CD/RP10/I80/RP11/WBCD | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 160.1 | 412.1 | Fair | 67.0 | S080 44625 |
NBI report Bridgehunter | 24TH ST/FAU 5083 | UP/BNSF RR 816-818-D | OMAHA 24TH @ HICKORY | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1994 | -- | 190.0 | 999.1 | Good | 62.0 | U182505510 |
NBI report Bridgehunter | 36TH STREET | UPRR 816-824-G | OMAHA 36TH @ D | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1994 | -- | 123.0 | 735.9 | Good | 44.2 | U182505315 |
NBI report | COLL 7947/252ND | STREAM | 1W 3N OF WATERLOO | Concrete Slab (3 spans) | -- | 1994 | -- | 47.9 | 122.1 | Fair | 93.6 | C002801725 |
NBI report | EB-CD TO EB-I80 #5 | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 101.1 | 226.1 | Good | 85.0 | S080 44577 |
NBI report | EB-CDN TO I680 BR4 | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 95.1 | 212.0 | Good | 86.8 | S080 44576 |
NBI report | EB-I80 BRG# 2E | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | -- | 89.9 | 194.9 | Fair | 85.0 | S080 44574R |
NBI report | I80 | LITTLE PAPIO CR | IN OMAHA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1994 | -- | 106.0 | 384.9 | Fair | 85.0 | S080 44984 |
NBI report | N64 | PLATTE RIVER | 3W VALLEY | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1994 | -- | 143.1 | 992.2 | Good | 80.0 | S064 05295 |
NBI report | OLD MPL RD/FAU5154 | BIG PAPILLION CREEK | 118TH & MAPLE ST | Prestressed Tee beam (3 spans) | -- | 1994 | -- | 55.1 | 149.0 | Good | 88.8 | U1825K1435 |
NBI report | NB-I680 BRG#6 | I80/SBCD-E/RP10-11 WBCD | I80/I680 INTRCHG | Steel Stringer/Multi-beam or girder (9 spans) | -- | 1994 | 2015 | 159.1 | 1140.1 | Good | 94.0 | S680 00017R |
NBI report | WB-I80 BRG #2W | UPRR 815-672-J | IN OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1994 | 2015 | 89.9 | 194.9 | Good | 85.0 | S080 44574L |
NBI report | 10TH ST/FAU 5103 | I80/EB AND WB RAMPS | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 147.0 | 285.1 | Good | 79.2 | S080 45433 |
NBI report | 156TH ST | US6/W DODGE RD | 156TH @ W DODGE OMAHA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 64.0 | 130.9 | Fair | 84.0 | S006 36093 |
NBI report | AMES ST | ROAD DITCH | .5N W MAPLE RD/168TH ST | Concrete Culvert (3 spans) | -- | 1995 | -- | 6.9 | 22.0 | Good | 88.7 | U182521415P |
NBI report | ANDERSON AVE | STREAM | NE EDGE MILLARD AIRPORT | Concrete Culvert (3 spans) | -- | 1995 | -- | 9.8 | 32.2 | Good | 77.7 | U182503705P |
NBI report | ANDERSON AVE | STREAM | NE EDGE MILLARD AIRPORT | Concrete Culvert (3 spans) | -- | 1995 | -- | 8.9 | 27.9 | Good | 77.7 | U182503710P |
NBI report | EB-I80 BRG #7E | SB-CD EAST & RAMP #10 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1995 | -- | 120.1 | 219.2 | Fair | 85.0 | S080 44606R |
NBI report | F ST/FAU 5030 | BNSF RR 074-707-J | OMAHA F @ 34TH | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1995 | -- | 71.9 | 144.0 | Good | 68.6 | U182542615 |
NBI report | F ST/FAU 5030 | BNSF RR 074-708-R | OMAHA F @ DAHLMAN | Steel Stringer/Multi-beam or girder | -- | 1995 | -- | 45.9 | 46.9 | Good | 68.6 | U182542620 |
NBI report | FORT STREET | W BR PAPILLION CREEK | 172ND & FORT ST | Prestressed Tee beam (3 spans) | -- | 1995 | -- | 34.1 | 103.0 | Good | 99.7 | C002821415 |
NBI report | WB-I80 TO NB-680 | N38/WEST CENTER ROAD | I680/N38 INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1995 | -- | 127.0 | 212.0 | Good | 93.2 | S680 00083A |
NBI report | WB-I80 BRG #7W | SB-CD EAST & RAMP 10 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1995 | 2015 | 120.1 | 219.2 | Good | 85.0 | S080 44606L |
NBI report | 13TH ST/FAU 5121 | I80 | 13TH ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1996 | -- | 140.1 | 279.9 | Good | 81.3 | S080 45413 |
