Share:

COUNTY ROAD 22.3 over CULEBRA CREEK

Map

Coordinates:
+37.16113, -105.37470
37°09'40" N, 105°22'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD 22.3 over CULEBRA CREEK
Structure number:CS242D-0.1-152A
Location:BETWEEN CR L.7 AND M.5
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:17.4 ft. [5.3 m]
Total length:40.4 ft. [12.3 m]
Roadway width between curbs:27.2 ft. [8.3 m]
Deck width edge-to-edge:29.5 ft. [9.0 m]
Skew angle:15°
Owner:County Highway Agency [02]
Year built:1984
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:106 [as of 2014]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:72.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairFairSatisfactoryFair10672.4
March 2015FairSatisfactorySatisfactoryFair10673.4
March 2013FairSatisfactoryGoodFair9874.4
March 2011FairSatisfactoryGoodFair9874.4
March 2009FairSatisfactoryGoodFair14773.4
February 2007FairSatisfactoryGoodSatisfactory14784.4
March 2005FairSatisfactoryGoodSatisfactory14784.4
June 2003FairSatisfactoryGoodSatisfactory14784.3
October 2001FairGoodGoodSatisfactory14784.3
April 2000FairGoodGoodSatisfactory14784.0
June 1999FairGoodGoodSatisfactory14784.0
June 1998FairGoodGoodSatisfactory14784.0
April 1996FairGoodGoodSatisfactory12284.0
March 1994FairGoodGoodSatisfactory12284.4
December 1992FairGoodGoodSatisfactory12284.4
January 1991GoodGoodGoodGood27084.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.605060500
Substructure
Masonry Pier Walllinear ft.3003000
Masonry Abutmentlinear ft.61322900
Deck
Corrugated or Orthotropic Decksq. ft.1,18501,0351500
Wearing Surfacessq. ft.1,02501,02500
Steel Protective Coatingsq. ft.1,18501,18500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.81621900
Steel Protective Coatingsq. ft.8108100