SH 101 ML over RULE CREEK
Map
Coordinates:
+37.81978, -103.1820537°49'11" N, 103°10'55" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 101 ML over RULE CREEK |
Structure number: | M-24-D |
Location: | 17.6 MI SO OF JCT US 50 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 41.0 ft. [12.5 m] |
Total length: | 202.8 ft. [61.8 m] |
Roadway width between curbs: | 24.9 ft. [7.6 m] |
Deck width edge-to-edge: | 28.5 ft. [8.7 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1939 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 5 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 70 [as of 2011] |
Truck traffic: | 25% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 62.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Fair | Satisfactory | Fair | 70 | 62.2 |
August 2016 | Fair | Fair | Satisfactory | Fair | 70 | 62.2 |
August 2014 | Fair | Fair | Satisfactory | Fair | 70 | 67.9 |
August 2012 | Fair | Fair | Satisfactory | Fair | 70 | 67.9 |
August 2010 | Fair | Fair | Satisfactory | Fair | 70 | 67.9 |
September 2008 | Fair | Fair | Satisfactory | Satisfactory | 70 | 79.0 |
September 2006 | Fair | Fair | Satisfactory | Satisfactory | 50 | 79.2 |
October 2004 | Fair | Fair | Satisfactory | Satisfactory | 53 | 79.2 |
September 2002 | Fair | Fair | Satisfactory | Satisfactory | 55 | 83.7 |
August 2000 | Fair | Fair | Satisfactory | Satisfactory | 64 | 78.8 |
December 1998 | Fair | Fair | Satisfactory | Satisfactory | 64 | 78.8 |
July 1996 | Fair | Fair | Fair | Fair | 50 | 67.8 |
July 1994 | Fair | Fair | Fair | Fair | 60 | 63.2 |
July 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 60 | 69.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,212 | 0 | 1,180 | 32 | 0 |
Steel Protective Coating | sq. ft. | 8,484 | 0 | 6,784 | 0 | 1,700 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,777 | 5,370 | 320 | 87 | 0 |
Wearing Surfaces | sq. ft. | 5,068 | 3,294 | 0 | 1,774 | 0 |
Substructure |
Reinforced Concrete Column | each | 24 | 5 | 19 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 66 | 32 | 21 | 13 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 132 | 100 | 9 | 23 | 0 |
Joints |
Pourable Joint | linear ft. | 58 | 58 | 0 | 0 | 0 |
Open Joint | linear ft. | 132 | 0 | 132 | 0 | 0 |
Bearings |
Movable Bearing | each | 30 | 0 | 30 | 0 | 0 |
Steel Protective Coating | sq. ft. | 180 | 0 | 0 | 0 | 180 |
Fixed Bearing | each | 30 | 0 | 30 | 0 | 0 |
Steel Protective Coating | sq. ft. | 180 | 0 | 0 | 0 | 180 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 406 | 296 | 100 | 10 | 0 |