NBI report | 144TH ST/FAU 5001 | W BR PAPILLION CREEK | 144TH @ F ST | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 71.9 | 186.0 | Good | 80.9 | U182503505R |
NBI report | 78TH STREET | STREAM | JCT N133/L-28K 1E .4N | Concrete Culvert (2 spans) | -- | 1996 | -- | 9.8 | 21.0 | Good | 83.3 | U182514510P |
NBI report Bridgehunter | 96TH ST/FAU 5017 | UPRR 816-830-K | OMAHA 96TH @ F | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 89.9 | 222.1 | Good | 69.7 | U182504305 |
NBI report | BLONDO ST/FAU 5066 | I680 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1996 | -- | 140.1 | 265.1 | Good | 78.1 | S680 00402 |
NBI report | REDICK AVE/FAU5088 | COLE CREEK | REDICK AVE @ 65TH ST | Concrete Culvert (3 spans) | -- | 1996 | -- | 9.8 | 33.1 | Good | 57.8 | U1825D1215 |
NBI report | SB-CD RD BRG #12 | N38 | CENTER ST INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1996 | -- | 127.0 | 206.0 | Good | 98.0 | S680 00083B |
NBI report | VANE STREET | STREAM | .1E 78TH ST ON VANE ST | Concrete Culvert (2 spans) | -- | 1996 | -- | 9.8 | 21.0 | Good | 88.4 | U182514515P |
NBI report | WB-CD ROAD BRG #8 | SB-CD EAST-RMPS 5-10-11 | IN OMAHA | Steel Stringer/Multi-beam or girder (6 spans) | -- | 1996 | -- | 182.1 | 1008.9 | Fair | 97.0 | S080 44602 |
NBI report | OLD LINCOLN HWY | W BR PAPILLION CREEK | 1.7E OF ELKHORN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1996 | 1997 | 80.1 | 123.0 | Fair | 86.9 | C002811805P |
NBI report | I680 BRG#13N&S | N38 | CENTER ST INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1996 | 2008 | 127.0 | 209.0 | Good | 98.0 | S680 00083 |
NBI report | 168TH ST/FAS 3811 | W BR PAPILLION CREEK | .3N 168TH & N64 | Prestressed Tee beam (3 spans) | -- | 1997 | -- | 44.0 | 131.9 | Good | 65.8 | U182513125 |
NBI report | N36 | RAWHIDE CREEK | 4W ELK CITY | Prestressed Tee beam (3 spans) | -- | 1997 | -- | 37.1 | 111.9 | Fair | 92.1 | S036 00535 |
NBI report | PRIVATE DRIVE | STREAM | 37TH ST. S OF MCKINLEY | Concrete Culvert (2 spans) | -- | 1997 | -- | 14.1 | 28.9 | Good | 88.6 | U1825H5155 |
NBI report | PRKING LOT ENT/EXT | DRAINAGE WAY | .1W 153 ST/.2N BLONDO ST | Concrete Culvert | -- | 1997 | -- | 6.9 | 23.0 | Good | 88.7 | C002843315P |
NBI report | 180TH ST | STREAM | .18S OF US6 & 180TH ST | Concrete Culvert (2 spans) | -- | 1997 | 2005 | 9.8 | 22.0 | Fair | 57.7 | C002812905 |
NBI report | SB-I680 BRG #11 | SBCD-EAST | I80/I680 INTRCHG | Steel Stringer/Multi-beam or girder | -- | 1997 | 2015 | 154.9 | 160.1 | Good | 98.0 | S680 00017L |
NBI report | 108TH ST | STREAM | 1.3N 108TH & N36 | Concrete Culvert (3 spans) | -- | 1998 | -- | 9.8 | 35.1 | Good | 88.6 | C002824105 |
NBI report | 149TH ST | PAPILLION CREEK | 245' SOUTH OF "B | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 79.1 | 233.9 | Good | 98.8 | U182503010P |
NBI report | 156TH ST/FAS 3805 | STREAM | JCT N36/S-28F 2.7S | Concrete Culvert (2 spans) | -- | 1998 | -- | 12.1 | 28.9 | Good | 78.9 | C002813315 |
NBI report | 16TH ST/FAU 5095 | UP/BNSF RR 816-755-B | OMAHA 16TH @ MASON | Prestressed Stringer/Multi-beam or girder (10 spans) | -- | 1998 | -- | 128.0 | 1253.0 | Good | 66.3 | U1825J5505 |
NBI report | 63RD ST | STREAM | 63RD @ F ST | Concrete Culvert (2 spans) | -- | 1998 | -- | 9.8 | 21.0 | Good | 86.8 | U1825D4725 |
NBI report | COLL 7938 | US275 | .25E VALLEY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1998 | -- | 152.9 | 308.1 | Good | 77.0 | S275 16407 |
NBI report | COUNTY HIGHWAY | US275 | 2NW VALLEY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1998 | -- | 125.0 | 250.0 | Good | 99.9 | S275 16065 |
