Share:

CR 450S over BR MILL CREEK

Map

Coordinates:
+39.59399, -86.65500
39°35'38" N, 86°39'18" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 450S over BR MILL CREEK
Structure number:6700182
Location:00.80 E of CR 1000 E
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:80.1 ft. [24.4 m]
Total length:81.0 ft. [24.7 m]
Roadway width between curbs:15.4 ft. [4.7 m]
Deck width edge-to-edge:15.4 ft. [4.7 m]
Vertical clearance below bridge:9.8 ft. [3.0 m]
Owner:County Highway Agency [02]
Year built:1905
Year reconstructed:1985
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Open Grating [3]
Wearing surface:Other [9]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:113 [as of 2017]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:29.5
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$904,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2018PoorFairPoorPoor11329.5
March 2016PoorFairPoorPoor11027.5
March 2015PoorFairPoorPoor11027.5
April 2013PoorFairPoorPoor10327.5
March 2011PoorFairPoorPoor10327.2
February 2009PoorFairSeriousPoor10027.9
March 2007PoorFairSeriousPoor10027.9
March 2005FairGoodSatisfactoryFair4146.1
March 2003FairGoodSatisfactoryFair4043.8
June 2000FairGoodSatisfactoryFair3743.7
December 1998FairGoodSatisfactoryFair3744.8
June 1996FairGoodSatisfactoryFair3530.0
April 1994FairGoodSatisfactoryFair10030.8
November 1991FairVery GoodSatisfactorySatisfactory10055.4
January 1990FairVery GoodSatisfactorySatisfactory10050.4