I 15 SBL over I 15B;POCATELLO CREEK IC
Map
Coordinates:
+42.89719, -112.4357842°53'50" N, 112°26'09" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I 15 SBL over I 15B;POCATELLO CREEK IC |
Structure number: | 000000000011276 |
Location: | IN POCATELLO |
Purpose: | Carries highway overpass over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 73.2 ft. [22.3 m] |
Total length: | 148.0 ft. [45.1 m] |
Roadway width between curbs: | 58.1 ft. [17.7 m] |
Deck width edge-to-edge: | 61.0 ft. [18.6 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1998 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 22.5 / HS 25 [9] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 18,250 [as of 2016] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 94.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Good | Good | 18250 | 94.0 |
November 2014 | Fair | Satisfactory | Good | Good | 15750 | 96.0 |
November 2012 | Fair | Satisfactory | Good | Good | 15750 | 98.0 |
November 2010 | Fair | Satisfactory | Very Good | Satisfactory | 32000 | 98.0 |
November 2008 | Fair | Satisfactory | Very Good | Satisfactory | 30500 | 98.0 |
November 2006 | Good | Good | Very Good | Very Good | 31500 | 98.0 |
November 2004 | Good | Good | Very Good | Very Good | 31500 | 98.0 |
November 2002 | Good | Good | Very Good | Very Good | 30000 | 98.0 |
November 2000 | Good | Good | Very Good | Very Good | 16200 | 98.0 |
June 1999 | Good | Good | Excellent | Excellent | 16200 | 98.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,024 | 1,024 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 11,575 | 11,575 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 9,028 | 8,308 | 696 | 24 | 0 |
Wearing Surfaces | sq. ft. | 8,613 | 8,613 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 8,613 | 8,613 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 25 | 25 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 125 | 125 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 62 | 57 | 5 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 121 | 0 | 121 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 7 | 7 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 364 | 349 | 14 | 1 | 0 |
Concrete Protective Coating | sq. ft. | 1,092 | 1,092 | 0 | 0 | 0 |