NBI report | DUTCH HALL ROAD | KNIGHT CREEK | 2E N133 WASHINGTON CL | Prestressed Tee beam (3 spans) | -- | 1998 | -- | 40.0 | 102.0 | Good | 97.7 | U182520260 |
NBI report | MASON STREET | UPRR | OMAHA MASON @ 16TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 89.9 | 289.1 | Good | 93.2 | U1825Q2005 |
NBI report | N133 | I680 | N133/I680 INTRCHG | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1998 | -- | 104.0 | 210.0 | Good | 100.0 | S680 00713 |
NBI report | N64 | US275 | 1N VALLEY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1998 | -- | 103.0 | 208.0 | Fair | 100.0 | S064 05635 |
NBI report | NB US275 | N36 | 4NW VALLEY | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 128.0 | 129.9 | Fair | 100.0 | S275 15848L |
NBI report | NB US275 & RAMP | PLATTE RIVER FLOODWAY | .5E VALLEY | Concrete Slab (3 spans) | -- | 1998 | -- | 39.0 | 101.1 | Good | 85.0 | S275 16474L |
NBI report | NW CONNECTOR | THOMAS CREEK | IRVINGTON AREA | Concrete Slab (3 spans) | -- | 1998 | -- | 65.9 | 167.0 | Fair | 85.0 | C002841205P |
NBI report | OLD LINCOLN HWY | W BR PAPILLION CREEK | OLD LINCLN HWY W OF 192ND | Concrete Slab (3 spans) | -- | 1998 | -- | 42.0 | 107.0 | Good | 95.0 | U182501605P |
NBI report | PINE STREET | LITTLE PAPILLION CREEK | OMAHA PINE @ 69TH | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1998 | -- | 62.0 | 170.9 | Good | 84.1 | U1825E2225 |
NBI report | SB US275 | N36 | 4NW VALLEY | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 128.0 | 129.9 | Fair | 100.0 | S275 15848R |
NBI report | SB US275 & RAMP | PLATTE RIVER FLOODWAY | .5E VALLEY | Concrete Slab (3 spans) | -- | 1998 | -- | 39.0 | 101.1 | Good | 99.0 | S275 16474R |
NBI report | VALLEY EAST CONECT | US275 | .5E VALLEY | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1998 | -- | 91.9 | 185.0 | Fair | 100.0 | S275 16499 |
NBI report | 168TH STREET | PAPIO CREEK | 1W 2N OF BENNINGTON | Prestressed Tee beam (3 spans) | -- | 1999 | -- | 40.0 | 122.1 | Good | 99.8 | C002813145 |
NBI report | BLONDO ST/FAU 5066 | BIG PAPILLION CREEK | JCT I680/US6 1N .8W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 71.9 | 217.9 | Good | 84.0 | U182521825 |
NBI report | CITY STREET | BIG PAPILLION CREEK TRIB | .25S .2E 120 & W MAPL | Prestressed Tee beam (3 spans) | -- | 1999 | -- | 49.9 | 129.9 | Good | 97.9 | U182513908P |
NBI report Bridgehunter | DAHLMAN AVE | UPRR 816-823-A | OMAHA DAHLMAN @ A | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 73.2 | 191.0 | Good | 77.9 | U1825E5315 |
NBI report | FORT STREET | STREAM | 184TH & FORT ST | Concrete Culvert (3 spans) | -- | 1999 | -- | 9.8 | 37.1 | Good | 88.6 | C002821410 |
NBI report | G STREET | STREAM | 200' W OF 178TH ST | Concrete Culvert (3 spans) | -- | 1999 | -- | 7.9 | 27.9 | Good | 88.7 | C002802903P |
NBI report | RAINWOOD ROAD | W BR PAPILLION CREEK | 194TH & RAINWOOD RD | Concrete Culvert (3 spans) | -- | 1999 | -- | 12.1 | 44.9 | Good | 88.3 | C002820815 |
NBI report | RAMP US275 TO US6 | BOX ELDER CREEK | 3W WCL OMAHA | Concrete Culvert (3 spans) | -- | 1999 | -- | 12.1 | 39.0 | Fair | 72.7 | S275 17369A |
NBI report | RAMP US6 TO US275 | BOX ELDER CREEK | 3W WCL OMAHA | Concrete Culvert (3 spans) | -- | 1999 | -- | 12.1 | 40.0 | Fair | 62.7 | S275 17369B |
NBI report | US275 | BOX ELDER CREEK | 3W WCL OMAHA | Concrete Culvert (2 spans) | -- | 1999 | -- | 16.1 | 33.1 | Fair | 72.7 | S275 17369 |
NBI report | US6/N31 | BOX ELDER CREEK | 5S ELKHORN | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 112.9 | 116.1 | Good | 85.0 | S006 35482 |
NBI report | US6/N31 | US275/N92 | US6/US275 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 137.1 | 139.1 | Good | 85.0 | S006 35500 |
