Carries | Crosses | Location | Design | Status | Year Built | Year Recon. | Span Len. | Total Len. | Condition | Suff. Rating | ID | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
NBI report | SR 161 | OHOP CREEK | 4.3 N JCT SR 7 | Concrete Tee beam | -- | -- | -- | 44.9 | 56.1 | Fair | 58.3 | 000000BG0000000 |
NBI report | SR 161 | TANWAX CR | 10.1 N JCT SR 7 | Concrete Culvert (2 spans) | -- | -- | -- | 9.8 | 21.0 | Good | 70.8 | 002000740000000 |
NBI report | PUYALLUP AVE | E 24TH&B ST& ABANDONED R | 0.5 N JCT I-5&SR7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1910 | 1980 | 22.0 | 136.2 | Fair | 98.8 | 085118000000000 |
NBI report Bridgehunter | NORTH 21ST STREET | BUCKLEY GULCH | N 21ST & FIFE | Concrete Girder and floorbeam system (4 spans) | NR listed | 1910 | 1997 | 60.0 | 180.1 | Good | 96.6 | 085541000000000 |
NBI report Bridgehunter | STATE ROUTE 509 | PUYALLUP WATERWAY RR | 2.5 N JCT I-5 | Steel Truss - Thru (3 spans) | -- | 1911 | -- | 161.1 | 571.9 | Poor | 9.8 | 0006069A0000000 |
NBI report Bridgehunter | E 11TH ST | CITY WATERWAY CS2749 | E 11TH ST JCT I-705 | Steel Movable - Lift | NR listed | 1911 | 2013 | 221.1 | 1748.1 | Fair | 84.7 | 0005452A0000000 |
NBI report | SR 165 | WILKESON CREEK | 16.8 N RAINIER PARK | Concrete Arch - Deck | -- | 1916 | 1941 | 49.9 | 77.1 | Fair | 51.8 | 0002687A0000000 |
NBI report Bridgehunter | SR 165 | WILKESON CREEK | 16.4 N RAINIER PARK | Concrete Arch - Deck | -- | 1918 | -- | 40.0 | 44.9 | Fair | 78.7 | 000000EI0000000 |
NBI report Bridgehunter | PETERSON RD E | OHOP CREEK OVERFLOW | .3 E JCT SR 7 | Concrete Culvert | -- | 1919 | -- | 29.9 | 54.1 | Fair | 94.3 | 082321000000000 |
NBI report Bridgehunter | PETERSON RD E | OHOP CREEK | .4 E JCT SR 7 | Concrete Culvert | -- | 1919 | -- | 29.9 | 29.9 | Fair | 95.0 | 082329000000000 |
NBI report | SR 507 | MUCK CREEK OVERFLOW | 7.4 N JCT SR 702 | Concrete Slab (2 spans) | -- | 1920 | 1950 | 9.8 | 32.2 | Fair | 63.2 | 0003884A0000000 |
NBI report | SR 507 | MUCK CREEK | 7.9 N JCT SR 702 | Concrete Slab (3 spans) | -- | 1920 | 1950 | 14.1 | 45.9 | Fair | 52.3 | 0003884B0000000 |
NBI report | ORVILLE RD E | KAPOWSIN CREEK | 10.7 NE JCT SR 161 | Concrete Tee beam | -- | 1920 | 1957 | 33.1 | 35.1 | Fair | 73.3 | 082587000000000 |
NBI report Bridgehunter | SR 165 | CARBON RIVER | 11.6 N RAINIER PARK | Steel Arch - Deck | NR listed | 1921 | 1945 | 240.2 | 494.1 | Fair | 50.6 | 0002950A0000000 |
NBI report | SR 7 | OHOP SLOUGH | 3.4 N JCT SR 161 | Concrete Tee beam (3 spans) | -- | 1922 | -- | 30.8 | 77.1 | Fair | 56.6 | 0000572A0000000 |
NBI report | SR 7 | OHOP SLOUGH | 3.5 N JCT SR 161 | Concrete Tee beam (3 spans) | -- | 1922 | -- | 30.8 | 77.1 | Fair | 58.2 | 0000572B0000000 |
NBI report | SR 706 | COPPER CR | 11.2 E JCT SR 7 | Concrete Tee beam | -- | 1922 | -- | 22.0 | 25.9 | Fair | 78.1 | 000000HA0000000 |
NBI report Bridgehunter | LONGMIRE SERVICE R | NISQUALLY RIVER | 0.25 MILES EAST OF LONGMI | Wood Suspension | -- | 1923 | 2005 | 180.1 | 180.1 | Fair | 20.8 | 9450002P0000000 |
NBI report Bridgehunter | Fish War Mem X-ing | PUYALLUP RIVER | 0.2 N JCT I-5 | Steel Truss - Thru (3 spans) | Closed | 1925 | -- | 252.0 | 764.1 | Poor | 6.0 | 085011000000000 |
NBI report Bridgehunter | Fish War Mem X-ing | RAILROAD | 0.2 N JCT I-5 | Steel Truss - Thru | Closed | 1925 | -- | 116.1 | 117.1 | Poor | 6.0 | 086562000000000 |
NBI report | Fish War Mem X-ing | TERRAIN | 0.2 N JCT I-5 | Concrete Stringer/Multi-beam or girder (3 spans) | Closed | 1925 | -- | 39.0 | 95.1 | Fair | 7.0 | 086565000000000 |
NBI report | Fish War Mem X-ing | RAMP | 0.2 N JCT I-5 | Concrete Stringer/Multi-beam or girder (8 spans) | Closed | 1925 | -- | 53.2 | 417.0 | Fair | 5.0 | 086566000000000 |
NBI report Bridgehunter | PARADISE CONNECTIO | EDITH CREEK | 18.0 miles northeast of N | Concrete Arch - Deck | -- | 1926 | -- | 32.2 | 32.2 | Fair | 78.0 | 9450017P0000000 |
NBI report Bridgehunter | PARADISE CONNECTIO | PARADISE RIVER | 18.2 miles northeast of N | Concrete Arch - Deck | -- | 1926 | -- | 32.2 | 32.2 | Good | 63.6 | 9450018P0000000 |
NBI report | 66 AV E | CLARKS CREEK | 0.8 S JCT SR 410 | Concrete Tee beam | -- | 1927 | -- | 29.9 | 36.1 | Good | 75.6 | 082438000000000 |
NBI report Bridgehunter | BRIDGE STREET | STUCK RIVER | 0.3 E JCT SR 167 | Steel Truss - Thru | -- | 1927 | -- | 220.2 | 359.9 | Poor | 84.0 | 085419000000000 |
NBI report | INTERLAAKEN DR SW | STEILACOOM LAKE | 1.0 E JCT GRVLY LK | Wood Stringer/Multi-beam or girder (43 spans) | -- | 1927 | 1951 | 28.9 | 682.1 | Fair | 29.4 | 079998000000000 |
NBI report | SR 99 | HYLEBOS CREEK | 1.1 N JCT I-5 | Concrete Tee beam | -- | 1927 | 1953 | 29.9 | 32.2 | Fair | 75.3 | 0001105A0000000 |
NBI report Bridgehunter | NORTH PROCTOR | PUGET GULCH N32 TO N 33S | 3.5 NW JCT I-5 | Concrete Arch - Deck (3 spans) | -- | 1927 | 2006 | 170.0 | 397.0 | Fair | 97.3 | 085446000000000 |
NBI report Bridgehunter | NISQUALLY ENTRANCE | VAN TRUMP CREEK | 10.8 miles northeast of N | Concrete Arch - Deck | -- | 1928 | -- | 56.1 | 56.1 | Fair | 45.0 | 9450003P0000000 |
NBI report Bridgehunter | SUNRISE ROAD | DEADWOOD CREEK | 0.6 miles southwest of jc | Concrete Slab | -- | 1929 | -- | 22.0 | 24.0 | Fair | 51.7 | 9450036P0000000 |
NBI report | SR 7 | CLOVER CREEK | 3.7 N JCT SR 507 | Concrete Slab | -- | 1929 | 1948 | 21.0 | 23.0 | Fair | 93.0 | 0003470A0000000 |
NBI report Bridgehunter | EAST LINCOLN AVE | PUYALLUP RIVER | 0.7 N JCT I-5 | Steel Truss - Thru (3 spans) | -- | 1929 | 2011 | 170.0 | 465.9 | Fair | 73.9 | 085015000000000 |
NBI report | East 11th Street | Milwaukee Way | Puyallup River Crossing | Steel Girder and floorbeam system (51 spans) | -- | 1930 | -- | 161.1 | 2181.2 | Poor | 40.5 | 088140000000000 |
NBI report Bridgehunter | SUNRISE ROAD | WHITE RIVER | 5.4 miles southwest of jc | Concrete Arch - Deck | -- | 1930 | -- | 89.9 | 89.9 | Fair | 46.1 | 9450028P0000000 |
NBI report Bridgehunter | SUNRISE ROAD | KLICKITAT CREEK | 0.9 MILES SOUTHWEST OF JC | Concrete Arch - Deck | -- | 1930 | -- | 80.1 | 80.1 | Fair | 47.8 | 9450035P0000000 |
NBI report | TACOMA AVENUE SO | NPRR &SO TACOMA WAY | 0.1 N I-5 UNDERCROSSING | Steel Girder and floorbeam system (6 spans) | -- | 1930 | 2016 | 94.2 | 333.0 | Good | 92.4 | 085121000000000 |
NBI report Bridgehunter | 66 AV E | PUYALLUP RIVER | 0.1 N JCT SR 410 | Steel Truss - Thru | -- | 1931 | -- | 308.1 | 345.2 | Fair | 38.4 | 082355000000000 |
NBI report Bridgehunter | SUNRISE ROAD | FRYINGPAN CREEK | 4.3 MILES SOUTHWEST OF JC | Steel Arch - Deck | -- | 1931 | -- | 128.0 | 234.9 | Poor | 56.0 | 9450027P0000000 |
NBI report Bridgehunter | WEST SIDE ROAD | ST. ANDREWS CREEK | 3.2 miles north of jct. P | Concrete Arch - Deck | -- | 1931 | -- | 25.9 | 25.9 | Fair | 73.5 | 9450029P0000000 |
NBI report Bridgehunter | WEST SIDE ROAD | SOUTH PUYALLUP RIVER | 3.2 miles north of jct. P | Concrete Arch - Deck | -- | 1931 | -- | 42.0 | 42.0 | Good | 78.3 | 9450030P0000000 |
NBI report | EAST 26TH STREET | CMSTP&P RR A TO C STREE | 0.4 N JCT I-5 &SR7 | Concrete Tee beam (9 spans) | -- | 1931 | 2003 | 49.9 | 323.2 | Fair | 70.0 | 085120000000000 |
NBI report | 320 ST E | SOUTH FORK MUCK CREEK | .47 E JCT SR7 | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1934 | -- | 28.9 | 59.1 | Good | 72.9 | 081441000000000 |
NBI report | SR 167 | BNSF RR | 0.7 N JCT I-5 | Concrete Tee beam (5 spans) | -- | 1934 | -- | 49.9 | 211.0 | Poor | 28.7 | 0001784A0000000 |
NBI report | BNSF RAILROAD | PACIFIC HWY SW | .8 NE JCT SR 5 | Steel Girder and floorbeam system | -- | 1935 | -- | 106.0 | -- | -- | -- | 081420000000000 |
NBI report | BNRR FT LEWIS SPUR | I-5 | 1.7 N THURSTON CO | Steel Girder and floorbeam system | -- | 1936 | -- | 90.9 | -- | -- | -- | 0002082A0000000 |
NBI report | BNRR PT DEFIANCE | I-5 | 0.9 N THURSTON CO | Steel Girder and floorbeam system | -- | 1936 | -- | 34.1 | -- | -- | -- | 0002108A0000000 |
NBI report | SR 162 | SPIKETON CREEK | 17.3 E JCT SR 410 | Concrete Box Beam or girders - Single or Spread (6 spans) | -- | 1936 | -- | 60.0 | 226.1 | Poor | 46.7 | 000000JP0000000 |
NBI report Bridgehunter | SR 302 | HENDERSON BAY | 10.6 E MASON CO | Concrete Box beam or girders - Multiple (5 spans) | NR listed | 1936 | 1966 | 190.0 | 549.9 | Poor | 29.6 | 000000JQ0000000 |
NBI report | 48 ST E | SQUALLY CREEK | 0.42 EAST JCT WALLER ROAD | Concrete Box Beam or girders - Single or Spread (5 spans) | -- | 1937 | -- | 89.9 | 265.1 | Good | 64.1 | 081681000000000 |
NBI report Bridgehunter | ALDER CUTOFF RD E | MASHELL RIVER | 0.8 E JCT SR 161 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1937 | -- | 106.0 | 162.1 | Fair | 48.0 | 083271000000000 |
NBI report Bridgehunter | EAST 34TH STREET | PACIFIC TO A ST | 0.2 S JCT I-5 | Concrete Arch - Deck | NR listed | 1937 | -- | 243.1 | 484.9 | Poor | 33.2 | 085122000000000 |
NBI report | KOLISCH RD E | CARBON RIVER | 00.6 E FAIRFAX RD | Wood Stringer/Multi-beam or girder | -- | 1937 | 1966 | 91.9 | 149.9 | Fair | 46.8 | 084735000000000 |
NBI report | BRIDGEPORT WY SW | CLOVER CREEK | .2 S JCT SR 5 | Concrete Tee beam | -- | 1937 | 1970 | 40.0 | 43.0 | Fair | 77.5 | 081214000000000 |
NBI report Bridgehunter | PACIFIC HWY SW | CLOVER CREEK | .5 NW JCT SR 5 | Concrete Slab | -- | 1937 | 1970 | 29.9 | 59.1 | Fair | 71.6 | 081239000000000 |
NBI report | PEDESTRIAN TRAIL | STATE ROUTE 410 | 3.4 E JCT SR 123 | Wood Stringer/Multi-beam or girder | -- | 1938 | -- | 35.1 | -- | -- | -- | 000000CG0000000 |
NBI report | SR 161 | RR & CITY STREETS | 0.6 N JCT SR 161/SR 167 | Concrete Tee beam (5 spans) | -- | 1938 | -- | 69.9 | 250.0 | Fair | 59.2 | 0002410A0000000 |
NBI report Bridgehunter | WASHINGTON ROUTE 1 | DEER CREEK | 9.9 miles north of park b | Concrete Arch - Deck | -- | 1938 | -- | 78.1 | 78.1 | Good | 49.4 | 9450022P0000000 |
