Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | FAP 13 | BRANCH | 3 MI.N.OF HUMPHREYS CO. | Concrete Culvert (2 spans) | -- | 1928 | -- | 9.8 | 23.0 | Fair | 82.1 | 42SR0130001 |
NBI report Bridgehunter | FAS 13 | MUSTER GROUND CREEK | IN ERIN CITY LIMITS | Concrete Tee beam (3 spans) | -- | 1928 | 1973 | 26.9 | 80.1 | Poor | 55.4 | 42SR0130007 |
NBI report | FAS 13 | BRANCH | 4.7 MI.NORTHEAST OF ERIN | Concrete Culvert (3 spans) | -- | 1928 | 1978 | 7.9 | 46.9 | Fair | 81.0 | 42SR0130009 |
NBI report Bridgehunter | FAP 49 | MUSTER GROUND CREEK | IN ERIN CITY LIMITS | Concrete Tee beam (3 spans) | -- | 1932 | -- | 28.9 | 86.0 | Fair | 61.7 | 42SR0490005 |
NBI report Bridgehunter | FAP 49 | TOWN CREEK | 6.1 MI.SOUTHEAST OF ERIN | Concrete Tee beam (3 spans) | -- | 1932 | -- | 23.0 | 67.9 | Fair | 70.7 | 42SR0490007 |
NBI report | FAP 49 | WELLS CREEK | IN ERIN CITY LIMITS | Concrete Tee beam (5 spans) | -- | 1932 | 1965 | 35.1 | 174.9 | Poor | 15.9 | 42SR0490003 |
NBI report | FAP 49 | SALMON CREEK | 7.1 MI.SOUTHEAST OF ERIN | Concrete Tee beam (2 spans) | -- | 1932 | 2000 | 39.0 | 78.1 | Fair | 72.7 | 42SR0490009 |
NBI report | FAP 49 | ERIN BRANCH | IN ERIN CITY LIMITS | Prestressed Box Beam or girders - Single or Spread (5 spans) | -- | 1941 | 2009 | 43.0 | 209.0 | Fair | 67.8 | 42SR0490001 |
NBI report | NFA 910 (SA 4201) | WHITEOAK CREEK | 4 M S OF STEWART | Prestressed Box beam or girders - Multiple | -- | 1945 | 1968 | 60.0 | 210.0 | Poor | 63.4 | 42S62610007 |
NBI report | NFA 910 (SA 4201) | DRY HOLLOW BRANCH | 1 M SW OF MCKINNON | Concrete Culvert (3 spans) | -- | 1947 | -- | 12.1 | 39.0 | Fair | 74.7 | 42S62610003 |
NBI report | NFA 910 (SA 4201) | CURT BRANCH | 4 M S OF STEWART | Concrete Culvert (3 spans) | -- | 1947 | -- | 12.1 | 44.9 | Good | 95.1 | 42S62610005 |
NBI report | NFA A024 | S. FORK HURRICANE CREEK | 1 M. N. TENN. RIDGE. | Concrete Culvert (2 spans) | -- | 1950 | -- | 9.8 | 22.0 | Fair | 62.3 | 420A0240001 |
NBI report | NFA A170 | AVERITT BRANCH | 2.8 M. S. ERIN. | Concrete Culvert (2 spans) | -- | 1954 | -- | 11.2 | 37.1 | Fair | 67.7 | 420A1700001 |
NBI report | NFA 1791 (SA 4204) | ROSS BRANCH | 2.5 M S OF ERIN | Concrete Culvert (2 spans) | -- | 1958 | -- | 9.8 | 22.0 | Fair | 91.8 | 42017830007 |
NBI report | NFA 937 (SA 4202) | WHITEOAK CREEK | 4 M S OF TENN RIDGE | Concrete Tee beam (9 spans) | -- | 1959 | -- | 43.0 | 271.0 | Fair | 69.7 | 42S62610009 |
NBI report | FAS 231 | HALF PONE HOLLOW BRANCH | 7.5 MI.SOUTHEAST OF ERIN | Concrete Culvert (3 spans) | -- | 1960 | -- | 12.1 | 55.1 | Fair | 85.5 | 42S62250001 |
NBI report | NFA 1783 (SA 4204) | NORTH FORK | 4 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 26.9 | Good | 75.9 | 42017830001 |
NBI report | NFA 1783 (SA 4204) | LONG BRANCH | 4 M S OF TENN RIDGE | Concrete Culvert (3 spans) | -- | 1960 | -- | 15.1 | 50.9 | Fair | 83.9 | 42017830003 |
NBI report | NFA A143 | ERIN BRANCH | BWT-MAIN&MAPLE ST.IN ERIN | Concrete Culvert (2 spans) | -- | 1960 | -- | 12.1 | 24.9 | Good | 81.3 | 420A1430001 |