NBI report | 10TH ST/FAU 5103 | BNSF/UPRR/5044 074-686-T | OMAHA 10TH @ LEAVENWORTH | Steel Stringer/Multi-beam or girder (13 spans) | -- | 2000 | -- | 134.8 | 1321.9 | Good | 80.1 | U1825Q5505 |
NBI report | 156TH ST/FAS 3805 | BIG PAPILLION CREEK | JCT N36/S-28F .7S | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2000 | -- | 67.9 | 182.1 | Fair | 74.5 | C002813320 |
NBI report | 159TH ST | RUSSELL CREEK | 159TH @ IDA ST | Concrete Slab (2 spans) | -- | 2000 | -- | 35.1 | 69.9 | Fair | 99.0 | C002813115P |
NBI report | 168TH ST | US6/WEST DODGE ROAD | 1.7W OMAHA | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2000 | -- | 65.9 | 133.9 | Fair | 98.0 | S006 35981 |
NBI report | 168TH ST/FAU 5131 | W PAPPILLION CRK & U | JCT 168TH ST/US6 .3N | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2000 | -- | 130.9 | 470.2 | Good | 82.1 | U182512905P |
NBI report | CNTY HIGHWAY | STREAM | 4N 4W VALLEY | Concrete Culvert (2 spans) | -- | 2000 | -- | 7.9 | 22.0 | Good | 57.8 | S275 15787 |
NBI report | IDA STREET | RUSSELL CREEK | IDA @ 156TH STREET | Concrete Culvert (2 spans) | -- | 2000 | -- | 15.1 | 32.2 | Fair | 83.8 | C002811210 |
NBI report | ISLAND ROAD | BENNINGTON LAKE (WEST) | BENGTN LAKE RD .25E 180TH | Prestressed Stringer/Multi-beam or girder | -- | 2000 | -- | 104.0 | 105.0 | Good | 91.8 | C002820410P |
NBI report | MAIN ST/COLL 5169 | WEST PAPILLION CREEK | ELKHORN MAIN @ RAILROAD | Steel Girder and floorbeam system (3 spans) | -- | 2000 | -- | 25.9 | 66.9 | Good | 89.6 | U182501805P |
NBI report | US6 | UPRR 816-858-B | NJCT US6/N31 3.2E | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2000 | -- | 94.2 | 268.1 | Good | 85.0 | S006 35999 |
NBI report | US6 | WEST PAPILLION CREEK | 1.3W OMAHA | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2000 | -- | 121.1 | 315.0 | Good | 85.0 | S006 36012 |
NBI report | Y STREET | HELL CREEK | Y ST @ 115TH ST | Prestressed Tee beam (3 spans) | -- | 2000 | -- | 42.0 | 123.0 | Good | 99.7 | U182512625P |
NBI report | BURT STREET | STREAM | BURT ST WEST OF 174 ST. | Concrete Culvert (2 spans) | -- | 2001 | -- | 12.1 | 24.9 | Fair | 88.8 | C002812903P |
NBI report | EB-US6 TO NB-I680 | I680 | DODGE ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 141.1 | 254.9 | Good | 100.0 | S680 00289 |
NBI report | MEIGS ST | UPRR/REICHMAN RD | SECL VALLEY | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2001 | -- | 110.9 | 421.9 | Good | 96.1 | M250001415 |
NBI report | N 48TH STREET | STREAM | N 48TH @ MORMAN BRG ROAD | Concrete Culvert (2 spans) | -- | 2001 | -- | 8.9 | 25.9 | Fair | 88.4 | U182525140 |
NBI report | N64 | OLD US275/UPRR | IN VALLEY | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 111.9 | 226.1 | Good | 88.3 | S064 05561 |
NBI report | NB680 TO WB US6 | I680/RMP1/RMP2/SB CD RD | DODGE ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 158.1 | 305.1 | Good | 95.0 | S680 00315 |
NBI report | SORENSON PARKWAY | KNIGHT CREEK | .1W WENNINGHOFF ROAD | Concrete Slab (3 spans) | -- | 2001 | -- | 57.1 | 146.0 | Fair | 85.0 | C002841207P |
NBI report | SORENSON PARKWAY | STREAM | .1E WENNINGHOFF ROAD | Concrete Culvert (3 spans) | -- | 2001 | -- | 12.1 | 59.1 | Fair | 57.7 | C002841215P |
NBI report | US6 | I680 DIRECTIONAL RAMPS | I680/US6 INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 95.1 | 189.0 | Good | 83.0 | S680 00302A |
NBI report | WB US6 TO SB I680 | I680/SB CD ROAD | DODGE ST INTRCHG | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 128.9 | 246.1 | Good | 100.0 | S680 00304 |
NBI report | 39TH STREET | BNSF RR 074-716-H | OMAHA 39TH @ O | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 118.1 | 118.1 | Good | 87.7 | U1825J5105 |