NBI report | GRAVELLY LK DR SW | CLOVER CREEK | 1.5 NW JCT SR 5 | Prestressed Tee beam | -- | 1938 | 1958 | 45.9 | 47.9 | Good | 85.0 | 079845000000000 |
NBI report | 56 ST E | CLARKS CREEK | .7 S JCT SR410 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1939 | -- | 38.1 | 62.0 | Good | 59.3 | 082477000000000 |
NBI report | F STREET | CLOVER CREEK | GRID COORD ET389203 | Steel Stringer/Multi-beam or girder | -- | 1939 | -- | 34.1 | 34.1 | Fair | 100.0 | AFWAPQWY00004 |
NBI report | FAIRFAX FOREST RD | TOLMIE CREEK | 6.1 SE JCT SR 165 | Steel Stringer/Multi-beam or girder | -- | 1939 | -- | 87.9 | 165.0 | Fair | 70.7 | 080353000000000 |
NBI report | STEILACOOM BLVD SW | CHAMBERS CREEK | 1.0 W BRIDGEPORT | Concrete Tee beam | -- | 1939 | 1995 | 45.9 | 47.9 | Good | 43.0 | 084651000000000 |
NBI report Bridgehunter | East 11th Street | HYLEBOS WATERWAY | 4.2 N JCT I-5 | Steel Movable - Bascule | -- | 1939 | 2012 | 216.9 | 946.9 | Good | 62.2 | 0002376A0000000 |
NBI report | MCCARTHY BLVD | CLOVER CREEK | GRID COORD ET391202 | Steel Stringer/Multi-beam or girder | -- | 1940 | -- | 34.1 | 34.1 | Fair | 100.0 | DAPAFBCOR084009 |
NBI report Bridgehunter | 86 AV NW | LAY INLET / NELYAL CREEK | 3.0 W JCT SR16 | Concrete Slab (3 spans) | -- | 1941 | -- | 24.9 | 36.1 | Fair | 68.8 | 079848000000000 |
NBI report | IRR STEWART AV E | CLARKS CREEK | 0.1 S JCT 66 AVE E | Concrete Box beam or girders - Multiple (3 spans) | -- | 1941 | -- | 38.1 | 60.0 | Fair | 56.8 | 082473000000000 |
NBI report | 288 ST E | DRAINAGE DITCH | .42 W JCT SR161 | Concrete Slab | -- | 1942 | -- | 22.0 | 23.0 | Fair | 82.9 | 080114000000000 |
NBI report Bridgehunter | N WINNIFRED ST | BNSF RAILROAD | 51. N WINNIFRED ST | Concrete Box beam or girders - Multiple (5 spans) | NR listed | 1942 | 2003 | 75.1 | 214.9 | Good | 87.4 | 085457000000000 |
NBI report Bridgehunter | ALDER CUTOFF RD E | TACOMA EASTERN RAILROAD | 2.5 E JCT SR 161 | Concrete Slab (13 spans) | -- | 1946 | -- | 22.0 | 275.9 | Fair | 47.0 | 083151000000000 |
NBI report | ALDER CUTOFF RD E | TACOMA RAIL MNT. DIV. | 3.3 E JCT SR 161 | Concrete Slab | -- | 1946 | -- | 22.0 | 25.9 | Good | 92.4 | 083400000000000 |
NBI report | CHAMBERS CK RD W | CHAMBERS CREEK | 1.0 SO JCT 64 ST W | Concrete Slab (4 spans) | -- | 1946 | -- | 16.1 | 65.0 | Fair | 20.8 | 083952000000000 |
NBI report | JOHNS RD E | WILKESON CREEK | 00.66 E JCT SR165 | Concrete Box Beam or girders - Single or Spread (3 spans) | -- | 1946 | -- | 47.9 | 71.9 | Fair | 70.1 | 082656000000000 |
NBI report | 8 AV S | MUCK CREEK | 2.8 S JCT SR 507 | Concrete Slab | -- | 1947 | -- | 29.9 | 32.2 | Fair | 61.2 | 082768000000000 |
NBI report | EAST 34TH STREET | B STREET TO D STREET-SR7 | 0.25 S JCT I5 | Concrete Arch - Deck | -- | 1947 | -- | 274.0 | 549.9 | Good | 69.1 | 085127000000000 |
NBI report | SR 7 | SOUTH CREEK | 0.8 N JCT SR 702 | Concrete Slab (3 spans) | -- | 1947 | -- | 22.0 | 60.0 | Fair | 87.4 | 0003222A0000000 |
NBI report | SR 7 | MASHEL RIVER | 1.0 N JCT SR 161 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 1948 | -- | 107.9 | 194.9 | Fair | 76.1 | 0003404A0000000 |
NBI report Bridgehunter | NB SR 16 | TACOMA NARROWS | 5.1 N JCT I-5 | Steel Suspension (3 spans) | NR eligible | 1949 | -- | 2800.0 | 5978.3 | Fair | 43.8 | 0003418A0000000 |
NBI report Bridgehunter | SR 16 | ROSEDALE RD | 12.8 N JCT I-5 | Concrete Tee beam (3 spans) | -- | 1949 | -- | 69.9 | 163.1 | Fair | 67.4 | 0003639A0000000 |
NBI report Bridgehunter | SR 410 | WHITE RIVER | PIERCE CO LINE | Steel Truss - Thru | -- | 1949 | -- | 200.1 | 292.0 | Fair | 71.9 | 0003523A0000000 |
NBI report | SR 410 | PSPL CO CANAL | 1.1 E JCT SR 165 | Steel Girder and floorbeam system | -- | 1949 | -- | 109.9 | 116.1 | Fair | 65.9 | 0003592A0000000 |
NBI report | FRYAR AV | WHITE RIVER | 1.1 N JCT SR 410 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1949 | 1973 | 125.0 | 232.0 | Fair | 54.4 | 085417000000000 |
NBI report | 66 AV E | CLARKS CREEK | 0.7 S JCT SR 410 | Concrete Slab (3 spans) | -- | 1950 | -- | 25.9 | 70.9 | Poor | 72.5 | 082460000000000 |
NBI report | 66 AV E | CLARKS CREEK | 0.6 S JCT SR 410 | Concrete Slab (3 spans) | -- | 1950 | -- | 24.0 | 67.9 | Poor | 74.5 | 082466000000000 |
NBI report | B STREET | CLOVER CREEK | GRID COORD ET384211 | Concrete Arch - Deck | -- | 1950 | -- | 28.9 | 28.9 | Fair | 99.0 | AFWAPQWY00002 |
NBI report | CHAMBERS LAKE ROAD | MUCK CREEK | GRID COORD ET355067 | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 39.4 | 40.0 | Good | 75.9 | DAPFORLEW000006 |
NBI report | ELLSWORTH WDS RD | MUCK CREEK | GRID COORD ET302056 | Steel Stringer/Multi-beam or girder | -- | 1950 | -- | 39.4 | 40.0 | Fair | 70.4 | DANFORLEW000013 |
NBI report | I STREET | DRAINAGE CANAL | GRID COORD ET287177 | Concrete Culvert (2 spans) | -- | 1950 | -- | 10.8 | 24.0 | Fair | 100.0 | DAPFORLEW000015 |
NBI report | SEQUALITCHEW ROAD | SEQUALITCHEW CREEK | GRID COORD ET291177 | Concrete Culvert (3 spans) | -- | 1950 | -- | 8.9 | 27.9 | Fair | 100.0 | DAPFORLEW000011 |
NBI report | WHARF ROAD | DRAINAGE CANAL | GRID COORD ET275180 | Concrete Culvert | -- | 1950 | -- | 24.0 | 24.0 | Fair | 99.0 | DAPFORLEW000001 |
NBI report | McCUTCHEON RD E | FENNEL CREEK | 1.59 E JCT SR162 | Concrete Slab | -- | 1951 | -- | 25.9 | 29.9 | Good | 66.1 | 080587000000000 |
NBI report | WEBSTER RD E | DRAINAGE DITCH | .32 N JCT KPWN HY | Concrete Slab | -- | 1951 | 1972 | 24.0 | 24.9 | Good | 96.8 | 080190000000000 |
NBI report | 138 ST S | SPANAWAY CREEK | 1.1 W JCT SR7 | Concrete Channel beam | -- | 1952 | -- | 30.8 | 30.8 | Good | 56.0 | 082189000000000 |
NBI report | STEWART RD E | WHITE RIVER | 0.72 E JCT SR 167 | Concrete Tee beam (3 spans) | -- | 1952 | -- | 89.9 | 232.0 | Fair | 59.4 | 079672000000000 |
NBI report | WALLER RD E | CLOVER CREEK | 2.5 E JCT SR 7 | Concrete Tee beam | -- | 1952 | -- | 29.9 | 34.1 | Good | 64.1 | 081796000000000 |
NBI report | MOUNTAIN VIEW BLVD | SPANAWAY LAKE | .28 S JCT MLTRY R | Wood Stringer/Multi-beam or girder (2 spans) | -- | 1952 | 1966 | 49.9 | 103.0 | Fair | 49.7 | 082632000000000 |
NBI report | ROAD | HUCKLEBERRY CREEK | 0.4 MI W OF 73/7320 JCT | Concrete Frame (3 spans) | -- | 1952 | 2005 | 49.9 | 80.1 | Fair | 74.0 | 060507000001268 |
NBI report | 264 ST E | KAPOWSIN CREEK | 0.3 W ORVILLE ROAD | Concrete Slab | -- | 1953 | -- | 27.9 | 29.9 | Good | 85.5 | 084036000000000 |
NBI report | 332 ST E | SOUTH FORK MUCK CREEK | .19 E JCT SR7 | Concrete Slab (2 spans) | -- | 1953 | -- | 19.0 | 40.0 | Good | 70.5 | 081564000000000 |
NBI report | 8 AV E | SOUTH FORK MUCK CREEK | 4.8 S JCT SR 7 | Wood Stringer/Multi-beam or girder | -- | 1953 | -- | 29.9 | 32.2 | Fair | 59.7 | 084663000000000 |
NBI report | SKI PARK RD E | LYNCH CREEK | .2 N JCT SR161 | Concrete Tee beam | -- | 1953 | -- | 35.1 | 41.0 | Good | 68.3 | 081202000000000 |
NBI report | NISQUALLY BR. RD. | NISQUALLY RIVER | GRID COORD ET280038 | Prestressed Tee beam (4 spans) | -- | 1953 | 1985 | 112.9 | 252.6 | Fair | 79.9 | DAPFORLEW000010 |
NBI report | 352 ST E | TANWAX CREEK | .5 W JCT SR161 | Concrete Tee beam | -- | 1954 | -- | 27.9 | 29.9 | Fair | 64.4 | 082956000000000 |
NBI report | CRAMER RD NW | LOCKEY CREEK | 2.1 SW JCT SR 302 | Concrete Channel beam (3 spans) | -- | 1954 | -- | 20.0 | 60.0 | Poor | 27.4 | 084196000000000 |
NBI report Bridgehunter | FOX ISLD BR RD FI | HALE PASSAGE | 0.1 S WARREN DR NW | Concrete Tee beam (20 spans) | -- | 1954 | -- | 120.1 | 1950.2 | Poor | 7.6 | 083461000000000 |
NBI report | I-5 SBCD | 41ST DIVISION | 6.1 N THURSTON CO | Concrete Tee beam (3 spans) | -- | 1954 | -- | 69.9 | 157.2 | Fair | 67.5 | 0004495B0000000 |
NBI report | LYNCH CREEK RD E | LYNCH CREEK | .57 N JCT SR161 | Concrete Tee beam | -- | 1954 | -- | 49.9 | 170.0 | Fair | 56.0 | 081697000000000 |
NBI report Bridgehunter | NORTH HERRON RD NW | HERRON BAY | 3.2 W JCT KEY PENNINSULA | Concrete Slab (3 spans) | -- | 1954 | -- | 20.0 | 60.0 | Poor | 46.7 | 083726000000000 |
NBI report | ORVILLE RD E | TACOMA EASTERN RAILROAD | 4.0 E JCT SR 161 | Concrete Tee beam (4 spans) | -- | 1954 | -- | 36.1 | 144.0 | Fair | 70.0 | 080513000000000 |
NBI report | SOLO POINT ROAD | DRAINAGE CANAL | GRID COORD ET274191 | Concrete Culvert (2 spans) | -- | 1954 | -- | 12.1 | 24.9 | Fair | 87.5 | DAPFORLEW000002 |
NBI report | THORNE RD | I-5 | 8.6 N THURSTON CO | Concrete Tee beam (2 spans) | -- | 1954 | -- | 49.9 | 104.0 | Fair | 56.5 | 0004495D0000000 |
NBI report | WEBSTER RD E | SOUTH FORK MUCK CREEK | 1.33 NE JCT SR161 | Concrete Tee beam | -- | 1954 | -- | 34.1 | 36.1 | Good | 84.8 | 080931000000000 |
NBI report | I-5 | 41ST DIVISION DR | 6.1 N THURSTON CO | Concrete Tee beam (3 spans) | -- | 1954 | 1969 | 69.9 | 157.2 | Fair | 84.3 | 0004495A0000000 |
NBI report | BERKELEY ST | I-5 | 7.7 N THURSTON CO | Concrete Tee beam (2 spans) | -- | 1954 | 2016 | 49.9 | 104.0 | Fair | 72.3 | 0004495C0000000 |
NBI report | 304 ST E | DRAINAGE DITCH | 1.5 E JCT SR 7 | Concrete Slab (3 spans) | -- | 1955 | -- | 24.0 | 64.0 | Fair | 78.1 | 080292000000000 |
NBI report | BARNES BLVD | CLOVER CREEK | WEST OF BRIDGE 84010 | Steel Culvert (3 spans) | -- | 1955 | -- | 13.1 | 44.9 | Fair | 87.5 | AFWAPQWY00001 |
NBI report | ROAD | SILVER CREEK | 0.3MI E OF HY 410/7175JCT | Wood Stringer/Multi-beam or girder | -- | 1955 | 2003 | 44.9 | 52.8 | Fair | 61.1 | 060507000001298 |
NBI report | ROAD | WHITE RIVER | .1MI W OF HY 410/7160 JCT | Concrete Stringer/Multi-beam or girder (5 spans) | -- | 1955 | 2005 | 69.9 | 220.2 | Fair | 54.8 | 060507000001304 |
NBI report | CRYSTAL RVR RANCH | WHITE RIVER | 0.1 SO JCT SR 410 | Concrete Tee beam (3 spans) | -- | 1956 | -- | 80.1 | 125.0 | Good | 72.6 | 083187000000000 |