NBI report | FAS 232 | HURRICANE CREEK | 1.8 MI.N.OF MCKINNON | Concrete Tee beam (4 spans) | -- | 1961 | -- | 28.9 | 113.9 | Poor | 60.8 | 42FA1230001 |
NBI report | NFA 910 (SA 4201) | BRANCH | 5 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1962 | -- | 9.8 | 23.0 | Good | 97.0 | 42F02200003 |
NBI report | NFA A014 | CANE CREEK | 0.5 M. E. STEWART. | Concrete Culvert (2 spans) | -- | 1962 | -- | 15.1 | 32.2 | Fair | 86.7 | 420A0140001 |
NBI report | FAS 46 | GUICES CREEK | .2 M S JCT SR13&SR46 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1964 | -- | 29.9 | 94.2 | Fair | 67.2 | 42S61440001 |
NBI report | NFA 1783 | ERIN BRANCH | TANK HILL RD. IN ERIN. | Concrete Culvert (2 spans) | -- | 1965 | -- | 12.1 | 25.9 | Poor | 48.4 | 420A1450001 |
NBI report | NFA 1791 (SA 4204) | WELLS CREEK | 1.4 M S OF ERIN | Concrete Culvert (3 spans) | -- | 1965 | -- | 15.1 | 48.9 | Fair | 64.6 | 42017830015 |
NBI report | NFA 1791 (SA 4204) | ROSS BRANCH | 1.5 M S OF ERIN | Concrete Culvert (2 spans) | -- | 1965 | -- | 14.1 | 28.9 | Fair | 81.7 | 42017910013 |
NBI report | NFA A029 (SA 4211) | BRIGHAM BRANCH | 2.2 M. NW. ERIN. | Concrete Culvert (2 spans) | -- | 1965 | -- | 12.1 | 25.9 | Good | 79.3 | 420A0290001 |
NBI report | NFA A150 | ERIN BRANCH | ROCKY HOLLOW RD. IN ERIN. | Concrete Culvert (2 spans) | -- | 1966 | -- | 12.1 | 26.9 | Fair | 85.8 | 420A1500001 |
NBI report | NFA A150 | BRANCH | ROCKY HOLLOW RD. IN ERIN. | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 24.9 | Good | 95.8 | 420A1500003 |
NBI report | NFA A152 | ERIN BRANCH | MCMILLAN ST. IN ERIN. | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 22.0 | Good | 98.0 | 420A1520003 |
NBI report | NFA 910 (SA 4201) | CANE CREEK | .5 M S OF MCKINNON | Concrete Tee beam (3 spans) | -- | 1967 | -- | 46.9 | 143.1 | Fair | 78.4 | 42S62610001 |
NBI report | NFA 1781 (SA 4203) | LEWIS CREEK | 2.1 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1968 | -- | 18.0 | 38.1 | Fair | 85.8 | 42S63650005 |
NBI report | NFA 1791 (SA 4204) | ROSS BRANCH | 2.3 M S OF ERIN | Concrete Culvert (2 spans) | -- | 1968 | -- | 9.8 | 32.2 | Fair | 86.8 | 42017830009 |
NBI report | NFA 1791 (SA 4204) | ROSS BRANCH | 2.5 M S OF ERIN | Concrete Culvert (2 spans) | -- | 1968 | -- | 12.1 | 29.9 | Fair | 87.8 | 42017830011 |
NBI report | NFA 1820 (SA 4206) | BATEMAN BRANCH | 3 M. SE. ERIN. | Concrete Culvert (3 spans) | -- | 1968 | -- | 15.1 | 56.1 | Fair | 62.0 | 42018200001 |
NBI report | FAP 49 | DRY CREEK | 8 MILES SOUTHEAST OF ERIN | Concrete Culvert (3 spans) | -- | 1970 | -- | 9.8 | 34.1 | Good | 89.7 | 42SR0490013 |
NBI report | NFA A158 (SA 4210) | AVERITT BRANCH | 3.5 M. S. ERIN. | Concrete Culvert (2 spans) | -- | 1971 | -- | 9.8 | 22.0 | Fair | 86.8 | 420A1580001 |
NBI report | FAP 13 | POLLARD BRANCH | 2.2 MILES SOUTH OF ERIN | Concrete Culvert (3 spans) | -- | 1972 | -- | 12.1 | 44.9 | Fair | 73.2 | 42SR0130003 |
NBI report | FAP 13 | BATEMAN BRANCH | .8 MILE SOUTH OF ERIN | Concrete Culvert (3 spans) | -- | 1972 | -- | 15.1 | 67.9 | Fair | 77.1 | 42SR0130005 |
