EB Spanish Rvr Bvd over Intracoastal Waterway
Map
Coordinates:
+26.38632, -80.0709326°23'11" N, 80°04'15" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | EB Spanish Rvr Bvd over Intracoastal Waterway |
Structure number: | 930226 |
Location: | EB SR800 .2mi West of A1A |
Purpose: | Carries highway and pedestrian walkway over highway and waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 111.9 ft. [34.1 m] |
Total length: | 486.9 ft. [148.4 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 36.1 ft. [11.0 m] |
Vertical clearance above deck: | 18.4 ft. [5.6 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1971 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Movable - Bascule [16] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 8,600 [as of 2018] |
Truck traffic: | 2% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 62.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 8600 | 62.5 |
November 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 8800 | 63.1 |
November 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 9200 | 61.1 |
November 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 7800 | 56.6 |
November 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 7250 | 57.9 |
November 2009 | Fair | Satisfactory | Satisfactory | Good | 6800 | 61.6 |
November 2008 | Fair | Satisfactory | Satisfactory | Good | 7050 | 61.6 |
November 2006 | Fair | Satisfactory | Satisfactory | Good | 7850 | 61.5 |
November 2005 | Fair | Satisfactory | Satisfactory | Good | 8250 | 62.2 |
November 2004 | Fair | Satisfactory | Satisfactory | Good | 7950 | 62.2 |
November 2002 | Fair | Satisfactory | Good | Good | 8350 | 62.2 |
December 2001 | Good | Good | Good | Good | 8050 | 63.2 |
November 2000 | Good | Good | Good | Good | 8400 | 73.5 |
October 1998 | Good | Good | Good | Good | 7500 | 77.6 |
July 1997 | Good | Good | Good | Good | 8500 | 77.0 |
July 1996 | Fair | Good | Satisfactory | Satisfactory | 8500 | 77.0 |
February 1994 | Fair | Good | Satisfactory | Good | 6373 | 77.4 |
November 1991 | Fair | Good | Satisfactory | Good | 5933 | 76.0 |
June 1990 | Fair | Fair | Satisfactory | Good | 6849 | 74.9 |