US98 SR30 over ICWW & Brooks ST.
Map
Coordinates:
+30.40109, -86.6005630°24'04" N, 86°36'02" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US98 SR30 over ICWW & Brooks ST. |
Structure number: | 570034 |
Location: | 0.5mi. East of SR85 |
Purpose: | Carries highway and pedestrian walkway over highway and waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 200.1 ft. [61.0 m] |
Total length: | 1318.0 ft. [401.7 m] |
Roadway width between curbs: | 56.1 ft. [17.1 m] |
Deck width edge-to-edge: | 70.2 ft. [21.4 m] |
Vertical clearance below bridge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1964 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 51,000 [as of 2016] |
Truck traffic: | 3% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 49.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Poor | Fair | Poor | Fair | 51000 | 49.0 |
October 2015 | Poor | Fair | Poor | Fair | 51843 | 49.0 |
October 2013 | Poor | Fair | Poor | Fair | 50508 | 49.0 |
October 2011 | Fair | Satisfactory | Satisfactory | Fair | 48029 | 64.0 |
October 2009 | Fair | Good | Satisfactory | Satisfactory | 48282 | 75.0 |
October 2007 | Fair | Good | Satisfactory | Satisfactory | 53040 | 75.0 |
October 2005 | Fair | Good | Satisfactory | Satisfactory | 55170 | 75.0 |
October 2003 | Fair | Good | Satisfactory | Satisfactory | 53975 | 75.0 |
October 2001 | Fair | Good | Satisfactory | Satisfactory | 50344 | 75.0 |
October 1999 | Fair | Good | Satisfactory | Satisfactory | 48350 | 75.0 |
October 1997 | Fair | Good | Satisfactory | Satisfactory | 48200 | 75.0 |
June 1996 | Fair | Good | Satisfactory | Satisfactory | 53500 | 73.0 |
May 1994 | Fair | Good | Satisfactory | Fair | 50000 | 62.0 |
July 1992 | Fair | Good | Satisfactory | Fair | 47524 | 62.0 |
August 1990 | Fair | Good | Satisfactory | Fair | 44397 | 61.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 3,920 | 2,740 | 747 | 433 | 0 |
Steel Protective Coating | sq. ft. | 77,299 | 69,569 | 0 | 0 | 7,730 |
Prestressed Concrete Girder/Beam | linear ft. | 11,312 | 11,279 | 23 | 10 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 92,391 | 0 | 92,267 | 124 | 0 |
Substructure |
Steel Column | each | 12 | 12 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,389 | 2,389 | 0 | 0 | 0 |
Reinforced Concrete Column | each | 8 | 0 | 0 | 8 | 0 |
Reinforced Concrete Abutment | linear ft. | 140 | 130 | 10 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 120 | 90 | 20 | 10 | 0 |
Steel Pier Cap | linear ft. | 134 | 134 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,487 | 1,487 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 805 | 730 | 10 | 65 | 0 |
Joints |
Pourable Joint | linear ft. | 701 | 0 | 701 | 0 | 0 |
Open Joint | linear ft. | 145 | 145 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 160 | 109 | 27 | 0 | 24 |
Steel Protective Coating | sq. ft. | 724 | 524 | 0 | 0 | 200 |
Fixed Bearing | each | 144 | 92 | 0 | 4 | 48 |
Steel Protective Coating | sq. ft. | 488 | 408 | 0 | 0 | 80 |