SR804 E Ocean Ave. over Intracoastal Waterway
Map
Coordinates:
+26.52704, -80.0539726°31'37" N, 80°03'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR804 E Ocean Ave. over Intracoastal Waterway |
Structure number: | 930370 |
Location: | 1 Mile S of Boynton Inlet |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 150.6 ft. [45.9 m] |
Total length: | 355.0 ft. [108.2 m] |
Roadway width between curbs: | 38.4 ft. [11.7 m] |
Deck width edge-to-edge: | 54.8 ft. [16.7 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Skew angle: | 7° |
Owner: | State Highway Agency [01] |
Year built: | 2001 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel [3] |
Main span design: | Movable - Bascule [16] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,100 [as of 2017] |
Truck traffic: | 5% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 92.6 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Very Good | Satisfactory | Very Good | 6100 | 92.6 |
April 2015 | Fair | Very Good | Satisfactory | Very Good | 6100 | 92.6 |
April 2013 | Good | Very Good | Good | Very Good | 6100 | 92.6 |
May 2011 | Good | Very Good | Good | Very Good | 5200 | 93.3 |
May 2009 | Good | Very Good | Very Good | Very Good | 11600 | 92.4 |
May 2008 | Good | Very Good | Very Good | Very Good | 6600 | 93.1 |
May 2007 | Good | Very Good | Very Good | Very Good | 6300 | 93.1 |
May 2005 | Good | Very Good | Very Good | Very Good | 6200 | 93.1 |
May 2004 | Good | Very Good | Very Good | Very Good | 6200 | 93.1 |
June 2003 | Good | Very Good | Very Good | Very Good | 6300 | 93.1 |
March 2001 | Good | Very Good | Excellent | Excellent | 6800 | 93.0 |