NBI report | NFA 1789 (SA 4207) | YELLOW CREEK | 8 M E OF ERIN | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | -- | 69.9 | 278.9 | Good | 98.0 | 42S63780001 |
NBI report | NFA A031 | SPRING BRANCH | 1 M. N. ERIN. | Concrete Culvert (2 spans) | -- | 1972 | -- | 11.2 | 24.0 | Fair | 81.0 | 420A0310001 |
NBI report | NFA A031 | BRANCH | 2 M. N. ERIN. | Concrete Culvert (2 spans) | -- | 1972 | -- | 15.1 | 33.1 | Fair | 93.7 | 420A0310003 |
NBI report | NFA A031 | BRIGHAM BRANCH | 2 M. N. ERIN. | Concrete Culvert (4 spans) | -- | 1972 | -- | 17.1 | 73.2 | Fair | 95.0 | 420A0310005 |
NBI report | NFA A113 | PATTERSON BRANCH | 7 M. S. ERIN. | Concrete Culvert (2 spans) | -- | 1972 | -- | 15.1 | 30.8 | Good | 97.0 | 420A1130001 |
NBI report | FAS 46 | SHOULDER STRAP BRANCH | 1.4 MILE SOUTH OF SR049 | Concrete Culvert (3 spans) | -- | 1973 | -- | 9.8 | 34.1 | Fair | 85.1 | 42S61430001 |
NBI report | NFA 1781 (SA 4203) | BRANCH | 2.3 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1974 | -- | 15.1 | 33.1 | Fair | 90.4 | 42S63650003 |
NBI report | NFA 1781 (SA 4203) | LEWIS BRANCH | 1.5 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1974 | -- | 14.1 | 29.9 | Fair | 95.8 | 42S63650007 |
NBI report | NFA 910 (SA 4201) | BRANCH | 4.2 M S OF STEWART | Concrete Culvert (2 spans) | -- | 1974 | -- | 12.1 | 37.1 | Fair | 94.9 | 42F02190001 |
NBI report | NFA A009 | MUSTERGROUND CREEK | 3.5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 1974 | -- | 12.1 | 25.9 | Good | 96.0 | 420A1630001 |
NBI report | NFA A109 | HALF PONE BRANCH | 8 M. S. ERIN. | Concrete Culvert (3 spans) | -- | 1974 | -- | 12.1 | 39.0 | Fair | 96.0 | 420A1090001 |
NBI report | FAS 46 | GUICES CREEK | 1.5 M N JCT SR13&SR46 | Concrete Tee beam (3 spans) | -- | 1975 | -- | 27.9 | 83.0 | Fair | 78.1 | 42017870003 |
NBI report | NFA 1783 (SA 4204) | LONG BRANCH | 4.25 M SE OF TENN RIDGE | Concrete Culvert (3 spans) | -- | 1975 | -- | 15.1 | 56.1 | Fair | 95.9 | 42017830005 |
NBI report | NFA A048 | GUICES CREEK | 5 M. NE. ERIN. | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1975 | -- | 29.9 | 65.0 | Fair | 83.0 | 420A0480003 |
NBI report | NFA A018 | HURRICANE CREEK | 2.3 M. NW. MCKINNON. | Concrete Culvert (2 spans) | -- | 1976 | -- | 9.8 | 22.0 | Poor | 70.0 | 420A0180001 |
NBI report | NFA A211 | CANE CREEK | 1.5 M SW OF MCKINNON | Concrete Culvert (2 spans) | -- | 1976 | -- | 9.8 | 22.0 | Fair | 97.0 | 420A2110001 |
NBI report | FAS 13 | GRICES CREEK | 4.85 MI.NORTHEAST OF ERIN | Concrete Culvert (3 spans) | -- | 1978 | -- | 15.1 | 47.9 | Fair | 87.8 | 42SR0130011 |
NBI report | NFA 1781 (SA 4203) | LONG BRANCH | 5 M SW OF ERIN | Prestressed Stringer/Multi-beam or girder | -- | 1979 | -- | 82.0 | 85.0 | Good | 89.3 | 42S63650001 |
NBI report | FAP 149 | WELLS CREEK | 1.96 MILE NORTH OF ERIN | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1980 | -- | 36.1 | 144.0 | Good | 83.8 | 42SR1490001 |
