Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 3 over FOURTH OF JULY CREEK |
Structure number: | 000000000010145 |
Location: | 3.1 N. ROSE LK.;JCT I 90 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 30.8 ft. [9.4 m] |
Total length: | 92.9 ft. [28.3 m] |
Roadway width between curbs: | 30.2 ft. [9.2 m] |
Deck width edge-to-edge: | 32.8 ft. [10.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1962 |
Year reconstructed: | 2015 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: July 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,100 [as of 2015] |
Truck traffic: | 9% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 81.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2017 | Fair | Good | Satisfactory | Satisfactory | 2100 | 81.3 |
July 2015 | Fair | Good | Satisfactory | Satisfactory | 2100 | 81.3 |
July 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 2100 | 78.3 |
July 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 2300 | 77.5 |
July 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 2700 | 76.2 |
July 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 2700 | 76.2 |
July 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 2700 | 76.2 |
July 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 2500 | 77.0 |
July 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 2500 | 77.0 |
July 2000 | Fair | Satisfactory | Good | Good | 2400 | 75.3 |
July 1998 | Fair | Satisfactory | Good | Good | 2400 | 75.3 |
July 1996 | Fair | Satisfactory | Good | Good | 2400 | 77.3 |
July 1994 | Fair | Satisfactory | Good | Good | 2400 | 78.9 |
July 1992 | Good | Good | Good | Good | 2030 | 80.2 |
July 1990 | Good | Good | Good | Good | 2030 | 78.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 651 | 581 | 70 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 3,041 | 3,041 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,808 | 2,808 | 0 | 0 | 0 |
Substructure |
Steel Column | each | 14 | 14 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 910 | 910 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 64 | 54 | 10 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 60 | 41 | 19 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 68 | 0 | 68 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 7 | 7 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 184 | 184 | 0 | 0 | 0 |