NBI report | BLONDO STREET | STREAM | .5S OF WATERLOO | Concrete Culvert (3 spans) | -- | 2002 | -- | 9.8 | 32.2 | Good | 88.6 | C002801805 |
NBI report | MORM BR RD/FAU5047 | MILL CREEK | JCT US73/N36 .1W .1S | Concrete Culvert (3 spans) | -- | 2002 | -- | 12.1 | 51.8 | Fair | 70.0 | U1825A5150 |
NBI report | READ STREET | STREAM | .15 W OF N122ND ON READ | Concrete Culvert (2 spans) | -- | 2002 | -- | 9.8 | 21.0 | Good | 88.0 | C002813720P |
NBI report | SKYLINE DRIVE | SL28B/W DODGE RD | IN ELKORN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2002 | -- | 125.0 | 215.9 | Fair | 99.2 | SL28B00216 |
NBI report | US6 | STREAM | .35E JCT US6/N31 | Concrete Culvert (2 spans) | -- | 2002 | -- | 9.8 | 20.0 | Good | 70.0 | S006 35728 |
NBI report | US6 EB | N31 | US6/L28B/N31 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 207.0 | 208.0 | Good | 85.0 | S006 35693R |
NBI report | US6 WB | N31 | US6/L28B/N31 INTCHG | Prestressed Stringer/Multi-beam or girder | -- | 2002 | -- | 207.0 | 208.0 | Good | 85.0 | S006 35693L |
NBI report | 148TH ST. | STREAM | .1MI E OF NEBRASKA AVE | Concrete Culvert (3 spans) | -- | 2003 | -- | 7.9 | 24.9 | Fair | 83.4 | C002813307P |
NBI report | 180TH STREET | US6 | 180TH ST.& US6 OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 66.9 | 136.2 | Good | 81.0 | S006 35890 |
NBI report | ABBOT DR. OMAHA | BNSF RR | ABBOT DR EAST OF 13TH ST. | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 179.1 | 356.0 | Good | 65.5 | U1825B4710 |
NBI report | DEER CREEK DRIVE | STREAM | .2W OF N 120TH ON DEER CR | Concrete Culvert (2 spans) | -- | 2003 | -- | 9.8 | 21.0 | Good | 88.0 | C002813725P |
NBI report | EB-N64 | I680 | MAPLE ST INTRCHG | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 124.0 | 251.0 | Good | 98.0 | S680 00459 |
NBI report | F ST | STREAM | 195TH & F ST | Concrete Culvert (2 spans) | -- | 2003 | -- | 12.1 | 24.9 | Good | 85.0 | C002822615 |
NBI report | F ST. | STREAM | .4MI EAST OF 204TH ST. | Concrete Culvert (2 spans) | -- | 2003 | -- | 15.1 | 29.9 | Good | 88.5 | C002822613 |
NBI report | N133 | THOMAS CREEK | 1NW NWCL OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 83.0 | 220.2 | Fair | 85.0 | S133 00591L |
NBI report | N133 | THOMAS CREEK | 1NW NWCL OMAHA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2003 | -- | 83.0 | 220.2 | Good | 85.0 | S133 00591R |
NBI report | RAINWOOD ROAD | THOMAS CREEK | 114TH & RAINWOOD DR | Prestressed Stringer/Multi-beam or girder | -- | 2003 | -- | 115.2 | 117.1 | Good | 99.3 | C002830825 |
NBI report | REYNOLDS STREET | STREAM | EAST OF N155TH | Concrete Culvert (3 spans) | -- | 2003 | -- | 8.9 | 27.9 | Good | 83.4 | C002813313P |
NBI report | SHEFFIELD DR. | STREAM | .04 E OF 155TH ST. | Concrete Culvert (3 spans) | -- | 2003 | -- | 8.9 | 27.9 | Good | 83.4 | C002813311P |
NBI report | SPRAGUE ST | I680 | IN OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 97.1 | 195.9 | Good | 87.5 | S680 00532 |
NBI report | US6 | 192ND STREET | US6 AT 192ND ST. OMAHA | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 61.0 | 123.0 | Good | 84.0 | S006 35790 |
NBI report | US6 | STREAM | .2E 180TH&US6 OMAHA | Concrete Culvert (3 spans) | -- | 2003 | -- | 9.8 | 32.2 | Fair | 70.0 | S006 35912 |
NBI report | 228TH ST. | SL28B | IN ELKHORN | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2004 | -- | 120.1 | 242.1 | Good | 99.2 | SL28B00119 |
NBI report | COUNTY HIGHWAY | US275 | 2W ELKHORN | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2004 | -- | 120.1 | 242.1 | Good | 99.0 | S275 16755 |
