Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | NFA A330 | DRY CREEK | .1MI SOUTH OF US70 | Concrete Arch - Deck (2 spans) | NR eligible | 1922 | -- | 44.9 | 106.0 | Poor | 25.7 | 210A2780003 |
NBI report | NFA A020 | HELTON CREEK | 6MI EAST OF SR53 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1934 | -- | 41.0 | 65.9 | Fair | 66.2 | 210A0630001 |
NBI report | FAS 264 | BRANCH | IN ALEXANDRIA CITY LIMITS | Concrete Slab (2 spans) | -- | 1940 | -- | 9.8 | 21.0 | Good | 74.0 | 21F00100007 |
NBI report | NFA A214 (SA 2107) | FALL CREEK | 1MI SOUTH OF US 70 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1945 | -- | 39.0 | 85.0 | Fair | 61.7 | 210A1630001 |
NBI report | NFA A219 (SA 2107) | PINE CREEK | 5 MI EAST OF SR56 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1945 | -- | 49.9 | 104.0 | Fair | 51.1 | 210A1670001 |
NBI report | FAS 141 | WOLF CREEK | NEAR E.EVINS STATE PARK | Concrete Tee beam | -- | 1946 | -- | 43.0 | 43.0 | Good | 66.7 | 21SR1410009 |
NBI report | FAS 141 | BRANCH | .4 MI.E.OF EVINS ST.PARK | Concrete Culvert (2 spans) | -- | 1946 | -- | 9.8 | 23.0 | Good | 86.5 | 21SR1410007 |
NBI report | FAS 141 | WOLF CREEK | 1 MI.W.OF CENTER HILL DAM | Concrete Tee beam | -- | 1946 | -- | 53.2 | 53.2 | Good | 62.6 | 21SR1410005 |
NBI report | FAS 141 | WOLF CREEK | NEAR E.EVINS STATE PARK | Concrete Tee beam | -- | 1946 | -- | 43.0 | 43.0 | Fair | 65.3 | 21SR1410011 |
NBI report | FAP 53 | SYCAMORE CREEK | DECALB-CANNON CO. LINE | Concrete Tee beam (3 spans) | -- | 1947 | -- | 43.0 | 100.1 | Fair | 78.1 | 21SR0530001 |
NBI report | FAS 146 | PINE CREEK | 2 MI.SW.OF SMITHVILLE | Concrete Culvert (2 spans) | -- | 1947 | -- | 12.1 | 25.9 | Good | 83.6 | 21SR1460001 |
NBI report | FAP 53 | SMITH FORK CREEK | IN LIBERTY CITY LIMITS | Concrete Tee beam (7 spans) | -- | 1948 | -- | 43.0 | 229.0 | Fair | 57.9 | 21SR0530005 |
NBI report | FAP 53 | GREEN HILL BRANCH | 1.25 MI. S.OF LIBERTY | Concrete Culvert (3 spans) | -- | 1948 | -- | 9.8 | 46.9 | Good | 89.2 | 21SR0530003 |
NBI report | FAS 96 | CENTER HILL DAM SPILLWAY | CENTER HILL DAM | Steel Girder and floorbeam system (8 spans) | -- | 1948 | 1984 | 51.5 | 485.9 | Fair | 79.6 | 21SR1410003 |
NBI report Bridgehunter | FAP 56 | CANEY FORK RIVER | AT PEDIGO RIDGE RD. | Steel Truss - Deck (4 spans) | -- | 1949 | 2013 | 387.2 | 1787.2 | Good | 79.3 | 21SR0560007 |
NBI report | FAS 141 | BRANCH | 4 MI. E. EVINS ST. PARK | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 23.0 | Good | 93.6 | 21SR1410013 |
NBI report | NFA A095 | HOLMES CREEK | 1MI NORTH OF SR56 | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 24.0 | 28.9 | Fair | 66.4 | 210A0770001 |
NBI report | NFA A282 | SINK CREEK | .56 MI WEST OF SR56 | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 38.1 | 39.0 | Fair | 62.3 | 210A2280001 |
NBI report | NFA A321 | DRY CREEK | 4MI WEST OF SR146 | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 24.0 | 25.9 | Fair | 18.5 | 210A2610001 |
NBI report | FAP 26 | FALL CREEK | IN SMITHVILLE | Concrete Culvert (3 spans) | -- | 1951 | -- | 15.1 | 68.9 | Fair | 76.5 | 21SR0260015 |
