Share:

COUNTY ROAD 4/105 over N. FORK-FRYING PAN RIVER

Map

Coordinates:
+39.34300, -106.66856
39°20'35" N, 106°40'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD 4/105 over N. FORK-FRYING PAN RIVER
Structure number:PIT-004-26.3A
Location:5 MI E OF REUDI RESERVOIR
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:46.9 ft. [14.3 m]
Total length:50.2 ft. [15.3 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:32.5 ft. [9.9 m]
Skew angle:16°
Owner:County Highway Agency [02]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Other [9]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:69 [as of 2014]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:93.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016GoodGoodGoodGood6993.5
May 2012GoodGoodGoodGood3393.8
May 2010GoodGoodGoodGood3393.7
May 2006GoodGoodVery GoodGood21493.0
August 2001GoodVery GoodVery GoodVery Good21493.0
July 1999GoodVery GoodVery GoodVery Good21493.0
July 1997GoodExcellentExcellentExcellent21493.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.301301000
Deck
Reinforced Concrete Top Flangesq. ft.1,6321,632000
Wearing Surfacessq. ft.1,6321,5508200
Substructure
Reinforced Concrete Abutmentlinear ft.6863500
Joints
Other Jointlinear ft.25114410700
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.100100000
Steel Protective Coatingsq. ft.100505000