NBI report | FOOTHILLS TRAIL | ORTING PED OVER SR 162 | 10.6 E JCT SR 410 | Steel Girder and floorbeam system | -- | 1956 | -- | 9.5 | -- | -- | -- | 086429000000000 |
NBI report | SR 162 | S PRAIRIE CR | 15.3 E JCT SR 410 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1956 | -- | 80.1 | 120.1 | Good | 72.9 | 0005142A0000000 |
NBI report | ROAD | WHITE RIVER | 0.5 MI S OF HY 410/73 JCT | Concrete Frame (3 spans) | -- | 1956 | 1998 | 80.1 | 181.1 | Fair | 59.1 | 060507000001271 |
NBI report | 47TH AVE SW | I-5 | 11.3 N THURSTON CO | Concrete Box beam or girders - Multiple (4 spans) | -- | 1957 | -- | 90.9 | 316.9 | Fair | 64.7 | 0005523C0000000 |
NBI report Bridgehunter | 76 ST SW | TAYLOR BAY | 0.6 W JCT K PENNINSULA HW | Concrete Channel beam (7 spans) | -- | 1957 | -- | 25.9 | 185.0 | Fair | 79.0 | 083556000000000 |
NBI report Bridgehunter | DAY ISL BRIDGE RD | DAY ISLAND LAGOON | .6 W JCT GRDVW DR | Prestressed Stringer/Multi-beam or girder (12 spans) | -- | 1957 | -- | 71.9 | 600.1 | Fair | 35.8 | 080893000000000 |
NBI report | NEW YORK AVE | I-5 | 10.4 N THURSTON C0 | Concrete Slab (2 spans) | -- | 1957 | -- | 67.9 | 139.1 | Fair | 65.1 | 0005523A0000000 |
NBI report | SR 165 | GULCH NO 3 | 11.9 N RAINIER PARK | Wood Stringer/Multi-beam or girder (6 spans) | -- | 1957 | -- | 15.1 | 91.9 | Fair | 81.3 | 0005632A0000000 |
NBI report | SR 509 | DRY GULCH | 9.7 N JCT I-705 | Steel Stringer/Multi-beam or girder | -- | 1957 | -- | 29.9 | 236.9 | Fair | 69.8 | 0005358A0000000 |
NBI report | STEILACOOM DUPONT | I-5 | 4.1 N THURSTON CO | Concrete Slab (2 spans) | -- | 1957 | -- | 54.1 | 110.9 | Poor | 58.0 | 0005394A0000000 |
NBI report | WASHINGTON ROUTE 1 | PANTHER CREEK | 5.3 miles north of park b | Prestressed Tee beam (5 spans) | -- | 1957 | -- | 50.9 | 193.9 | Fair | 65.6 | 9450021P0000000 |
NBI report | I-5 | RAILROAD - LAUNDRY SPUR | 3.7 N THURSTON CO | Concrete Box beam or girders - Multiple (3 spans) | -- | 1957 | 1969 | 75.1 | 194.9 | Fair | 85.0 | 0005284A0000000 |
NBI report | I-5 | PENDLETON AVE | 4.4 N THURSTON CO | Concrete Slab | -- | 1957 | 1969 | 37.1 | 39.0 | Fair | 75.0 | 0005394B0000000 |
NBI report | SR 165 | GULCH NO 2 | 12.0 N RAINIER PARK | Wood Stringer/Multi-beam or girder (8 spans) | -- | 1957 | 1969 | 16.1 | 105.0 | Fair | 93.6 | 0005632B0000000 |
NBI report | SR 165 | GULCH NO 1 | 12.1 N RAINIER PARK | Wood Stringer/Multi-beam or girder (7 spans) | -- | 1957 | 1969 | 16.1 | 91.9 | Poor | 63.9 | 0005632C0000000 |
NBI report | I-5 | CLOVER CREEK | 10.9 N THURSTON CO | Concrete Slab (3 spans) | -- | 1957 | 1974 | 26.9 | 68.9 | Fair | 85.0 | 0005523B0000000 |
NBI report | SUNRISE ROAD | SHAW CREEK | 2.7 MILES SOUTHWEST OF JC | Prestressed Tee beam | -- | 1957 | 1982 | 64.0 | 65.9 | Fair | 67.1 | 9450025P0000000 |
NBI report | BRIDGEPORT WAY | I-5 | 11.1 N THURSTON CO | Concrete Box beam or girders - Multiple (4 spans) | -- | 1958 | -- | 87.9 | 294.0 | Fair | 76.6 | 0005582A0000000 |
NBI report | I-5 | S96TH ST | 0.6 N JCT SR 512 | Concrete Box beam or girders - Multiple | -- | 1958 | -- | 83.0 | 86.9 | Fair | 77.0 | 0005667A0000000 |
NBI report | I-5 | S 96TH ST | 0.6 N JCT SR 512 | Concrete Box beam or girders - Multiple | -- | 1958 | -- | 83.0 | 86.0 | Fair | 84.0 | 0005667B0000000 |
NBI report | LIGHT RAIL (ST) | I-5 | 11.5 N THURSTON CO | Steel Girder and floorbeam system | -- | 1958 | -- | 3.6 | -- | -- | -- | 0005801A0000000 |
NBI report Bridgehunter | NISQUALLY ENTRANCE | NISQUALLY RIVER | 11.7 MILES NORTHEAST OF N | Steel Girder and floorbeam system (3 spans) | -- | 1958 | -- | 303.2 | 743.1 | Fair | 32.0 | 9450005P0000000 |
NBI report | PERIMETER ROAD | CLOVER CREEK | GRID COORD ET403207 | Steel Culvert (2 spans) | -- | 1958 | -- | 11.8 | 26.6 | Fair | 98.0 | AFWAPQWY00007 |
NBI report | S 56TH ST | I-5 | 3.2 N JCT SR 512 | Concrete Slab (4 spans) | -- | 1958 | -- | 57.1 | 208.0 | Fair | 77.7 | 0005831A0000000 |
NBI report | S 84TH ST | I-5 | 1.4 N JCT SR 512 | Concrete Slab (2 spans) | -- | 1958 | -- | 68.9 | 141.1 | Fair | 65.5 | 0005667C0000000 |
NBI report | S TACOMA WAY | I-5 | 12.1 N THURSTON CO | Concrete Box beam or girders - Multiple (2 spans) | -- | 1958 | -- | 136.2 | 283.2 | Fair | 62.2 | 0005651A0000000 |
NBI report | SR 512 | I-5 | 12.7 N THURSTON CO | Concrete Slab (4 spans) | -- | 1958 | -- | 59.1 | 211.0 | Fair | 77.3 | 0005655A0000000 |
NBI report | S 74TH - S 72ND ST | I-5 | 2.1 N JCT SR 512 | Concrete Box beam or girders - Multiple (2 spans) | -- | 1958 | 1988 | 88.9 | 183.1 | Fair | 69.9 | 0005723A0000000 |
NBI report Bridgehunter | TACOMA-VASHON TRAF | PUGET SOUND | PT DEFIANCE-TACOMA | Wood Stringer/Multi-beam or girder (7 spans) | -- | 1958 | 1994 | 16.1 | 81.0 | Fair | 69.7 | 0012701A0000000 |
NBI report | ROAD | GREENWATER RIVER | 8.4 MI E OF HY 410/70 JCT | Concrete Frame (3 spans) | -- | 1958 | 2012 | 60.0 | 89.9 | Fair | 87.2 | 060507000001319 |
NBI report | GRAVELLY LAKE DR | BNRR (NP) | 9.7 N THURSTON CO | Concrete Slab | -- | 1959 | -- | 24.9 | 26.9 | Poor | 88.1 | 0005943B0000000 |
NBI report | GRAVELLY LAKE DRIV | I-5 | 9.7 N THURSTON CO | Concrete Slab (2 spans) | -- | 1959 | -- | 70.9 | 145.0 | Fair | 94.9 | 0005943A0000000 |
NBI report | PACIFIC HWY SW | SOUND TRANSIT RAILROAD | 00.1 MI E GRAV LK | Concrete Slab | -- | 1959 | -- | 36.1 | 41.0 | Good | 80.2 | 085646000000000 |
NBI report | STEELE ST | SR 512 | 0.6 E JCT I-5 | Concrete Slab (2 spans) | -- | 1959 | -- | 65.0 | 139.1 | Fair | 77.0 | 0005985A0000000 |
NBI report | I-5 | S M ST | 0.5 N JCT SR 16 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1959 | 1989 | 82.0 | 232.0 | Good | 82.9 | 0006088B0000000 |
NBI report | 16 AV S | LACAMAS CREEK | 8. SO JCT SR 507 | Steel Stringer/Multi-beam or girder | -- | 1960 | -- | 22.0 | 23.0 | Fair | 81.8 | 082186000000000 |
NBI report | 70TH AVE E | I-5 | 1.0 N JCT SR 99 | Concrete Box beam or girders - Multiple (4 spans) | -- | 1960 | -- | 111.9 | 374.0 | Good | 72.1 | 0006361A0000000 |
NBI report | C STREET | CLOVER CREEK | GRID COORD ET388204 | Prestressed Stringer/Multi-beam or girder | Closed | 1960 | -- | 57.4 | 57.4 | Poor | 60.9 | AFWAPQWY00003 |
NBI report | MOUNTS RD TO I-5 | BNRR | 2.0 N THURSTON CO | Concrete Slab | -- | 1960 | -- | 28.9 | 30.8 | Good | 69.3 | 0006274A0000000 |
NBI report | PORTER WAY | I-5, HYLEBOS CR | 1.6 N JCT SR 99 | Prestressed Stringer/Multi-beam or girder (13 spans) | -- | 1960 | -- | 86.0 | 615.2 | Fair | 82.6 | 0006443A0000000 |
NBI report | SOUTH M STREET | NPRR @S 30TH ST | 0.1 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1960 | -- | 89.9 | 170.0 | Good | 94.0 | 085112000000000 |
NBI report | W-N RAMP/STEWART R | SOATON CREEK | 3.6 N JCT SR 410 | Concrete Culvert (2 spans) | -- | 1960 | -- | 9.8 | 21.0 | Good | 80.5 | 002004270000000 |
NBI report | I-5 | HYLEBOS CREEK | 1.7 N JCT SR 99 | Concrete Slab (11 spans) | -- | 1960 | 2009 | 40.0 | 401.9 | Good | 88.8 | 0006379C0000000 |
NBI report | I-5 | HYLEBOS CREEK | 1.7 N JCT SR 99 | Concrete Slab (9 spans) | -- | 1960 | 2009 | 40.0 | 321.9 | Good | 90.0 | 0006379D0000000 |
NBI report | I-5 | HYLEBOS CREEK | 1.3 N JCT SR 99 | Concrete Slab (3 spans) | -- | 1960 | 2010 | 29.9 | 78.1 | Good | 90.2 | 0006361B0000000 |
NBI report | I-5 | HYLEBOS CREEK | 1.3 N JCT SR 99 | Concrete Slab (3 spans) | -- | 1960 | 2010 | 65.9 | 78.1 | Good | 84.7 | 0006361C0000000 |
NBI report | I-5 | WAPATO CREEK | 1.4 N JCT SR 167 | Concrete Slab (3 spans) | -- | 1960 | 2010 | 22.0 | 60.0 | Good | 89.9 | 0006379A0000000 |
NBI report | I-5 | WAPATO CREEK | 1.4 N JCT SR 167 | Concrete Slab (3 spans) | -- | 1960 | 2010 | 22.0 | 60.0 | Good | 84.4 | 0006379B0000000 |
NBI report Bridgehunter | MILWAUKEE AVENUE | PUYALLUP RIVER | 0.3 S JCT SR167 | Concrete Box beam or girders - Multiple | -- | 1961 | -- | 180.1 | 472.1 | Poor | 27.3 | 083608000000000 |
NBI report | PORT OF TACOMA RD | I-5 | 0.8 N JCT SR 167 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1961 | -- | 102.0 | 299.9 | Fair | 89.8 | 0006480A0000000 |
NBI report | SOUTH YAKIMA AVE | S TAC WAY/CENTER ST/NP R | 0.1 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (10 spans) | -- | 1961 | -- | 107.9 | 737.9 | Fair | 92.9 | 085111000000000 |
NBI report | SR 99, (54TH AV E) | I-5 | JCT I-5 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1961 | -- | 85.0 | 320.9 | Fair | 61.5 | 0006480B0000000 |
NBI report | 70TH AVE E | HYLEBOS CREEK | 1.0 N JCT SR 99 | Concrete Slab (3 spans) | -- | 1962 | -- | 32.2 | 84.0 | Good | 92.9 | 0006480C0000000 |
NBI report | I-5 | PUYALLUP R/RR/SR 167 | 0.2 N JCT SR 167 | Prestressed Stringer/Multi-beam or girder (16 spans) | -- | 1962 | -- | 101.1 | 1455.1 | Fair | 68.0 | 0006613B0000000 |
NBI report | I-5 | PORTLAND AVE | 1.1 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2010 | 91.9 | 215.9 | Fair | 83.6 | 0006792B0000000 |
NBI report | I-5 | PORTLAND AVE | 1.1 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2012 | 91.9 | 215.9 | Fair | 85.8 | 0006792A0000000 |
NBI report | I-5 | SR 167 NB | 1.2 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1962 | 2012 | 48.9 | 121.1 | Fair | 67.8 | 0006821A0000000 |
NBI report | 25 AV E | CLOVER CREEK | 2.1 SE JCT SR7 | Concrete Slab | -- | 1963 | -- | 21.0 | 23.0 | Fair | 57.9 | 081674000000000 |
NBI report | AINSWORTH AVE | SR 512 | 1.4 E JCT I-5 | Concrete Slab (4 spans) | -- | 1963 | -- | 59.1 | 212.0 | Fair | 73.1 | 0007024B0000000 |
NBI report | E L ST | I-5 | 0.8 N JCT SR 7 | Concrete Box beam or girders - Multiple (5 spans) | -- | 1963 | -- | 82.0 | 374.0 | Fair | 75.6 | 0006853A0000000 |
NBI report | MEMORY LN W | STREAM | .2 WJCT SUNSET BE. | Steel Stringer/Multi-beam or girder | -- | 1963 | -- | 48.9 | 51.8 | Good | 54.5 | 082143000000000 |
