Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report Bridgehunter | FAS 1 | TOWN CREEK | IN SPARTA CITY LIMITS | Concrete Tee beam (2 spans) | -- | 1923 | 1962 | 33.1 | 65.9 | Fair | 44.9 | 93SR0010003 |
NBI report Bridgehunter | NFA A966 | FALLING WATER RIVER | AT PUTNAM COUNTY LINE | Concrete Tee beam (5 spans) | -- | 1935 | -- | 43.0 | 214.9 | Poor | 36.9 | 93SR0420003 |
NBI report Bridgehunter | NFA A966 | POST OAK CREEK | 1 FM PUTNAM WHITE CO LI | Concrete Tee beam (4 spans) | -- | 1942 | -- | 43.0 | 171.9 | Poor | 48.7 | 93SR0420001 |
NBI report | FAP 1 | CALFKILLER RIVER | IN SPARTA CITY LIMITS | Concrete Tee beam (6 spans) | -- | 1949 | 1996 | 43.0 | 229.0 | Fair | 81.7 | 93SR0010007 |
NBI report | FAP 26 | TOWN CREEK | 0.7 MI. W. OF SR-111 JCT. | Concrete Culvert (3 spans) | -- | 1951 | -- | 12.1 | 42.0 | Fair | 75.4 | 93SR0260003 |
NBI report | FAP 26 | BRANCH | 0.2 MI. W. OF SR-136 JCT. | Concrete Culvert (3 spans) | -- | 1951 | -- | 9.8 | 39.0 | Good | 60.7 | 93SR0260001 |
NBI report | NFA 1159 (SA 9318) | HICKORY VALLEY BRANCH | 5MI NORTH OF VAN BUREN CO | Concrete Culvert (3 spans) | -- | 1952 | -- | 15.1 | 50.9 | Poor | 48.2 | 93S42510007 |
NBI report | NFA 1159 (SA 9318) | HICKORY VALLEY BRANCH | 5MI NORTH OF VAN BUREN CO | Concrete Culvert (4 spans) | -- | 1952 | -- | 15.1 | 90.9 | Fair | 69.4 | 93S42510005 |
NBI report | NFA 1159 (SA 9318) | HICKORY VALLEY BRANCH | 5MI EAST OF SR111 | Concrete Culvert (3 spans) | -- | 1952 | -- | 15.1 | 70.9 | Good | 75.0 | 93S42510003 |
NBI report | NFA 1163 (SA 9316) | BRANCH | .5MI FROM PUTNAM CO LINE | Concrete Culvert (2 spans) | -- | 1952 | -- | 15.1 | 33.1 | Good | 82.7 | 93S42450007 |
NBI report | NFA 1163 (SA 9316) | POST OAK CREEK | 1MI FROM PUTNAM CO LINE | Concrete Culvert (3 spans) | -- | 1956 | -- | 9.8 | 32.2 | Good | 97.8 | 93S42450005 |
NBI report | NFA 2202 (SA 9322) | CLIFTY CREEK | 2MI SOUTH OF CUMBERLANDCO | Concrete Culvert (3 spans) | -- | 1960 | -- | 12.1 | 38.1 | Fair | 85.1 | 930A2380001 |
NBI report Bridgehunter | NFA A082 | TAYLOR CREEK | 3MI NORTH OF US 70 | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1960 | 1989 | 37.1 | 60.0 | Good | 80.9 | 930A0820001 |
NBI report | NFA A179 | SIMMS BRANCH | 5MI WORTH OF US 70 | Prestressed Box Beam or girders - Single or Spread | -- | 1960 | 2002 | 28.9 | 28.9 | Good | 88.8 | 930A1790001 |
NBI report | FAS 1 349561G | CANEY FORK & WESTERN RR | 2 MI FROM SR111 | Steel Stringer/Multi-beam or girder | -- | 1962 | -- | 73.2 | -- | -- | -- | 93SR0010005 |
NBI report | FAS 84 | CHERRY CREEK | 6 MI.EAST OF SR001 | Concrete Culvert (3 spans) | -- | 1963 | -- | 15.1 | 47.9 | Good | 95.9 | 93SR0840003 |
NBI report | NFA 2216 (SA 9312) | FALLING WATER RIVER | 5MI SOUTH OF PUTNAM CO | Concrete Tee beam (7 spans) | -- | 1963 | -- | 51.8 | 219.2 | Fair | 74.5 | 93022160001 |
