I-380 over E AND F AVE NW, CEDAR RV
Map
Coordinates:
+41.97839, -91.6738141°58'42" N, 91°40'26" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-380 over E AND F AVE NW, CEDAR RV |
Structure number: | 000000000603700 |
Location: | 0.3 mi N. US 151 (1 ave) |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 67.9 ft. [20.7 m] |
Total length: | 685.1 ft. [208.8 m] |
Roadway width between curbs: | 111.6 ft. [34.0 m] |
Deck width edge-to-edge: | 119.8 ft. [36.5 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1979 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 10 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Low slump Concrete [4] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 71,800 [as of 2017] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 84.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 71800 | 84.3 |
August 2015 | Fair | Satisfactory | Fair | Fair | 70000 | 73.3 |
August 2013 | Fair | Satisfactory | Fair | Fair | 69700 | 71.3 |
August 2011 | Fair | Satisfactory | Fair | Fair | 69500 | 70.3 |
August 2009 | Fair | Satisfactory | Satisfactory | Fair | 58400 | 79.0 |
August 2007 | Fair | Satisfactory | Satisfactory | Fair | 57800 | 79.0 |
September 2005 | Fair | Good | Good | Satisfactory | 58700 | 89.0 |
February 2005 | Fair | Good | Good | Satisfactory | 54400 | 85.9 |
August 2003 | Fair | Good | Good | Satisfactory | 54800 | 87.9 |
December 2002 | Fair | Good | Good | Satisfactory | 51900 | 87.9 |
December 2000 | Fair | Good | Very Good | Satisfactory | 51300 | 86.9 |
October 1998 | Fair | Good | Very Good | Satisfactory | 5200 | 0.0 |
November 1996 | Fair | Good | Very Good | Satisfactory | 43200 | 81.9 |
October 1994 | Fair | Good | Very Good | Satisfactory | 45800 | 81.9 |
December 1992 | Fair | Good | Very Good | Satisfactory | 42000 | 85.0 |
April 1990 | Fair | Satisfactory | Good | Satisfactory | 38900 | 79.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 10,976 | 10,866 | 110 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 82,344 | 82,046 | 276 | 22 | 0 |
Wearing Surfaces | sq. ft. | 78,142 | 76,512 | 1,453 | 177 | 0 |
Substructure |
Reinforced Concrete Column | each | 24 | 20 | 4 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 1,341 | 946 | 389 | 6 | 0 |
Concrete Protective Coating | sq. ft. | 1,146 | 1,146 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 605 | 202 | 402 | 1 | 0 |
Bearings |
Movable Bearing | each | 52 | 33 | 0 | 19 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 2,194 | 2,190 | 4 | 0 | 0 |