NBI report | SB RAMP TO SR 167 | SR 167 RAMP TO SB I-5 | 0.2 N JCT SR 167 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1963 | -- | 71.9 | 184.1 | Fair | 91.9 | 0006979E0000000 |
NBI report | SR 167 | DRAINAGE | 0.2 E JCT I-5 | Concrete Slab (4 spans) | -- | 1963 | -- | 22.0 | 86.0 | Good | 91.2 | 0006979G0000000 |
NBI report | SR 7 (PACIFIC AVE) | SR 512 | 5.2 N JCT SR 507 | Concrete Slab (2 spans) | -- | 1963 | -- | 55.1 | 112.9 | Good | 84.5 | 0007024A0000000 |
NBI report | I-5 | EAST T ST SEWER | 0.2 N JCT SR 167 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1963 | 1970 | 46.9 | 149.9 | Fair | 83.0 | 0006979B0000000 |
NBI report | SR 512 | PARK AVE | 2.0 E JCT I-5 | Concrete Slab | -- | 1963 | 1990 | 66.9 | 66.9 | Fair | 91.8 | 0007024C0000000 |
NBI report | ROAD | 28 MILE CREEK | 4.5 MI E OF HY 410/70 JCT | Concrete Frame (3 spans) | -- | 1963 | 2008 | 35.1 | 55.1 | Fair | 75.6 | 060507000001318 |
NBI report | I-5 | S-S RAMP I-705 TO SR 7 | 1.4 N JCT SR 16 | Concrete Box beam or girders - Multiple (4 spans) | -- | 1964 | -- | 85.0 | 271.0 | Good | 98.2 | 0007326C0000000 |
NBI report | I-5 HOV | I-705, SR 7, RAMPS, RR | 1.5 N JCT SR 16 | Concrete Box beam or girders - Multiple (10 spans) | -- | 1964 | -- | 100.1 | 817.0 | Fair | 87.9 | 0007326A0000000 |
NBI report | I-5 RAMP | CMSTPP RR | 0.2 N JCT I-5 | Concrete Slab | -- | 1964 | -- | 37.1 | 38.1 | Good | 96.6 | 0007326F0000000 |
NBI report | TACOMA RAIL RR | BROOKDALE RD E | 2.9 E SR 7 | Steel Girder and floorbeam system | -- | 1964 | -- | 8.2 | -- | -- | -- | 083246000000000 |
NBI report | I-5 | I-705, SR 7, RAMPS, RR | 1.5 N JCT SR 16 | Concrete Box beam or girders - Multiple (10 spans) | -- | 1964 | 1989 | 100.1 | 817.0 | Fair | 75.2 | 0007326B0000000 |
NBI report | ROAD | HUCKLEBERRY CREEK | 6.0 MI S OF HY 410/73 JCT | Concrete Box beam or girders - Multiple (3 spans) | -- | 1964 | 2014 | 85.0 | 122.7 | Fair | 69.3 | 060507000001272 |
NBI report | 8 AV S | TACOMA RAIL MTN DIV OC | .4 S JCT SR 507 | Concrete Tee beam (3 spans) | -- | 1965 | -- | 35.1 | 112.9 | Fair | 60.4 | 080852000000000 |
NBI report | CMSTPP RR ALLI | STATE ROUTE 512 | 1.4 E JCT SR 7 | Steel Girder and floorbeam system | -- | 1965 | -- | 89.9 | -- | -- | -- | 0007769D0000000 |
NBI report | I-5 | S-S RAMP I-705 TO SR 7 | 1.4 N JCT SR 16 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1965 | -- | 105.0 | 265.1 | Fair | 98.6 | 0007326D0000000 |
NBI report | I-5 | CMSTPR RR | 1.4 N JCT SR 16 | Concrete Box beam or girders - Multiple (4 spans) | -- | 1965 | -- | 67.9 | 225.1 | Fair | 97.6 | 0007505C0000000 |
NBI report | NO DATA ENTERED | COPPER CREEK | 0.4 MILE NORTH OF HWY 706 | Prestressed Stringer/Multi-beam or girder | -- | 1965 | -- | 60.0 | 64.0 | Good | 76.1 | 060304000000079 |
NBI report | PORTLAND AVE | SR 512 | 1.5 E JCT SR 7 | Concrete Slab (2 spans) | -- | 1965 | -- | 63.0 | 130.9 | Fair | 75.2 | 0007769E0000000 |
NBI report | S 30TH ST | S-S RAMP | 0.1 N JCT I-5 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1965 | -- | 86.9 | 192.9 | Fair | 94.5 | 0007505E0000000 |
NBI report | SR 7 NB | SR 7 SB | 5.6 N JCT SR 512 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1965 | -- | 85.0 | 230.0 | Good | 89.7 | 0007326E0000000 |
NBI report | SCHOOL BUS ROUTE | SR 512 | 1.3 E JCT SR 7 | Concrete Slab (4 spans) | -- | 1966 | -- | 66.9 | 226.1 | Good | 80.5 | 0007769C0000000 |
NBI report | SR 512 | GOLDEN-GIVENS RD | 0.9 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | -- | 64.0 | 153.9 | Fair | 33.2 | 0007769A0000000 |
NBI report | SR 512 | GOLDEN GIVEN RD E | 0.9 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1966 | -- | 64.0 | 153.9 | Fair | 33.8 | 0007769B0000000 |
NBI report | SR 7 NB | SR 7 SB, RAILROAD | 5.5 N JCT SR 512 | Concrete Box beam or girders - Multiple (5 spans) | -- | 1966 | -- | 146.0 | 688.0 | Fair | 57.6 | 0007505D0000000 |
NBI report | 218 AV E | CWA CANAL | 2.1 N JCT SR410 | Concrete Tee beam (3 spans) | -- | 1966 | 2004 | 125.0 | 125.0 | Good | 77.8 | 083513000000000 |
NBI report | ROAD | S PRAIRIE CREEK | 5.9 MI E OF SUNSET LAKE | Prestressed Stringer/Multi-beam or girder | -- | 1966 | 2005 | 41.3 | 43.3 | Good | 78.7 | 060507000001288 |
NBI report | VIETNAM VILLAGE RD | MUCK CREEK | GRID COORD ET395088 | Steel Stringer/Multi-beam or girder | -- | 1966 | 2011 | 39.0 | 40.4 | Fair | 84.7 | DAPFORLEW000007 |
NBI report | 10 AV S | CLOVER CREEK | .61 W JCT SR7 | Concrete Slab | -- | 1967 | -- | 29.9 | 34.1 | Fair | 86.0 | 082179000000000 |
NBI report | 320 ST E | SOUTH FORK MUCK CREEK | 1.25 E JCT SR7 | Concrete Channel beam | -- | 1967 | -- | 24.0 | 25.9 | Fair | 85.5 | 080781000000000 |
NBI report | BNRR FT LEWIS SPUR | I-5 | 1.7 N THURSTON CO | Steel Girder and floorbeam system | -- | 1967 | -- | 3.6 | -- | -- | -- | 0008134C0000000 |
NBI report | BNRR PT DEFIANCE | I-5 | 0.9 N THURSTON CO | Steel Girder and floorbeam system | -- | 1967 | -- | 73.2 | -- | -- | -- | 0008134B0000000 |
NBI report | E 38TH STEET | SR 7 | 4.8 N JCT SR 512 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1967 | -- | 80.1 | 512.2 | Fair | 94.9 | 0008006A0000000 |
NBI report | NISQUALLY ENTRANCE | KAUTZ CREEK | 3.4 MILES EAST OF NISQUAL | Concrete Tee beam (3 spans) | -- | 1967 | -- | 45.6 | 79.4 | Fair | 45.8 | 9450001P0000000 |
NBI report | NP RY | STATE ROUTE 410 | 0.5 E JCT SR 167 | Steel Girder and floorbeam system | -- | 1967 | -- | 60.0 | -- | -- | -- | 0008102B0000000 |
NBI report | OLD NISQUALLY RD | I-5 | 2.0 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1967 | -- | 68.9 | 138.1 | Good | 62.5 | 0008134D0000000 |
NBI report | PARK AV S | CLOVER CREEK | .25 W JCT SR7 | Concrete Slab | -- | 1967 | -- | 29.9 | 34.1 | Good | 92.1 | 081988000000000 |
NBI report | SR 165 | WILKESON CREEK | 17.2 N RAINIER PARK | Concrete Slab (3 spans) | -- | 1967 | -- | 32.2 | 83.0 | Good | 95.0 | 0008217A0000000 |
NBI report | TRAFFIC AVE | SR 410 | 0.4 E JCT SR 167 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1967 | -- | 65.0 | 217.9 | Good | 72.7 | 0008102A0000000 |
NBI report | TULE LAKE AV S | CLOVER CREEK | 1.0 W JCT SR7 | Concrete Slab | -- | 1967 | -- | 29.9 | 34.1 | Good | 87.5 | 082131000000000 |
NBI report | C ST S | CLOVER CREEK | .1 W JCT SR 7 | Concrete Slab | -- | 1967 | 1975 | 33.1 | 34.1 | Good | 90.1 | 082044000000000 |
NBI report | SR 162-VALLEY AVE | SR 410 | JCT SR 410 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1967 | 1992 | 65.0 | 237.9 | Fair | 76.8 | 0008102C0000000 |
NBI report | SR 509 | HYLEBOS CREEK | 4.0 N JCT I-705 | Concrete Slab (3 spans) | -- | 1967 | 1994 | 37.1 | 97.1 | Fair | 71.5 | 084942000000000 |
NBI report | I-5 | NISQUALLY OVERFLOW | 0.6 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1968 | -- | 100.1 | 400.0 | Fair | 90.2 | 0008134A0000000 |
NBI report | SR 410 | 166TH AVE | 1.0 E JCT SR 162 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1968 | -- | 62.0 | 147.0 | Fair | 94.4 | 0008402A0000000 |
NBI report | CANYON RD | SR 512 | 3.6 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1969 | -- | 76.1 | 248.0 | Good | 80.0 | 0008437D0000000 |
NBI report | I-5 | 41ST DIVISION DRIVE | 6.1 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 82.0 | 165.0 | Fair | 84.5 | 0008580A0000000 |
NBI report | I-5 NBCD | 41ST DIVISION DR | 6.1 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 88.9 | 171.9 | Fair | 91.0 | 0008580B0000000 |
NBI report | NISQUALLY ENTRANCE | TAHOMA CREEK | 1.2 MILES EAST OF NISQUAL | Prestressed Stringer/Multi-beam or girder | -- | 1969 | -- | 64.6 | 64.6 | Fair | 59.0 | 9450026P0000000 |
NBI report | S 25TH ST | SR 16 RAMPS/S SPRAGUE AV | 0.4 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (3 spans) | NR possible | 1969 | -- | 99.1 | 149.9 | Good | 86.2 | 0008543C0000000 |
NBI report | SR 162 | S PRAIRIE CREEK | 11.6 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 100.1 | 250.0 | Fair | 93.6 | 0008606A0000000 |
NBI report | SR 162 | S PRAIRIE CREEK | 12.8 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 100.1 | 227.0 | Good | 93.6 | 0008606B0000000 |
NBI report | SR 162 | S PRAIRIE CR | 13.2 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 100.1 | 225.1 | Good | 93.6 | 0008606C0000000 |
NBI report | SR 162 | S PRAIRIE CREEK | 13.6 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 100.1 | 216.9 | Good | 94.2 | 0008606D0000000 |
NBI report | SR 512 | WALLER RD | 2.1 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 65.9 | 160.1 | Good | 96.2 | 0008437A0000000 |
NBI report | SR 512 | WALLER RD | 2.1 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1969 | -- | 65.9 | 160.1 | Good | 96.2 | 0008437B0000000 |
NBI report | VICKERY AVE E | SR 512 | 2.8 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1969 | -- | 83.0 | 170.0 | Good | 77.6 | 0008437C0000000 |
NBI report | 133 ST S | CLOVER CREEK | .06 E JCT SR7 | Concrete Slab | -- | 1970 | -- | 41.0 | 45.9 | Good | 93.2 | 082019000000000 |
NBI report | 134 ST S | CLOVER CREEK | .2 E JCT SR7 | Concrete Slab | -- | 1970 | -- | 36.1 | 41.0 | Good | 92.1 | 082014000000000 |
NBI report | 45 ST E | LAKE TAPPS | 1. SE SUMNR TPS HY | Concrete Slab (7 spans) | -- | 1970 | -- | 29.9 | 206.0 | Fair | 71.9 | 081989000000000 |
NBI report | 75 ST W | FLETT CREEK | .1 W JCT 61 AVESW | Prestressed Stringer/Multi-beam or girder | -- | 1970 | -- | 120.1 | 125.0 | Good | 87.1 | 083470000000000 |
NBI report | 7TH AVE SW | CLARKS CREEK | 1.3 MI W SR 512 | Prestressed Tee beam | -- | 1970 | -- | 61.0 | 63.0 | Fair | 79.5 | 085747000000000 |
NBI report | A ST S | CLOVER CREEK | .12 E JCT SR7 | Concrete Slab | -- | 1970 | -- | 54.1 | 62.0 | Good | 92.1 | 082006000000000 |
NBI report | B ST E | NORTH FORK CLOVER CREEK | .23 E JCT SR7 | Concrete Slab | -- | 1970 | -- | 29.9 | 34.1 | Good | 92.1 | 081994000000000 |