NBI report | NFA 1785 (SA 4214) | BOAZ BRANCH | 8 M SE OF ERIN | Prestressed Box Beam or girders - Single or Spread | -- | 1982 | -- | 28.9 | 32.2 | Good | 92.4 | 42017850001 |
NBI report | NFA 1789 (SA 4207) | LEATHERWOOD CREEK | 8 M E OF ERIN | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1982 | -- | 24.9 | 51.8 | Good | 87.4 | 42S63780003 |
NBI report | NFA A076 | DRY BRANCH | 5.5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 1982 | -- | 10.2 | 22.6 | Good | 96.9 | 420A0760003 |
NBI report | NFA 1783 (SA 4205) | BRIGHAM BRANCH | 2 M. N. ERIN. | Concrete Culvert (3 spans) | -- | 1983 | -- | 15.1 | 47.9 | Good | 97.0 | 420A0400001 |
NBI report | NFA A056 | MOORE BRANCH | 6 M. NE. ERIN. | Concrete Culvert (2 spans) | -- | 1983 | -- | 15.1 | 38.1 | Good | 97.0 | 420A0560001 |
NBI report | NFA A076 | BRANCH | 5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 1983 | -- | 15.1 | 33.1 | Good | 96.9 | 420A0760001 |
NBI report | NFA A101 | SALMON BRANCH | 7.5 M. SE. ERIN. | Concrete Culvert (2 spans) | -- | 1983 | -- | 15.1 | 33.1 | Good | 97.0 | 420A1010001 |
NBI report | NFA A134 | BATEMAN BRANCH | 2 M. SE. ERIN. | Concrete Culvert (3 spans) | -- | 1983 | -- | 15.1 | 47.9 | Fair | 97.0 | 420A1340003 |
NBI report | NFA A455 | BOOSTER BRANCH | 3.5 M. NE. ERIN. | Concrete Culvert (3 spans) | -- | 1983 | -- | 15.1 | 68.9 | Fair | 83.2 | 420A0340001 |
NBI report | FAS 147 | BRANCH | 2.7 MI.E.OF TENN.RIDGE | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 30.8 | Fair | 94.8 | 42SR1470001 |
NBI report | FAS 147 | NORTH FORK CANE CREEK | 6.2 MI.E.OF TENN.RIVER | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1984 | -- | 30.8 | 74.2 | Fair | 77.5 | 42SR1470003 |
NBI report | NFA A038 | BRANCH | 1 M. N. TENN. RIDGE. | Concrete Culvert (2 spans) | -- | 1984 | -- | 15.1 | 44.0 | Fair | 74.9 | 420A0380001 |
NBI report | NFA A065 | MOORE BRANCH | 6 M. NE. ERIN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 15.1 | 46.9 | Fair | 94.8 | 420A0650001 |
NBI report | NFA A074 | LEATHERWOOD CREEK | 9 M. E. ERIN. | Concrete Culvert (4 spans) | -- | 1984 | -- | 12.1 | 51.8 | Fair | 92.8 | 420A0740001 |
NBI report | NFA A110 | DRY CREEK | 5.5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 15.1 | 33.1 | Good | 91.2 | 420A1100001 |
NBI report | NFA A119 | PATTERSON BRANCH | 6.5 M. S. ERIN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 37.1 | Good | 91.6 | 420A1190001 |
NBI report | NFA A123 | BATEMAN BRANCH | 4.5 M. SE. ERIN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 12.1 | 37.1 | Fair | 88.4 | 420A1230001 |
NBI report | NFA A123 | BATEMAN BRANCH | 5 M. SE. ERIN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 9.8 | 22.0 | Good | 86.9 | 420A1230003 |
NBI report | NFA A164 | FRANKS BRANCH | 4.5 M. S. STEWART. | Concrete Culvert (2 spans) | -- | 1984 | -- | 15.1 | 34.1 | Good | 96.0 | 420A1640001 |
NBI report | NFA A206 | CURT BRANCH | 3.5 M S OF MCKINNON | Concrete Culvert (3 spans) | -- | 1984 | -- | 12.1 | 55.1 | Good | 97.0 | 420A1800003 |
