Share:

US-23S over OHIO RIVER,CSX,STREETS

Map

Coordinates:
+38.48361, -82.64056
38°29'01" N, 82°38'26" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-23S over OHIO RIVER,CSX,STREETS
Structure number:010B00058N
Location:N-BOUND 23 SPUR OVR OHIO
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:740.2 ft. [225.6 m]
Total length:2315.1 ft. [705.6 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:47.2 ft. [14.4 m]
Vertical clearance above deck:18.0 ft. [5.5 m]
Vertical clearance below bridge:75.5 ft. [23.0 m]
Owner:State Highway Agency [01]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Truss - Thru [10]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:10,746 [as of 2016]
Truck traffic:14% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:60.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017FairSatisfactorySatisfactorySatisfactory1074660.0
September 2015FairSatisfactorySatisfactorySatisfactory1061460.0
September 2013FairSatisfactorySatisfactoryGood1469660.0
October 2011FairSatisfactoryGoodGood1250073.5
October 2009FairSatisfactoryGoodGood1710072.9
November 2007FairGoodSatisfactoryGood1690072.9
October 2003FairGoodSatisfactoryGood1592077.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Closed Web/Box Girderlinear ft.9448910
Steel Protective Coatingsq. ft.1,2691,14200127
Steel Girder/Beamlinear ft.3,7242,993713180
Steel Protective Coatingsq. ft.33,516032,7780738
Steel Stringerlinear ft.10,1768,2811,876190
Steel Protective Coatingsq. ft.62,75359,5833,138032
Deck
Reinforced Concrete Decksq. ft.109,36988,92120,44440
Superstructure
Steel Trusslinear ft.3,3922,425950170
Steel Protective Coatingsq. ft.294,891244,75929,48914,7455,898
Steel Floor Beamlinear ft.2,1261,0531,043300
Steel Protective Coatingsq. ft.25,53522,9811,27701,277
Steel Gusset Plateeach20410780170
Steel Protective Coatingsq. ft.7,3446,1881,1023717
Substructure
Reinforced Concrete Columneach1914410
Reinforced Concrete Pier Walllinear ft.130130000
Reinforced Concrete Abutmentlinear ft.112971500
Reinforced Concrete Pile Cap/Footinglinear ft.144144000
Reinforced Concrete Pier Caplinear ft.4403379580
Joints
Pourable Jointlinear ft.484366491554
Compression Jointlinear ft.1110101982
Open Jointlinear ft.95236750
Bearings
Movable Bearingeach421121100
Steel Protective Coatingsq. ft.1,5101,289660155
Fixed Bearingeach156720
Steel Protective Coatingsq. ft.642635007
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4,6302,1812,44810