NBI report | FOOTBRIDGE | SOUTH 48TH STREET | 00.1 EA JCT I-5 | Concrete Box Beam or girders - Single or Spread | -- | 1970 | -- | 74.2 | -- | -- | -- | 085267000000000 |
NBI report | SOUTH 48TH STREET | INTERSTATE HWY 5 | 0.0 INT. JCT I-5 | Prestressed Girder and floorbeam system (2 spans) | -- | 1970 | -- | 118.1 | 220.2 | Fair | 76.7 | 085261000000000 |
NBI report | SR 16 | ROSEDALE RD | 12.8 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1970 | -- | 81.0 | 233.0 | Good | 88.3 | 0008694A0000000 |
NBI report | SR 167 | CLARK'S CREEK | 3.7 N JCT I-5 | Concrete Slab (3 spans) | -- | 1970 | 1978 | 50.9 | 130.9 | Good | 91.5 | 0008682A0000000 |
NBI report | 31 AV CT E | CLEAR CREEK | 0.1 S JCT SR 410 | Prestressed Tee beam | -- | 1971 | -- | 40.0 | 43.0 | Good | 84.8 | 081191000000000 |
NBI report | SR 161 | SR 512 | 25.8 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | -- | 89.9 | 277.9 | Good | 34.9 | 0009010A0000000 |
NBI report | SR 167 | PUYALLUP RIVER | 0.2 S JCT SR 161 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1971 | -- | 129.9 | 541.0 | Fair | 76.8 | 0008903A0000000 |
NBI report | SR 167 | W-S RAMP | 0.2 N JCT SR 410 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1971 | -- | 105.0 | 233.9 | Fair | 92.0 | 0009075C0000000 |
NBI report | SR 410 | WHITE R (STUCK R) | 0.1 E JCT SR 167 | Prestressed Stringer/Multi-beam or girder | -- | 1971 | -- | 210.0 | 442.0 | Fair | 86.7 | 0008746A0000000 |
NBI report | SR 512 | WOODLAND AVE | 4.6 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 65.0 | 157.2 | Good | 95.9 | 0008673A0000000 |
NBI report | SR 512 | WOODLAND AVE | 4.6 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 65.0 | 157.2 | Good | 95.9 | 0008673B0000000 |
NBI report | SR 512 | FRUITLAND AVE | 5.0 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 65.0 | 157.2 | Good | 95.9 | 0008673C0000000 |
NBI report | SR 512 | FRUITLAND AVE | 5.0 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1971 | -- | 65.0 | 157.2 | Good | 95.9 | 0008673D0000000 |
NBI report | SR 512 | PUYALLUP R & CITY ST'S | 2.2 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1971 | -- | 220.2 | 1558.1 | Fair | 87.6 | 0009004A0000000 |
NBI report | UNION AVENUE SOUTH | NPRR &SOUTH TACOMA WAY | 0.9 E JCT I-5&38TH | Prestressed Stringer/Multi-beam or girder (18 spans) | -- | 1971 | -- | 80.1 | 1235.0 | Fair | 94.0 | 085284000000000 |
NBI report | 9TH ST SW/94TH AVE | SR 512 | 6.1 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1971 | 1995 | 104.0 | 284.1 | Fair | 44.4 | 0008673E0000000 |
NBI report | 12TH AVE SW | CLARKS CREEK | 1 MI WEST OF SR 512 | Prestressed Tee beam | -- | 1972 | -- | 65.0 | 66.9 | Fair | 91.0 | 085746000000000 |
NBI report | 56 AV S | LACAMAS CREEK | 1.2 E JCT SR 507 | Concrete Slab | -- | 1972 | -- | 23.0 | 24.9 | Fair | 96.9 | 084883000000000 |
NBI report | 7TH AVE SE | SR 512 | 2.1 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | -- | 100.1 | 275.9 | Good | 96.7 | 0009010D0000000 |
NBI report | BENSTON DRIVE E | SR 512 | 2.7 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | -- | 85.0 | 257.9 | Good | 91.9 | 0009075E0000000 |
NBI report | LAKEWOOD DR SW | FLETT CREEK | .5 N JCT SHR 1 | Prestressed Stringer/Multi-beam or girder | -- | 1972 | -- | 40.0 | 43.0 | Good | 74.4 | 084759000000000 |
NBI report | SR 167 | MILWAUKEE AVE | 0.4 N JCT SR 161 | Concrete Slab (3 spans) | -- | 1972 | -- | 62.0 | 143.1 | Good | 89.8 | 0009075A0000000 |
NBI report | SR 167 | WEST VALLEY HWY | 0.7 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | -- | 85.0 | 290.0 | Fair | 89.4 | 0009118A0000000 |
NBI report | WOLLOCHET DR NW | SR 16 | 12.0 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1972 | -- | 120.1 | 228.0 | Good | 82.9 | 0009380A0000000 |
NBI report | OLYMPIC DR NW | SR 16 | 10.7 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1972 | 1996 | 101.1 | 207.0 | Fair | 94.8 | 0009245A0000000 |
NBI report | SR 16 | CEDAR ST | 0.8 N JCT I-5 | Concrete Tee beam (3 spans) | -- | 1972 | 2002 | 79.1 | 199.2 | Fair | 85.9 | 0009151A0000000 |
NBI report | SR 16 | CEDAR ST | 0.6 N JCT I-5 | Concrete Tee beam (3 spans) | -- | 1972 | 2002 | 79.1 | 199.2 | Good | 89.4 | 0009151B0000000 |
NBI report | SR 16 | UNION AVE | 1.1 N JCT I-5 | Prestressed Frame (3 spans) | -- | 1972 | 2002 | 115.2 | 231.0 | Fair | 89.5 | 0009151C0000000 |
NBI report | SR 16 | UNION AVE | 1.1 N JCT I-5 | Prestressed Frame (3 spans) | -- | 1972 | 2002 | 115.2 | 231.0 | Good | 94.8 | 0009151D0000000 |
NBI report | SR 16 | TYLER ST - SNAKE LAKE | 1.6 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | 2006 | 138.1 | 483.0 | Fair | 94.8 | 0009415A0000000 |
NBI report | SR 16 | TYLER ST - SNAKE LAKE | 1.6 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1972 | 2006 | 136.2 | 512.2 | Good | 87.6 | 0009415B0000000 |
NBI report | PORTLAND AVE | PUYALLUP AVE NPRR | 0.2 N JCT I-5 PORT | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 1973 | -- | 125.0 | 960.0 | Fair | 81.4 | 085013000000000 |
NBI report | SR 162 | PUYALLUP RIVER | 0.5 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1973 | -- | 112.9 | 232.0 | Fair | 67.1 | 000000PA0000000 |
NBI report | SR 167 | S-E RAMP | 0.7 N JCT SR 512 | Concrete Slab (3 spans) | -- | 1973 | -- | 61.0 | 161.1 | Good | 88.0 | 0009075B0000000 |
NBI report | SR 167 | CITY STREETS & RR | 0.4 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 1973 | -- | 134.8 | 901.0 | Fair | 96.1 | 0009075D0000000 |
NBI report | SR 512 | 15TH AVE SW | 1.1 E JCT SR 161 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1973 | -- | 80.1 | 216.9 | Good | 87.2 | 0009010B0000000 |
NBI report | SR 512 | MERIDIAN ST | 1.3 E JCT SR 161 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1973 | -- | 100.1 | 236.9 | Good | 95.9 | 0009010C0000000 |
NBI report | CRYSTAL RVR RANCH | WHITE RIVER | 0.1 SO JCT SR 410 | Prestressed Tee beam | -- | 1973 | 1997 | 117.1 | 119.1 | Good | 81.0 | 083186000000000 |
NBI report | SCHUSTER PKWY | NORTH 30TH & BNRR | 2.0 N JCT SR509 | Prestressed Box Beam or girders - Single or Spread (7 spans) | -- | 1974 | -- | 120.1 | 779.9 | Good | 96.0 | 085577000000000 |
NBI report | SR 512 | 15TH AVE SW | 1.1 E JCT SR 161 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1974 | -- | 80.1 | 190.0 | Good | 93.8 | 0009619A0000000 |
NBI report | SR 512 | MERIDIAN ST | 1.3 E JCT SR 161 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1974 | -- | 101.1 | 213.9 | Good | 95.9 | 0009619B0000000 |
NBI report | TAC SPUR-SCHUST SB | SCHUSTER PKWY NB | 1.0 N JCT SR 509 | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 1974 | -- | 118.1 | 623.1 | Fair | 86.1 | 088852000000000 |
NBI report | TAC SPUR-SCHUST SB | SCHUSTER PKWY SB | 1.0 N JCT SR 509 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1974 | -- | 118.1 | 720.2 | Fair | 95.2 | 088853000000000 |
NBI report | TAC SPUR-STAD WAY | SCHUSTER PARKWAY | 1.0 N JCT SR 509 | Prestressed Stringer/Multi-beam or girder (10 spans) | -- | 1974 | -- | 118.1 | 856.0 | Fair | 85.7 | 084961000000000 |
NBI report | TAC SPUR-STADIUM N | SCHUSTER PARKWAY | 1.0 N JCT SR 509 | Prestressed Stringer/Multi-beam or girder (10 spans) | -- | 1974 | -- | 118.1 | 901.9 | Fair | 79.3 | 088854000000000 |
NBI report | UNION AVE/S TACOMA | I-5 SBCD | 12.5 N THURSTON CO | Prestressed Stringer/Multi-beam or girder | -- | 1974 | -- | 57.1 | 64.0 | Good | 79.2 | 0009574A0000000 |
NBI report | BARKUBIEN RD E | CWA CANAL | 1.0 E JCT 214 AV E | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1975 | -- | 85.0 | 170.0 | Good | 86.3 | 083492000000000 |
NBI report | FAIRFAX FOREST RD | EVANS CREEK | 2.9 SE SR165 | Prestressed Stringer/Multi-beam or girder | -- | 1975 | -- | 96.1 | 100.1 | Good | 79.7 | 084782000000000 |
NBI report | SR 512 | PUYALLUP R & CITY ST'S | 2.2 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder | -- | 1975 | -- | 125.0 | 1558.1 | Fair | 93.8 | 0009685A0000000 |
NBI report | SR 512 | SR 167 | 3.2 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1975 | -- | 124.0 | 337.0 | Good | 94.1 | 0009831A0000000 |
NBI report | STEELE ST | SR 512 | 0.6 E JCT I-5 | Concrete Slab (2 spans) | -- | 1975 | -- | 67.9 | 138.1 | Good | 75.0 | 000000PB0000000 |
NBI report | GROE RD E | LITTLE MASHELL RIVER | .3 E SCOTT TURNER | Steel Box Beam or girders - Single or Spread | -- | 1976 | -- | 60.0 | 62.0 | Fair | 64.1 | 083195000000000 |
NBI report | TULE LAKE CT S | CLOVER CREEK | 0.8 W JCT SR7 | Wood Stringer/Multi-beam or girder | -- | 1976 | 2016 | 30.8 | 32.2 | Good | 80.0 | 082286000000000 |
NBI report | 144TH ST NW | SR 16 | 1.5 N JCT SR 302 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1977 | -- | 107.9 | 210.0 | Fair | 82.0 | 0010280C0000000 |
NBI report | 154TH ST NW | SR 16 | 2.0 N JCT SR 302 | Concrete Box beam or girders - Multiple (2 spans) | -- | 1977 | -- | 110.9 | 214.9 | Good | 81.4 | 0010280D0000000 |
NBI report | SR 16 | N-W RAMP | 0.3 N JCT SR 302 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 112.9 | 251.0 | Good | 96.5 | 0010280A0000000 |
NBI report | SR 16 | N-W RAMP | 0.3 N JCT SR 302 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 97.1 | 208.0 | Good | 98.2 | 0010280B0000000 |
NBI report | SR 167 | 8TH ST E/STEWART AVE | 3.6 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 77.1 | 185.0 | Good | 90.0 | 0010558A0000000 |
NBI report | SR 302 SPUR | SR 16 | 1.3 E JCT SR 302 | Concrete Box beam or girders - Multiple (2 spans) | -- | 1977 | -- | 146.0 | 282.2 | Fair | 96.0 | 0010332A0000000 |
NBI report | SUMNER TAPPS HWY E | LAKE TAPPS OUTFALL PSE | .117F N TAPPS HWY | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1977 | -- | 69.9 | 214.9 | Fair | 56.2 | 080812000000000 |
NBI report | ALDER CUTOFF RD E | LITTLE MASHELL RIVER | 3.2 E JCT SR 161 | Prestressed Tee beam | -- | 1978 | -- | 69.9 | 75.1 | Good | 77.7 | 083403000000000 |
