Thomas County

CarriesCrossesLocationDesignStatusYear BuiltYear Recon.Span Len.Total Len.ConditionSuff. RatingID
NBI reportCOUNTY HIGHWAYMIDDLE LOUP RIVER1.2E OF THEDFORDWood Stringer/Multi-beam or girder (2 spans)--1935--24.951.8Poor21.0C008603105P
NBI reportSCENIC OVERLOOK RDDISMAL RIVER15S THEDFORDConcrete Slab (3 spans)--1951--41.0101.1Fair84.8S083 13344R
NBI reportS86B NAT'L FORESTMIDDLE LOUP RIVER1SW HALSEYConcrete Slab (3 spans)--1952--29.974.2Fair43.7SS86B00021
NBI reportCOLL 7315MIDDLE LOUP RIVER3E OF THEDFORDWood Stringer/Multi-beam or girder (3 spans)--1965--24.074.2Fair58.5C008603505P
NBI reportFDR 259MIDDLE LOUP RIVER1.3 MI. E. OF THEDFORDWood Stringer/Multi-beam or girder (3 spans)--1965--24.073.2Fair71.9020701000003001
NBI reportCOUNTY HIGHWAYDISMAL RIVER13S OF THEDFORDWood Stringer/Multi-beam or girder--1969--30.832.2Poor32.0C008604205P
NBI reportCOUNTY HIGHWAYMIDDLE LOUP RIVER.5W OF HALSEYSteel Stringer/Multi-beam or girder--1969199568.969.9Good87.2C008615905
NBI reportUS83DISMAL RIVER15S THEDFORDSteel Stringer/Multi-beam or girder (3 spans)--1979--110.9288.1Good91.9S083 13350
NBI reportN2MIDDLE LOUP RIVER7W THEDFORDPrestressed Tee beam (3 spans)--1992--46.9141.1Good80.0S002 20292
NBI reportN2BNSF RR 064-685-J7W THEDFORDSteel Stringer/Multi-beam or girder (3 spans)--1992--103.0253.0Good78.0S002 20305
NBI reportN2MIDDLE LOUP RIVER4W THEDFORDPrestressed Tee beam (2 spans)--1992--42.086.0Good80.0S002 20762
NBI reportN2MIDDLE LOUP RIVER2W THEDFORDPrestressed Tee beam (2 spans)--1992--42.086.0Good80.0S002 20906
NBI reportCOLL 7317MIDDLE LOUP RIVERSENECAPrestressed Tee beam (2 spans)--1993--35.171.9Good92.2C008600325
NBI reportFAS 1495DISMAL RIVERJCT N2/S-86A 13SSteel Stringer/Multi-beam or girder--1996--39.040.0Fair82.0C008600305
NBI reportCOUNTY HIGHWAYMIDDLE LOUP RIVER.2S OF THEDFORDSteel Stringer/Multi-beam or girder--2002--48.949.9Good89.6C008602905P
NBI reportCOUNTY HIGHWAYMIDDLE LOUP RIVER1E OF SENECASteel Stringer/Multi-beam or girder--2003--47.949.9Good96.2C008600805P
NBI reportCOUNTY HIGHWAYMIDDLE LOUP RIVER3W OF THEDFORDSteel Stringer/Multi-beam or girder--2004--58.160.0Fair87.2C008602305
NBI reportCOUNTY HIGHWAYDISMAL RIVER12S 3.7W OF THEDFORDSteel Stringer/Multi-beam or girder--2006--59.160.0Good92.0C008602105P
NBI reportTHEDFORD VIADUCTN 2 BNSF RRTHEDFORDPrestressed Stringer/Multi-beam or girder (2 spans)--2009--144.0288.1Good97.3S083 14810
NBI reportUS83MIDDLE LOUP RIVER0S THEDFORDPrestressed Stringer/Multi-beam or girder--2009--140.1143.1Good80.0S083 14787