NBI report | EB EXPRESSWAY | CITY STREET'S | WEST DODGE RD OMAHA | Prestressed Stringer/Multi-beam or girder (39 spans) | -- | 2004 | -- | 198.2 | 5402.2 | Good | 79.0 | S006 36428A |
NBI report | EB L28B | ELKHORN RIVER OVERFLOW | 1W 1S ELKHORN | Concrete Slab (3 spans) | -- | 2004 | -- | 37.1 | 92.9 | Good | 84.9 | SL28B00093R |
NBI report | GROVER STREET | BOXELDER CREEK TRIB | .25 W OF 192ND STREET | Concrete Culvert (3 spans) | -- | 2004 | -- | 8.9 | 29.9 | Good | 88.0 | C002802505P |
NBI report | L STREET | BOXELDER CREEK TRIB | .1E OF 194 AVE ON L ST | Steel Culvert (2 spans) | -- | 2004 | -- | 16.1 | 34.1 | Good | 98.8 | C002802480P |
NBI report | L STREET | BOXELDER CREEK TRIB | .1 E OF 194TH AVE ON L ST | Steel Culvert | -- | 2004 | -- | 17.1 | 21.0 | Fair | 98.8 | C002802490P |
NBI report | N BRDG RD/FAU5011 | BIG PAPILLION CREEK | N BRIDGE RD @ 111TH ST | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 100.1 | 259.9 | Good | 85.0 | U1825R1805 |
NBI report | N38/W CENTER RD | 72ND ST | 72ND & WEST CENTER OMAHA | Prestressed Tee beam (2 spans) | -- | 2004 | -- | 83.0 | 83.0 | Good | 79.9 | U182500685 |
NBI report | RAMP 30 OVER PAPIO | BIG PAPILLION CREEK | WEST DODGE EXPRESSWAY | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 146.0 | 400.0 | Good | 68.0 | S006 36466A |
NBI report | RAMP-L28B | L28B | 2W 1S ELKHORN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2004 | -- | 176.8 | 337.0 | Good | 83.9 | SL28B00048 |
NBI report | RMP L28B | L28B | 2W 1S ELKHORN | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2004 | -- | 176.8 | 332.0 | Fair | 98.0 | S275 16840 |
NBI report | WB EXPRESWAY | CITY STREET'S | WEST DODGE RD OMAHA | Prestressed Stringer/Multi-beam or girder (40 spans) | -- | 2004 | -- | 170.0 | 5216.1 | Good | 79.0 | S006 36428B |
NBI report | WB L28B | ELKHORN RIVER OVERFLOW | 1W 1S ELKHORN | Concrete Slab (3 spans) | -- | 2004 | -- | 37.1 | 92.9 | Fair | 84.9 | SL28B00093L |
NBI report | 179 TH STREET | STREAM | 179TH & CHICAGO | Concrete Culvert (2 spans) | -- | 2005 | -- | 14.8 | 29.2 | Good | 100.0 | C002812901P |
NBI report | BURKE ST. | OLD LINCOLN HIGHWAY CR | 450' W OF 180TH & BURKE | Concrete Culvert (2 spans) | -- | 2005 | -- | 12.1 | 24.9 | Good | 99.8 | C002802850P |
NBI report Bridgehunter | DUTCH HALL ROAD | THOMAS CREEK | 1W N133 WASHINGTON CL | Prestressed Tee beam | -- | 2005 | -- | 69.9 | 71.9 | Good | 94.6 | C002820255 |
NBI report | EB BRG OVR 108TH | 108TH ST | 108TH & DODGE BRG#9 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 87.9 | 169.0 | Good | 82.0 | S006 36484A |
NBI report | G STREET | BOXELDER CREEK TRIB | 200' E OF 200TH ST & G ST | Concrete Culvert (3 spans) | -- | 2005 | -- | 9.8 | 43.0 | Good | 99.9 | C002802495P |
NBI report | MILITARY ROAD | STREAM | MILITARY ROAD AND IDA ST | Concrete Culvert (2 spans) | -- | 2005 | -- | 12.1 | 29.9 | Fair | 57.7 | C002831210P |
NBI report | N92 | PLATTE RIVER | 2E YUTAN | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2005 | -- | 174.9 | 972.2 | Fair | 80.0 | S092 46256L |
NBI report | N92 | PLATTE RIVER | 2E YUTAN | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2005 | -- | 165.0 | 594.2 | Fair | 80.0 | S092 46282L |
NBI report | NB-US75 | I480 EB & WB | US75 NB OVER 480 OMAHA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2005 | -- | 130.9 | 436.0 | Good | 81.3 | S075 09076 |
NBI report | NB-US75 | WB-I480 TO NB-US75 RMP | 28TH & DODGE INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2005 | -- | 138.1 | 291.0 | Good | 81.3 | S075 09084 |
NBI report | NB-US75 | BURT ST/FAU 5110 | US75/FAU 5110 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 124.0 | 125.0 | Good | 82.0 | S075 09102C |
NBI report | NB-US75 | BURT ST/FAU5110 | US75/FAU 5110 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 124.0 | 126.0 | Good | 82.0 | S075 09102D |