NBI report | SUMNER BUCKLEY HWY | PSE CANAL | 1.5 W JCT SR 410 | Prestressed Stringer/Multi-beam or girder | -- | 1978 | -- | 96.1 | 101.1 | Fair | 79.7 | 084539000000000 |
NBI report | CARBON RIVER ROAD | IPSUT CREEK | AT MP 4.89 ON CARBON RIVE | Prestressed Slab | Closed | 1979 | -- | 62.0 | 65.6 | Fair | 84.5 | 9450040P0000000 |
NBI report | SR 706 | GOAT CREEK | 12.2 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder | -- | 1979 | -- | 70.9 | 70.9 | Good | 80.1 | 0011420A0000000 |
NBI report | LEVITOW BLVD | CLOVER CREEK | GRID COORD ET385210 | Prestressed Stringer/Multi-beam or girder | -- | 1980 | -- | 83.0 | 86.9 | Good | 96.2 | AFWAPQWY00005 |
NBI report | PIONEER AVENUE SW | CLARKS CREEK | 0.15 E FRUITLAND | Prestressed Stringer/Multi-beam or girder | -- | 1980 | -- | 80.1 | 82.0 | Fair | 72.1 | 085493000000000 |
NBI report | CIRQUE DR W | LEACH CREEK | 0.4 W C/L TACOMA | Steel Culvert | -- | 1981 | -- | 45.9 | 45.9 | Good | 88.5 | 083084000000000 |
NBI report | EAST 43RD STREET | CMSTP&P RR C TO D ST | 1.7 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1981 | -- | 80.1 | 180.1 | Good | 98.7 | 085244000000000 |
NBI report | SR 165 | SO PRAIRIE CRK | 18.9 N RAINIER PARK | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1981 | -- | 283.2 | 570.9 | Good | 93.9 | 0011802A0000000 |
NBI report | EAST 23RD STREET | CITY WATERWAY- DOCK TO D | 01.0 NO. JCT I-5 | Prestressed Girder and floorbeam system (3 spans) | -- | 1983 | -- | 105.0 | 315.0 | Fair | 89.6 | 085023000000000 |
NBI report | I-5 | NISQUALLY OVERFLOW | 0.6 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1983 | -- | 100.1 | 400.0 | Fair | 84.0 | 0012137B0000000 |
NBI report | MURRAY RD E | TENAS CREEK | .129 S JCT SR706 | Wood Stringer/Multi-beam or girder | -- | 1983 | -- | 44.9 | 46.9 | Good | 64.3 | 084429000000000 |
NBI report | SR 16 | SR 163/PEARL ST | 3.7 N JCT I-5 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1983 | -- | 159.1 | 268.1 | Good | 96.8 | 0012245A0000000 |
NBI report | SR 16 | 6TH AVE | 3.5 N JCT I-5 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1983 | -- | 125.0 | 211.0 | Good | 97.1 | 0012245B0000000 |
NBI report | SR 410 | 166TH AVE | 1.0 E JCT SR 162 | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 95.1 | 95.1 | Good | 97.0 | 0012428A0000000 |
NBI report | SR 410 | ANGELINE RD | 3.5 E JCT SR 162 | Prestressed Stringer/Multi-beam or girder | -- | 1983 | -- | 101.1 | 106.0 | Good | 87.9 | 0012482A0000000 |
NBI report | BURNHAM DR NW | SR 16 | 14.9 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1984 | -- | 113.9 | 228.0 | Good | 98.7 | 0012617A0000000 |
NBI report | JACKSON AVE | SR 16 | 4.7 N JCT I-5 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1984 | -- | 148.0 | 255.9 | Good | 81.0 | 0012449A0000000 |
NBI report | YOMAN RD AI | BALCH PASSAGE | 0.1 NE VILLA BEACH | Prestressed Box Beam or girders - Single or Spread | -- | 1984 | -- | 89.9 | 344.2 | Good | 57.1 | 084498000000000 |
NBI report | 96 ST E | PUYALLUP RIVER | 0.66 E JCT SR 162 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1985 | -- | 129.9 | 380.9 | Good | 95.8 | 080405000000000 |
NBI report | IRR GAY RD E | BNSF RAILROAD | 0.1 NO PIONEER WAY | Prestressed Stringer/Multi-beam or girder | -- | 1985 | -- | 109.9 | 115.2 | Good | 97.9 | 081258000000000 |
NBI report | 15TH STREET | DOCK STREET | 2.0 NO JCT I-5 | Concrete Box Beam or girders - Single or Spread (5 spans) | -- | 1986 | -- | 69.9 | 420.0 | Good | 96.6 | 085445000000000 |
NBI report | I-705 | 15TH ST & BNRR,PRAIRIE L | 1.1 N JCT I-5 | Prestressed Box Beam or girders - Single or Spread (13 spans) | -- | 1986 | -- | 149.9 | 1910.2 | Good | 88.0 | 0012747A0000000 |
NBI report | LOWER BURNETT RD E | SOUTH PRAIRIE CREEK | 00.42 W JCT SR162 | Prestressed Tee beam | -- | 1986 | -- | 99.1 | 99.1 | Good | 79.6 | 082052000000000 |
NBI report | ROAD | E FK SOUTH PRAIRIE CREEK | 10.4 M E SUNSET LK (EST) | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 79.1 | 81.4 | Good | 71.6 | 060507000001282 |
NBI report | SKYLINE PED | SR 16 | 4.5 N JCT 1-5 | Prestressed Box beam or girders - Multiple | -- | 1986 | -- | 359.9 | -- | -- | -- | 084988000000000 |
NBI report | SR 16 | SOUTH 12TH STREET | 3.0 N JCT I-5 | Concrete Frame (3 spans) | -- | 1986 | -- | 89.9 | 193.9 | Good | 94.6 | 0012985A0000000 |
NBI report | SR 161 | LITTLE MASHELL RIVER | 1.8 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder | -- | 1986 | -- | 100.1 | 101.1 | Good | 98.8 | 0012982A0000000 |
NBI report Bridgehunter | SR 161 | MASHEL RIVER | 2.5 N JCT SR 7 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 1986 | -- | 100.1 | 164.1 | Good | 98.8 | 0013070A0000000 |
NBI report | 128 ST E | PUYALLUP RIVER | .64 E JCT SR162 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 138.1 | 411.1 | Good | 95.8 | 080557000000000 |
NBI report | I-705 | 15TH ST & BNRR | 1.1 N JCT I-5 | Prestressed Box beam or girders - Multiple (9 spans) | -- | 1987 | -- | 149.9 | 1245.1 | Good | 80.0 | 0012747B0000000 |
NBI report | I-705 N-W RAMP | 15TH ST-PLRR, I-705 | 0.9 N JCT I-5 | Prestressed Box beam or girders - Multiple (8 spans) | -- | 1987 | -- | 149.9 | 1242.2 | Good | 75.0 | 0012648A0000000 |
NBI report | I-705 RAMP | FLAT TERRAIN | 1.2 N JCT I-5 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1987 | -- | 109.9 | 220.2 | Good | 94.4 | 0012747C0000000 |
NBI report | S 15TH ST | N-N RAMP | 1.1 N JCT I-5 | Prestressed Box Beam or girders - Single or Spread (4 spans) | -- | 1987 | -- | 165.0 | 509.9 | Good | 99.5 | 0012648B0000000 |
NBI report | S 4TH STREET | DOCK STREET | 2.0 N JCT I-5 SR73 | Concrete Box beam or girders - Multiple (4 spans) | NR possible | 1987 | -- | 153.9 | 519.1 | Fair | 97.4 | 085586000000000 |
NBI report | SR 167 | S-E RAMP | 0.7 N JCT SR 512 | Concrete Slab (3 spans) | -- | 1987 | -- | 59.1 | 149.9 | Good | 95.4 | 0013042A0000000 |
NBI report | SR 167 | CITY STREETS & RR | 0.4 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 1987 | -- | 113.9 | 1012.2 | Fair | 66.8 | 0013042C0000000 |
NBI report | SR 167 | W VALLEY HWY | 0.7 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 83.0 | 290.0 | Good | 94.5 | 0013042D0000000 |
NBI report | SR 167 | 8TH ST E/STEWART AVE | 3.6 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1987 | -- | 77.1 | 185.0 | Fair | 95.6 | 0013042E0000000 |
NBI report | SR 512 | SR 167 | 3.2 E JCT SR 161 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1987 | -- | 120.1 | 337.9 | Good | 94.0 | 0013183A0000000 |
NBI report | 74TH - 72ND ST | S-W RAMP | 2.1 N JCT SR 512 | Concrete Slab | -- | 1988 | -- | 54.1 | 54.1 | Fair | 80.0 | 0013207A0000000 |
NBI report | CHAMBERS CK RD W | PEACH CREEK | 00.35MISW JCTBRPRT | Concrete Stringer/Multi-beam or girder (2 spans) | -- | 1988 | -- | 134.8 | 270.0 | Good | 91.5 | 085648000000000 |
NBI report | I-705 | CHEHALIS WESTERN RR | JCT I-5 | Prestressed Box beam or girders - Multiple (11 spans) | -- | 1988 | -- | 140.1 | 1451.2 | Good | 89.6 | 0012992A0000000 |
NBI report | I-705 NB | NB I-5 RAMP | 0.3 N JCT I-5 | Prestressed Box Beam or girders - Single or Spread (18 spans) | -- | 1988 | -- | 170.0 | 2588.1 | Fair | 80.7 | 0012992B0000000 |
NBI report | I-705 RAMP | TERRAIN | 0.2 N JCT I-5 | Prestressed Box Beam or girders - Single or Spread (3 spans) | -- | 1988 | -- | 154.9 | 418.0 | Fair | 94.6 | 0012992C0000000 |
NBI report | I-705 SB | CITY STREETS , RAILROAD | 0.2 N JCT I-5 | Prestressed Box beam or girders - Multiple (23 spans) | -- | 1988 | -- | 170.0 | 3364.0 | Good | 96.2 | 0012992D0000000 |
NBI report | I-705 SB | TERRAIN | 0.1 N JCT I-5 | Prestressed Box beam or girders - Multiple | -- | 1988 | -- | 125.0 | 125.0 | Good | 96.1 | 0012992E0000000 |
NBI report | OHOP VALLEY RD E | OHOP CREEK | 1.6 E JCT SR 7 | Prestressed Tee beam | -- | 1988 | -- | 56.1 | 59.1 | Good | 87.7 | 082202000000000 |
NBI report | SR 167 | W-S RAMP | 0.2 N JCT SR 410 | Concrete Box beam or girders - Multiple (3 spans) | -- | 1988 | -- | 120.1 | 270.0 | Fair | 95.1 | 0013042B0000000 |
NBI report | ROAD | GREENWATER RIVER | 0.3 MI N OF 70/7030 JCT | Prestressed Stringer/Multi-beam or girder | -- | 1989 | -- | 100.1 | 102.0 | Fair | 72.7 | 060507000001309 |
NBI report | TACOMA RAIL | SR 7 | 9.5 N JCT SR 702 | Steel Girder and floorbeam system | -- | 1989 | -- | 97.1 | -- | -- | -- | 0013397A0000000 |
NBI report | SOUTH 19TH ST | SR 16 | 2.6 N JCT I-5 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1992 | -- | 130.9 | 238.9 | Good | 92.4 | 0013783A0000000 |
NBI report | SR 162 | CARBON RIVER | 10.8 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 1992 | -- | 109.9 | 233.9 | Good | 84.8 | 00X3041A0000000 |
NBI report | SR 410 | ANGELINE RD | 3.5 E JCT SR 162 | Prestressed Stringer/Multi-beam or girder | -- | 1992 | -- | 101.1 | 106.0 | Fair | 93.2 | 0014032A0000000 |
NBI report | DAY USE ROAD | STREAM | DASH POINT STATE PARK | Concrete Arch - Deck | -- | 1993 | -- | 22.0 | 22.0 | Good | 69.7 | 086481000000000 |
NBI report | FRANK ALBERT RD E | UNION PACIFIC RAILROAD | 0.3 S JCT 20 ST E | Concrete Stringer/Multi-beam or girder | -- | 1993 | -- | 73.2 | 160.1 | Fair | 78.5 | 086638000000000 |
NBI report | SPANAWAY LOOP RD S | CLOVER CREEK | 1.0 S JCT SR 512 | Concrete Slab | -- | 1993 | -- | 38.1 | 39.0 | Good | 91.5 | 086064000000000 |
NBI report | SR 167 | MILWAUKEE AVE | 0.4 N JCT SR 161 | Concrete Slab (3 spans) | -- | 1993 | -- | 62.0 | 154.9 | Good | 97.9 | 0014126A0000000 |
NBI report | 33RD DIV & TANK TR | MUCK CREEK | GRID COORD ET338057 | Prestressed Box beam or girders - Multiple | -- | 1994 | -- | 41.0 | 42.0 | Good | 80.9 | DAPFORLEW000009 |
NBI report | IRR VALLEY AV E | WAPATO CREEK | 2.2 E JCT SR 5 | Prestressed Stringer/Multi-beam or girder | -- | 1994 | -- | 51.8 | 55.1 | Good | 91.5 | 086192000000000 |