NBI report | NFA 2190 | LOST CREEK | 7MI NORTH OF VAN BUREN CO | Concrete Tee beam (3 spans) | -- | 1965 | -- | 41.0 | 100.1 | Good | 90.4 | 93021900003 |
NBI report | FAS 84 | FLATT BRANCH | 3 MI.S.OF PUTNAM CO. | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 23.0 | Good | 99.1 | 93SR0840007 |
NBI report | FAS 84 | PLUM CREEK | 7 MI.S.OF PUTNAM CO. | Concrete Culvert (2 spans) | -- | 1966 | -- | 9.8 | 22.0 | Good | 94.0 | 93SR0840005 |
NBI report | NFA 1159 (SA 9318) | CANEY FORK RIVER | 1 MI N OF VAN BUREN CO LI | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 159.1 | 426.9 | Good | 91.8 | 93S42510001 |
NBI report | FAS 285 | CALFKILLER RIVER | 2 MI E OF US RT 70S | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 106.0 | 323.2 | Fair | 74.2 | 93E00090001 |
NBI report | FAP 111 | CALFKILLER RIVER | 6 MI.N.OF VAN BUREN CO. | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1995 | 134.8 | 490.2 | Good | 89.2 | 93SR1110001 |
NBI report | FAP 111 | SR 1 (US 70S) & NFA 2727 | IN SPARTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1971 | 1995 | 94.2 | 188.0 | Fair | 88.0 | 93SR0010001 |
NBI report | NFA 1140 (SA 9302) | CALFKILLER RIVER | 8MI EAST OF SR1 | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1973 | -- | 65.0 | 319.9 | Good | 91.9 | 93S43660001 |
NBI report | NFA A043 | TOWN CREEK | .23 MILES FROM PUTNAM CO | Concrete Slab | -- | 1973 | 1983 | 25.9 | 30.8 | Good | 97.0 | 930A0430001 |
NBI report | NFA A311 | CANEY FORK RIVER | 6MI WEST OF SR111 | Steel Girder and floorbeam system (2 spans) | -- | 1974 | -- | 266.1 | 538.1 | Fair | 96.9 | 930A3110001 |
NBI report | FAP 111 | TOWN CREEK | 0.1 MI. S. OF SR-26 JCT. | Concrete Culvert | -- | 1975 | -- | 22.0 | 22.0 | Good | 81.2 | 93SR1110019 |
NBI report | FAP 26 | SR 111 | IN SPARTA | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1975 | -- | 128.9 | 257.9 | Fair | 98.4 | 93SR0260005 |
NBI report | FAS 136 | RUM CREEK | 2 MI N OF SR 26 | Concrete Culvert (2 spans) | -- | 1975 | -- | 7.9 | 20.3 | Good | 93.7 | 93SR1360003 |
NBI report | FAS 84 | CALFKILLER RIVER | 2 MI.N.OF SR001 | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1976 | -- | 111.9 | 224.1 | Good | 93.1 | 93SR0840001 |
NBI report | NFA 2186 (SA 9303) | CANEY FORK RIVER | 1MI FROM US70S | Steel Girder and floorbeam system (2 spans) | -- | 1976 | -- | 232.0 | 471.2 | Fair | 87.7 | 93021860001 |
NBI report | NFA 2206 (SA 9320) | BLUE SPRING CREEK | 5MI NORTH OF US 70 | Concrete Culvert (2 spans) | -- | 1981 | -- | 15.1 | 32.2 | Fair | 97.8 | 93022060003 |
NBI report | NFA A136 | POST OAK CREEK | .67MI SOUTH OF PUTNAM CO | Concrete Culvert (3 spans) | -- | 1984 | -- | 15.1 | 49.9 | Good | 97.0 | 930A1360001 |
NBI report | NFA A279 | FOX HOLLOW CREEK | 4MI EAST OF SR111 | Concrete Culvert (3 spans) | -- | 1984 | -- | 12.1 | 40.0 | Good | 90.8 | 930A2790001 |
