Share:

PARK RD over IOWA RIVER

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+41.67151, -91.53451
41°40'17" N, 91°32'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PARK RD over IOWA RIVER
Structure number:000000000006350
Location:000000000
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:65.0 ft. [19.8 m]
Total length:353.0 ft. [107.6 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:64.0 ft. [19.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1959
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 13.5 / HS 15 [3]
Number of main spans:6
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:9,100 [as of 2014]
Deck condition:Serious [3 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:66.4
Recommended work:Bridge deck replacement with only incidental widening. [37]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017PoorSeriousFairSatisfactory910066.4
July 2015PoorSeriousFairSatisfactory910066.4
June 2013FairFairSatisfactorySatisfactory1010080.7
June 2011FairFairGoodSatisfactory1010090.7
June 2009FairFairGoodSatisfactory1170079.0
June 2007FairFairGoodSatisfactory1170079.3
June 2005FairFairGoodSatisfactory1170079.0
May 2003FairGoodGoodSatisfactory1170080.0
August 2001FairGoodGoodSatisfactory402081.3
June 1999FairGoodGoodSatisfactory402081.3
July 1997FairGoodGoodSatisfactory950080.4
December 1994FairGoodGoodSatisfactory840080.4
October 1992FairGoodGoodSatisfactory840081.4
July 1991PoorGoodGoodPoor840054.5