NBI report | NFA 1785 (SA 4214) | YELLOW CREEK | 8 M SE OF ERIN | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1985 | -- | 84.0 | 337.0 | Good | 86.9 | 42G02120003 |
NBI report | NFA A097 | SALMON BRANCH | 8 M. SE. ERIN. | Concrete Culvert (3 spans) | -- | 1986 | -- | 12.1 | 55.1 | Good | 86.9 | 420A0970001 |
NBI report | NFA A149 | BRANCH | 2 M.SE. TENN. RIDGE | Concrete Culvert (2 spans) | -- | 1986 | -- | 15.1 | 34.1 | Fair | 82.1 | 420A1490001 |
NBI report | NFA A161 | LEWIS BRANCH | 3.5 M. S. TENN. RIDGE. | Concrete Culvert (3 spans) | -- | 1986 | -- | 15.1 | 56.1 | Good | 97.0 | 420A1610001 |
NBI report | NFA A253 | BOOSTER BRANCH | 3.3 M N OF ERIN | Concrete Culvert (2 spans) | -- | 1987 | -- | 12.1 | 37.1 | Fair | 86.9 | 420A2530001 |
NBI report | NFA A455 | WELLS CREEK | 3 M. NE. ERIN. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 56.1 | 170.0 | Good | 81.6 | 420A0340003 |
NBI report | FAP 49 | JORDAN BRANCH | .5 M. E. OF DICKSON CO LN | Concrete Culvert (2 spans) | -- | 1989 | -- | 9.8 | 22.0 | Fair | 95.1 | 42SR0490015 |
NBI report | NFA A164 | LEWIS BRANCH | 3 M. S. TENNESSEE RIDGE. | Concrete Culvert (3 spans) | -- | 1991 | -- | 12.1 | 54.1 | Fair | 97.0 | 420A1640003 |
NBI report | NFA A262 | POLLARD BRANCH | 4 M S OF ERIN- TN | Concrete Culvert (3 spans) | -- | 1991 | -- | 12.1 | 55.1 | Fair | 95.0 | 420A2620001 |
NBI report | FAP 149 | MUSTERGOUND CREEK | IN CITY OF ERIN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 62.0 | 191.0 | Fair | 84.8 | 42SR1490003 |
NBI report | FAP 149 | WELL'S CREEK | 4 M S STEWART CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 64.0 | 192.9 | Good | 84.8 | 42SR1490005 |
NBI report | FAP 149 | WELL'S CREEK | 3.8 M S STEWART CO LINE | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 64.0 | 192.9 | Fair | 83.3 | 42SR1490007 |
NBI report | FAP 149 | SPRING BRANCH | 3 M S STEWART CO LINE | Concrete Culvert (3 spans) | -- | 1992 | -- | 12.1 | 43.0 | Good | 84.5 | 42SR1490009 |
NBI report | FAP 149 | CAVE BRANCH | 2 M S STEWART CO LINE | Concrete Culvert (3 spans) | -- | 1992 | -- | 9.8 | 33.1 | Fair | 69.8 | 42SR1490011 |
NBI report | FAP 149 | LICKSKILLET BRANCH | .5 M S STEWART CO LINE | Concrete Culvert (3 spans) | -- | 1992 | -- | 12.1 | 39.0 | Good | 84.8 | 42SR1490013 |
NBI report | NFA A022 | S FORK HURRICANE CREEK | 1.5 M. N. TENN. RIDGE. | Concrete Culvert (3 spans) | -- | 1993 | -- | 12.1 | 55.1 | Good | 90.8 | 420A0220001 |
NBI report | NFA A145 | BRANCH | BAILEY HOLLOW RD | Concrete Culvert (2 spans) | -- | 1993 | -- | 9.8 | 23.0 | Fair | 84.0 | 420A1450003 |
NBI report | NFA A151 | ERIN BRANCH | ARLINGTON ST. IN ERIN. | Concrete Culvert (2 spans) | -- | 1993 | -- | 12.1 | 25.9 | Good | 84.7 | 420A1510001 |
NBI report | NFA A123 | BRANCH | .43 M S BATEMAN BR RD | Concrete Culvert (2 spans) | -- | 1994 | -- | 12.1 | 29.9 | Good | 80.3 | 420A1230005 |
NBI report | NFA A171 | SALMON BRANCH | SALMON BRANCH RD | Concrete Culvert (2 spans) | -- | 1994 | -- | 9.8 | 22.0 | Good | 97.0 | 420A1710001 |
NBI report | NFA 910 (SA 4201) | BRANCH | 4 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 1995 | -- | 9.8 | 30.8 | Good | 97.0 | 42F02200001 |