NBI report | NB-US75 | N64R/CUMING ST | US75/N64 INTRCHG | Prestressed Tee beam (3 spans) | -- | 2005 | -- | 74.2 | 158.1 | Good | 84.0 | S075 09109R |
NBI report | ORCHARD AVE | BOXELDER CREEK TRIB | .02E OF 196TH ON ORCHARD | Steel Culvert (2 spans) | -- | 2005 | -- | 16.1 | 34.1 | Fair | 87.5 | C002802470P |
NBI report | RMP 40 BRG#7 | 108TH ST | 108TH & DODGE | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 92.9 | 172.9 | Good | 64.0 | S006 36484D |
NBI report | SB-US75TOEB 480 | T480/US75/RAMPS | 28TH & DODGE INTRCHG | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2005 | -- | 192.9 | 696.9 | Good | 84.0 | S480 00247A |
NBI report | US75/CUMING ST EXT | BURT ST/FAU 5110 | US75/FAU 5110 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 124.0 | 126.0 | Good | 99.0 | S075 09102A |
NBI report | WB US6 BRG#6 | 108TH ST | 108TH & DODGE | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 98.1 | 191.9 | Good | 66.0 | S006 36484B |
NBI report | WB-US6 BRG #8 | 108TH ST | 108TH & DODGE | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2005 | -- | 200.1 | 401.9 | Good | 66.0 | S006 36484C |
NBI report | WEBER STREET | STREAM | .03 W OF N75 ON WEBER ST. | Concrete Culvert (2 spans) | -- | 2005 | -- | 12.1 | 24.9 | Good | 88.6 | C002814520P |
NBI report | WEIR STREET | BOXELDER CREEK TRIB | .1E OF 197TH ON WEIR ST | Steel Culvert | -- | 2005 | -- | 23.0 | 23.0 | Good | 99.5 | C002802460P |
NBI report | WESTERN AVE | COLE CREEK | OMAHA WESTERN @ 77TH | Concrete Culvert | -- | 2005 | -- | 29.9 | 32.2 | Good | 80.5 | U1825H1810 |
NBI report | 156TH STREET | STREAM | 410' NORTH OF IDA ST. | Concrete Culvert (2 spans) | -- | 2006 | -- | 13.1 | 25.9 | Good | 72.9 | C002813310 |
NBI report | BONDESSON ST | STREAM | .1W OF 168TH STREET | Concrete Culvert (2 spans) | -- | 2006 | -- | 12.1 | 29.9 | Good | 88.6 | C002821025P |
NBI report | NO H.W.S. CLEV BLV | STREAM | 1275' SOUTH OF FORT S | Concrete Slab (3 spans) | -- | 2006 | -- | 56.1 | 140.1 | Fair | 97.9 | C002821413P |
NBI report | PEDESTRIAN OVRPASS | 42ND STREET | .3N 42ND & EMILE ST | Steel Truss - Thru | -- | 2006 | -- | 129.9 | -- | -- | -- | U1825G5118 |
NBI report | B.BOOZER FAU/5135 | STREAM | .5N 156TH & US275 | Concrete Arch - Deck | -- | 2007 | -- | 54.1 | 58.1 | Good | 73.7 | U1825N3115 |
NBI report | EB-I480 | 23RD/24TH FAU5083/5085 | IN OMAHA | Prestressed Tee beam (4 spans) | -- | 2007 | -- | 51.8 | 181.1 | Good | 83.0 | S480 00273R |
NBI report | READ ST | STREAM | .2M W OF WENNINGHOFF | Prestressed Stringer/Multi-beam or girder | -- | 2007 | -- | 82.0 | 83.0 | Fair | 99.6 | C002841212P |
NBI report | SB US75 OVER CUMIN | N64 /CUMING ST | US75/N64 INTRCHG | Prestressed Tee beam (3 spans) | -- | 2007 | -- | 74.2 | 158.1 | Good | 63.0 | S075 09109L |
NBI report | US75 I480 ACCESS | BURT ST/FAU 5110 | US75/FAU 5110 INTRCHG | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2007 | -- | 125.0 | 127.0 | Good | 85.0 | S075 09102B |
NBI report | US75SB RAMP OV BUR | BURT ST/FAU 5110 | US75/FAU 5110 INTRCHG | Prestressed Stringer/Multi-beam or girder | -- | 2007 | -- | 123.0 | 125.0 | Fair | 85.0 | S075 09102E |
NBI report | 186TH STREET | STREAM | .3S 186TH & RAINWOOD | Concrete Slab (3 spans) | -- | 2008 | -- | 24.0 | 63.3 | Good | 97.3 | C002802710P |
NBI report | CRAIG STREET | STREAM | 140' W WENNINGHOFF RD | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 89.9 | 89.9 | Good | 99.8 | C002841220P |
NBI report | GIBSON RD VIADUCT | BNSF RR | GIBSON RD & US275 OMAHA | Steel Stringer/Multi-beam or girder (4 spans) | -- | 2008 | -- | 220.2 | 788.1 | Good | 94.5 | U182530960 |