NBI report | NFA A548 | HICKMAN CREEK | CITY LIMITS OF ALEXANDRIA | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1951 | -- | 62.0 | 186.0 | Fair | 56.3 | 21SR0530007 |
NBI report | NFA A555 | SR 26 | IN THE CITY OF SMITHVILLE | Concrete Tee beam (4 spans) | -- | 1951 | -- | 41.0 | 141.1 | Fair | 71.8 | 21SR0260017 |
NBI report | FAP 26 | FALL CREEK | IN SMITHVILLE CITY LIMITS | Concrete Culvert (3 spans) | -- | 1951 | 1995 | 15.1 | 49.9 | Fair | 68.8 | 21SR0260019 |
NBI report | FAP 26 | BRANCH | IN LIBERTY CITY LIMITS | Concrete Culvert (2 spans) | -- | 1951 | 1995 | 12.1 | 28.2 | Good | 69.8 | 21SR0260023 |
NBI report | FAP 26 | BRANCH | NEAR THE SR-96 JCT. | Concrete Culvert (2 spans) | -- | 1953 | -- | 12.1 | 37.1 | Fair | 84.4 | 21SR0260005 |
NBI report | FAP 26 | HELTON CREEK | 1 MILE S. OF ALEXANDRIA | Concrete Culvert (3 spans) | -- | 1953 | -- | 12.1 | 41.0 | Fair | 82.4 | 21SR0260003 |
NBI report | FAP 26 | GOOSE CREEK | IN ALEXANDRIA CITY LIMITS | Concrete Tee beam (3 spans) | -- | 1953 | -- | 28.9 | 86.0 | Fair | 67.8 | 21SR0260001 |
NBI report | FAP 26 | BRANCH | IN LIBERTY CITY LIMITS | Concrete Culvert (2 spans) | -- | 1953 | 2004 | 12.1 | 25.9 | Good | 68.4 | 21SR0260009 |
NBI report | FAP 56 | SINK CREEK | 5.7 MI.S.OF SMITHVILLE | Concrete Tee beam (5 spans) | -- | 1954 | 1994 | 28.9 | 143.1 | Fair | 65.6 | 21SR0560001 |
NBI report | NFA A282 | WARREN COUNTY BRANCH | .5MI WEST OF SR56 | Steel Stringer/Multi-beam or girder | -- | 1960 | -- | 21.0 | 22.0 | Fair | 46.3 | 210A2280003 |
NBI report | NFA A455 | FALL CREEK | IN CITY OF SMITHVILLIE | Concrete Culvert (3 spans) | -- | 1960 | 1972 | 9.8 | 32.2 | Good | 96.9 | 210A2740001 |
NBI report | FAP 56 | PINE CREEK | 1.9 MI.S.OF SMITHVILLE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | -- | 45.9 | 136.2 | Good | 55.1 | 21SR0560003 |
NBI report | FAS 96 | WOLF CREEK | BUFFALO VALLEY RD | Concrete Culvert (2 spans) | -- | 1970 | -- | 12.1 | 26.9 | Good | 99.0 | 21SR0960009 |
NBI report | NFA 2025 (SA 2116) | GOOSE CREEK | 1MI SOUTHWEST OF US70 | Concrete Tee beam (2 spans) | -- | 1970 | -- | 18.0 | 38.1 | Good | 70.4 | 21020250001 |
NBI report | NFA 2195 (SA 2112) | BRANCH | 3.1 MI SOUTH OF US70 | Concrete Culvert (2 spans) | -- | 1970 | -- | 9.8 | 23.0 | Fair | 96.7 | 21021950003 |
NBI report | NFA 2195 (SA 2112) | EGYPT HOLLOW BRANCH | 2.5 MI SOUTH OF US70 | Concrete Culvert (3 spans) | -- | 1970 | -- | 9.8 | 32.2 | Good | 90.2 | 21021950001 |
NBI report | NFA A021 (SA 2124) | HANNAH BRANCH | 6MI EAST OF SR53 | Concrete Culvert (2 spans) | -- | 1970 | -- | 9.8 | 28.9 | Fair | 93.9 | 210A0480001 |
NBI report | NFA A320 | DRY CREEK | 7MI WEST OF SR146 | Steel Stringer/Multi-beam or girder | -- | 1970 | -- | 27.9 | 29.9 | Fair | 30.0 | 210A2920001 |
NBI report | FAP 56 | FALL CREEK | IN SMITHVILLE CITY LIMITS | Concrete Culvert (3 spans) | -- | 1971 | -- | 12.1 | 44.9 | Fair | 84.4 | 21SR0560005 |
NBI report | NFA 1118 (SA 2118) | HICKMAN BRANCH | .2MI NORTH OF US70 | Concrete Culvert (4 spans) | -- | 1972 | -- | 15.1 | 90.9 | Fair | 97.4 | 21S44280003 |