NBI report | NFA A710 | CLIFF CREEK | 1MI FROM CENTER POINT TN. | Concrete Culvert (2 spans) | -- | 1984 | -- | 15.1 | 33.1 | Good | 94.7 | 930A7100001 |
NBI report | NFA A178 | CALFKILLER RIVER | .1MI SOUTH OF SR84 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 46.9 | 143.1 | Good | 86.9 | 930A1780001 |
NBI report | NFA 1163 (SA 9316) | CHERRY CREEK | 5MI SOUTH OF PUTNAM CO | Concrete Culvert (3 spans) | -- | 1986 | -- | 15.1 | 49.9 | Good | 92.3 | 93S42450003 |
NBI report | NFA 2218 (SA 9314) | SR 111 | 6 MI. NORTH OF SPARTA | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1986 | -- | 125.0 | 241.2 | Good | 96.5 | 93SR1110007 |
NBI report | NFA A017 | SR 111 | 0.5 MI. FROM PUTMAN CO LN | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1986 | -- | 122.1 | 244.1 | Good | 98.0 | 93SR1110015 |
NBI report | NFA 2206 (SA 9320) | WILDCAT CREEK | 1.5 MI EAST OF SR 84 | Concrete Culvert (2 spans) | -- | 1987 | -- | 15.1 | 45.9 | Fair | 78.8 | 93022060005 |
NBI report | NFA 2214 (SA 9310) | ZION BRANCH | 1MI NORTH OF US 70 | Concrete Culvert (2 spans) | -- | 1987 | -- | 15.1 | 46.9 | Good | 79.8 | 93022140001 |
NBI report | NFA A164 | CHERRY CREEK | 5MI SOUTH OF PUTNAM CO IN | Concrete Culvert (3 spans) | -- | 1987 | -- | 12.1 | 39.0 | Good | 86.1 | 930A1640001 |
NBI report | NFA A415 349520C | CANEY FORK & WESTERN RR | .3 MI FROM VAN BUREN CO | Steel Stringer/Multi-beam or girder | -- | 1987 | 1998 | 41.0 | 43.0 | Good | 88.0 | 930A4150001 |
NBI report | FAP 111 | FALLING WATER RIVER | AT PUTNAM CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 76.1 | 225.1 | Good | 99.3 | 93SR1110017 |
NBI report | FAP 111 | POST OAK CREEK | 1 MI S OF PUTNAM CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 62.0 | 183.1 | Good | 98.3 | 93SR1110014 |
NBI report | FAP 111 | POST OAK CREEK | 1 MI S OF PUTNAM CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 62.0 | 183.1 | Good | 98.3 | 93SR1110013 |
NBI report | FAP 111 | FALLING WATER RIVER | AT PUTNAM CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 76.1 | 225.1 | Good | 99.3 | 93SR1110018 |
NBI report | FAP 111 | SR 111 / NFA A119 | 3.5 MI S OF PUTMAN CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 74.2 | 191.9 | Fair | 76.9 | 93SR1110010 |
NBI report | FAP 111 | SR 111 / NFA A119 | 3.5 MI S OF PUTMAN CO LN | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1988 | -- | 74.2 | 191.9 | Fair | 87.2 | 93SR1110009 |
NBI report | FAS 135 | SR 135 / SR 111 | NORTH OF SPARTA | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1988 | -- | 118.1 | 232.0 | Good | 97.8 | 93SR1110005 |
NBI report | FAS 136 | SR 136 / SR 111 | 2 MI S OF PUTNAM CO LN | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1988 | -- | 136.2 | 255.9 | Good | 98.1 | 93SR1110011 |
NBI report | FAS 289 | SR 289 / SR 111 | EAST OF SPARTA | Concrete Box Beam or girders - Single or Spread (2 spans) | -- | 1988 | -- | 126.0 | 244.1 | Good | 97.5 | 93SR1110003 |
