SR91 SB TPK 134.32 over SR 91 TPK (STUART INT)
Map
Coordinates:
+27.15778, -80.3021727°09'28" N, 80°18'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR91 SB TPK 134.32 over SR 91 TPK (STUART INT) |
Structure number: | 890068 |
Location: | STUART TPK INTERCHANGE |
Purpose: | Carries highway overpass over highway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Tolls: | Yes, on toll road [2] |
Length of largest span: | 58.1 ft. [17.7 m] |
Total length: | 168.0 ft. [51.2 m] |
Roadway width between curbs: | 36.1 ft. [11.0 m] |
Deck width edge-to-edge: | 41.0 ft. [12.5 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | State Toll Authority [31] |
Year built: | 1957 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: December 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,550 [as of 2017] |
Truck traffic: | 14% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 88.5 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Estimated cost of work: | $140,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2017 | Fair | Satisfactory | Satisfactory | Good | 1550 | 88.5 |
December 2015 | Fair | Satisfactory | Satisfactory | Good | 1300 | 88.8 |
December 2013 | Fair | Satisfactory | Satisfactory | Good | 1200 | 88.9 |
December 2011 | Fair | Satisfactory | Satisfactory | Good | 7100 | 82.9 |
December 2009 | Fair | Satisfactory | Satisfactory | Good | 7100 | 82.9 |
December 2007 | Fair | Satisfactory | Satisfactory | Good | 7100 | 82.9 |
December 2005 | Poor | Satisfactory | Poor | Good | 7100 | 47.2 |
February 2005 | Poor | Satisfactory | Poor | Good | 7100 | 55.1 |
December 2003 | Poor | Satisfactory | Poor | Good | 7100 | 55.1 |
December 2001 | Fair | Satisfactory | Satisfactory | Good | 7100 | 85.4 |
January 2000 | Fair | Satisfactory | Satisfactory | Good | 7100 | 85.4 |
January 1998 | Fair | Satisfactory | Good | Good | 7100 | 85.4 |
October 1995 | Fair | Satisfactory | Good | Good | 7100 | 85.3 |
October 1993 | Fair | Satisfactory | Good | Satisfactory | 4456 | 86.6 |
September 1991 | Fair | Satisfactory | Good | Satisfactory | 4456 | 77.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,180 | 1,130 | 50 | 0 | 0 |
Steel Protective Coating | sq. ft. | 9,951 | 9,901 | 50 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 6,889 | 6,755 | 132 | 2 | 0 |
Substructure |
Reinforced Concrete Column | each | 9 | 8 | 0 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 85 | 85 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 128 | 128 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 164 | 164 | 0 | 0 | 0 |
Assembly with Seal | each | 39 | 39 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 54 | 52 | 2 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 335 | 335 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 335 | 335 | 0 | 0 | 0 |