NBI report | NFA 1118 (SA 2118) | GOOSE CREEK | .3MI NORTH OF US70 | Concrete Culvert (4 spans) | -- | 1972 | -- | 12.1 | 51.8 | Good | 96.8 | 21F00090005 |
NBI report | NFA A381 | BRANCH | 1.5 KM N. OF US70 | Concrete Culvert (2 spans) | -- | 1972 | -- | 11.2 | 24.9 | Good | 79.7 | 210A3810001 |
NBI report | FAP 56 | CAPPY SPRINGS BRANCH | 1.6 MI.S.OF SHINING ROCK | Concrete Culvert (3 spans) | -- | 1975 | -- | 9.8 | 34.1 | Good | 81.6 | 21SR0560019 |
NBI report | FAS 141 | LONG BRANCH | 2 MI FM CENTER HILL DAM | Steel Culvert (3 spans) | -- | 1975 | -- | 5.9 | 24.9 | Fair | 92.5 | 21SR1410001 |
NBI report | NFA 2148 (SA 2119) | DRY BRANCH | .3 MI SOUTHWEST OF HELTON | Concrete Culvert (2 spans) | -- | 1975 | -- | 9.8 | 22.0 | Good | 97.7 | 21021480003 |
NBI report | NFA A472 | FALL CREEK | IN CITY OF SMITHVILLE | Concrete Culvert (2 spans) | -- | 1975 | -- | 12.1 | 25.9 | Good | 94.6 | 210A2710001 |
NBI report | NFA A293 | SINK CREEK | 1 MI NORTH OF WARREN CO. | Steel Stringer/Multi-beam or girder | -- | 1977 | -- | 24.9 | 25.9 | Fair | 81.5 | 210A2390001 |
NBI report | FAS 288 | SINK CREEK | 1.7 MI.S.W.OF SR056 | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1978 | -- | 88.9 | 176.8 | Fair | 65.1 | 21S43990001 |
NBI report | NFA A200 | FALL CREEK | .2 MI NORTH OF US70 | Concrete Culvert (3 spans) | -- | 1978 | -- | 15.1 | 47.9 | Good | 87.0 | 210A1240001 |
NBI report | NFA A028 | DRY CREEK | IN DOWELLTOWN | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1980 | -- | 38.1 | 116.1 | Fair | 83.9 | 210A0510003 |
NBI report | NFA A424 | BRAGER HOLLOW BRANCH | CURTIS ST - 1 M S OF SR26 | Concrete Culvert (3 spans) | -- | 1980 | -- | 9.8 | 33.1 | Good | 97.0 | 210A4240001 |
NBI report | FAS 96 | BRANCH | NEAR LIBERTY- TN. | Concrete Culvert (2 spans) | -- | 1982 | -- | 9.8 | 23.0 | Good | 90.4 | 21SR0960001 |
NBI report | FAS 96 | BRANCH | NEAR LIBERTY- TN. | Concrete Culvert (2 spans) | -- | 1982 | -- | 11.2 | 26.9 | Fair | 91.4 | 21SR0960007 |
NBI report | FAS 96 | JORDAN BRANCH | .5 MILE SOUTH OF SR 26 | Concrete Culvert (4 spans) | -- | 1982 | -- | 12.1 | 54.1 | Good | 91.4 | 21SR0960003 |
NBI report | FAS 96 | JORDAN BRANCH | NEAR LIBERTY- TN- | Concrete Culvert (2 spans) | NR possible | 1982 | -- | 9.8 | 26.9 | Fair | 91.4 | 21SR0960005 |
NBI report | NFA 2025 (SA 2116) | GOOSE CREEK | 1MI SOUTHWEST OF US70 | Concrete Culvert (3 spans) | -- | 1984 | -- | 12.1 | 40.0 | Good | 84.4 | 21020250003 |
NBI report | NFA 2191 (SA 2102) | PINE CREEK | 1MI EAST OF SR146 | Concrete Culvert (3 spans) | -- | 1984 | -- | 15.1 | 47.9 | Good | 83.9 | 21021910001 |
NBI report | NFA A016 | DISMAL BRANCH | 3MI EAST OF SR53 | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 26.9 | Good | 97.0 | 210A0580001 |
NBI report | NFA A227 | PINE CREEK | 3 MI EAST OF SR56 | Concrete Culvert (5 spans) | -- | 1984 | -- | 15.1 | 92.9 | Good | 96.0 | 210A1710001 |
NBI report | NFA A277 | CANEY BRANCH | 3MI NORTH OF WARREN CO. | Concrete Culvert (3 spans) | -- | 1984 | -- | 15.1 | 47.9 | Good | 93.0 | 210A2770001 |
NBI report | NFA A288 | SINK CREEK | 1.5 MI WEST OF SR56 | Concrete Culvert (3 spans) | -- | 1984 | -- | 12.1 | 40.0 | Fair | 85.0 | 210A2290001 |
