SOUTH BROADWAY(SB) over ARKANSAS RIVER
Map
Coordinates:
+37.64453, -97.3355237°38'40" N, 97°20'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SOUTH BROADWAY(SB) over ARKANSAS RIVER |
Structure number: | 53040087000AR30 |
Location: | SOUTH BROADWAY @ CARP ST. |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 100.7 ft. [30.7 m] |
Total length: | 801.5 ft. [244.3 m] |
Roadway width between curbs: | 26.9 ft. [8.2 m] |
Deck width edge-to-edge: | 49.9 ft. [15.2 m] |
Vertical clearance above deck: | 21.0 ft. [6.4 m] |
Skew angle: | 30° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1931 |
Year reconstructed: | 2016 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 8 |
Main spans material: | Concrete [1] |
Main spans design: | Arch - Thru [12] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,300 [as of 2006] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 71.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Good | Satisfactory | Satisfactory | 6300 | 71.5 |
December 2016 | Fair | Good | Satisfactory | Satisfactory | 6300 | 71.5 |
December 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 6300 | 23.3 |
July 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 6300 | 23.3 |
October 2013 | Fair | Good | Satisfactory | Satisfactory | 6300 | 65.9 |
September 2011 | Fair | Good | Satisfactory | Satisfactory | 6300 | 65.9 |
December 2009 | Fair | Good | Satisfactory | Satisfactory | 6300 | 65.9 |
August 2007 | Good | Good | Good | Good | 6300 | 65.9 |
November 2002 | Good | Good | Good | Good | 18673 | 55.2 |
February 2000 | Good | Very Good | Good | Very Good | 18673 | 55.2 |
May 1997 | Good | Very Good | Good | Very Good | 8985 | 57.3 |
February 1995 | Poor | Poor | Poor | Fair | 17687 | 6.0 |
October 1991 | Poor | Fair | Poor | Fair | 17687 | 8.0 |
June 1989 | Poor | Fair | Poor | Fair | 17687 | 12.4 |