COUNTY ROAD 34 over FT. LYON CANAL
Map
Coordinates:
+38.25911, -102.7794238°15'33" N, 102°46'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COUNTY ROAD 34 over FT. LYON CANAL |
Structure number: | BT34-35-42.5-35 |
Location: | 1 MI N OF CR W |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 38.7 ft. [11.8 m] |
Total length: | 40.4 ft. [12.3 m] |
Roadway width between curbs: | 20.0 ft. [6.1 m] |
Deck width edge-to-edge: | 20.0 ft. [6.1 m] |
Owner: | County Highway Agency [02] |
Year built: | 1950 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Corrugated Steel [6] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: January 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 28 [as of 2018] |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 41.6 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $610,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2018 | Poor | Poor | Satisfactory | Poor | 28 | 41.6 |
January 2016 | Poor | Poor | Satisfactory | Poor | 24 | 39.3 |
January 2014 | Poor | Poor | Satisfactory | Poor | 24 | 37.2 |
January 2012 | Fair | Fair | Satisfactory | Fair | 27 | 51.2 |
January 2010 | Fair | Fair | Good | Fair | 37 | 51.2 |
January 2008 | Fair | Fair | Good | Satisfactory | 37 | 61.2 |
February 2006 | Fair | Fair | Good | Satisfactory | 37 | 61.2 |
January 2004 | Fair | Fair | Good | Good | 37 | 63.2 |
February 2001 | Fair | Fair | Good | Good | 37 | 62.3 |
February 1999 | Fair | Fair | Good | Good | 37 | 62.3 |
March 1997 | Fair | Fair | Good | Satisfactory | 37 | 62.3 |
March 1995 | Fair | Fair | Good | Satisfactory | 18 | 62.3 |
December 1993 | Fair | Fair | Good | Satisfactory | 18 | 60.4 |
November 1991 | Fair | Fair | Good | Satisfactory | 18 | 60.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 405 | 162 | 243 | 0 | 0 |
Substructure |
Steel Column | each | 10 | 0 | 0 | 10 | 0 |
Steel Abutment | linear ft. | 40 | 0 | 20 | 20 | 0 |
Steel Protective Coating | sq. ft. | 40 | 0 | 0 | 2 | 38 |
Steel Pier Cap | linear ft. | 40 | 0 | 40 | 0 | 0 |
Deck |
Corrugated or Orthotropic Deck | sq. ft. | 810 | 0 | 300 | 410 | 100 |
Wearing Surfaces | sq. ft. | 810 | 0 | 810 | 0 | 0 |
Steel Protective Coating | sq. ft. | 810 | 0 | 0 | 810 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 81 | 0 | 81 | 0 | 0 |
Steel Protective Coating | sq. ft. | 81 | 0 | 0 | 8 | 73 |