NBI report | NFA A301 | SINK CREEK | .25 MI BLUE SPGS RD. | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 25.9 | Good | 92.0 | 210A3010001 |
NBI report | NFA 1116 (SA 2101) | SINK CREEK | 6 MI FROM SR56 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 38.1 | 119.1 | Good | 80.9 | 21011160001 |
NBI report | NFA 1118 (SA 2118) | OAKLEY CREEK | 2MI SOUTH OF SMITH CO. | Concrete Culvert (3 spans) | -- | 1985 | -- | 12.1 | 44.9 | Fair | 81.7 | 21S44280001 |
NBI report | NFA A054 | CLEAR FORK CREEK | .2MI EAST OF SR53 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1985 | -- | 49.9 | 149.0 | Good | 87.4 | 210A3200001 |
NBI report | NFA A323 | SMITH FORK CREEK | 01 MI FROM WILSON CO LI | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1985 | -- | 66.9 | 299.9 | Good | 90.8 | 210A3230001 |
NBI report | NFA A327 | DRY CREEK | 01 MI FROM DRY CREEK RD | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1985 | -- | 40.0 | 120.1 | Good | 87.6 | 210A2990001 |
NBI report | NFA A340 | DRY CREEK | .0 MI FROM DRY CREEK RD | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 40.0 | 118.1 | Good | 87.5 | 210A2940001 |
NBI report | NFA A347 | CLEAR FORK CREEK | .98 MI FROM SR53 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1985 | -- | 47.9 | 143.1 | Good | 92.0 | 210A3120001 |
NBI report | NFA A028 | BARGER HOLLOW BRANCH | MAIN ST-3.5 MI E OF SR96 | Concrete Culvert (2 spans) | -- | 1986 | -- | 9.8 | 24.9 | Good | 78.0 | 210A0280003 |
NBI report | NFA A254 | SINK CREEK | 4.1 MI FROM SR56 | Concrete Culvert (4 spans) | -- | 1986 | -- | 12.1 | 74.2 | Good | 92.0 | 210A2030001 |
NBI report | NFA A333 | BRANCH | .5MI WEST OF SR26 | Concrete Culvert | -- | 1986 | -- | 18.0 | 23.0 | Good | 78.3 | 210A3330001 |
NBI report | NFA A346 | CLEAR FORK CREEK | 0.24 MI FROM SR53 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1986 | -- | 29.9 | 90.9 | Good | 86.2 | 210A3130001 |
NBI report | FAS 264 | SMITH FORK CREEK | 2.2 MI.S.OF SMITH CO. | Prestressed Box Beam or girders - Single or Spread (5 spans) | -- | 1987 | -- | 69.9 | 348.1 | Fair | 82.6 | 21S44281003 |
NBI report | FAS 264 | WALKER CREEK | 4 MI.E.OF ALEXANDRIA | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 65.9 | 252.0 | Good | 93.8 | 21S44281001 |
NBI report | NFA A018 | DISMAL BRANCH | 3MI EAST OF SR53 | Concrete Culvert (2 spans) | -- | 1987 | -- | 12.1 | 25.9 | Good | 93.0 | 210A0180001 |
NBI report | NFA A266 | SINK CREEK | 7 MI S OF SMITHVILLE | Concrete Culvert (4 spans) | -- | 1987 | -- | 12.1 | 51.8 | Fair | 91.6 | 210A2660001 |
NBI report | NFA A285 | SINK CREEK | 1MI. WEST OF SR56 | Concrete Culvert (3 spans) | -- | 1987 | -- | 15.1 | 48.9 | Good | 97.0 | 210A2250001 |
NBI report | NFA A028 | SMITH FORK CREEK | IN LIBERTY | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1988 | -- | 60.0 | 240.2 | Fair | 97.7 | 210A0280001 |
NBI report | NFA A432 | FALL CREEK | IN CITY OF SMITHVILLE | Concrete Culvert (2 spans) | -- | 1989 | -- | 15.1 | 45.9 | Good | 90.5 | 210A2720001 |
NBI report | NFA A119 | SMALL BRANCH | 1.5 MI N OF SR 70 | Concrete Culvert (2 spans) | -- | 1990 | -- | 12.1 | 25.9 | Good | 96.0 | 210A1190001 |