NBI report | KERNAHAN RD E | NISQUALLY RIVER | .85 S JCT SR 706 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 1994 | -- | 168.0 | 336.0 | Good | 82.2 | 086089000000000 |
NBI report | TACOMA-VASHON TRAF | PUGET SOUND | PT DEFIANCE-TACOMA | Steel Movable - Lift | -- | 1994 | -- | 80.1 | 107.9 | Fair | 71.6 | 00X3158A0000000 |
NBI report Bridgehunter | WASHINGTON ROUTE 4 | DEADWOOD CREEK | 2.8 MILES NORTH OF JCT. W | Concrete Arch - Deck | -- | 1994 | -- | 148.0 | 273.0 | Fair | 63.5 | 9450024P0000000 |
NBI report | IRR VALLEY AVENUE | UNION PACIFIC RAILROAD | 2.2 E JCT SR 5 | Prestressed Box beam or girders - Multiple | -- | 1995 | -- | 214.9 | 662.1 | Fair | 81.9 | 086193000000000 |
NBI report | KEY PENINSULA HWY | VON GELDERN COVE | 5.2 S GIG HR | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1995 | -- | 83.0 | 320.9 | Good | 90.7 | 086191000000000 |
NBI report | NCO BEACH RD | AMERICAN LAKE | ET311172 | Concrete Culvert | -- | 1995 | -- | 20.0 | 20.0 | Good | 99.9 | DAPFORLEW008005 |
NBI report | SR 509 | WAPATO CREEK | 3.0 E JCT I-705 | Prestressed Box Beam or girders - Single or Spread | -- | 1995 | -- | 55.1 | 61.0 | Good | 97.4 | 0014414A0000000 |
NBI report | SR 512 RAMP | 92ND AVE | 6.1 E JCT SR 7 | Concrete Slab | -- | 1995 | -- | 41.0 | 43.0 | Good | 95.2 | 0014544A0000000 |
NBI report | FAIRFAX FOREST RD | POCH CREEK | 5.1 SE JCT SR 165 | Prestressed Slab | -- | 1996 | -- | 46.9 | 46.9 | Good | 77.1 | 086250000000000 |
NBI report | HERRON RD NW | VON GELDERN COVE INLET | .1 SW JCT SR302 | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 69.9 | 69.9 | Good | 99.6 | 086348000000000 |
NBI report | I-705 N-N RAMP | TERRAIN | JCT SR 509 | Prestressed Box beam or girders - Multiple (4 spans) | -- | 1996 | -- | 149.0 | 474.1 | Fair | 99.0 | 0014747C0000000 |
NBI report | LEBOR DEVORE RD E | SOUTH FORK MUCK CREEK | 1.74 E JCT SR7 | Prestressed Tee beam | -- | 1996 | -- | 49.9 | 55.1 | Good | 98.6 | 086205000000000 |
NBI report | PINCUS ROAD | MUCK CREEK | ET370083 | Concrete Culvert | -- | 1996 | -- | 29.9 | 29.9 | Good | 100.0 | DAPFORLEW000016 |
NBI report | SR 410 | SILVER CREEK | 13.4 E KING CO | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 97.1 | 100.1 | Good | 80.0 | 086262000000000 |
NBI report | SR 509 | MILWAUKEE WAY | 1.6 N JCT I-705 | Prestressed Stringer/Multi-beam or girder | -- | 1996 | -- | 129.9 | 134.8 | Good | 93.1 | 0014409A0000000 |
NBI report | SR 509 | RIVER, RR, PORTLAND AVE | 0.7 N JCT I-705 | Prestressed Segmental box girder (4 spans) | -- | 1996 | -- | 444.9 | 3584.2 | Good | 90.0 | 0014409B0000000 |
NBI report | SR 509 | I-705, BNRR, DOCK STREET | JCT I-705 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 1996 | -- | 150.9 | 311.0 | Good | 91.3 | 0014747A0000000 |
NBI report | SR 509 N-N RAMP | TERRAIN | JCT I-705 | Prestressed Box beam or girders - Multiple (2 spans) | -- | 1996 | -- | 101.1 | 198.2 | Good | 99.4 | 0014747B0000000 |
NBI report | SR 509 RAMP | RAILROAD & EAST RIVER ST | 0.7 N JCT I-705 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 1996 | -- | 140.1 | 997.1 | Good | 95.6 | 0014520A0000000 |
NBI report | SR 509 RAMP | RAILROAD | 0.7 N JCT I-705 | Prestressed Stringer/Multi-beam or girder (11 spans) | -- | 1996 | -- | 146.0 | 1170.0 | Good | 98.7 | 0014520B0000000 |
NBI report Bridgehunter | SR509 | THEA FOSS WATRWAY & D ST | 0.1 N JCT I-705 | Prestressed Stayed girder (2 spans) | -- | 1996 | -- | 350.1 | 992.2 | Fair | 88.5 | 0014507A0000000 |
NBI report | 118 AV NW | MINTER CREEK | 0.6 NO JCT SR 302 | Prestressed Slab | -- | 1997 | -- | 37.1 | 37.1 | Good | 94.0 | 086497000000000 |
NBI report | 30TH INF REGT RD | MUCK CREEK | ET406086 | Concrete Culvert | -- | 1997 | -- | 29.9 | 29.9 | Good | 100.0 | DAPFORLEW000017 |
NBI report | CENTER DR-FT LEWIS | TRUCK RAMP | 3.3 N THURSTON CO | Prestressed Stringer/Multi-beam or girder | -- | 1997 | -- | 91.9 | 99.1 | Good | 98.0 | 0014963D0000000 |
NBI report | CENTER DRIVE | I-5 | 2.5 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1997 | -- | 101.1 | 363.9 | Good | 86.9 | 0014963A0000000 |
NBI report | E. GATE RD/TANK TR | JOHNSON CREEK | GRID COORD ET378097 | Concrete Culvert | -- | 1997 | -- | 20.0 | 20.0 | Good | 89.4 | DAPFORLEW000008 |
NBI report | EAST VALLEY HWY E | CASCADE WATER TAILRACE | 3.1 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder | -- | 1997 | -- | 89.9 | 95.1 | Good | 90.4 | 086350000000000 |
NBI report | OHOP VALLEY EXT RD | OHOP CREEK | .85 SW JCT SR161 | Prestressed Stringer/Multi-beam or girder | -- | 1997 | -- | 92.9 | 98.1 | Good | 100.0 | 086294000000000 |
NBI report | ORTING KAPOWSIN HW | PUYALLUP RIVER | 0.7 S JCT SR 162 | Steel Stringer/Multi-beam or girder | -- | 1997 | -- | 214.9 | 455.1 | Fair | 67.8 | 086385000000000 |
NBI report | S-N RAMP | BN RR | 3.5 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1997 | -- | 128.9 | 512.2 | Good | 99.5 | 0014963C0000000 |
NBI report | S-S RAMP | BN RR | 3.1 N THURSTON CO | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 1997 | -- | 128.0 | 594.2 | Good | 97.5 | 0014963B0000000 |
NBI report | TACOMA RAIL RR | 112 ST E | 0.3 SO JCT SR 512 | Steel Girder and floorbeam system | -- | 1997 | -- | 9.2 | -- | -- | -- | 086349000000000 |
NBI report | FERRY LANDING | CORMORANT PASSAGE | 0.1 NO STEILACOOM | Prestressed Box Beam or girders - Single or Spread | -- | 1998 | -- | 101.1 | 191.9 | Good | 88.7 | 086346000000000 |
NBI report | FERRY LANDING | CORMORANT PASSAGE | KETRON ISLAND | Prestressed Box Beam or girders - Single or Spread | -- | 1998 | -- | 96.1 | 186.0 | Fair | 78.9 | 086347000000000 |
NBI report | ORVILLE RD E | PUYALLUP RIVER | 3.4 S JCT SR 162 | Prestressed Stringer/Multi-beam or girder | -- | 1998 | -- | 163.1 | 367.1 | Good | 92.4 | 086495000000000 |
NBI report | E MAIN STREET | PUYALLUP RIVER | 0.01 S JCT SR 410 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 1999 | -- | 120.1 | 394.0 | Fair | 88.5 | 086494000000000 |
NBI report | TACOMA AV E | WHITE RIVER | 1.4 N JCT SR410 | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 149.9 | 200.1 | Good | 98.3 | 086640000000000 |
NBI report | WRIGHT BLISS RD NW | EAST FORK ROCKY CREEK | 0.6 MI. NORTH ELGIN | Prestressed Stringer/Multi-beam or girder | -- | 1999 | -- | 60.0 | 60.0 | Good | 97.5 | 086496000000000 |
NBI report | KOPACHUCK DR NW | HENDERSON BAY INLET | 5.5 W JCT SR 16 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2000 | -- | 111.9 | 223.1 | Good | 99.3 | 086498000000000 |
NBI report | 38TH ST | I-5 | 4.3 N JCT SR 512 | Prestressed Box Beam or girders - Single or Spread (2 spans) | -- | 2001 | -- | 164.1 | 324.2 | Good | 95.9 | 0015935A0000000 |
NBI report | PED PATH | I-5 | 4.1 N JCT SR 512 | Prestressed Box Beam or girders - Single or Spread | -- | 2001 | -- | 15.1 | -- | -- | -- | 0015935B0000000 |
NBI report | PORT OF TACOMA RD | SR 509 | 1.7 N JCT I-705 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2001 | -- | 102.0 | 212.9 | Fair | 96.3 | 0015833A0000000 |
NBI report | PORT OF TACOMA RD | NFRC LINES | 1.7 N JCT I-705 | Concrete Box beam or girders - Multiple (5 spans) | -- | 2001 | -- | 98.1 | 432.1 | Fair | 82.6 | 0015833B0000000 |
NBI report | ROAD | CARBON RIVER | .1 MI N OF 78 / 7810 JCT. | Prestressed Stringer/Multi-beam or girder (6 spans) | -- | 2001 | -- | 116.5 | 702.1 | Fair | 61.0 | 060507000003032 |
NBI report | 20TH INFANTRY WAY | DRAINAGE CANAL | ET339079 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 24.3 | 28.2 | Good | 100.0 | DAPFORLEW000014 |
NBI report | 24TH ST | SR 16 | 8.8 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2003 | -- | 141.1 | 258.9 | Good | 96.2 | 0016441B0000000 |
NBI report | PED OVERPASS | I-705, BNSFRR, DOCK ST | 1.3 N JCT I-5 | Steel Stringer/Multi-beam or girder | -- | 2003 | -- | 10.5 | -- | -- | -- | 00LF006A0000000 |
NBI report | SR 167 | SOATON CREEK | 3.1 N JCT SR 410 | Steel Culvert (2 spans) | -- | 2003 | -- | 15.1 | 32.2 | Good | 70.0 | 0016597B0000000 |
NBI report | SR 167 SB OFF RAMP | SOATON CREEK | 2.1 N JCT SR 410 | Concrete Frame | -- | 2003 | -- | 35.1 | 35.1 | Good | 93.9 | 0016597C0000000 |
NBI report | 24TH ST E | SR 167, SOATON CK | 2.8 N JCT SR 410 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2004 | -- | 132.9 | 381.9 | Fair | 93.3 | 0016597A0000000 |
NBI report | NISQUALLY RD SW | BNSF RAILROAD OVERPASS | 1.1 S JCT SR 5 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2004 | -- | 191.9 | 642.1 | Good | 83.2 | 087173000000000 |
NBI report | ROAD | PYRAMID CREEK | 0.1 MI S OF 70/7033 JCT | Steel Stringer/Multi-beam or girder | -- | 2004 | -- | 78.1 | 80.4 | Good | 83.2 | 060507000003181 |
NBI report | SPANAWAY LOOP RD S | COFFEE CREEK | SOUTH SPANAWAY CREEK | Concrete Culvert | -- | 2004 | -- | 26.9 | 26.9 | Good | 86.9 | 087181000000000 |
NBI report | SR 162 | VOIGHTS CREEK | 8.9 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder | -- | 2004 | -- | 128.0 | 133.9 | Good | 90.4 | 0016635A0000000 |
NBI report | SR 167 ON RAMP SB | SOATON CREEK | 2.1 N JCT SR 410 | Concrete Frame | -- | 2004 | -- | 33.1 | 35.1 | Good | 98.1 | 0016597D0000000 |
NBI report | 118 AV NW | MINTER CREEK | 1.3 NO JCT SR 302 | Concrete Slab | -- | 2005 | -- | 25.9 | 27.9 | Good | 85.4 | 087268000000000 |
NBI report | 39TH AVE SE | WILLOWS POND OVERFLOW | .05 MI W JCT 5TH AVE | Prestressed Stringer/Multi-beam or girder | -- | 2005 | -- | 29.9 | 33.1 | Good | 76.0 | 088555000000000 |
NBI report | BRIDGEPORT WY W | LEACH CREEK | 0.25 SE JCT. 67TH AV | Steel Culvert | -- | 2005 | -- | 29.9 | 29.9 | Good | 82.0 | 087265000000000 |
NBI report | East 32nd Street | Lister Gulch | East 32nd Street | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2005 | -- | 155.8 | 330.1 | Good | 99.8 | 087420000000000 |
