Share:

US93 SB; FAP35 over Burro Creek

Map

Coordinates:
+34.54540, -113.44510
34°32'43" N, 113°26'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US93 SB; FAP35 over Burro Creek
Structure number:00846
Location:43.8 mi NW Jct SR 71
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:680.2 ft. [207.3 m]
Total length:964.9 ft. [294.1 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:35.4 ft. [10.8 m]
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,748 [as of 2017]
Truck traffic:8% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:67.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$3,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairSatisfactorySatisfactoryFair374867.4
October 2016FairFairSatisfactorySatisfactory377177.5
October 2014FairFairSatisfactoryGood357377.6
November 2012FairFairSatisfactoryGood320077.6
November 2010FairFairSatisfactoryGood320062.0
June 2008FairFairSatisfactoryGood335062.0
December 2006FairFairFairGood330051.0
July 2004FairFairFairGood605454.9
November 2002FairSatisfactoryGoodGood601666.9
November 2000FairGoodSatisfactoryGood597066.9
June 1999FairGoodSatisfactoryGood529866.9
March 1998FairGoodSatisfactoryGood529866.9
May 1997GoodGoodGoodGood467166.9
May 1995GoodGoodGoodGood500066.9
January 1994GoodGoodGoodGood540066.9
June 1993GoodGoodGoodGood540066.9
April 1991FairGoodFairSatisfactory460053.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,4271,28214230
Steel Protective Coatingsq. ft.21,37521,16102140
Steel Stringerlinear ft.3,4013,3416000
Steel Protective Coatingsq. ft.22,100021,0001,1000
Deck
Reinforced Concrete Decksq. ft.34,16134,161000
Wearing Surfacessq. ft.30,88030,880000
Superstructure
Steel Archlinear ft.1,36152683230
Steel Protective Coatingsq. ft.95,250076,20014,2884,762
Steel Floor Beamlinear ft.1,13883830000
Steel Protective Coatingsq. ft.10,00010,000000
Steel Pin or Pin & Hangar Assemblyeach40400
Steel Gusset Plateeach288282600
Steel Protective Coatingsq. ft.2,8802,880000
Substructure
Steel Columneach4004000
Steel Protective Coatingsq. ft.26,292023,6641,3141,314
Reinforced Concrete Columneach20011
Reinforced Concrete Abutmentlinear ft.72472500
Reinforced Concrete Pier Caplinear ft.3019560
Joints
Strip Seal Jointlinear ft.128128000
Compression Jointlinear ft.128128000
Bearings
Movable Bearingeach1551000
Fixed Bearingeach1005337100
Bridge Rail