US 136 over MISSISSIPPI RIVER & RR,R
Map
Coordinates:
+40.39237, -91.3798440°23'33" N, 91°22'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 136 over MISSISSIPPI RIVER & RR,R |
Structure number: | 000000000033201 |
Location: | OVER MISS. RIVER-KEOKUK |
Purpose: | Carries highway over highway, waterway, and railroad |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 295.0 ft. [89.9 m] |
Total length: | 3346.3 ft. [1019.9 m] |
Roadway width between curbs: | 62.0 ft. [18.9 m] |
Deck width edge-to-edge: | 75.8 ft. [23.1 m] |
Vertical clearance below bridge: | 65.6 ft. [20.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1985 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 15 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Other [9] |
Latest Available Inspection: September 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 11,400 [as of 2018] |
Truck traffic: | 6% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 65.8 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2018 | Fair | Satisfactory | Good | Fair | 11400 | 65.8 |
September 2016 | Fair | Satisfactory | Good | Fair | 11000 | 69.7 |
September 2014 | Fair | Satisfactory | Good | Fair | 10700 | 69.7 |
September 2012 | Fair | Satisfactory | Very Good | Fair | 10900 | 69.7 |
September 2010 | Fair | Satisfactory | Very Good | Fair | 11600 | 69.7 |
October 2008 | Fair | Satisfactory | Very Good | Fair | 11500 | 69.7 |
October 2006 | Fair | Satisfactory | Very Good | Good | 13100 | 80.7 |
July 2004 | Fair | Satisfactory | Very Good | Good | 13100 | 80.7 |
September 2002 | Fair | Satisfactory | Very Good | Good | 13000 | 80.7 |
September 2000 | Good | Very Good | Very Good | Good | 13500 | 80.7 |
January 1990 | Fair | Satisfactory | Very Good | Very Good | 14000 | 80.7 |