NBI report | NFA A237 | SINK CREEK | 3MI NORTH OF WARREN CO. | Prestressed Box beam or girders - Multiple (4 spans) | -- | 1991 | -- | 46.9 | 184.1 | Good | 94.0 | 210A1900001 |
NBI report | NFA 2195 (SA 2112) | SMALL BRANCH | 6 MI WEST OF SMITHVILLE | Concrete Culvert (2 spans) | -- | 1992 | -- | 12.1 | 25.9 | Good | 81.9 | 21021950005 |
NBI report | NFA A052 | LONG BRANCH | .3MI SOUTH OF SR141 | Concrete Culvert (2 spans) | -- | 1993 | -- | 17.1 | 37.1 | Good | 97.0 | 210A3730001 |
NBI report | NFA A263 | SINK CREEK | .7 MI EAST OF SR56 | Prestressed Box Beam or girders - Single or Spread | -- | 1993 | -- | 75.1 | 75.1 | Good | 92.0 | 210A2180001 |
NBI report | NFA A417 | BARGER HOLLOW BRANCH | .1MI NORTH OF US70 | Concrete Culvert (2 spans) | -- | 1994 | -- | 12.1 | 29.9 | Good | 87.0 | 210A4090001 |
NBI report | NFA 2148 (SA 2119) | SMITH FORK CREEK | 1MI EAST OF HELTON TN. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1999 | -- | 91.2 | 272.3 | Good | 79.2 | 21021480001 |
NBI report | NFA A330 | BRANCH | 1 MI SOUTH OF US 70 | Concrete Culvert (2 spans) | -- | 1999 | -- | 9.8 | 22.0 | Good | 96.0 | 210A3300003 |
NBI report | FAP 26 | DRY CREEK | IN DOWELLTOWN CITY LIMITS | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2004 | -- | 76.1 | 301.9 | Good | 84.4 | 21SR0260013 |
NBI report | FAP 26 | OVERFLOW OF DRY CREEK | IN DOWELLTOWN CITY LIMITS | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 77.4 | 229.7 | Good | 84.8 | 21SR0260011 |
NBI report | FAP 26 | SMITH FORK CREEK | 7 MI.W.OF LIBERTY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2004 | -- | 98.8 | 358.0 | Good | 84.4 | 21SR0260007 |
NBI report | FAS 264 | REYNOLDS BRANCH | IN ALEXANDRIA | Concrete Culvert (2 spans) | -- | 2007 | -- | 22.3 | 80.4 | Good | 97.9 | 21F00100009 |
NBI report Bridgehunter | NFA A013 | SMITH FORK CREEK | 5MI EAST OF SR53 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2007 | -- | 105.0 | 292.0 | Poor | 72.8 | 210A0500001 |
NBI report | NFA A368 | HELTON CREEK | .5MI WEST OF US70 | Concrete Culvert (2 spans) | -- | 2007 | -- | 14.1 | 28.5 | Good | 87.4 | 210A3320001 |
NBI report | NFA 2149 (SA 2111) | DRY CREEK | 5MI SOUTHWEST OF US70 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2011 | -- | 57.1 | 113.9 | Good | 87.8 | 21021490001 |
NBI report | NFA A012 | HELTON CREEK | 5MI EAST OF SR53 | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2011 | -- | 33.1 | 98.1 | Good | 84.4 | 210A0610001 |
NBI report Bridgehunter | FAP 26 | CANEY FORK RV&NFA A199 | IN SMITHVILLE CITY LIMITS | Steel Stringer/Multi-beam or girder (5 spans) | -- | 2015 | -- | 335.0 | 1545.0 | Good | 83.9 | 21SR0260021 |
NBI report | NFA A095 | FALL CREEK | .1 MI WEST OF SR56 | Prestressed Stringer/Multi-beam or girder | -- | 2017 | -- | 91.5 | 91.5 | Good | 90.8 | 210A0810001 |
NBI report | NFA A299 (SA 2102) | SINK CREEK | 1 MI NORTH OF WARREN CO. | Concrete Culvert (2 spans) | -- | 2017 | -- | 16.1 | 32.8 | Good | 99.0 | 210A2380001 |
NBI report | NFA A329 | EGYPT HOLLOW BRANCH | 3MI SOUTHWEST OF US70 | Concrete Culvert (2 spans) | -- | 2017 | -- | 16.1 | 33.5 | Good | 80.0 | 210A2840001 |