FDR 380 over PARK CREEK
Map
Coordinates:
+37.56523, -106.7220437°33'55" N, 106°43'19" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FDR 380 over PARK CREEK |
Structure number: | 020905000001179 |
Location: | 2.4 MI ON FDR 380 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 28.9 ft. [8.8 m] |
Total length: | 29.9 ft. [9.1 m] |
Roadway width between curbs: | 13.8 ft. [4.2 m] |
Deck width edge-to-edge: | 15.4 ft. [4.7 m] |
Owner: | U.S. Forest Service [64] |
Year built: | 1953 |
Historic significance: | Historical significance is not determinable at this time [4] |
Main span material: | Wood or timber [7] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 184 [as of 2003] |
Truck traffic: | 10% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 65.7 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Estimated cost of work: | $21,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Good | Fair | 184 | 65.7 |
August 2015 | Fair | Good | Good | Fair | 184 | 65.7 |
July 2013 | Fair | Satisfactory | Good | Fair | 184 | 65.7 |
June 2011 | Fair | Good | Good | Fair | 184 | 64.7 |
August 2009 | Fair | Good | Good | Fair | 184 | 64.7 |
May 2009 | Fair | Good | Good | Fair | 184 | 64.7 |