NBI report | PACIFIC ST/FAU5044 | I680 | PACIFIC ST INTRCHG | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2008 | -- | 98.1 | 195.9 | Good | 83.0 | S680 00184 |
NBI report | RIVERVIEW BLVD | I80 | IN OMAHA | Prestressed Stringer/Multi-beam or girder | -- | 2008 | -- | 182.1 | 184.1 | Good | 97.3 | S080 45461 |
NBI report | SB-US75 | I480 CHICAGO ST EXIT | 28TH & DODGE INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 136.2 | 310.1 | Good | 82.0 | S075 09074 |
NBI report | SB-US75 | N64 | US75/N64 INTRCHG | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 126.0 | 530.9 | Good | 83.0 | S075 09106 |
NBI report | SEWARD STREET | COLE CREEK | SEWARD ST& COLE CR OMAHA | Concrete Culvert | -- | 2009 | -- | 29.9 | 30.8 | Good | 97.9 | U182522300 |
NBI report | WB-I480 | 23RD/24TH FAU5083/5085 | IN OMAHA | Prestressed Tee beam (4 spans) | -- | 2009 | -- | 51.8 | 182.1 | Good | 83.0 | S480 00273L |
NBI report | I-80 WB | BNSF/MO R | ECL OMAHA | Steel Girder and floorbeam system (4 spans) | -- | 2010 | -- | 424.9 | 2483.1 | Good | 75.0 | S080 45531L |
NBI report | PAWNEE ROAD | THOMAS CREEK | JCT N36/N133 1N .8E | Prestressed Stringer/Multi-beam or girder | -- | 2010 | -- | 85.0 | 86.9 | Good | 99.9 | C002800405 |
NBI report | RINGWOOD ROAD | STREAM | 2NE OF VALLEY | Concrete Slab (3 spans) | -- | 2010 | -- | 25.9 | 65.0 | Good | 99.7 | C002800805 |
NBI report | UPRR | UPRR 815-676-L | 1E WCL OMAHA | Steel Stringer/Multi-beam or girder | -- | 2010 | -- | 129.9 | -- | -- | -- | U182500022 |
NBI report Bridgehunter | US275/N92 | BNSF/ST/MO R 074-670-W | ECL OMAHA | Steel Truss - Thru | -- | 2010 | -- | 624.0 | 4300.1 | Good | 71.0 | S275 19041 |
NBI report Bridgehunter | WEST MAPLE ROAD | STREAM | 1SW OF VALLEY | Metal Culvert (2 spans) | -- | 2011 | -- | 32.2 | 76.1 | Good | 99.7 | C002801605 |
NBI report | 228TH ST/COLL 7941 | DITCH | .5E 1.2N OF WATERLOO | Metal Culvert (2 spans) | -- | 2012 | -- | 27.9 | 65.9 | Fair | 98.7 | C002812105 |
NBI report | STATE ST | STREAM | 207TH & STATE ST | Concrete Culvert (2 spans) | -- | 2014 | -- | 13.1 | 26.9 | Good | 99.8 | C002821015 |
NBI report | Q ST/FAS 3795 | STREAM | WJCT US275/N92 2S .7W | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2015 | -- | 65.0 | 165.0 | Good | 73.6 | C002802805 |
NBI report | 208TH STREET | BOXELDER CREEK TRIB | 300' S OF BLUE SAGE P | Steel Culvert | -- | 2016 | -- | 25.3 | 25.3 | Good | 99.9 | C002820422 |
NBI report | BLUE SAGE PKWY | BOXELDER CREEK TRIB | 900' W OF 204TH ST | Steel Culvert | -- | 2016 | -- | 22.0 | 22.0 | Good | 95.6 | C002820424 |
NBI report | DUTCH HALL ROAD | STREAM | 7W N31 DODGE CL | Concrete Culvert (3 spans) | -- | 2016 | -- | 8.9 | 29.9 | Good | 99.6 | C002810205 |
NBI report | HWS CLEVELAND BLVD | STREAM | 350' E OF 180TH ST | Prestressed Stringer/Multi-beam or girder | -- | 2016 | -- | 82.4 | 82.4 | Good | 100.0 | C002820426 |
NBI report | MARINDA STREET | BOXELDER CREEK TRIB | 208' WEST OF 208TH ST | Prestressed Stringer/Multi-beam or girder | -- | 2016 | -- | 76.1 | 76.1 | Good | 99.9 | C002820420 |
NBI report | N36 | RAWHIDE CREEK TRIBUTARY | 5W ELK CITY | Concrete Culvert (3 spans) | -- | 2017 | -- | 13.1 | 41.0 | Good | 92.1 | S036 00429 |
NBI report | N92 | PLATTE R TRIB/OVERFLOW | 3E YUTAN | Concrete Culvert (4 spans) | -- | 2017 | -- | 12.8 | 53.5 | Good | 84.0 | S092 46400 |
NBI report | Q ST/FAU 5026 | BNSF RR 074-717-P | OMAHA Q @ 42ND | Prestressed Stringer/Multi-beam or girder | -- | 2017 | -- | 80.1 | 80.1 | Good | 85.0 | U182522835 |
NBI report | N85 | BNSF RR 073-047-W | SCL OMAHA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2018 | -- | 120.1 | 339.9 | Poor | 55.0 | S085 00402 |