NBI report | NFA A110 | GUICES CREEK | 5.5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 1995 | -- | 12.1 | 29.9 | Fair | 91.2 | 420A1100003 |
NBI report | NFA A476 | BEAN CREEK | 10.5 M. SE. ERIN. | Concrete Culvert (3 spans) | -- | 1996 | -- | 18.0 | 58.1 | Fair | 86.0 | 420A0930001 |
NBI report | NFA A476 | CHILDERS BRANCH | BEAR CR. RD. -HOUSTON CO. | Concrete Culvert (2 spans) | -- | 1997 | -- | 11.8 | 25.6 | Fair | 95.0 | 420A0930003 |
NBI report | FAP 49 | YELLOW CREEK | .75 MILE W.OF DICKSON CO. | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1998 | -- | 80.7 | 244.1 | Good | 93.7 | 42SR0490011 |
NBI report | NFA A207 | WELLS CREEK | BOONE HOLLOW RD | Prestressed Box beam or girders - Multiple | -- | 1998 | -- | 70.2 | 72.2 | Good | 91.8 | 420A2070001 |
NBI report | NFA A139 | MUSTERGROUND CREEK | 6.5 M. E. ERIN. | Concrete Culvert (3 spans) | -- | 2000 | -- | 15.1 | 50.2 | Good | 93.9 | 420A1390001 |
NBI report | NFA A337 | WELLS CREEK | 1 M N LONG BRANCH RD | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2000 | -- | 58.1 | 117.1 | Good | 93.9 | 420A3370001 |
NBI report | NFA A479 | LEWIS CREEK | 2 M S OF TENN RIDGE | Concrete Culvert (2 spans) | -- | 2001 | -- | 15.1 | 34.1 | Good | 99.0 | 420A4790001 |
NBI report | NFA A086 | BRIGHAM BRANCH | BRIGHAM BRIDGE RD | Prestressed Box Beam or girders - Single or Spread | -- | 2002 | -- | 57.1 | 58.1 | Good | 98.7 | 420A0860001 |
NBI report | NFA A186 | LEWIS BRANCH | LEWIS BRANCH RD | Concrete Culvert (2 spans) | -- | 2002 | -- | 12.1 | 26.6 | Good | 93.5 | 420A1860001 |
NBI report | NFA A192 | S FORK HURRICANE CREEK | MAPLE RD. - HOUSTON CO. | Concrete Culvert (2 spans) | -- | 2003 | -- | 12.1 | 32.2 | Good | 99.0 | 420A1920001 |
NBI report | NFA A198 | CANE CREEK | 2 M W OF STEWART | Prestressed Box Beam or girders - Single or Spread | -- | 2003 | -- | 65.9 | 70.9 | Good | 98.7 | 420A1980001 |
NBI report | NFA A224 | ERIN BRANCH | E MAPLE ST IN ERIN | Concrete Culvert (3 spans) | -- | 2005 | -- | 12.1 | 44.6 | Good | 79.5 | 420A2240001 |
NBI report | NFA A398 | BATEMAN BRANCH | JOHN BROOKS LANE | Concrete Culvert (2 spans) | -- | 2005 | -- | 16.1 | 35.4 | Good | 93.8 | 420A3980001 |
NBI report | NFA A048 | WELLS CREEK | MARABLE HOLLOW RD | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2006 | -- | 60.0 | 160.1 | Good | 98.0 | 420A0480001 |
NBI report | NFA A169 | HALF PONE BRANCH | JUDY BRANCH ROAD | Concrete Culvert (2 spans) | -- | 2007 | -- | 12.1 | 26.2 | Good | 93.9 | 420A1690001 |
NBI report | NFA A138 | DRY BRANCH | TOM STANFILL LOOP | Concrete Culvert (2 spans) | -- | 2011 | -- | 18.4 | 38.1 | Good | 92.9 | 420A1380001 |
NBI report | NFA A410 | POLLARD BRANCH | 2 M S OF TENN RIDGE | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2016 | -- | 18.7 | 36.7 | Good | 78.0 | 420A4100001 |
NBI report | NFA A128 | GUICES CREEK | 5.5 M. E. ERIN. | Concrete Culvert (2 spans) | -- | 2017 | -- | 12.1 | 28.2 | Good | 94.9 | 420A1280001 |