NBI report | NFA 2208 | CALFKILLER RIVER | 5MI EAST OF SR 111 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 71.9 | 206.0 | Fair | 86.2 | 93022080001 |
NBI report | NFA A174 | CALFKILLER RIVER | .02 MI FROM PUTNAM CO IN | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 56.1 | 167.0 | Fair | 76.8 | 930A1740001 |
NBI report | NFA 2206 (SA 9320) | CALFKILLER RIVER | 2 MI SOUTH OF SR 84 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1989 | -- | 61.0 | 210.0 | Good | 94.9 | 93022060001 |
NBI report | NFA 1163 (SA 9316) | CHERRY CREEK | .68MI FROM SR84 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1991 | -- | 46.9 | 132.9 | Good | 91.6 | 93S42450001 |
NBI report | NFA A029 | FALLING WATER RIVER | 3.2 MI FROM SR111 | Prestressed Box Beam or girders - Single or Spread | -- | 1992 | -- | 71.9 | 75.1 | Fair | 93.9 | 930A0290001 |
NBI report | NFA A285 | LOST CREEK | 2 MI W OF BOTTOM RD | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 1994 | -- | 44.9 | 89.9 | Good | 83.7 | 930A2850001 |
NBI report | FAP 1 | CALFKILLER RV & DEMPS RD | 5 MI E. OF SR285 JCT. | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1996 | -- | 136.2 | 590.9 | Good | 98.7 | 93SR0010009 |
NBI report | FAP 1 | CALFKILLER RV & DEMPS RD | 5 MI E OF SR285 JCT | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1996 | -- | 136.2 | 592.9 | Good | 98.7 | 93SR0010010 |
NBI report | FAP 111 | SR 1 | 5 MI S OF SR 26 JCT | Steel Stringer/Multi-beam or girder (4 spans) | -- | 1996 | -- | 146.0 | 496.1 | Good | 80.5 | 93SR0010011 |
NBI report | NFA A007 | CHERRY CREEK | 5 M NORTH OF SR 1 | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 68.9 | 88.9 | Good | 80.6 | 930A0070001 |
NBI report | NFA 2214 (SA 9310) | TAYLOR CREEK | 2.5 MI NORTH OF US 70 | Concrete Culvert (3 spans) | -- | 1998 | -- | 15.1 | 49.2 | Good | 80.8 | 93022140003 |
NBI report | NFA 2214 | BRANCH | NW OF SR-1 & SR-136 JCT | Concrete Culvert (2 spans) | -- | 1999 | -- | 12.5 | 29.9 | Good | 86.4 | 93022140005 |
NBI report | NFA A473 | SMALL BRANCH | 2MI WEST OF US 70S | Concrete Culvert (2 spans) | -- | 2001 | -- | 12.1 | 24.9 | Good | 96.0 | 930A4730001 |
NBI report | NFA A238 | CLIFTY CREEK | 4 MI SE OF SR1 | Prestressed Box beam or girders - Multiple | -- | 2008 | -- | 92.9 | 92.9 | Good | 98.1 | 93022020001 |
NBI report | NFA A071 | TAYLOR CREEK | 3MI NORTH OF US70 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 80.1 | 200.1 | Good | 94.4 | 930A0710001 |
NBI report | FAS 135 | SR 135 / SR 111 | NORTH OF SPARTA | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2012 | -- | 118.1 | 232.0 | Fair | 99.2 | 93SR1110021 |
NBI report Bridgehunter | NFA 2190 | CANEY FORK RIVER | DODSON COMMUNITY | Steel Stringer/Multi-beam or girder | -- | 2012 | -- | 175.9 | 175.9 | Good | 90.8 | 93021900001 |