Share:

COVERED BRIDGE RD over RED OAK CREEK

Map

Coordinates:
+33.03858, -84.55187
33°02'19" N, 84°33'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COVERED BRIDGE RD over RED OAK CREEK
Structure number:000000019950460
Location:3 MI NE OF WOODBURY
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:100.1 ft. [30.5 m]
Total length:393.1 ft. [119.8 m]
Roadway width between curbs:8.9 ft. [2.7 m]
Deck width edge-to-edge:16.7 ft. [5.1 m]
Vertical clearance above deck:9.2 ft. [2.8 m]
Owner:County Highway Agency [02]
Year built:1930
Year reconstructed:1980
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Main span material:Wood or timber [7]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:104 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:15.1
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,675,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018PoorFairPoorPoor10415.1
May 2016PoorFairPoorPoor10415.1
May 2014PoorFairPoorPoor10415.1
May 2012PoorFairPoorPoor10415.1
May 2010PoorFairPoorPoor14014.5
May 2008PoorFairPoorPoor14014.5
March 2006PoorFairPoorPoor15014.3
May 2004PoorFairFairPoor10015.2
May 2002FairFairFairFair10015.2
May 2000FairFairFairFair10015.2
October 1999FairFairFairFair9015.4
June 1998PoorPoorSeriousImminent Failure900.0
December 1995FairFairFairFair9015.3
January 1994FairFairFairFair9015.3
May 1992FairFairFairFair9015.3
November 1990FairFairFairFair9017.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Timber Girder/Beamlinear ft.2,754112,713264
Timber Trusslinear ft.100010000
Substructure
Reinforced Concrete Columneach5757000
Reinforced Concrete Pier Walllinear ft.3803800
Timber Abutmentlinear ft.3434000
Timber Pileeach41030
Timber Pier Caplinear ft.3042822020
Deck
Timber Decksq. ft.4,864004,744120
Bridge Rail
Timber Bridge Raillinear ft.5860904960