Share:

MILLVILLE RD over PECK CREEK

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+42.69539, -91.16678
42°41'43" N, 91°10'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MILLVILLE RD over PECK CREEK
Structure number:000000000118270
Location:091031403
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:60.0 ft. [18.3 m]
Total length:60.0 ft. [18.3 m]
Roadway width between curbs:14.8 ft. [4.5 m]
Deck width edge-to-edge:15.7 ft. [4.8 m]
Owner:County Highway Agency [02]
Year built:1916
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:25 [as of 2013]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:56.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2016FairFairSatisfactorySatisfactory2556.8
November 2014FairFairSatisfactorySatisfactory2556.8
December 2012FairFairSatisfactorySatisfactory5056.8
November 2010FairFairSatisfactorySatisfactory5056.5
December 2009FairFairSatisfactorySatisfactory5056.5
December 2008FairFair-Satisfactory5056.5
December 2007FairFairSatisfactorySatisfactory5056.8
January 2007FairFairSatisfactorySatisfactory5056.8
February 2004FairFairSatisfactorySatisfactory5056.8
May 2002FairFairSatisfactorySatisfactory5056.8
January 2000FairFairSatisfactorySatisfactory5056.8
February 1998FairFairSatisfactorySatisfactory5056.8
January 1996FairFairSatisfactorySatisfactory1556.8
July 1994FairFairSatisfactorySatisfactory1556.8
July 1992FairFairSatisfactorySatisfactory1556.8
April 1990FairFairSatisfactorySatisfactory1556.8