NBI report | POND ACCESS ROAD | STORMWATER POND | OFF 22 AV 0.7 SO JCT 176 | Concrete Slab | -- | 2005 | -- | 27.9 | 29.9 | Good | 76.0 | 087412000000000 |
NBI report | I-5 NCD | S M ST | 0.5 N JCT SR 16 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2006 | -- | 82.0 | 232.0 | Good | 94.9 | 0016958A0000000 |
NBI report | ORVILLE RD E | KAPOWSIN CREEK | 5.0 E Jct SR 161 | Prestressed Stringer/Multi-beam or girder | -- | 2006 | -- | 110.9 | 112.9 | Good | 88.6 | 087413000000000 |
NBI report | SB SR16 RMP CENTER | SR 16 | 1.9 N JCT I-5 | Steel Stringer/Multi-beam or girder (2 spans) | -- | 2006 | -- | 170.0 | 310.1 | Good | 97.1 | 0016767A0000000 |
NBI report | SR 16 | SOUTH 12TH STREET | 3.0 N JCT I-5 | Prestressed Stringer/Multi-beam or girder | -- | 2006 | -- | 128.9 | 134.8 | Good | 93.5 | 0016767C0000000 |
NBI report | SR 16 | 6TH AVE | 3.5 N JCT I-5 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2006 | -- | 125.0 | 211.0 | Good | 97.1 | 0016767D0000000 |
NBI report | SR 16 | SR 163/PEARL ST | 3.7 N JCT I-5 | Prestressed Box beam or girders - Multiple (3 spans) | -- | 2006 | -- | 159.1 | 269.0 | Good | 97.1 | 0016767E0000000 |
NBI report | 144 ST NW | ROCKY CREEK | 1.0 W JCT WRIGHR-BLISS RD | Concrete Culvert | -- | 2007 | -- | 29.9 | 29.9 | Good | 86.5 | 088245000000000 |
NBI report | DELIN STREET | I-5 | 1.0 N JCT SR 16 | Steel Box Beam or girders - Single or Spread (2 spans) | -- | 2007 | -- | 249.0 | 428.2 | Good | 98.7 | 0016958C0000000 |
NBI report | EAST L STREET | EAST 25TH STREET | 0.1 N JCT I-5 | Prestressed Tee beam (2 spans) | -- | 2007 | -- | 89.9 | 190.0 | Good | 98.9 | 088226000000000 |
NBI report | NISQUALLY ENTRANCE | KAUTZ CREEK | 3.5 MILES EAST OF NISQUAL | Steel Culvert (2 spans) | -- | 2007 | -- | 13.1 | 30.8 | Fair | 63.8 | 9450044P0000000 |
NBI report Bridgehunter | SB SR 16 | TACOMA NARROWS | 5.1 N JCT I-5 | Steel Suspension (3 spans) | -- | 2007 | -- | 2800.0 | 5570.2 | Good | 89.0 | 0016441A0000000 |
NBI report | THOMPSON/YAKIMA AV | I-5 | 0.9 N JCT SR 16 | Steel Box Beam or girders - Single or Spread (2 spans) | -- | 2007 | -- | 226.1 | 391.1 | Fair | 95.7 | 0016958B0000000 |
NBI report | 304 ST E | SOUTH FORK MUCK CREEK | .68 W JCT SR7 | Prestressed Tee beam | -- | 2008 | -- | 85.0 | 89.9 | Good | 82.9 | 087711000000000 |
NBI report | D Street | Railroad | East D St. | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2008 | -- | 109.9 | 211.0 | Good | 99.4 | 088268000000000 |
NBI report | 70 AV E | WAPATO CREEK | 0.1 S VALLEY AVE | Concrete Culvert | -- | 2009 | -- | 24.0 | 24.0 | Good | 82.1 | 088553000000000 |
NBI report | Shaw Road E | Inter Ave and BNSF R.R. | Shaw Road E. | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2009 | -- | 140.1 | 337.0 | Fair | 76.8 | 088375000000000 |
NBI report | STONE DR NW | TACOMA NARROWS AIRPORT | 0.07 W JCT 26TH AV NW | Concrete Culvert | -- | 2009 | -- | 63.0 | -- | -- | -- | 088347000000000 |
NBI report | SOUTH VAUGHN RD NW | VAUGHN BAY | 1.0 E JCT SR 302 | Concrete Stringer/Multi-beam or girder | -- | 2010 | -- | 213.9 | 219.2 | Good | 99.8 | 088161000000000 |
NBI report | SPRAGUE AVE | SR 16 | 0.37 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2010 | -- | 160.1 | 425.9 | Good | 92.8 | 0017594F0000000 |
NBI report | SR 16 S TO SPRAGUE | TERRAIN | 0.37 W JCT I-5 | Prestressed Stringer/Multi-beam or girder (3 spans) | -- | 2010 | -- | 153.9 | 316.0 | Good | 99.0 | 0017594E0000000 |
NBI report | 176 ST E | TACOMA EASTERN RAILROAD | 3.8 E JCT SR 7 | Prestressed Stringer/Multi-beam or girder | -- | 2011 | -- | 70.9 | 76.1 | Good | 96.0 | 088485000000000 |
NBI report | I-5 S-E RAMP | TERRAIN | WB NALLEY VALLEY | Prestressed Stringer/Multi-beam or girder (4 spans) | -- | 2011 | -- | 105.0 | 420.0 | Good | 96.6 | 0017594C0000000 |
NBI report | Lincoln Ave | E Marc St, Milwaukee Way | 0.6 NE JCT E Portland Ave | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 2011 | -- | 165.0 | 1154.9 | Good | 97.9 | 088378000000000 |
NBI report | N-E RAMP | CENTER STREET | WB NALLEY VALLEY | Prestressed Stringer/Multi-beam or girder (5 spans) | -- | 2011 | -- | 155.8 | 729.0 | Good | 95.1 | 0017594D0000000 |
NBI report | N-N RAMP | I-5 | JCT SR 16 | Prestressed Segmental box girder (4 spans) | -- | 2011 | -- | 295.0 | 1061.1 | Good | 96.2 | 0017594A0000000 |
NBI report | Port Auto Access | Lincoln Avenue ditch | S atThorne & Lincoln | Prestressed Slab | -- | 2011 | -- | 46.9 | 57.1 | Good | 99.9 | 088379000000000 |
NBI report | ROAD | HUCKLEBERRY CREEK | 0.1 MI SW OF 73/7305 JCT | Steel Stringer/Multi-beam or girder | -- | 2011 | -- | 89.9 | 91.2 | Good | 77.7 | 060507000016325 |
NBI report | SB I-5 TO NB SR 16 | S TACOMA WAY/STRR/CENTER | WB NALLEY VALLEY | Prestressed Stringer/Multi-beam or girder (14 spans) | -- | 2011 | -- | 167.0 | 2140.2 | Good | 93.9 | 0017594B0000000 |
NBI report | SR 16 | S TACOMA WAY/STRR/CENTER | 0.1 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (11 spans) | -- | 2011 | -- | 176.8 | 1609.0 | Good | 90.0 | 0017594I0000000 |
NBI report | WARREN DR NW | WARREN CREEK | 0.1 S 36TH ST NW | Metal Culvert | -- | 2011 | -- | 24.0 | 24.0 | Good | 99.9 | 088750000000000 |
NBI report | I-5 SBCD | SR 16 HOV AND RAMPS | 4.9 N JCT SR 512 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2013 | -- | 220.2 | 589.9 | Fair | 99.2 | 0018189B0000000 |
NBI report | MADIGAN AVENUE | MURRAY CREEK | SE OF JACKSON AVE | Concrete Culvert (2 spans) | -- | 2013 | -- | 13.1 | 27.9 | Good | 84.7 | DAPFORLEW0RV0MB |
NBI report | N HARBORVIEW DR | DONKEY CREEK | 0.05 NE JCT HARBORVIEW DR | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 71.9 | 77.1 | Good | 81.7 | 088655000000000 |
NBI report | SR 16 | S TACOMA WAY/STRR/CENTER | 0.1 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (8 spans) | -- | 2013 | -- | 194.9 | 1424.9 | Good | 93.9 | 0018189C0000000 |
NBI report | SR 16 W-N RAMP | CENTER ST/STRR | 0.3 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 2013 | -- | 182.1 | 975.1 | Good | 99.8 | 0018189D0000000 |
NBI report | SR 16 W-S RAMP | CENTER STREET & STRR | .30 W JCT I-5 | Prestressed Stringer/Multi-beam or girder (7 spans) | -- | 2013 | -- | 178.2 | 934.1 | Good | 99.1 | 0018189F0000000 |
NBI report | WARREN STREET | MUCK CREEK | 0.1 N JCT SR 507 | Prestressed Stringer/Multi-beam or girder | -- | 2013 | -- | 65.0 | 69.9 | Good | 98.9 | 088681000000000 |
NBI report | SR 16 | FUTURE HOV LANES | JCT I-5 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2014 | -- | 140.1 | 282.2 | Good | 96.2 | 0018189A0000000 |
NBI report | SR 7 | MUCK CREEK | 5.0 N JCT SR 702 | Concrete Frame | -- | 2014 | -- | 23.0 | 24.0 | Good | 91.4 | 0018444A0000000 |
NBI report | 288 ST S | LACAMAS CREEK | 2.6 E JCT SR507 | Prestressed Slab | -- | 2015 | -- | 41.0 | 45.9 | Good | 99.5 | 088836000000000 |
NBI report | CRYSTAL MNT BLVD | SILVER CREEK | 3.4 E JCT SR410 | Concrete Frame | -- | 2015 | -- | 32.2 | 32.2 | Good | 87.6 | 088947000000000 |
NBI report | JBLM ACCESS CORRID | E. LINCOLN/PERIMETER RD | BARNES BLDV | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2015 | -- | 183.4 | 367.1 | Fair | 95.3 | DAPFORLEW000018 |
NBI report | SR 162 | PUYALLUP RIVER | 4.4 E JCT SR 410 | Prestressed Stringer/Multi-beam or girder (2 spans) | -- | 2015 | -- | 154.9 | 270.0 | Good | 84.0 | 0018685A0000000 |
NBI report | SR 167 NB | PUYALLUP RIVER | 0.2 S JCT SR 161 | Steel Stringer/Multi-beam or girder (3 spans) | -- | 2015 | -- | 290.0 | 558.1 | Good | 92.2 | 0018513A0000000 |
NBI report | CRYSTAL MNT BLVD | SILVER CREEK | 4.67 E JCT 410 | Concrete Culvert | -- | 2016 | -- | 32.2 | 32.2 | Good | 77.4 | 088948000000000 |
NBI report | CRYSTAL MNT BLVD | SILVER CREEK | 5.85 E JCT 410 | Concrete Frame | -- | 2016 | -- | 28.9 | 28.9 | Good | 87.6 | 088949000000000 |
NBI report | I-5 | I-705, SR 7, RAMPS, RR | 1.5 N JCT SR 16 | Prestressed Girder and floorbeam system (5 spans) | -- | 2016 | -- | 170.0 | 717.9 | Good | 84.7 | 0018607C0000000 |
NBI report | N-N RAMP TO SR 167 | RAMP TO I-5 NB | 0.1 N JCT SR 167 | Steel Girder and floorbeam system (4 spans) | -- | 2016 | -- | 234.9 | 819.9 | Good | 98.8 | 0018670A0000000 |
NBI report | PACIFIC AVE | I-5 | 1.1 N JCT SR 16 | Prestressed Girder and floorbeam system (5 spans) | -- | 2016 | -- | 137.1 | 568.9 | Good | 72.5 | 0018607A0000000 |
NBI report | SR 161 | SOUTH CREEK | 12.9 N JCY SR 7 | Concrete Culvert | -- | 2016 | -- | 25.9 | 25.9 | Good | 78.5 | 0018869A0000000 |
NBI report | SR 507 | LACAMAS CREEK | 5.2 N JCT SR 702 | Concrete Slab | -- | 2016 | -- | 25.9 | 27.9 | Good | 93.4 | 0018867A0000000 |
NBI report | 8 AV E | NORTH FORK MUCK CREEK | 4.0 S JCT SR 7 | Prestressed Stringer/Multi-beam or girder | -- | 2017 | -- | 94.2 | 99.1 | Good | 97.2 | 088998000000000 |
NBI report | I-5 | PUYALLUP R/RR/SR 167 | 0.2 N JCT SR 167 | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 2017 | -- | 200.1 | 1570.0 | Good | 87.3 | 0018670B0000000 |
NBI report | I-5 NB | WN LINE | 5.0 N JCT SR 512 | Prestressed Stringer/Multi-beam or girder | -- | 2017 | -- | 150.9 | 155.8 | Good | 89.6 | 0018818A0000000 |
NBI report | PED TRAIL | SR 163 | 0.09 MI S PT DEF FERRY | Concrete Box Beam or girders - Single or Spread | -- | 2017 | -- | 11.8 | -- | -- | -- | 002005290000000 |
NBI report | BNSF RAILROAD | MOUNTS RD SW | 1.3 NORTH & WEST JCT. SR5 | Concrete Slab | -- | 2018 | -- | 19.0 | -- | -- | -- | 089060000000000 |
NBI report | SR 16 HOV LANES | S TACOMA WAY | 0.1 N JCT I-5 | Prestressed Stringer/Multi-beam or girder (4 spans) | New | 2018 | -- | 162.1 | 570.9 | Good | 96.0 | 0018818B0000000 |
NBI report | FISHING WARS XING | RAMP, RR, ROAD, TERRAIN | 0.01 E JCT PORTLAND AVE | Prestressed Stringer/Multi-beam or girder (9 spans) | -- | 2019 | -- | 115.2 | 1023.0 | -- | -- | 089074000000000 |