Share:

SR115SB TO SR113NB over (SR-10A) ARLINGTON EXWY.

Map

Coordinates:
+30.32355, -81.56031
30°19'25" N, 81°33'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR115SB TO SR113NB over (SR-10A) ARLINGTON EXWY.
Structure number:720686
Location:SR-115 TO SR-113 RAMP
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:372.1 ft. [113.4 m]
Total length:1551.9 ft. [473.0 m]
Roadway width between curbs:30.5 ft. [9.3 m]
Deck width edge-to-edge:33.5 ft. [10.2 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:2007
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:11,000 [as of 2016]
Truck traffic:13% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:94.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017GoodGoodGoodGood1100094.4
December 2015GoodGoodGoodGood4100090.0
December 2013GoodGoodGoodGood2125095.0
December 2011GoodGoodGoodGood2200098.0
December 2009GoodVery GoodVery GoodVery Good2150097.0
December 2007GoodExcellentExcellentExcellent330097.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Closed Web/Box Girderlinear ft.3,1042,92218200
Steel Protective Coatingsq. ft.167,616164,2643,35200
Deck
Reinforced Concrete Decksq. ft.52,14751,99715000
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.6761510
Reinforced Concrete Pier Caplinear ft.9890800
Joints
Assembly with Sealeach61283003
Bearings
Pot Bearingeach124800
Steel Protective Coatingsq. ft.7064600
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3,1043,0188510